Wood-based panels covered by the harmonised standard EN 13986 and solid wood panelling and cladding covered by the harmonised standard EN 14915 which fulfil the conditions set out in the Annex shall be deemed to satisfy the classes of performance indicated in the Annex without testing, when they are used for wall and ceiling covering.
資料由法律人 LawPlayer整理提供·EU law / curated by LawPlayer from EUR-Lex
Commission Delegated Regulation (EU) No 1291/2014 of 16 July 2014 on the conditions for classification, without testing, of wood-based panels under EN 13986 and solid wood panelling and cladding under EN 14915 with regard to their fire protection ability, when used for wall and ceiling covering Text with EEA relevance
This Regulation shall enter into force on the twentieth day following that of its publication in the Official Journal of the European Union .
Schedules & Appendices
ANNEX
Product ( 1 )
EN product standard
Product detail ( 2 )
Minimum mean density
(kg/m 3 )
Minimum thickness
(mm)
K Class ( 3 )
Hardboard
EN 13986
With and without tongue and groove ( 5 )
800
9
K 2 10 ( 4 )
OSB
EN 13986
With and without tongue and groove ( 6 )
600
10
K 2 10 ( 4 )
Particleboard
EN 13986
With tongue and groove ( 7 )
600
10
K 2 10 ( 4 )
Particleboard
EN 13986
With and without tongue and groove ( 6 )
600
12
K 2 10 ( 4 )
Plywood
EN 13986
With and without tongue and groove ( 6 )
450
12
K 2 10 ( 4 )
Solid wood panels
EN 13986
With and without tongue and groove ( 6 )
450
12
K 2 10 ( 4 )
Particleboard
EN 13986
With tongue and groove ( 8 )
600
25
K 2 30
OSB
EN 13986
With tongue and groove ( 8 )
600
30
K 2 30
Plywood
EN 13986
With tongue and groove ( 8 )
450
26
K 2 30
Solid wood panels
EN 13986
With tongue and groove ( 8 )
450
26
K 2 30
Solid wood panels
EN 13986
With tongue and groove ( 9 )
450
53
K 2 60
Solid wood panelling and cladding
EN 14915
With tongue and groove ( 10 )
450
15
K 2 10 ( 4 )
Solid wood panelling and cladding
EN 14915
With tongue and groove ( 10 )
450
27
K 2 30
Solid wood panelling and cladding
EN 14915
With tongue and groove ( 11 )
450
2 × 27 ( 12 )
K 2 60
( 1 ) Mounted directly on any substrate without an air gap.
( 2 ) Joints with square edges or tongue and groove profile and with the same thickness as the product and without gaps.
( 3 ) Class as set out in Decision 2000/367/EC.
( 4 ) K 1 10 for substrates ≥ 300 kg/m 3
( 5 ) Brad length minimum 40 mm and spacing maximum 100 mm
( 6 ) Screw length minimum 30 mm and spacing maximum 200 mm
( 7 ) Screw length minimum 30 mm and spacing maximum 150 mm
( 8 ) Screw length minimum 50 mm and spacing maximum 200 mm
( 9 ) Screw length minimum 75 mm and spacing maximum 200 mm
( 10 ) Nail length minimum 60 mm and spacing maximum 600 mm
( 11 ) Nail length minimum 50 mm (in each layer) and spacing maximum 600 mm
( 12 ) The two layers are mounted with the longitudinal direction of the layers perpendicular to each other.
Cite this act
Commission Delegated Regulation (EU) No 1291/2014 of 16 July 2014 on the conditions for classification, without testing, of wood-based panels under EN 13986 and solid wood panelling and cladding under EN 14915 with regard to their fire protection ability, when used for wall and ceiling covering Text with EEA relevance (EUR-Lex). Retrieved via LawPlayer, https://lawplayer.com/eu/act/32014R1291
© European Union, https://eur-lex.europa.eu, 1998-2026. Reuse authorised under Commission Decision 2011/833/EU, provided the source is acknowledged.
本頁資料來源:EUR-Lex·整理提供:法律人 LawPlayer· lawplayer.com