ANNEX II
ECODESIGN RREQUIREMENTS FOR FANS
Fans shall comply with the ecodesign requirements set out in points 1 to 5 of this Annex, except for fans that meet all the following criteria:
(a)
are integrated or placed on the market exclusively to be integrated into other products;
(b)
are placed on the market within the first year after the date of application of this Regulation;
(c)
meet the requirements of Annex I to Regulation (EU) No 327/2011, using the calculation methods in Annex II to that Regulation, and verifiable by market surveillance authorities in accordance with Annex III to that Regulation, in line with the fan’s declaration of conformity;
(d)
the first unit of the concerned model is placed on the market before 24 July 2026.
However, until 24 July 2037, spare part fans replacing fans placed on the market before 24 July 2026, or until the date of the last placing on the market of the last unit of the model for fans that meet the criteria (a) to (d) above, and integrated into a product, are exempt from the requirements set out in points 1 to 5, provided that:
(a)
in the range of products offered by the manufacturer/importer/authorised representative, there is no replacement fan that is fit to be integrated into the product in question which is compliant with this Regulation;
(b)
they comply with the information requirements set out in point 6;
(c)
they meet the requirements set out in point 2 of Annex I to Regulation (EU) No 327/2011 that were applicable at the date of placing on the market of the fan it is intended to replace, using the calculation methods in Annex II to that Regulation, and verifiable by market surveillance authorities in accordance with Annex III to that Regulation.
1. Minimum fan efficiency requirements
With effect from 24 July 2026, the following rules shall apply:
1.
Fans, except jet fans, cross flow fans and fans referred to in point 7, shall have a fan efficiency ( η ) equal to or larger than the minimum fan efficiency ( η
min ), which is a function of the electric input power P
e (in kW) and minimum efficiency grade N following the equations:
—
for fans with P e
< 10 kW: η
min = 4,56 ln( P e
) – 10,5 + N [%];
—
for fans with P e
≥ 10 kW: η
min = 1,1 ln( P e
) – 2,6 + N [%].
2.
Jet fans shall have a fan efficiency ( η r
) equal to or larger than the minimum jet fan efficiency ( η
r,min ), which is a function of the electric input power P e
(in kW) and minimum efficiency grade N following the equations:
—
for jet fans with P e ≥ 750 W and < 10 kW: η r,min = 7,32 ln( P e
) – 21,25 + N [%];
—
for jet fans with P e ≥ 10 kW: η r,min = 1,73 ln( P e
) – 8,35 + N [%].
3.
Cross flow fans shall have a minimum total fan efficiency (B,D) of at least 0,21 (21 %) over the entire power range.
4.
The fan efficiency shall be established in accordance with the measurement and calculations methods set in Annex III.
Except for cross flow fans, the values of the minimum efficiency grade N are set out in Table 1 per fan type, efficiency category (static or total) and measurement category (A to E) as appropriate.
Table 1
Minimum efficiency grades
Fan type
Measurement category
Efficiency category (pressure)
Minimum efficiency grades ( N )
Axial fans
A, C
static
50
B, D
total
64
Forward curved < 5 kW and backward inclined centrifugal fans
A, C
static
52
B, D
total
57
Other centrifugal fans
A, C
static
64
B, D
total
67
Mixed flow fans
A, C
static
57 + 7 • (α –45 ) / 25
B, D
total
67
Jet fans ≥ 750 W
E
50
5.
The calculation of the minimum efficiency grade N for mixed flow fans involves the fan flow angle α, in degrees rounded to the nearest integer, established in accordance with point 4 of Annex III.
6.
For fans having the following characteristics, the values of the minimum efficiency grades N set out in Table 1 shall be multiplied by the corresponding factor(s), as applicable:
Fans characteristics
Factor value
Dual use fans designed for both ventilation under normal conditions and emergency use as set out in Article 1(3) point b
0,9
Reversible fans
0,85
Low noise fans
0,9
7.
For centrifugal fans with specific speed σ ΒΕΡ
< 0,12, electric input power P e
< 10 kW, measurement category B or D and efficiency category ‘total’, the minimum fan efficiency ( η min
) is a function of σ ΒΕΡ
as follows: η min
= 2,95 * σ ΒΕΡ
+ 0,2.
2. Product information requirements on fans
1.
With effect from 24 July 2026, the information on fans set out in points 2(a) to (o) shall be visibly displayed in:
(a)
the technical data sheet or user manual supplied with the fan, unless an internet link or a QR code linking to the free access website referred to in point (c) is supplied with the fan. A pictogram as in ISO 7000:2019 reference n°1641 is displayed next to the link or QR code;
(b)
the technical documentation for the purposes of conformity assessment pursuant to Article 4, in the order as listed in points 2(a) to (q), the exact wording does not need to be repeated, information may be displayed using graphs, figures or symbols rather than text;
(c)
free access websites of the manufacturer of the fan, its authorised representative or the importer for a period of at least 20 years after the placing on the market of the last unit of the model concerned.
2.
The following information shall be displayed:
(a)
fan type: select one of the following types: axial fan, forward curved centrifugal fan, backward curved centrifugal fan, backward inclined centrifugal fan, cross flow fan, mixed flow fan, jet fan;
(b)
fan efficiency ( η or η r
), either as a number rounded to the nearest third decimal, or as a percentage (with symbol ‘%’) rounded to the nearest decimal;
(c)
whether the calculation of fan efficiency assumed use of a VSD and if so, whether the VSD is integrated in the fan or the VSD must be installed with the fan;
(d)
measurement category used to determine the fan efficiency (A-E);
(e)
efficiency category (static or total), except for jet fans;
(f)
efficiency grade N at BEP or T m , except for cross flow fans;
(g)
the electric input power P
e (in kW, rounded to the nearest third decimal), volume flow rate q
v (in m 3 /h rounded to the nearest integer, or alternatively, when flow rate is ≥ 0,50 m 3 /s in m 3 /s rounded to the nearest second decimal), and applicable pressure difference Δ p (in Pa, rounded to the nearest integer) at BEP or T m ;
(h)
special characteristics: select one or more of the following: dual use fan, reversible fan, low noise fan;
(i)
DC voltage lower than 100 V, with answer ‘yes’ or ‘no’;
(j)
list of all significant elements supplied with the fan;
(k)
specific speed σ ΒΕΡ
, only for centrifugal fans with specific speed σ ΒΕΡ
< 0,12, electric input power P e
< 10 kW, measurement category B or D and efficiency category ‘total’;
(l)
fan speed in revolutions per minute (in rpm, rounded to the nearest integer) at BEP or T m ;
(m)
the specific ratio, rounded to the nearest second decimal;
(n)
manufacturer’s name, registered trade name or registered trademark, and the address at which the manufacturer can be contacted;
(o)
the model identifier and, where appropriate, other codes and marks sufficient for the product to be unequivocally and easily identified;
(p)
information relevant for facilitating disassembly, recycling or disposal at end-of-life;
(q)
information relevant to minimise impact on the environment and ensure optimal life expectancy as regards installation, use and maintenance of the fan.
For custom fans, the information listed in points (a) to (q) shall be provided with the commercial offers provided to the customers instead of on the free access websites.
The information referred to in points 2(a), 2(b), 2(c), 2(d), 2(e) and 2(f) and year of manufacture shall be durably marked on or near the rating plate of the fan, and for point 2(c) one of the following forms of words must be used if applicable:
—
‘A variable speed drive must be installed with this fan’,
—
‘A variable speed drive is integrated within the fan’.
Manufacturers shall provide information in the user manual on specific precautions to be taken when fans are assembled, installed or maintained, including cleaning.
3. Information requirements on partial load or at specified duty
With effect from 24 July 2027, the following requirements shall apply:
1.
For all fans, except custom fans, jet fans and fans with multiple speed motors:
The partial-load operational performance of the fan shall be provided for fans, except custom fans, jet fans and fans with multiple speed motors. This shall be described by a minimum of three performance curves at different speeds: one at the stated inherent speed, one at a lower speed of between 40 % and 50 % of the inherent speed, plus an additional one in the middle (± 10 percentage points) of the other two. More than three curves can be provided, including at any speeds including ones lower than 40 %.
Performance curves shall comprise a sufficient number of test points to permit the characteristic curve to be plotted over the normal operating range.
The information on the curves can be in digital form such as selection software or online catalogue. The values of volume flow, pressure, electric power, fan rotation speed and efficiency shall be provided for the individual test points.
This information shall be available in:
(a)
the technical data sheet or user manual supplied with the fan, unless an internet link or a QR code to that information is supplied with the fan. A pictogram as in ISO 7000:2019 reference n° 1641 is displayed next to the link or QR code;
(b)
the technical documentation for the purposes of conformity assessment pursuant to Article 4;
(c)
the free access websites of the manufacturer of the fan, its authorised representative or the importer.
2.
For custom fans, except jet fans:
The performance or performance curve of custom fans at the specified operating point(s) or operating range(s) shall be provided. A performance curve shall comprise a sufficient number of test points to permit the characteristic curve to be plotted over the normal operating range. The values of volume flow, pressure, electric power and efficiency shall be provided for the individual test points.
This information shall be available in:
(a)
the commercial offers provided to the customers or the technical data sheet or user manual supplied with the fan, unless an internet link or a QR code to that information is supplied with the product. A pictogram as in ISO 7000:2019 reference n° 1641 is displayed next to the link or QR code;
(b)
the technical documentation for the purposes of conformity assessment, pursuant to Article 4.
3.
For jet fans:
The partial-load operational performance of the fan shall be provided for jet fans:
(a)
for jet fans with a single speed motor there is no partial load operation, and no partial load information is required;
(b)
for jet fans without variable speed drives or not intended to be used with variable speed drives, but fitted with a multiple fixed speed motor, the additional operating point is at the lower speed settings;
(c)
for jet fans with a variable speed drive or intended to be used with a variable speed drive the additional data points shall be at 30 % and 50 % of the inherent speed.
For each operating point, the published data shall include thrust, electric input power, rotational speed and efficiency, as a minimum.
This information shall be available in:
(a)
the technical data sheet or user manual supplied with the fan, unless an internet link or a QR code to that information is supplied with the fan. A pictogram as in ISO 7000:2019 reference n° 1641 is displayed next to the link or QR code;
(b)
the technical documentation for the purposes of conformity assessment pursuant to Article 4;
(c)
the free access websites of the manufacturer of the fan, its authorised representative or the importer.
For custom jet fans, the information shall be provided with the commercial offers provided to the customers instead of on the free access websites.
4.
For fans with multiple speed motors except jet fans, the curves shall be provided for the motor’s inherent and minimum speed available to the customer in the same conditions as set out in points 1 and 2 depending on whether or not the fan is a custom fan.
4. Resource efficiency requirements
For fans that are specifically designed and marketed exclusively to be integrated in specific energy-related products covered by ecodesign requirements with respect to spare part availability, the specific provisions of the implementing regulation applicable to the product in question shall apply, for the duration specified therein, in place of the requirements set out in this point.
For custom fans for which spare part availability is addressed in the contract, and which are not covered by the previous paragraph, no specific requirements shall apply.
For other fans, the following requirements shall apply from 24 July 2026:
1.
Availability of spare parts and software updates:
(a)
For all models, units of which are placed on the market as from 24 July 2026, manufacturers, importers or authorised representatives of fans, other than safety critical fans, shall make available to professional repairers at least the following spare parts, if part of the fan, as individual elements or in an assembly when integrated as originally supplied:
(1)
motors of which the rated power is lower than 10 kW;
(2)
motor brushes;
(3)
impellers;
(4)
stator elements;
(5)
mechanical drive components;
(6)
variable speed drives;
(7)
sensors;
(8)
wearing parts (sacrificial elements);
(9)
joints and fixtures required to install these spare parts;
(10)
fan bearings;
(11)
motor bearings when the fan is integrated with the motor above 1 kW.
(b)
For all models, units of which are placed on the market as from 24 July 2026, manufacturers, importers or authorised representatives of safety critical fans shall make available to manufacturer-authorised professional repairers at least the following spare parts, if part of the fan, as individual elements or in an assembly when integrated as originally supplied:
(1)
motors, of which the rated power is lower than 10 kW;
(2)
motor brushes;
(3)
impellers,
(4)
stator elements;
(5)
mechanical drive components;
(6)
variable speed drives;
(7)
sensors;
(8)
wearing parts (sacrificial elements);
(9)
joints and fixtures required to install these spare parts;
(10)
fan bearings;
(11)
motor bearings when the fan is integrated with the motor above 1 kW.
(c)
Availability of spare parts referred to in points (a) and (b) shall be ensured for a minimum period starting at the latest 24 July 2028 or two years after the placing on the market of the first unit of the model, whichever is the later date, and ending at least 10 years after placing on the market the last unit of the model concerned. For that purpose, the list of spare parts, the procedure for ordering them shall be publicly available on the free access website of the manufacturer, importer or authorised representative, at least during the same period and starting at the date referred to in this point. For safety critical fans, the website providing the list of spare parts and the procedure for ordering them and the repair information may be restricted by username and password to manufacturer-authorised professional repairers.
(d)
Maximum delivery time of spare parts:
During the period mentioned in point (c), the manufacturer, importer or authorised representative shall ensure the delivery of the spare parts with the following timeframe:
(1)
as specified in a contract, where a contract exists between the manufacturer and the end user of the fan;
(2)
if not, as specified in the product information of the fan and made available on free access websites;
(3)
if not, then no later than 6 weeks after having received the order.
(e)
Manufacturers, importers or authorised representatives shall ensure that the spare parts mentioned in points (a) and (b) can be replaced without permanent damage to the product.
(f)
When manufacturers, importers or authorised representatives of fans make available software and firmware updates, these shall remain available for a minimum of 10 years after the placing of the last unit of a model on the market, and these software and firmware updates shall be provided free of charge.
2.
Access to repair information:
(a)
During the period referred to in point 1(c) the manufacturer, importer or authorised representative shall provide access to the fan repair information to professional repairers.
The manufacturer’s, importer’s or authorised representative’s website shall indicate the process for professional repairers to request access to information. In order to accept such a request, the manufacturers, importers or authorised representatives may only require the professional repairer to demonstrate that:
(1)
the professional repairer has the technical competence to repair fans and complies with the applicable regulations for repairers of electrical equipment in the Member States where it operates. Reference to an official registration system as professional repairer, where such system is in place in the Member States concerned, shall be accepted as proof of compliance with this point;
(2)
the professional repairer is covered by insurance covering liabilities resulting from its activity regardless of whether this is required by the Member State.
(b)
manufacturers, importers or authorised representatives shall accept or refuse the request referred to in point (a) within 5 working days;
(c)
manufacturers, importers or authorised representatives may charge reasonable and proportionate fees for access to the repair information or for receiving regular updates. A fee is reasonable if it does not discourage access by failing to take into account the extent to which the professional repairer uses the information;
(d)
once the request is accepted, a professional repairer shall have access to the requested repair information within one working day. The information may be provided for an equivalent model or model of the same family, where relevant;
(e)
The repair information shall include:
(1)
the unequivocal appliance identification;
(2)
a disassembly map or exploded view allowing to visualise at least the spare parts made available;
(3)
a technical manual with instructions for repair;
(4)
a list of necessary repair and test equipment including details of any proprietary tool required for repair;
(5)
component and diagnosis information (such as minimum and maximum theoretical values for measurements);
(6)
wiring and connection diagrams;
(7)
diagnostic fault and error codes (including manufacturer-specific codes, where applicable);
(8)
instructions for installation of relevant software and firmware including reset software;
(9)
information on how to access data records of reported failure incidents stored on the product (where applicable).
3.
Requirements for dismantling for material recovery and recycling while avoiding pollution:
(a)
manufacturers, importers or authorised representatives shall ensure that fans are designed in such a way that the materials and components referred to in Annex VII to Directive 2012/19/EU of the European Parliament and of the Council ( 1 ) can be removed with the use of commonly available tools;
(b)
manufacturers, importers and authorised representatives shall fulfil the obligations laid down in Article 15(1) of Directive 2012/19/EU.
5. Material efficiency product information requirements
For a minimum period starting at the latest 24 July 2028 or two years after the placing on the market of the first unit of the model, whichever is the later date, and ending at least 10 years after placing on the market of the last unit of the model concerned, user and installer instructions shall be provided in the form of a user manual on free access websites of manufacturers, importers and authorised representatives, and shall include the following information:
(a)
how to access professional repair services (internet webpages, addresses, contact details);
(b)
relevant information for ordering the spare parts made available to end-users, directly from the manufacturer or through other channels;
(c)
the minimum period during which these spare parts are available;
(d)
the minimum duration of the guarantee of the fan in years;
(e)
details of any proprietary tool required for repair;
(f)
instructions of correct installation;
(g)
instructions for maintenance;
(h)
identification of errors, the meaning of the errors and the action required, including identification of errors requiring professional assistance;
(i)
information on any implications of self-repair or non-professional repair for the safety of the user and for the guarantee.
6. Product information requirements for spare part fans
From 24 July 2026, the packaging (or the product itself in the absence of packaging), the technical data sheet or user manual supplied with the fan, and product information available online and in catalogues shall indicate in a clear and visible manner:
‘This fan does not meet the performance requirements of Regulation (EU) 2024/1834 with regard to ecodesign requirements for fans driven by motors with an electric input power between 125 W and 500 kW, and can only be used to replace a corresponding existing fan placed on the market before 24 July 2026 and integrated into a product, because no compliant fan is fit to be used as a replacement’.
The technical data sheet or user manual supplied with the spare part fan shall provide:
(a)
manufacturer’s name, registered trade name or registered trademark, and the address at which the manufacturer can be contacted;
(b)
the model identifier and, where appropriate, other codes and marks sufficient for the product to be unequivocally and easily identified;
(c)
information relevant for facilitating disassembly, recycling or disposal at end-of-life;
(d)
information relevant to minimise impact on the environment and ensure optimal life expectancy as regards installation, use and maintenance of the fan;
(e)
information about the product or products in which the spare part fan is to be integrated.
( 1 ) Directive 2012/19/EU of the European Parliament and of the Council of 4 July 2012 on waste electrical and electronic equipment (WEEE) ( OJ L 197, 24.7.2012, p. 38 ).