Wood floorings covered by the harmonised standard EN 14342 which fulfil the conditions set out in the Annex shall be deemed to satisfy the classes of performance indicated in the Annex without testing.
資料由法律人 LawPlayer整理提供·EU law / curated by LawPlayer from EUR-Lex
Commission Delegated Regulation (EU) No 1292/2014 of 17 July 2014 on the conditions for classification, without testing, of certain uncoated wood floorings under EN 14342 with regard to their reaction to fire Text with EEA relevance
This Regulation shall enter into force on the twentieth day following that of its publication in the Official Journal of the European Union .
Schedules & Appendices
ANNEX
Product ( 1 )
( 7 )
Product detail ( 4 )
Minimum mean density ( 5 )
(kg/m 3 )
Minimum overall thickness
(mm)
End use condition
Class for floorings ( 3 )
Wood flooring
Solid wood flooring of pine or spruce
Pine: 480
Spruce: 400
14
Without air gap underneath
D fl -s1
Wood flooring
Solid flooring of beech, oak, pine or spruce
Beech: 700
Oak: 700
Pine: 430
Spruce: 400
20
With or without air gap underneath
D fl -s1
Wood parquet
Solid wood (one layer) parquet of walnut
650
8
Glued to substrate ( 6 )
D fl -s1
Wood parquet
Solid (one layer) parquet of oak, maple or ash
Ash: 650
Maple: 650
Oak: 720
8
Glued to substrate ( 6 )
D fl -s1
Wood parquet
Multilayer parquet with oak top layer, at least 3,5 mm
550
15 ( 2 )
Without air gap underneath
D fl -s1
Wood flooring and parquet
Solid wood flooring and parquet not specified above
400
6
All
E fl
( 1 ) Mounted in accordance with EN ISO 9239-1, on a substrate of at least Class D-s2, d0 with minimum density of 400 kg/m 3 or with an air gap (minimum height 30 mm) underneath.
( 2 ) An interlayer of at least Class E fl and with maximum thickness 3 mm and minimum density of 280 kg/m 3 may be included.
( 3 ) Class as set out in Table 2 of the Annex to Decision 2000/147/EC.
( 4 ) Without surface coatings.
( 5 ) Conditioned in accordance with EN 13238 (50 % RH, 23 °C).
( 6 ) Substrate at least Class D-s2, d0.
( 7 ) Applies also to steps of stairs.
Cite this act
Commission Delegated Regulation (EU) No 1292/2014 of 17 July 2014 on the conditions for classification, without testing, of certain uncoated wood floorings under EN 14342 with regard to their reaction to fire Text with EEA relevance (EUR-Lex). Retrieved via LawPlayer, https://lawplayer.com/eu/act/32014R1292