The construction products and/or materials which satisfy all the requirements of the performance characteristic ‘reaction to fire’ without need for further testing are set out in the Annex.
資料由法律人 LawPlayer整理提供·EU law / curated by LawPlayer from EUR-Lex
2005/610/EC: Commission Decision of 9 August 2005 establishing the classes of reaction-to-fire performance for certain construction products (notified under document number C(2005) 2925) (Text with EEA relevance)
The specific classes to be applied to different construction products and/or materials, within the reaction-to-fire classification adopted in Decision 2000/147/EC, are set out in the Annex to this Decision.
This Decision is addressed to the Member States.
Schedules & Appendices
ANNEX
The tables set out in this Annex, list construction products and/or materials which satisfy all of the requirements for the performance characteristic reaction to fire without need for testing.
Table 1
CLASSES OF REACTION TO FIRE PERFORMANCE FOR GLULAM ( 1 )
Material
Product detail
Minimum mean density ( 2 )
(kg/m 3 )
Minimum overall thickness
(mm)
Class ( 3 )
Glulam
Glued laminated timber products in accordance with EN 14080.
380
40
D-s2, d0
Table 2
CLASSES OF REACTION TO FIRE PERFORMANCE OF LAMINATE FLOOR COVERINGS
Floor covering type ( 4 )
Product detail
Minimum density
(kg/m 3 )
Minimum overall thickness
(mm)
Class ( 5 )
Floorings
Laminate floor coverings
Laminate floor coverings manufactured in accordance with EN 13329:2000.
800
6,5
E FL
Table 3
CLASSES OF REACTION TO FIRE PERFORMANCE OF RESILIENT FLOOR COVERINGS
Floor covering type ( 6 )
EN product standard
Minimum mass
(g/m 2 )
Maximum mass
(g/m 2 )
Minimum overall thickness
(mm)
Class ( 7 )
Floorings
Plain and decorative Linoleum
EN 548
2 300
4 900
2
E FL
Homogeneous and heterogeneous polyvinyl chloride floor coverings
EN 649
2 300
3 900
1,5
E FL
Polyvinyl chloride floor coverings with foam layer
EN 651
1 700
5 400
2
E FL
Polyvinyl chloride floor covering with cork-based backing
EN 652
3 400
3 700
3,2
E FL
Expanded (cushioned) polyvinyl chloride floor coverings
EN 653
1 000
2 800
1,1
E FL
Semi-flexible polyvinyl chloride tiles
EN 654
4 200
5 000
2
E FL
Linoleum on corkment backing
EN 687
2 900
5 300
2,5
E FL
Homogeneous and heterogeneous smooth rubber floor coverings with foam backing
EN 1816
3 400
4 300
4
E FL
Homogeneous and heterogeneous smooth rubber floor coverings
EN 1817
3 000
6 000
1,8
E FL
Homogeneous and heterogeneous relief rubber floor coverings
EN 12199
4 600
6 700
2,5
E FL
Table 4
CLASSES OF REACTION TO FIRE PERFORMANCE OF TEXTILE FLOOR COVERINGS
Floor covering type ( 8 )
EN product standard
Class ( 9 )
Floorings
Non-FR machine-made wall-to-wall pile carpets and pile carpet tiles ( 10 )
EN 1307
E FL
Non-FR needled textile floor coverings without pile ( 10 )
EN 1470
E FL
Non-FR needled textile floor coverings with pile ( 10 )
EN 13297
E FL
( 1 ) Applies to all species and glues covered by the product standard.
( 2 ) Conditioned according to EN 13238.
( 3 ) Class as provided for in Table 1 of the Annex to Decision 2000/147/EC.
( 4 ) Floor covering loose laid over any wood based substrate ≥ D-s2, d0, or any substrate of class A2-s1, d0.
( 5 ) Class as provided for in table 2 to the Annex to Decision 2000/147/EC.
( 6 ) Floor covering loose laid over any wood based substrate ≥ D-s2, d0, or any substrate of class A2-s1, d0.
( 7 ) Class as provided for in table 2 to the Annex to Decision 2000/147/EC.
( 8 ) Floor covering glued or loose laid over a class A2-s1, d0 substrate
( 9 ) Class as provided for in table 2 to the Annex to Decision 2000/147/EC.
( 10 ) Textile floor coverings having a total mass of max 4 800 g/m 2 , a minimum pile thickness of 1,8 mm (ISO 1766) and:
—
a surface of 100 % wool,
—
a surface of 80 % wool or more — 20 % polyamide or less,
—
a surface of 80 % wool or more — 20 % polyamide/polyester or less,
—
a surface of 100 % polyamide,
—
a surface of 100 % polypropylene and if with SBR-foam backing, a total mass of > 780 g/m 2 . All polypropylene carpets with other foam backings are excluded.
Cite this act
2005/610/EC: Commission Decision of 9 August 2005 establishing the classes of reaction-to-fire performance for certain construction products (notified under document number C(2005) 2925) (Text with EEA relevance) (EUR-Lex). Retrieved via LawPlayer, https://lawplayer.com/eu/act/32005D0610
© European Union, https://eur-lex.europa.eu, 1998-2026. Reuse authorised under Commission Decision 2011/833/EU, provided the source is acknowledged.
本頁資料來源:EUR-Lex·整理提供:法律人 LawPlayer· lawplayer.com