ANNEX
Summary of product characteristics for a biocidal product
Bioquell HPV-AQ
Product type 2 - Disinfectants and algaecides not intended for direct application to humans or animals (Disinfectants)
Product type 3 - Veterinary hygiene (Disinfectants)
Product type 4 - Food and feed area (Disinfectants)
Product type 2 - Disinfectants and algaecides not intended for direct application to humans or animals (Disinfectants)
Product type 3 - Veterinary hygiene (Disinfectants)
Product type 4 - Food and feed area (Disinfectants)
Authorisation number: EU-0027469-0000
R4BP asset number: EU-0027469-0000
1. ADMINISTRATIVE INFORMATION
1.1. Trade name(s) of the product
Trade name(s)
Bioquell HPV-AQ
1.2. Authorisation holder
Name and address of the authorisation holder
Name
Ecolab Deutschland GmbH
Address
Ecolab Allee 1, 40789 Monheim am Rhein Germany
Authorisation number
EU-0027469-0000
R4BP asset number
EU-0027469-0000
Date of the authorisation
7.8.2022
Expiry date of the authorisation
31.7.2032
1.3. Manufacturer(s) of the product
Name of manufacturer
Ecolab SNC
Address of manufacturer
153 Quai de Rancy, Bonneuil-sur-Marne, 94380 Paris France
Location of manufacturing sites
153 Quai de Rancy, Bonneuil-sur-Marne, 94380 Paris France
53 Royce Close, SP10 3TS Andover United Kingdom Unit E4, Eastway Business Park, Ballysimon Road, V94 K267 Limerick Ireland
1.4. Manufacturer(s) of the active substance(s)
Active substance
Hydrogen peroxide
Name of manufacturer
Evonik Peroxide Spain
Address of manufacturer
Beethoven 15, Sobreatico, 08021 Barcelona Spain
Location of manufacturing sites
C/ Afueras s/n La Zaida, 50784 Zaragoza Spain
2. PRODUCT COMPOSITION AND FORMULATION
2.1. Qualitative and quantitative information on the composition of the product
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
Hydrogen peroxide
Active Substance
7722-84-1
231-765-0
35,0
2.2. Type of formulation
HN - Hot fogging concentrate
3. HAZARD AND PRECAUTIONARY STATEMENTS
Hazard statements
May intensify fire; oxidiser
Harmful if swallowed.
Causes skin irritation.
Causes serious eye damage.
May cause respiratory irritation.
Harmful to aquatic life with long lasting effects.
Precautionary statements
Keep away from clothing and other combustible materials.
Avoid breathing vapours.
Do not eat, drink or smoke when using this product.
Avoid release to the environment.
Wear protective gloves/protective clothing/eye protection.
IF SWALLOWED: Call a Poison Centre or doctor/physician if you feel unwell.
Rinse mouth.
IF ON SKIN: Wash with plenty of water.
If skin irritation occurs: Get medical attention.
Take off contaminated clothing. And wash it before reuse.
IF INHALED: Remove person to fresh air and keep comfortable for breathing.
IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Immediately call a POISON CENTER or doctor/physician.
Call a POISON CENTER/doctor if you feel unwell.
In case of fire: Use water to extinguish.
Store in a well-ventilated place. Keep container tightly closed.
Store locked up.
Dispose of contents to waste in accordance with applicable local, national and international regulations.
4. AUTHORISED USE(S)
4.1. Use description
Table 1.
Use # 1 – Surface disinfection in small (0,25 m 3 -4 m 3 ) enclosures
Product type
PT02 - Disinfectants and algaecides not intended for direct application to humans or animals (Disinfectants)
PT03 - Veterinary hygiene (Disinfectants)
PT04 - Food and feed area (Disinfectants)
Where relevant, an exact description of the authorised use
-
Target organism(s) (including development stage)
Common name: Bacteria
Development stage:
Common name: bacteria spores
Development stage:
Common name: Mycobacteria
Development stage:
Common name: Fungi
Development stage:
Common name: Yeasts
Development stage:
Common name: Viruses
Development stage:
Common name: bacteriophage
Development stage:
Field(s) of use
Indoor
Hard, non-porous surfaces in small (0,25 m 3 to 4 m 3 ) sealed enclosures by vaporisation, with prior cleaning.
PT2 – clean conditions in, for example, isolators, pass-through chambers, cabinets, material airlocks, cupboards, filling lines, emergency vehicles.
PT3 – pre-cleaned animal cages/racks within biomedical and animal laboratory facilities
PT4 – clean conditions in, for example, aseptic filling lines, storage containers.
Application method(s)
Method: vaporisation
Detailed description:
Vaporisation with Bioquell Hydrogen Peroxide Vapour system followed by micro condensation – to deliver the disinfectant to surfaces in closed systems.
Temperature range: room temperature
Humidity range: 10 %-80 %
Application rate(s) and frequency
Application Rate: 100 g/m 3 of undiluted product, contact time of 35 minutes (after diffusion).
Dilution (%): 0
Number and timing of application:
Users should carry out decontaminations in line with their requirements and operating procedures
Category(ies) of users
Professional
Pack sizes and packaging material
75 ml, 150 ml, 500 ml, 950 ml, 1 000 ml, 2 000 ml, 5 000 ml and 25 L. Bottles are constructed of HDPE
4.1.1. Use-specific instructions for use
See general directions for use.
4.1.2. Use-specific risk mitigation measures
See general directions for use.
4.1.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See general directions for use.
4.1.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
Only recycle completely emptied packaging. Dispose of any residual product in accordance with EWC 160903
4.1.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
Protect from frost. Do not store at temperatures above 35 °C
Shelf life 18 months.
4.2. Use description
Table 2.
Use # 2 – Surface disinfection within large (> 4 m 3 ) enclosures
Product type
PT02 - Disinfectants and algaecides not intended for direct application to humans or animals (Disinfectants)
PT03 - Veterinary hygiene (Disinfectants)
PT04 - Food and feed area (Disinfectants)
Where relevant, an exact description of the authorised use
-
Target organism(s) (including development stage)
Common name: Bacteria
Development stage:
Common name: Mycobacteria
Development stage:
Common name: Bacteria spores
Development stage:
Common name: Fungi
Development stage:
Common name: Yeasts
Development stage:
Common name: Viruses
Development stage:
Common name: bacteriophages
Development stage:
Field(s) of use
Indoor
Hard, non-porous surfaces in large (> 4 m 3 ) sealed enclosures by vaporisation, with prior cleaning.
PT2 – clean conditions in, for example hospitals, clean rooms, aseptic processing facilities, laboratories, nursing homes, research facilities, schools, cruise ships, emergency vehicles, veterinary hospitals (excluding animal housing), laboratories in veterinary institutions
PT3 – pre-cleaned animal cages/racks within biomedical and animal laboratory facilities.
PT4 – clean conditions in, for example, aseptic filling lines, food production facilities, storage containers
Application method(s)
Method: vaporisation
Detailed description:
Vaporisation with Bioquell Hydrogen Peroxide Vapour system followed by micro condensation – to deliver the disinfectant to surfaces in closed systems.
Temperature range: Room temperature
Humidity range:10 %-80 %
Application rate(s) and frequency
Application Rate: 10 g/m 3 of undiluted product, contact time of 35 minutes (after diffusion
Dilution (%): 0
Number and timing of application:
Users should carry out decontaminations in line with their requirements and operating procedures.
Category(ies) of users
Professional
Pack sizes and packaging material
75 ml, 150 ml, 500 ml, 950 ml, 1 000 ml, 2 000 ml, 5 000 ml and 25 L. Bottles are constructed of HDPE.
4.2.1. Use-specific instructions for use
See general directions for use
4.2.2. Use-specific risk mitigation measures
See general directions for use
4.2.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See general directions for use
4.2.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
Only recycle completely emptied packaging. Dispose of any residual product in accordance with EWC 160903
4.2.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
Protect from frost. Do not store at temperatures above 35 °C. Shelf life 18 months.
5. GENERAL DIRECTIONS FOR USE ( 1 )
5.1. Instructions for use
Surfaces must be pre-cleaned and dry before disinfection and cupboard doors and drawers should be opened for the process to be effective.
Users should carry out decontaminations in line with their requirements and operating procedures.
For disinfection of pre-cleaned animal cages/racks within biomedical and animal laboratory facilities, disinfection can only take place on thoroughly cleaned non-porous surfaces (PT3), when possible use automated washing machines.
Do not mix with detergents or other chemicals. Undiluted.
Bioquell HPV-AQ is to be used with a Bioquell vaporisation module as a disinfectant for surfaces and other inanimate objects in enclosures.
Seal the enclosure (e.g. with tape) to ensure no leakage of the vaporised active substance outside the enclosure prior to initiating a cycle.
Refer to the Bioquell HPV-AQ Labelling insert prior to running a cycle.
At the end of the dwell period, the aeration phase is activated which removes the hydrogen peroxide. The aeration phase is deactivated by the user when the enclosure has been confirmed to be less than or equal to 1,25 mg/m 3 (0,9 ppm) using an independent calibrated low-level hydrogen peroxide sensor.
Biological validation should be performed for enclosures to be disinfected. Where environmental conditions within an enclosure are well controlled, a protocol for disinfection of the enclosure should be made and used thereafter. Validated quantitative chemical indicators can be used in place of biological indicators for routine disinfection.
Biological or chemical indicators shall be placed in the enclosure to validate the cycle.
Users should not carry out manual cleaning operations (for example sweeping) immediately post-decontamination.
5.2. Risk mitigation measures
No person or animals are allowed to be present in a room during treatment.
Treated areas may not be entered until the concentration of hydrogen peroxide is ≤ 0,9 ppm (1,25 mg/m 3 ).
The professional user may only enter the room in emergency situations when the hydrogen peroxide level has dropped below 36 ppm (50 mg/m 3 ) considering RPE with APF 40 (Type of RPE to be specified by the authorisation holder within the product information) and suitable protective equipment (gloves, eye protection, coverall) must be worn.
Use a calibrated sensor to confirm the enclosure is ≤ 0,9 ppm (1,25 mg/m 3 ) prior to re-entry.
When opening the container and preparing contents wear suitable personal protective equipment (gloves, eye protection, coverall).
Wash hands after use.
5.3. Particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
Possible exposure effects:
Skin – chemical burn – transient, non-permanent whitening of the skin
Eyes – potential for permanent damage
Inhalation - irritation of the throat and nose
IF INHALED : Move to fresh air and keep at rest in a position comfortable for breathing.
If symptoms: Call 112/ambulance for medical assistance.
If no symptoms: Call a POISON CENTRE or a doctor.
Information to Healthcare personnel/doctor:
Initiate life support measures if needed, thereafter call a POISON CENTRE.
IF SWALLOWED : Immediately rinse mouth. Give something to drink, if exposed person is able to swallow. Do NOT induce vomiting. Call 112/ambulance for medical assistance.
IF ON SKIN : Take off all contaminated clothing and wash it before reuse. Wash skin with water. If skin irritation occurs: Get medical advice.
IF IN EYES : Immediately rinse with water for several minutes. Remove contact lenses, if present and easy to do. continue rinsing for at least 15 minutes. Call 112/ambulance for medical assistance.
5.4. Instructions for safe disposal of the product and its packaging
Do not discharge unused product on the ground, into water courses, into pipes (sink, toilets...) nor down the drains. Dispose of unused product, its packaging and all other waste, in accordance with local regulations.
5.5. Conditions of storage and shelf-life of the product under normal conditions of storage
Protect from Frost. Do not store at temperatures above 35 °C.
Shelf life 18 months.
6. OTHER INFORMATION
Bioquell HPV-AQ is not intended for use as a terminal sterilant/disinfectant for medical devices.
( 1 ) Instructions for use, risk mitigation measures and other directions for use under this section are valid for any authorised uses.