Cross laminated timber products covered by the harmonised standard EN 16351 and laminated veneer lumber products covered by the harmonised standard EN 14374 which fulfil the conditions set out in the Annex shall be deemed to satisfy the classes of performance indicated in the Annex without testing.
資料由法律人 LawPlayer整理提供·EU law / curated by LawPlayer from EUR-Lex
Commission Delegated Regulation (EU) 2017/2293 of 3 August 2017 on the conditions for classification, without testing, of cross laminated timber products covered by the harmonised standard EN 16351 and laminated veneer lumber products covered by the harmonised standard EN 14374 with regard to their reaction to fire (Text with EEA relevance. )
This Regulation shall enter into force on the twentieth day following that of its publication in the Official Journal of the European Union .
Schedules & Appendices
ANNEX
Table 1
Classes of reaction to fire performance for cross laminated timber products and laminated veneer lumber products for walls and ceilings
Product ( 1 )
Product detail
Minimum mean density ( 2 ) (kg/m 3 )
Minimum overall thickness (mm)
Class ( 3 )
Cross laminated timber products covered by the harmonised standard EN 16351
Minimum layer thickness of 18 mm
350
54
D-s2, d0 ( 4 )
Laminated veneer lumber products covered by the harmonised standard EN 14374
Minimum veneer thickness of 3 mm
400
18
D-s2, d0 ( 4 )
Table 2
Classes of reaction to fire performance for cross laminated timber products and laminated veneer lumber products for floorings
Product ( 5 )
Product detail
Minimum mean density ( 6 ) (kg/m 3 )
Minimum overall thickness (mm)
Class for floorings ( 7 )
Cross laminated timber products covered by the harmonised standard EN 16351
minimum layer thickness of 18 mm and with the surface layer made of pine
430
54
D FL -s1 ( 8 )
Cross laminated timber products covered by the harmonised standard EN 16351
minimum layer thickness of 18 mm and with the surface layer made of spruce
400
54
D FL -s1 ( 8 )
Laminated veneer lumber products covered by the harmonised standard EN 14374
with a minimum veneer thickness of 3 mm and with the surface layer made of pine
480
15
D FL -s1 ( 8 )
Laminated veneer lumber products covered by the harmonised standard EN 14374
with a minimum veneer thickness of 3 mm and with the surface layer made of pine
430
20
D FL -s1 ( 8 )
Laminated veneer lumber products covered by the harmonised standard EN 14374
with a minimum veneer thickness of 3 mm and with the surface layer made of spruce
400
15
D FL -s1 ( 8 )
( 1 ) Applies to all species and glues covered by the product standards.
( 2 ) Conditioned in accordance with standard EN 13238.
( 3 ) Class as set out in Table 1 of the Annex to Delegated Regulation (EU) 2016/364.
( 4 ) Class valid for any substrate or air gap behind.
( 5 ) Applies also to steps of stairs.
( 6 ) Conditioned in accordance with standard EN 13238.
( 7 ) Class as set out in Table 2 of the Annex to Delegated Regulation (EU) 2016/364.
( 8 ) Class valid for any substrate or air gap behind.
Cite this act
Commission Delegated Regulation (EU) 2017/2293 of 3 August 2017 on the conditions for classification, without testing, of cross laminated timber products covered by the harmonised standard EN 16351 and laminated veneer lumber products covered by the harmonised standard EN 14374 with regard to their reaction to fire (Text with EEA relevance. ) (EUR-Lex). Retrieved via LawPlayer, https://lawplayer.com/eu/act/32017R2293