Summary of product characteristics for a biocidal product family
ANNEXSupplementary provisions
ANNEX
Summary of product characteristics for a biocidal product family
Hydrogen Peroxide Group
Product type(s)
PT04: Food and feed area
PT02: Disinfectants and algaecides not intended for direct application to humans or animals
PT03: Veterinary hygiene
Authorisation number: EU-0035039-0000
R4BP asset number: EU-0035039-0000
PART I
FIRST INFORMATION LEVEL
1. ADMINISTRATIVE INFORMATION
1.1. Family name
Name
Hydrogen Peroxide Group
1.2. Product type(s)
Product type(s)
PT04: Food and feed area
PT02: Disinfectants and algaecides not intended for direct application to humans or animals
PT03: Veterinary hygiene
1.3. Authorisation holder
Name and address of the authorisation holder
Name
ARKEMA FRANCE
Address
51, Esplanade du Général de Gaulle 92800 PUTEAUX - LA DEFENSE FR
Authorisation number
EU-0035039-0000
R4BP asset number
EU-0035039-0000
Date of the authorisation
26 February 2026
Expiry date of the authorisation
31 January 2036
1.4. Manufacturer(s) of the product
Name of manufacturer
ARKEMA FRANCE
Address of manufacturer
51, Esplanade du Général de Gaulle 92800 PUTEAUX - LA DEFENSE France
Location of manufacturing sites
ARKEMA FRANCE - USINE DE JARRIE Route National 85 BP 1 38560 JARRIE France
Name of manufacturer
Arkema Gmbh - KIRCHHEIMBOLANDEN
Address of manufacturer
Morschheimer Strasse 19 67292 KIRCHHEIMBOLANDEN Germany
Location of manufacturing sites
ARKEMA GMBH - KIRCHHEIMBOLANDEN Morschheimer Strasse 19 67292 KIRCHHEIMBOLANDEN Germany
Name of manufacturer
ARKEMA GMBH - NIEDERLASSUNG LEUNA
Address of manufacturer
Am Haupttor Bau 2410 06237 LEUNA Germany
Location of manufacturing sites
ARKEMA GMBH - NIEDERLASSUNG LEUNA Am Haupttor Bau 2410 06237 LEUNA Germany
Name of manufacturer
Quimidroga
Address of manufacturer
Tuset 26 08006 Barcelona Spain
Location of manufacturing sites
QUIMIDROGA QG11 Muelle de Inflambles-Delta 1, Port de Lagos, 2-8 Port de LAgos, 2-8 08039 Barcelona Spain
Name of manufacturer
QUIMITÉCNICA.COM – COMÉRCIO E IND. QUÍMICA, SA
Address of manufacturer
Lote 21 B PARQUE INDUSTRIAL DE MIDE 4815-169 LORDELO - GUIMARÃES Portugal
Location of manufacturing sites
Quimitecnica Estarreja Quinta da Indústria - Beduído 3860-680 Estarreja Portugal
Name of manufacturer
RAINOLDI S.p.A.
Address of manufacturer
VIA SAN CARLO BORROMEO snc 24040 LEVATE (BG) Italy
Location of manufacturing sites
Rainoldi SRL Viale dell’industria, 15 21052 Busto Arsizio (VA) Italy
Name of manufacturer
UNIVAR Spa
Address of manufacturer
Viale A. Volta, 49 20090 CUSAGO Italy
Location of manufacturing sites
UNIVAR Spa Viale A. Volta, 49 20090 CUSAGO (MI) Italy
Name of manufacturer
BRENNTAG -midi pyrenees
Address of manufacturer
1038 Avenue des Terres Noires 81370 SAINT SULPICE France
Location of manufacturing sites
BRENNTAG MIDI PYRENEES 1038 Avenue des Terres Noires 81370 SAINT SULPICE France
Name of manufacturer
BRENNTAG LORRAINE
Address of manufacturer
Pôle industriel Toul Europe Secteur A, 2890 Route de Villey St Etienne 2890 Route de Villey St Etienne 54200 TOUL France
Location of manufacturing sites
BRENNTAG LORRAINE Pôle industriel Toul Europe Secteur A, 2890 Route de Villey St Etienne 2890 Route de Villey St Etienne 54200 TOUL France
Name of manufacturer
BRENNTAG NORMANDIE
Address of manufacturer
12 Sente des Jumelles 76710 MONTVILLE France
Location of manufacturing sites
BRENNTAG NORMANDIE 12 Sente des Jumelles 76710 MONTVILLE France
Name of manufacturer
BRENNTAG PICARDIE
Address of manufacturer
ESPACE INDUSTRIEL NORD EIN, 121 Rue Endre Durouchez 121 rue Endre Durouchez 80081 AMIENS France
Location of manufacturing sites
BRENNTAG PICARDIE ESPACE INDUSTRIEL NORD EIN, 121 Rue Endre Durouchez 121 rue Endre Durouchez 80081 AMIENS France
Name of manufacturer
BRENNTAG VAL DE LOIRE
Address of manufacturer
816 rue de Gautray 45590 SAINT CYR EN VAL France
Location of manufacturing sites
BRENNTAG VAL DE LOIRE 816 rue de Gautray 45590 SAINT CYR EN VAL France
Name of manufacturer
BRENNTAG ARDENNES
Address of manufacturer
Route de Tournes CD N° 2 08090 CLIRON France
Location of manufacturing sites
BRENNTAG ARDENNES Route de Tournes CD N° 2 08090 CLIRON France
Name of manufacturer
BRENNTAG MEDITERRANEE
Address of manufacturer
21 Boulevard de l’Europe 13127 VITROLLES France
Location of manufacturing sites
BRENNTAG MEDITERRANEE 21 Boulevard de l’Europe 13127 VITROLLES France
Name of manufacturer
BRENNTAG LOIRE BRETAGNE
Address of manufacturer
14 route de Plessis Bouchet 44802 SAINT HERBLAIN France
Location of manufacturing sites
BRENNTAG LOIRE BRETAGNE 14 route de Plessis Bouchet 44802 SAINT HERBLAIN France
Name of manufacturer
BRENNTAG MAINE BRETAGNE
Address of manufacturer
ZI de la promenade 53290 GREZ EN BOUERE France
Location of manufacturing sites
BRENNTAG MAINE BRETAGNE ZI de la promenade 53290 GREZ EN BOUERE France
Name of manufacturer
BRENNTAG AQUITAINE
Address of manufacturer
20 rue Marcel Sembat 33100 BORDEAUX BASTIDE France
Location of manufacturing sites
BRENNTAG AQUITAINE 20 rue Marcel Sembat 33100 BORDEAUX BASTIDE France
Name of manufacturer
BRENNTAG CHASSIEU
Address of manufacturer
5 rue arago BP 19 69682 CHASSIEU cedex France
Location of manufacturing sites
BRENNTAG CHASSIEU 5 rue arago BP 19 69682 CHASSIEU cedex France
Name of manufacturer
BRENNTAG BOURGOGNE
Address of manufacturer
ZI de Torcy, Avenue des ferrancins Avenue des ferrancins 71210 TORCY France
Location of manufacturing sites
BRENNTAG BOURGOGNE ZI de Torcy, Avenue des ferrancins Avenue des ferrancins 71210 TORCY France
Name of manufacturer
BRENNTAG DAUPHINE
Address of manufacturer
Avenue Jean-Pierre Thimbaud BP306 38434 ECHIROLLES France
Location of manufacturing sites
BRENNTAG DAUPHINE Avenue Jean-Pierre Thimbaud BP306 38434 ECHIROLLES cedex France
Name of manufacturer
BRENNTAG ILE-DE-France
Address of manufacturer
ZAC du closeau Impasse Lavoisier 77220 TOURNAN EN BRIE France
Location of manufacturing sites
BRENNTAG ILE-DE-France ZAC du closeau Impasse Lavoisier 77220 TOURNAN EN BRIE France
Name of manufacturer
BRENNTAG NORD
Address of manufacturer
ZI de la Martinoire BP 40157 59391 WATTRELOOS France
Location of manufacturing sites
BRENNTAG NORD ZI de la Martinoire BP 40157 59391 WATTRELOOS cedex France
Name of manufacturer
BRENNTAG COTE D’AZUR
Address of manufacturer
293 CR n°4 La Roseyre, Zone d’activité économique Zone d’activité économique 06390 LA POINTE DE CONTES France
Location of manufacturing sites
BRENNTAG COTE D’AZUR 293 CR n°4 La Roseyre, Zone d’activité économique Zone d’activité économique 06390 LA POINTE DE CONTES France
Name of manufacturer
CG Chemikalien GmbH & Co. KG
Address of manufacturer
Ulmer Straße 1 30880 Laatzen Germany
Location of manufacturing sites
CG Chemikalien GmbH & Co. KG Ulmer Straße 1 30880 Laatzen Germany
Name of manufacturer
Reher & Ramsden Nachflg. GmbH & Co. KG
Address of manufacturer
Rubbertstraße 44 21109 Hamburg Germany
Location of manufacturing sites
Reher & Ramsden Nachflg. GmbH & Co. KG Rubbertstr. 44 21109 Hamburg Germany
Name of manufacturer
CSC JÄKLECHEMIE GmbH & Co. KG
Address of manufacturer
Matthiasstr. 10 - 12 90431 Nürnberg Germany
Location of manufacturing sites
CSC Jäklechemie GmbH & Co. KG Matthiasstr. 10-12 90257 Nürnberg Germany
Name of manufacturer
Hanke & Seidel Gmbh & Co KG
Address of manufacturer
Waldbadstr. 20-22 33803 Steinhagen Germany
Location of manufacturing sites
Hanke & Seidel GmbH & Co.KG Waldbadstr. 20-22 33803 Steinhagen Germany
Name of manufacturer
Brenntag Polska Sp zo.o
Address of manufacturer
ul. Przemyslowa 2, Jankowice k. Poznaniaul. 62-080 Tarnowo Podgórne Poland
Location of manufacturing sites
Brenntag Polska Sp zo.o Tarnowo Podgórne ul. Przemyslowa 2, Jankowice k. Poznaniaul. 62-080 Tarnowo Podgórne Poland
Name of manufacturer
Brenntag Polska Sp zo.o Góra Kalwaria
Address of manufacturer
ul. Towarowa 6 05-530 Góra Kalwaria Poland
Location of manufacturing sites
Brenntag Polska Sp zo.o Góra Kalwaria ul. Towarowa 6 05-530 Góra Kalwaria Poland
Name of manufacturer
Brenntag Polska Sp zo.o Zgierz
Address of manufacturer
ul. Kwasowa 5 95-100 Zgierz Poland
Location of manufacturing sites
Brenntag Polska Sp zo.o Zgierz ul. Kwasowa 5 95-100 Zgierz Poland
Name of manufacturer
Brenntag Polska Sp zo.o Kedzierzyn-Kozle
Address of manufacturer
ul. J.Bema 21 47-224 Kedzierzyn-Kozle Poland
Location of manufacturing sites
Brenntag Polska Sp zo.o Kedzierzyn-Kozle ul. J.Bema 21 47-224 Kedzierzyn-Kozle Poland
Name of manufacturer
ALLIANCE PRODUCTION
Address of manufacturer
ZA DES RAMASSIERS 4 BD DEODAT DE SEVERAC 31770 COLOMIERS France
Location of manufacturing sites
Groupe QUALLEO Environnement - Alliance Production ZAC des Ramassiers, 4 boulevard Deodat de Séverac 4 boulevard Deodat de Séverac 31770 Colomier France
Name of manufacturer
SAS Celtique Industrielle
Address of manufacturer
Rue brindejonc des moulinais 22190 PLERIN France
Location of manufacturing sites
SAS Celtique Industrielle Rue brindejonc des moulinais 22190 PLERIN France
Name of manufacturer
SOPRODIS
Address of manufacturer
RN133 11200 Lézignan Corbières France
Location of manufacturing sites
SOPRODIS RN133 11200 LEZIGNAN CORBIERES France
Name of manufacturer
RAI
Address of manufacturer
440 Rue de la cimenterie 39300 CHAMPAGNOLE France
Location of manufacturing sites
RAI 440 Rue de la cimenterie 39300 CHAMPAGNOLE France
Name of manufacturer
WIGOL W. Stache GmbH
Address of manufacturer
Textorstrasse 2 67547 WORMS Germany
Location of manufacturing sites
WIGOL W. Stache GmbH Textorstrasse 2 67547 WORMS Germany
Name of manufacturer
L.C.I. sarl
Address of manufacturer
2 ZAC Klengbousbierg 7795 BISSEN Luxembourg
Location of manufacturing sites
L.C.I. sarl 2 ZAC Klengbousbierg 7795 BISSEN Luxembourg
1.5. Manufacturer(s) of the active substance(s)
Active substance
hydrogen peroxide
Name of manufacturer
ARKEMA FRANCE
Address of manufacturer
51, Esplanade du Général de Gaulle 92800 PUTEAUX - LA DEFENSE France
Location of manufacturing sites
ARKEMA FRANCE - USINE DE JARRIE Route National 85 BP 1 38560 JARRIE France
Active substance
hydrogen peroxide
Name of manufacturer
ARKEMA GMBH - NIEDERLASSUNG LEUNA
Address of manufacturer
Am Haupttor Bau 2410 06237 LEUNA Germany
Location of manufacturing sites
ARKEMA GMBH - NIEDERLASSUNG LEUNA Am Haupttor Bau 2410 06237 LEUNA Germany
2. PRODUCT FAMILY COMPOSITION AND FORMULATION
2.1. Qualitative and quantitative information on the composition of the family
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
25 - 49,9 % (w/w)
2.2. Type(s) of formulation
Formulation type(s)
AL Any other liquid
SL Soluble concentrate
PART II
SECOND INFORMATION LEVEL META SPC(S)
1. META SPC 1 ADMINISTRATIVE INFORMATION
1.1. Meta SPC 1 identifier
Identifier
Meta SPC: 1a
1.2. Suffix to the authorisation number
Number
1-1
1.3. Product type(s)
Product type(s)
PT04: Food and feed area
2. META SPC 1 COMPOSITION
2.1. Qualitative and quantitative information on the composition of the meta SPC 1
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
35 –35 % (w/w)
2.2. Type(s) of formulation of the meta SPC 1
Formulation type(s)
AL Any other liquid
3. HAZARD AND PRECAUTIONARY STATEMENTS OF THE META SPC 1
Hazard statements
H272: May intensify fire; oxidiser.
H302: Harmful if swallowed.
H315: Causes skin irritation.
H318: Causes serious eye damage.
H335: May cause respiratory irritation.
H412: Harmful to aquatic life with long lasting effects.
Precautionary statements
P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P220: Keep away from clothing or other combustible materials.
P261: Avoid breathing vapours.
P264: Wash hands thoroughly after handling.
P270: Do not eat, drink or smoke when using this product.
P271: Use only outdoors or in a well-ventilated area.
P273: Avoid release to the environment.
P280: Wear eye protection.
P280: Wear face protection.
P301+P312: IF SWALLOWED: Call a POISON CENTER/doctor if you feel unwell.
P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
P304+P340: IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P310: Immediately call a POISON CENTER/doctor.
P330: Rinse mouth.
P332+P313: If skin irritation occurs: Get medical advice.
P332+P313: If skin irritation occurs: Get medical attention.
P403+P233: Store in a well-ventilated place. Keep container tightly closed.
P405: Store locked up.
4. AUTHORISED USE(S) OF THE META SPC
4.1. Use description
Table 1
Use 1a.4a: Disinfection of food packaging by aseptic technology (bath and spray/vapour)
Product type
PT04: Food and feed area
Target organism(s) (including development stage)
Common name: bacteria
Common name: Bacterial spores
Common name: yeasts
Field(s) of use
indoor use
Disinfection of cardboard or plastic packaging (e.g. bricks, bottles, cups, pouches …) before filling with sensitive food products to be stored at room temperature for a long period
Application method(s)
Method: closed system
Detailed description:
Surfaces must be cleaned before disinfection.
Disinfection of food packaging is achieved by using two different techniques, usually called ‘bath’ and ‘spray’ technologies: ‘bath’ technology: the packaging material (cardboard or plastic rolls) is exposed to a 35 % hydrogen peroxide solution. Disinfection is achieved by heating hydrogen peroxide. The residual hydrogen peroxide on the packaging surface is removed by sterile compressed air. The sterile packaging is then folded, cut, filled with sterile food products and sealed.
‘spray technology’: the packaging material (preformed cardboard containers, plastic bottles and plastic preforms) is exposed to hydrogen peroxide vapor generated from a 35 % hydrogen peroxide solution which is sprayed and then vaporized, ensuring the complete sterilization of the inner surface of the packaging. Further hot sterile air removes hydrogen peroxide residual in the brick or bottle. The sterile packaging is then filled with sterile food products and sealed.
The disinfection machines are closed systems with no access to professionals during operation. In case of maintenance, the machine is stopped, hydrogen peroxide is removed (vapour extraction).
Application rate(s) and frequency
Number and timing of application:
Validated food processing systems that have control over the contaminant load on food packaging surfaces or food processing equipment prior to fill may vary concentration, temperature, and/or contact time to achieve the required level of disinfection. Container volume range (generally from 100 to 2 000 ml) may also influence operating parameters.
Ready-to-use 35 % w/w hydrogen peroxide.
Bath technology:
Contact time: 2,5 seconds minimum
Temperature : 80 °C minimum
Spray technology:
Application rate: 22,7–30 g H 2 O 2 /m 3
Contact time: 2 seconds
Temperature: 115–250 °C
Category(ies) of users
professional
Pack sizes and packaging material
30 kilogram (kg) and 65 kg high-density polyethylene (HDPE) jerrycans
600 litre (L) and 1 000 L HDPE intermediate bulk container (IBC)
4.1.1. Use-specific instructions for use
All surfaces must be cleaned before disinfection.
The user shall always carry out a microbiological validation of the disinfection process in the machine to be used with the devices to be used after which a protocol for disinfection of these machines can be made and used thereafter.
4.1.2. Use-specific risk mitigation measures
This is without prejudice to the application of Council Directive 98/24/EC and other Union legislation in the area of health and safety at work. See section 6 for the full references to this act and the European Standards.
Mixing and loading (automated) or maintenance of the machine:
1.
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 4 is mandatory.
2.
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, polyvinyl chloride (PVC).
3.
The use of eye protection (chemical goggles/face shield) (EN 166 or equivalent) during handling of the product is mandatory.
4.
Wear coverall (EN 13034 or equivalent)
Mixing and loading (manual):
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 10 is mandatory.
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC.
—
The use of eye protection (chemical goggles/face shield) (EN 166 or equivalent) during handling of the product is mandatory.
During use of the machine the following risk mitigation measures (RMMs) apply:
—
All surfaces must be cleaned before disinfection.
—
Machines to be operated in areas where local exhaust ventilation (LEV) or forced ventilation is operational.
—
Wear coverall (EN 13034 or equivalent)
For other instructions, see General directions for use.
4.1.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See General directions for use.
4.1.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
See General directions for use.
4.1.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
See General directions for use.
4.2. Use description
Table 2
Use 1a.11: Disinfection of inner surfaces of aseptic filling machines
Product type
PT04: Food and feed area
Target organism(s) (including development stage)
Common name: bacteria
Common name: Bacterial spores
Common name: yeasts
Field(s) of use
indoor use
Disinfection of inner non-porous surfaces of aseptic filling machines (generally named as ‘aseptic zone’).
Application method(s)
Method: closed system
Detailed description:
Disinfection of the inner surfaces of the filling machines (‘spray’ technologies for the container disinfection) is achieved by vaporizing hydrogen peroxide, ensuring the complete disinfection of the ‘aseptic zone’. The aseptic filling machines are closed systems with no access to professionals during operation. In case of maintenance, the machine is stopped, hydrogen peroxide is removed (vapour extraction).
Application rate(s) and frequency
Number and timing of application:
According to the packaging machine type (manufacturer and model), the biocidal products shall be used at a concentration of 35 % w/w hydrogen peroxide.
Concentration active substance: 16,8 g calculated a.s. in gas phase /m 3
Generation temperature of vapour: minimum 250 °C
Contact time: 24 minutes
Category(ies) of users
professional
Pack sizes and packaging material
600 litre (L) and 1 000 L HDPE intermediate bulk container (IBC)
30 kilogram (kg) and 65 kg high-density polyethylene (HDPE) jerrycans
4.2.1. Use-specific instructions for use
Surfaces must be cleaned before disinfection.
Application rates may vary from one equipment to the other. It is possible to use the product with different decontamination devices or for machines with different volumes.
The user shall always carry out a microbiological validation of the disinfection process in the machine to be used with the devices to be used after which a protocol for disinfection of these machine can be made and used thereafter.
Rinse treated [surfaces/equipment/pipes/machinery] with drinking water after application.
4.2.2. Use-specific risk mitigation measures
This is without prejudice to the application of Council Directive 98/24/EC and other Union legislation in the area of health and safety at work. See section 6 for the full references to this act and the European Standards.
Mixing and loading(automated) or maintenance of the machine:
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 4 is mandatory.
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
Mixing and loading(manual):
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 10 is mandatory.
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC
—
The use of eye protection (chemical goggles/face shield) (EN166) during handling of the product is mandatory.
During use of the machine the following RMMs apply:
—
All surfaces must be cleaned before disinfection.
—
Machines to be operated in areas where LEV or forced ventilation is operational.
For other instructions, see General directions for use.
4.2.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See General directions for use.
4.2.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
See General directions for use.
4.2.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
See General directions for use.
5. GENERAL DIRECTIONS FOR USE OF THE META SPC 1
5.1. Instructions for use
Unless otherwise stated on the label, products must be diluted for use.
Follow the label instructions for use dilutions and application volumes according to the use required.
Surfaces shall be cleaned before disinfection.
See Use-specific instructions for use per use
5.2. Risk mitigation measures
—
No access of third parties during application/treatment/maintenance, unless the required personal protective equipment as prescribed for the professional user is worn.
—
Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m 3 ) or relevant lower national reference value
5.3. Particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
First-Aid measures
IF INHALED: Move to fresh air and keep at rest in a position comfortable for breathing. If symptoms: Call 112/ambulance for medical assistance. If no symptoms: Call a POISON CENTRE or a doctor.
IF SWALLOWED: Immediately rinse mouth. Give something to drink, if exposed person is able to swallow. Do NOT induce vomiting. Call 112/ambulance for medical assistance. Information to Healthcare personnel/doctor: Initiate life support measures if needed, thereafter call a POISON CENTRE.
IF ON SKIN: Immediately wash skin with plenty of water. Thereafter take off all contaminated clothing and wash it before reuse. Continue to wash the skin with water for 15 minutes. Call a POISON CENTRE or a doctor.
IF IN EYES: Immediately rinse with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing for at least 15 minutes. Call 112/ambulance for medical assistance. Information to Healthcare personnel/doctor: The eyes should also be rinsed repeatedly on the way to the doctor if eye exposure to alkaline chemicals (pH > 11), amines and acids like acetic acid, formic acid or propionic acid.
Fire-fighting measures
Extinguishing media:
Suitable extinguishing media: In case of fire involving the product: Water spray Unsuitable extinguishing media: All other extinguishants.
Special hazards arising from the substance or mixture: Contact with combustible material may cause fire. Thermal decomposition gives: Oxygen, that can enhance sites of combustion. Hazards of over-pressurization in containers exposed to heat: explosion risk.
Precautions for fire-fighters: Specific methods: Keep upwind and operate from safe distance. In case of fire, remove exposed containers. Containers/tanks should be cooled with water spray.
Special protective actions for fire-fighters: Wear self-contained breathing apparatus and protective suit.
Accidental release measures
Personal precautions, protective equipment and emergency procedures:
Evacuate non-essential staff and those not equipped with individual protection apparatus. Prohibit contact with eyes. Avoid contact with skin. Avoid inhalation of vapours. Prohibit all sources of sparks and ignition - Do not smoke. If safe to do so, plug or seal off leak. Remove all incompatible substances.
Environmental precautions: Dam up with sand or inert earth (do not use combustible materials). Dilute with large quantities of water before discharging into sewers or into the environment
Methods and materials for containment and cleaning up:
Recovery : Soak up with inert absorbent material. Never reintroduce the spilled product in another container. Risk of decomposition.
Neutralisation : Dilute with water.
Elimination : Dispose of rinse water as waste water.
5.4. Instructions for safe disposal of the product and its packaging
Waste treatment
Disposal of product: Dilute with water.
Disposal of packaging: Clean container with water. Recycle or incinerate at an approved waste disposal site. In accordance with local and national regulations.
5.5. Conditions of storage and shelf-life of the product under normal conditions of storage
Shelf-life of 1 year.
The product should be stored in the original packaging.
Protect from light.
Store below 54 °C.
6. OTHER INFORMATION
Council Directive 98/24/EC of 7 April 1998 on the protection of the health and safety of workers from the risks related to chemical agents at work (fourteenth individual Directive within the meaning of Article 16(1) of Directive 89/391/EEC) ( OJ L 131, 5.5.1998, p. 11 ).
Professionals (including industrial, professionals) mean trained professional if this is required by national legislation.
Please be aware of the European reference value of 1,25 mg/m 3 for the active substance hydrogen peroxide (CAS No.: 7722-84-1) which was used for the risk assessment for the biocidal product (please be aware that relevant lower national limit values may apply).
The full titles of the EN standards referenced in the Risk mitigation measures are:
—
EN 13832 – Footwear protecting against chemicals
—
EN 374 – Protective gloves against dangerous chemicals and micro-organisms
—
EN 405 – Respiratory protective devices
—
EN 166 – Eye protection against chemicals
—
EN 13034 – Protective coverall against liquid chemicals – type 6
7. THIRD INFORMATION LEVEL: INDIVIDUAL PRODUCTS IN THE META SPC 1
7.1. Trade name(s), authorisation number and specific composition of each individual product
Trade name(s)
Peroxal 35 VHP
Market area: EU
VALSTERANE 35 AL1
Market area: EU
VALSTERANE 35 SB
Market area: EU
VALSTERANE 35 AL3
Market area: EU
VALSTERANE 35 AL4
Market area: EU
VALSTERANE 35 B
Market area: EU
VALSTERANE 35 S
Market area: EU
VALSTERANE 35 SHP
Market area: EU
PEROXAL 35 DW
Market area: EU
PEROXAL 35ED
Market area: EU
HYDROCYDE
Market area: EU
ANTISEPT WT 35
Market area: EU
ANTISEPT WS 35
Market area: EU
Authorisation number
EU-0035039-0001 1-1
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
35 % (w/w)
1. META SPC 2 ADMINISTRATIVE INFORMATION
1.1. Meta SPC 2 identifier
Identifier
Meta SPC: 1b
1.2. Suffix to the authorisation number
Number
1-2
1.3. Product type(s)
Product type(s)
PT02: Disinfectants and algaecides not intended for direct application to humans or animals
PT04: Food and feed area
2. META SPC 2 COMPOSITION
2.1. Qualitative and quantitative information on the composition of the meta SPC 2
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
49,9 –49,9 % (w/w)
2.2. Type(s) of formulation of the meta SPC 2
Formulation type(s)
SL Soluble concentrate
3. HAZARD AND PRECAUTIONARY STATEMENTS OF THE META SPC 2
Hazard statements
H272: May intensify fire; oxidiser.
H302: Harmful if swallowed.
H315: Causes skin irritation.
H318: Causes serious eye damage.
H335: May cause respiratory irritation.
H412: Harmful to aquatic life with long lasting effects.
Precautionary statements
P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P220: Keep away from clothing or other combustible materials.
P261: Avoid breathing vapours.
P264: Wash hands thoroughly after handling.
P270: Do not eat, drink or smoke when using this product.
P271: Use only outdoors or in a well-ventilated area.
P273: Avoid release to the environment.
P280: Wear eye protection.
P280: Wear face protection.
P301+P312: IF SWALLOWED: Call a POISON CENTER/doctor if you feel unwell.
P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
P304+P340: IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P310: Immediately call a POISON CENTER/doctor.
P330: Rinse mouth.
P332+P313: If skin irritation occurs: Get medical advice.
P332+P313: If skin irritation occurs: Get medical attention.
P403+P233: Store in a well-ventilated place. Keep container tightly closed.
P405: Store locked up.
4. AUTHORISED USE(S) OF THE META SPC
4.1. Use description
Table 1
Use 1b.3: Disinfection of equipment by filling or immersion
Product type
PT02: Disinfectants and algaecides not intended for direct application to humans or animals
PT04: Food and feed area
Target organism(s) (including development stage)
Common name: bacteria
Common name: yeasts
Common name: fungi
Field(s) of use
indoor use
outdoor use
Disinfection of equipments (e.g. pipes, tanks, fillers, mixers, boxes …) by filling with solution (disinfection of inner surfaces), or immersion in a solution (inner/outer disinfection) in industrial (e.g. cosmetics, chemical synthesis …), institutional, food and feed areas.
Application method(s)
Method: open system: immersion
Detailed description:
Filling or immersion. Equipment surfaces must be cleaned before disinfection.
Application rate(s) and frequency
Number and timing of application:
The product shall be diluted to 10 % (active substance w/w) prior to use.
The contact time is 5 minutes for bacteria, yeasts, and fungi.
The diluted solution should be at room temperature.
Frequency: once a day
Category(ies) of users
professional
Pack sizes and packaging material
600 litre (L) and 1 000 L HDPE intermediate bulk container (IBC)
220 L HDPE Drum
30 kilogram (kg) and 65 kg high-density polyethylene (HDPE) jerrycans
4.1.1. Use-specific instructions for use
Thoroughly clean and rinse the surface. Remove excess water from the surface before disinfection.
The product is diluted manually or automatic to 10 % hydrogen peroxide by professionals for application.
Automatic dilution (IBC, drum): The product is pumped into an intermediate reservoir where it is mixed with water to the required dose. There is no manual dilution step.
Manual dilution (jerry can): Product dilution to the in-use concentration is achieved by an operator in a bucket or intermediate small reservoir.
The diluted solution is then either used in a bath (disinfection by immersion) or poured into the equipment to be disinfected (disinfection by filling).
Rinse treated [surfaces/equipment/pipes/machinery] with drinking water after application.
Solutions shall be disposed of after a single use
4.1.2. Use-specific risk mitigation measures
This is without prejudice to the application of Council Directive 98/24/EC and other Union legislation in the area of health and safety at work. See section 6 for the full references to this act and the European Standards.
Mixing and loading (automated):
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 4 is mandatory.
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
—
Wear coverall (EN 13034 or equivalent)
Mixing and loading (manual):
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 10 is mandatory.
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
—
Wear coverall (EN 13034 or equivalent)
Disinfection of equipment by filling or immersion:
—
Ensure that application is carried out in areas with a minimum ventilation of 4 air changes per hour.
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 20 is mandatory.
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
—
The bath must be emptied directly after the contact time and removal of equipment.
—
Leave the room directly after application.
4.1.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See General directions for use.
4.1.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
See General directions for use.
4.1.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
See General directions for use.
4.2. Use description
Table 2
Use 1b.4a: Disinfection of food packaging by aseptic technology (bath and spray/vapour)
Product type
PT04: Food and feed area
Target organism(s) (including development stage)
Common name: bacteria
Common name: Bacterial spores
Common name: yeasts
Field(s) of use
indoor use
Disinfection of cardboard or plastic packaging (e.g. bricks, bottles, cups, pouches …) before filling with sensitive food products to be stored at room temperature for a long period
Application method(s)
Method: closed system
Detailed description:
Surfaces must be cleaned before disinfection. Disinfection of food packaging is achieved by using two different techniques, usually called ‘bath’ and ‘spray’ technologies:
‘bath’ technology: the packaging material (cardboard or plastic rolls) is exposed to a 35 % hydrogen peroxide solution. Disinfection is achieved by heating hydrogen peroxide. The residual hydrogen peroxide on the packaging surface is removed by sterile compressed air. The sterile packaging is then folded, cut, filled with sterile food products and sealed.
‘spray technology’: the packaging material (preformed cardboard containers, plastic bottles and plastic preforms) is exposed to hydrogen peroxide vapor generated from a 35 % hydrogen peroxide solution which is sprayed and then vaporized, ensuring the complete sterilization of the inner surface of the packaging. Further hot sterile air removes hydrogen peroxide residual in the brick or bottle. The sterile packaging is then filled with sterile food products and sealed.
The disinfection machines are closed systems with no access to professionals during operation. In case of maintenance, the machine is stopped, hydrogen peroxide is removed (vapour extraction).
Application rate(s) and frequency
Number and timing of application:
Validated food processing systems that have control over the contaminant load on food packaging surfaces or food processing equipment prior to fill may vary concentration, temperature, and/or contact time to achieve the required level of disinfection. Container volume range (generally from 100 to 2 000 ml) may also influence operating parameters.
Dilute the product to 35 % w/w hydrogen peroxide before use.
Bath technology:
Contact time: 2,5 seconds minimum
Temperature : 80 °C minimum
Spray technology:
Application rate: 22,7–30 g H 2 O 2 /m 3
Contact time: 2 seconds
Temperature: 115–250 °C
Category(ies) of users
professional
Pack sizes and packaging material
600 litre (L) and 1 000 L HDPE intermediate bulk container (IBC)
30 kilogram (kg) and 65 kg high-density polyethylene (HDPE) jerrycans
4.2.1. Use-specific instructions for use
All surfaces must be cleaned before disinfection.
The user shall always carry out a microbiological validation of the disinfection process in the machine to be used with the devices to be used after which a protocol for disinfection of these machine can be made and used thereafter.
4.2.2. Use-specific risk mitigation measures
This is without prejudice to the application of Council Directive 98/24/EC and other Union legislation in the area of health and safety at work. See section 6 for the full references to this act and the European Standards.
Mixing and loading (automated) or maintenance of the machine:
1.
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 4 is mandatory.
2.
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, polyvinyl chloride (PVC).
3.
The use of eye protection (chemical goggles/face shield) (EN 166 or equivalent) during handling of the product is mandatory.
4.
Wear coverall (EN 13034 or equivalent)
Mixing and loading (manual):
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 10 is mandatory.
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC.
—
The use of eye protection (chemical goggles/face shield) (EN 166 or equivalent) during handling of the product is mandatory.
During use of the machine the following risk mitigation measures (RMMs) apply:
—
All surfaces must be cleaned before disinfection.
—
Machines to be operated in areas where local exhaust ventilation (LEV) or forced ventilation is operational.
—
Wear coverall (EN 13034 or equivalent)
For other instructions, see General directions for use.
4.2.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See General directions for use.
4.2.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
See General directions for use.
4.2.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
See General directions for use.
4.3. Use description
Table 3
Use 1b.5: Disinfection of inner surfaces of food and feed processing systems (including Cleaning-In-Place, CIP) and veterinary water systems
Product type
PT04: Food and feed area
Target organism(s) (including development stage)
Common name: Bacterial spores
Common name: fungi
Common name: bacteria
Common name: yeasts
Field(s) of use
indoor use
Disinfection of inner surfaces of pipes, pumps, valves, filters, tanks, fillers and other machines in contact with food or feed by filling or circulating a solution (including CIP Cleaning-In-Place) in food and feed processing systems. Disinfection of inner surfaces in veterinary drinking water systems (e.g. pipes, tanks, valves).
Application method(s)
Method: open system
Detailed description:
Equipment or system surfaces must be cleaned before disinfection. Automatic dilution (IBC, drum): The product is pumped into an intermediate reservoir where it is mixed with water to the required dose. Manual dilution (jerry can): Product dilution to the in-use concentration is achieved by an operator in a bucket or intermediate small reservoir. The diluted solution is then either automatically pumped into closed process systems or poured manually into the equipment/system to be disinfected. Disinfection is achieved either by filling without recirculation or with recirculation (Cleaning-In-Place CIP). Rinse treated [surfaces/equipment/pipes/machinery] with drinking water after application.
Application rate(s) and frequency
Number and timing of application:
For bacteria, yeasts and fungi: the product shall be diluted to 1,5 % (active substance w/w) prior to use.
Temperature: 20 °C.
The contact time is:
—
5 minutes for bacteria and yeasts
—
15 minutes for fungi
Bacterial spores: the product shall be diluted to 8 % (active substance content w/w) prior to use. The contact time is 60 minutes.
Frequency: once a day
Category(ies) of users
professional
Pack sizes and packaging material
220 L HDPE Drum
600 litre (L) and 1 000 L HDPE intermediate bulk container (IBC)
30 kilogram (kg) and 65 kg high-density polyethylene (HDPE) jerrycans
4.3.1. Use-specific instructions for use
Thoroughly clean and rinse the surface. Remove excess water from the surface before disinfection
The drinking water system shall not be in use during disinfection. The product shall be diluted before use (automated or manual dilution in a bucket or reservoir) before pumping or pouring into the closed system. Disinfection is achieved either by filling without recirculation or with recirculation.
4.3.2. Use-specific risk mitigation measures
This is without prejudice to the application of Council Directive 98/24/EC and other Union legislation in the area of health and safety at work. See section 6 for the full references to this act and the European Standards.
Mixing and loading(automated) or maintenance of the machine:
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 4 is mandatory.
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
—
Wear coverall (EN 13034 or equivalent)
Mixing and loading(manual):
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 10 is mandatory.
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
—
Wear coverall (EN 13034 or equivalent)
4.3.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See General directions for use.
4.3.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
See General directions for use.
4.3.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
See General directions for use.
5. GENERAL DIRECTIONS FOR USE OF THE META SPC 2
5.1. Instructions for use
Unless otherwise stated on the label, products must be diluted for use.
Follow the label instructions for use dilutions and application volumes according to the use required.
Surfaces shall be cleaned before disinfection.
See Use-specific instructions for use per use
5.2. Risk mitigation measures
—
No access of third parties during application/treatment/maintenance, unless the required personal protective equipment as prescribed for the professional user is worn.
—
Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m 3 ) or relevant lower national reference value
5.3. Particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
First-Aid measures
IF INHALED: Move to fresh air and keep at rest in a position comfortable for breathing. If symptoms: Call 112/ambulance for medical assistance. If no symptoms: Call a POISON CENTRE or a doctor.
IF SWALLOWED: Immediately rinse mouth. Give something to drink, if exposed person is able to swallow. Do NOT induce vomiting. Call 112/ambulance for medical assistance. Information to Healthcare personnel/doctor: Initiate life support measures if needed, thereafter call a POISON CENTRE.
IF ON SKIN: Immediately wash skin with plenty of water. Thereafter take off all contaminated clothing and wash it before reuse. Continue to wash the skin with water for 15 minutes. Call a POISON CENTRE or a doctor.
IF IN EYES: Immediately rinse with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing for at least 15 minutes. Call 112/ambulance for medical assistance. Information to Healthcare personnel/doctor: The eyes should also be rinsed repeatedly on the way to the doctor if eye exposure to alkaline chemicals (pH > 11), amines and acids like acetic acid, formic acid or propionic acid.
Fire-fighting measures
Extinguishing media:
Suitable extinguishing media: In case of fire involving the product: Water spray Unsuitable extinguishing media: All other extinguishants.
Special hazards arising from the substance or mixture: Contact with combustible material may cause fire. Thermal decomposition gives: Oxygen, that can enhance sites of combustion. Hazards of over-pressurization in containers exposed to heat: explosion risk.
Precautions for fire-fighters: Specific methods: Keep upwind and operate from safe distance. In case of fire, remove exposed containers. Containers/tanks should be cooled with water spray.
Special protective actions for fire-fighters: Wear self-contained breathing apparatus and protective suit.
Accidental release measures
Personal precautions, protective equipment and emergency procedures:
Evacuate non-essential staff and those not equipped with individual protection apparatus. Prohibit contact with eyes. Avoid contact with skin. Avoid inhalation of vapours. Prohibit all sources of sparks and ignition - Do not smoke. If safe to do so, plug or seal off leak. Remove all incompatible substances.
Environmental precautions: Dam up with sand or inert earth (do not use combustible materials). Dilute with large quantities of water before discharging into sewers or into the environment
Methods and materials for containment and cleaning up:
Recovery: Soak up with inert absorbent material. Never reintroduce the spilled product in another container. Risk of decomposition.
Neutralisation: Dilute with water.
Elimination: Dispose of rinse water as waste water.
5.4. Instructions for safe disposal of the product and its packaging
Waste treatment
Disposal of product: Dilute with water.
Disposal of packaging: Clean container with water. Recycle or incinerate at an approved waste disposal site. In accordance with local and national regulations.
5.5. Conditions of storage and shelf-life of the product under normal conditions of storage
Shelf-life of 1 year.
The product should be stored in the original packaging.
Protect from light.
Store below 54 °C.
6. OTHER INFORMATION
Council Directive 98/24/EC of 7 April 1998 on the protection of the health and safety of workers from the risks related to chemical agents at work (fourteenth individual Directive within the meaning of Article 16(1) of Directive 89/391/EEC) ( OJ L 131, 5.5.1998, p. 11 ).
Professionals (including industrial, professionals) mean trained professional if this is required by national legislation.
Please be aware of the European reference value of 1,25 mg/m 3 for the active substance hydrogen peroxide (CAS No.: 7722-84-1) which was used for the risk assessment for the biocidal product (please be aware that relevant lower national limit values may apply).
The full titles of the EN standards referenced in the Risk mitigation measures are:
—
EN 13832 – Footwear protecting against chemicals
—
EN 374 – Protective gloves against dangerous chemicals and micro-organisms
—
EN 405 – Respiratory protective devices
—
EN 166 – Eye protection against chemicals
—
EN 13034 – Protective coverall against liquid chemicals – type 6
7. THIRD INFORMATION LEVEL: INDIVIDUAL PRODUCTS IN THE META SPC 2
7.1. Trade name(s), authorisation number and specific composition of each individual product
Trade name(s)
Antisept WS 50
Market area: EU
Antisept WT 50
Market area: EU
Authorisation number
EU-0035039-0002 1-2
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
49,9 % (w/w)
7.2. Trade name(s), authorisation number and specific composition of each individual product
Trade name(s)
VALSTERANE 50 AL4
Market area: EU
VALSTERANE 50 B
Market area: EU
PEROXAL 50 DW
Market area: EU
PEROXAL 50 VHP
Market area: EU
PEROXAL 50 ED
Market area: EU
Authorisation number
EU-0035039-0003 1-2
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
49,9 % (w/w)
1. META SPC 3 ADMINISTRATIVE INFORMATION
1.1. Meta SPC 3 identifier
Identifier
Meta SPC: 2
1.2. Suffix to the authorisation number
Number
1-3
1.3. Product type(s)
Product type(s)
PT02: Disinfectants and algaecides not intended for direct application to humans or animals
PT04: Food and feed area
PT03: Veterinary hygiene
2. META SPC 3 COMPOSITION
2.1. Qualitative and quantitative information on the composition of the meta SPC 3
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
>=35 –<=49,9 % (w/w)
2.2. Type(s) of formulation of the meta SPC 3
Formulation type(s)
SL Soluble concentrate
3. HAZARD AND PRECAUTIONARY STATEMENTS OF THE META SPC 3
Hazard statements
H272: May intensify fire; oxidiser.
H302: Harmful if swallowed.
H315: Causes skin irritation.
H318: Causes serious eye damage.
H335: May cause respiratory irritation.
H412: Harmful to aquatic life with long lasting effects.
Precautionary statements
P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P220: Keep away from clothing or other combustible materials.
P261: Avoid breathing vapours.
P264: Wash hands thoroughly after handling.
P270: Do not eat, drink or smoke when using this product.
P271: Use only outdoors or in a well-ventilated area.
P273: Avoid release to the environment.
P280: Wear eye protection.
P280: Wear face protection.
P301+P312: IF SWALLOWED: Call a POISON CENTER/doctor if you feel unwell.
P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
P304+P340: IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P310: Immediately call a POISON CENTER/doctor.
P330: Rinse mouth.
P332+P313: If skin irritation occurs: Get medical advice.
P332+P313: If skin irritation occurs: Get medical attention.
P403+P233: Store in a well-ventilated place. Keep container tightly closed.
P405: Store locked up.
4. AUTHORISED USE(S) OF THE META SPC
4.1. Use description
Table 1
Use 2.2: Hard surface disinfection
Product type
PT02: Disinfectants and algaecides not intended for direct application to humans or animals
PT04: Food and feed area
Target organism(s) (including development stage)
Common name: bacteria
Common name: yeasts
Common name: fungi
Field(s) of use
indoor use
outdoor use
Disinfection of non-porous hard surfaces (tables, floors, walls, hard furniture, equipment), by wiping, moping or using a hand held trigger spray in:
—
Hospitals, health care facilities, industries, institutions … (PT2)
—
Food and feed industry, kitchens, restaurants, abattoirs… (PT4)
Application method(s)
Method: manual application
Detailed description:
Wiping or mopping with a soaked cloth, or spraying with a trigger sprayer.
Application rate(s) and frequency
Number and timing of application:
For bacteria, yeasts and fungi: the product shall be diluted to 1,5 % (expressed as active substance content in % w/w) prior to use. Application rate: 300 ml/m 2 .
The minimum contact time is:
—
5 minutes for bacteria and yeasts
—
15 minutes for fungi.
Frequency: once a day
Apply the product at room temperature.
Category(ies) of users
professional
Pack sizes and packaging material
30 kilogram (kg) and 65 kg high-density polyethylene (HDPE) jerrycans
1L and 5L HDPE bottle
4.1.1. Use-specific instructions for use
Thoroughly clean and rinse the surface. Remove excess water from the surface before disinfection, if appropriate.
Manual dilution (jerry can, bottle): Product dilution to the in-use concentration of 1,5 % hydrogen peroxide (w/w) is achieved by an operator in a bucket or small intermediate reservoir.
Wiping and mopping
Soak the wipe or mop with product until completely soaked and then wipe or mop the surface to be disinfected. Make sure to wet the surfaces completely.
Spraying
Fill a hand held sprayer with the diluted solution. Make sure to wet surfaces completely by spraying the product onto the surface to be disinfected.
Allow to take effect for at least the required contact time.
4.1.2. Use-specific risk mitigation measures
This is without prejudice to the application of Council Directive 98/24/EC and other Union legislation in the area of health and safety at work. See section 6 for the full references to this act and the European Standards.
Mixing and loading (manual):
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 10 is mandatory.
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
Wiping and trigger spray application:
—
Ensure that application is carried out in areas with a minimum ventilation of 4 air changes per hour.
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 4 is mandatory.
—
Leave the room directly after application.
Mopping application:
—
Ensure that application is carried out in areas with a minimum ventilation of 4 air changes per hour.
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 10 is mandatory.
—
Leave the room directly after application.
4.1.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See General directions for use.
4.1.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
See General directions for use.
4.1.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
See General directions for use.
4.2. Use description
Table 2
Use 2.5: Disinfection of inner surfaces of food and feed processing systems (including Cleaning-In-Place, CIP) and veterinary water systems
Product type
PT04: Food and feed area
Target organism(s) (including development stage)
Common name: Bacterial spores
Common name: fungi
Common name: bacteria
Common name: yeasts
Field(s) of use
indoor use
Disinfection of inner surfaces of pipes, pumps, valves, filters, tanks, fillers and other machines in contact with food or feed by filling or circulating a solution (including CIP Cleaning-In-Place) in food and feed processing systems. Disinfection of inner surfaces in veterinary drinking water systems (e.g. pipes, tanks, valves).
Application method(s)
Method: open system
Detailed description:
Equipment or system surfaces must be cleaned before disinfection. Automatic dilution (IBC, drum): The product is pumped into an intermediate reservoir where it is mixed with water to the required dose. Manual dilution (jerry can): Product dilution to the in-use concentration is achieved by an operator in a bucket or intermediate small reservoir.The diluted solution is then either automatically pumped into closed process systems or poured manually into the equipment/system to be disinfected. Disinfection is achieved either by filling without recirculation or with recirculation (Cleaning-In-Place CIP).Rinse treated [surfaces/equipment/pipes/machinery] with drinking water after application.
Application rate(s) and frequency
Number and timing of application:
For bacteria, yeasts and fungi: the product shall be diluted to 1,5 % (active substance w/w) prior to use.
Temperature: 20 °C.
The contact time is:
—
5 minutes for bacteria and yeasts
—
15 minutes for fungi
Bacterial spores: the product shall be diluted to 8 % (active substance content w/w) prior to use. The contact time is 60 minutes.
Frequency: once a day
Category(ies) of users
professional
Pack sizes and packaging material
220 L HDPE Drum
600 litre (L) and 1 000 L HDPE intermediate bulk container (IBC)
30 kilogram (kg) and 65 kg high-density polyethylene (HDPE) jerrycans
4.2.1. Use-specific instructions for use
Thoroughly clean and rinse the surface. Remove excess water from the surface before disinfection
The drinking water system shall not be in use during disinfection. The product shall be diluted before use (automated or manual dilution in a bucket or reservoir) before pumping or pouring into the closed system. Disinfection is achieved either by filling without recirculation or with recirculation.
4.2.2. Use-specific risk mitigation measures
This is without prejudice to the application of Council Directive 98/24/EC and other Union legislation in the area of health and safety at work. See section 6 for the full references to this act and the European Standards.
Mixing and loading(automated) or maintenance of the machine:
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 4 is mandatory.
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
—
Wear coverall (EN 13034 or equivalent)
Mixing and loading(manual):
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 10 is mandatory.
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
—
Wear coverall (EN 13034 or equivalent)
4.2.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See General directions for use.
4.2.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
See General directions for use.
4.2.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
See General directions for use.
4.3. Use description
Table 3
Use 2.6: Disinfection of hard surface by spraying for veterinary purpose
Product type
PT03: Veterinary hygiene
Where relevant, an exact description of the authorised use
Target organism(s) (including development stage)
Common name: bacteria
Common name: yeasts
Common name: fungi
Common name: viruses
Field(s) of use
indoor use
outdoor use
Porous and non-porous hard surfaces in animal husbandry (animal houses, pens), including tables, floors, walls, machinery, hard furniture and equipment, excluding outer surfaces of animal transportation.
Application method(s)
Method: open system: spray treatment
Detailed description:
Surfaces must be cleaned before disinfection. Disinfection of equipment by spraying (medium pressure); A portable spraying equipment (volume ~ 20 Litres, medium pressure, hand held) is filled with the product dilution and then used for disinfection. Manual dilution (jerry can): Product dilution to the in-use concentration is achieved by an operator in a bucket or spray reservoir. Surfaces must kept wet during disinfection.
Application rate(s) and frequency
Number and timing of application:
Prior to use, the product shall be diluted to (all concentrations are expressed as active substance content % w/w):
—
2 % for porous surfaces in animal husbandry
—
1,5 % for non-porous surfaces in animal husbandry
Application rate: 300 ml/m 2 .
The minimum contact time is:
—
30 minutes for porous and non-porous surfaces in animal husbandry
Frequency: once a week for porous and non-porous surfaces in animal husbandry.
Category(ies) of users
professional
Pack sizes and packaging material
30 kilogram (kg) and 65 kg high-density polyethylene (HDPE) jerrycans
4.3.1. Use-specific instructions for use
Clean surfaces before use.
Dose the concentrate in the reservoir of the pressure cleaner to obtain an in-use concentration of:
—
2 % for porous surfaces in animal husbandry
—
1,5 % for non-porous surfaces in animal husbandry
Use a pressure washer or other mechanical sprayer to apply the diluted solution at an application rate of 300 ml spray /m 2 . The disinfection solution shall remain in contact with the surface to be disinfected for at least:
30 minutes for porous and non-porous surfaces in animal husbandry
4.3.2. Use-specific risk mitigation measures
This is without prejudice to the application of Council Directive 98/24/EC and other Union legislation in the area of health and safety at work. See section 6 for the full references to this act and the European Standards.
Mixing and loading (automated):
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 4 is mandatory.
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
—
Wear coverall (EN 13034 or equivalent)
Mixing and loading (manual):
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 10 is mandatory.
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
—
Wear coverall (EN 13034 or equivalent)
Spraying, hard surfaces:
—
Ensure that application is carried out in areas with a minimum ventilation of 4 air changes per hour.
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 20 is mandatory.
—
Animals are not allowed to be present during treatment
—
Do not allow re-entry of animals to the disinfected facilities before 15 minutes after disinfection.
—
Leave the room directly after application.
4.3.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See General directions for use.
4.3.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
See General directions for use.
4.3.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
See General directions for use.
4.4. Use description
Table 4
Use 2.10: Disinfection of hard surfaces by medium pressure spraying
Product type
PT02: Disinfectants and algaecides not intended for direct application to humans or animals
PT04: Food and feed area
Target organism(s) (including development stage)
Common name: bacteria
Common name: yeasts
Common name: fungi
Field(s) of use
indoor use
outdoor use
Non-porous hard surfaces (e.g. floors, walls, work surfaces including food contact surfaces) in industry, institutions and health care facilities.
Application method(s)
Method: open system: spray treatment
Detailed description:
Surfaces must be cleaned before disinfection. Disinfection of equipment by spraying (medium pressure);
A portable spraying equipment (volume ~ 20 Liters, medium pressure, hand held) is filled with the product dilution and then used for disinfection.
Application rate(s) and frequency
Number and timing of application:
For bacteria and yeasts and fungi, the product shall be diluted to 1,5 % (active substance % w/w) prior to use.
The minimum contact time is:
—
5 minutes for bacteria and yeasts
—
15 minutes for fungi.
Application rate: 300 ml/m 2
Apply the product at room temperature
Frequency: once a day
Category(ies) of users
professional
Pack sizes and packaging material
220 L HDPE Drum
600 litre (L) and 1 000 L HDPE intermediate bulk container (IBC)
30 kilogram (kg) and 65 kg high-density polyethylene (HDPE) jerrycans
4.4.1. Use-specific instructions for use
Thoroughly clean and rinse the surface. Remove excess water from the surface before disinfection.
Dose the concentrate in the reservoir of the pressure cleaner to obtain a suitable in-use concentration of the active substance (see application rate section).
Automatic dilution (IBC, drum): The product is pumped into the reservoir of the pressure cleaner where it is mixed with water to the required dose. There is no manual dilution step.
Manual dilution (jerry can): Product dilution to the in-use concentration is achieved by an operator in a bucket or spray reservoir.
Surfaces must kept wet during disinfection.
Use a pressure washer or other mechanical sprayer to apply the diluted solution at an application rate of 300 ml/m 2 . The disinfection solution shall remain in contact with the surface to be disinfected 5 minutes for removal of bacteria and yeasts, and 15 minutes to remove fungi.
Premises shall be well-ventilated before re-entry
4.4.2. Use-specific risk mitigation measures
This is without prejudice to the application of Council Directive 98/24/EC and other Union legislation in the area of health and safety at work. See section 6 for the full references to this act and the European Standards.
Mixing and loading (automated):
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 4 is mandatory.
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
Mixing and loading (manual):
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 10 is mandatory.
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
Spraying of hard surfaces:
—
Ensure that application is carried out in areas with a minimum ventilation of 4 air changes per hour.
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 20 is mandatory.
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
4.4.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See General directions for use.
4.4.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
See General directions for use.
4.4.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
See General directions for use.
5. GENERAL DIRECTIONS FOR USE OF THE META SPC 3
5.1. Instructions for use
Unless otherwise stated on the label, products must be diluted for use.
Follow the label instructions for use dilutions and application volumes according to the use required.
Surfaces shall be cleaned before disinfection.
See Use-specific instructions for use per use
5.2. Risk mitigation measures
—
No access of third parties during application/treatment/maintenance, unless the required personal protective equipment as prescribed for the professional user is worn.
—
Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m 3 ) or relevant lower national reference value
5.3. Particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
First-Aid measures
IF INHALED: Move to fresh air and keep at rest in a position comfortable for breathing. If symptoms: Call 112/ambulance for medical assistance. If no symptoms: Call a POISON CENTRE or a doctor.
IF SWALLOWED: Immediately rinse mouth. Give something to drink, if exposed person is able to swallow. Do NOT induce vomiting. Call 112/ambulance for medical assistance. Information to Healthcare personnel/doctor: Initiate life support measures if needed, thereafter call a POISON CENTRE.
IF ON SKIN: Immediately wash skin with plenty of water. Thereafter take off all contaminated clothing and wash it before reuse. Continue to wash the skin with water for 15 minutes. Call a POISON CENTRE or a doctor.
IF IN EYES: Immediately rinse with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing for at least 15 minutes. Call 112/ambulance for medical assistance. Information to Healthcare personnel/doctor: The eyes should also be rinsed repeatedly on the way to the doctor if eye exposure to alkaline chemicals (pH > 11), amines and acids like acetic acid, formic acid or propionic acid
Fire-fighting measures
Extinguishing media:
Suitable extinguishing media: In case of fire involving the product: Water spray Unsuitable extinguishing media: All other extinguishants.
Special hazards arising from the substance or mixture: Contact with combustible material may cause fire. Thermal decomposition gives: Oxygen, that can enhance sites of combustion. Hazards of over-pressurization in containers exposed to heat: explosion risk.
Precautions for fire-fighters: Specific methods: Keep upwind and operate from safe distance. In case of fire, remove exposed containers. Containers/tanks should be cooled with water spray.
Special protective actions for fire-fighters: Wear self-contained breathing apparatus and protective suit.
Accidental release measures
Personal precautions, protective equipment and emergency procedures:
Evacuate non-essential staff and those not equipped with individual protection apparatus. Prohibit contact with eyes. Avoid contact with skin. Avoid inhalation of vapours. Prohibit all sources of sparks and ignition - Do not smoke. If safe to do so, plug or seal off leak. Remove all incompatible substances.
Environmental precautions: Dam up with sand or inert earth (do not use combustible materials). Dilute with large quantities of water before discharging into sewers or into the environment
Methods and materials for containment and cleaning up:
Recovery : Soak up with inert absorbent material. Never reintroduce the spilled product in another container. Risk of decomposition.
Neutralisation : Dilute with water.
Elimination : Dispose of rinse water as waste water.
5.4. Instructions for safe disposal of the product and its packaging
Waste treatment:
Disposal of product: Dilute with water.
Disposal of packaging: Clean container with water. Recycle or incinerate at an approved waste disposal site. In accordance with local and national regulations.
5.5. Conditions of storage and shelf-life of the product under normal conditions of storage
Shelf-life of 1 year.
The product should be stored in the original packaging.
Protect from light.
Store below 54 °C.
6. OTHER INFORMATION
Council Directive 98/24/EC of 7 April 1998 on the protection of the health and safety of workers from the risks related to chemical agents at work (fourteenth individual Directive within the meaning of Article 16(1) of Directive 89/391/EEC) ( OJ L 131, 5.5.1998, p. 11 ).
Professionals (including industrial, professionals) mean trained professional if this is required by national legislation.
Please be aware of the European reference value of 1,25 mg/m 3 for the active substance hydrogen peroxide (CAS No.: 7722-84-1) which was used for the risk assessment for the biocidal product (please be aware that relevant lower national limit values may apply).
The full titles of the EN standards referenced in the Risk mitigation measures are:
—
EN 13832 – Footwear protecting against chemicals
—
EN 374 – Protective gloves against dangerous chemicals and micro-organisms
—
EN 405 – Respiratory protective devices
—
EN 166 – Eye protection against chemicals
—
EN 13034 – Protective coverall against liquid chemicals – type 6
7. THIRD INFORMATION LEVEL: INDIVIDUAL PRODUCTS IN THE META SPC 3
7.1. Trade name(s), authorisation number and specific composition of each individual product
Trade name(s)
OXMAVI
Market area: EU
Authorisation number
EU-0035039-0004 1-3
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
35 % (w/w)
7.2. Trade name(s), authorisation number and specific composition of each individual product
Trade name(s)
A CID HIS
Market area: EU
Authorisation number
EU-0035039-0005 1-3
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
35 % (w/w)
7.3. Trade name(s), authorisation number and specific composition of each individual product
Trade name(s)
HD 20 OXYGERMS
Market area: EU
HD 20S OXY GERMS SPRAY
Market area: EU
HD 22 AGRI GERMS
Market area: EU
Authorisation number
EU-0035039-0006 1-3
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
35 % (w/w)
7.4. Trade name(s), authorisation number and specific composition of each individual product
Trade name(s)
Hydrosan
Market area: EU
Authorisation number
EU-0035039-0007 1-3
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
35 % (w/w)
7.5. Trade name(s), authorisation number and specific composition of each individual product
Trade name(s)
162 Combitartre
Market area: EU
Authorisation number
EU-0035039-0008 1-3
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
35 % (w/w)
7.6. Trade name(s), authorisation number and specific composition of each individual product
Trade name(s)
Antisept WO 35
Market area: EU
Authorisation number
EU-0035039-0009 1-3
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
35 % (w/w)
7.7. Trade name(s), authorisation number and specific composition of each individual product
Trade name(s)
PEROXAL 35 AHS
Market area: EU
PEROXAL 35 DS
Market area: EU
PEROXAL 35 PG
Market area: EU
PEROXAL 35 HSD
Market area: EU
PEROXAL 35 SD
Market area: EU
ALBONE 35 S
Market area: EU
PEROXAL 35 CIP
Market area: EU
Authorisation number
EU-0035039-0010 1-3
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
35 % (w/w)
7.8. Trade name(s), authorisation number and specific composition of each individual product
Trade name(s)
Antisept WO 50
Market area: EU
Authorisation number
EU-0035039-0011 1-3
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
49,9 % (w/w)
7.9. Trade name(s), authorisation number and specific composition of each individual product
Trade name(s)
PEROXAL 50 AHS
Market area: EU
ALBONE 50
Market area: EU
PEROXAL 50 HSD
Market area: EU
PEROXAL 50 SD
Market area: EU
Authorisation number
EU-0035039-0012 1-3
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
49,9 % (w/w)
1. META SPC 4 ADMINISTRATIVE INFORMATION
1.1. Meta SPC 4 identifier
Identifier
Meta SPC: 4
1.2. Suffix to the authorisation number
Number
1-4
1.3. Product type(s)
Product type(s)
PT02: Disinfectants and algaecides not intended for direct application to humans or animals
PT04: Food and feed area
PT03: Veterinary hygiene
2. META SPC 4 COMPOSITION
2.1. Qualitative and quantitative information on the composition of the meta SPC 4
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
>=30–<=30 % (w/w)
2.2. Type(s) of formulation of the meta SPC 4
Formulation type(s)
SL Soluble concentrate
3. HAZARD AND PRECAUTIONARY STATEMENTS OF THE META SPC 4
Hazard statements
H272: May intensify fire; oxidiser.
H302: Harmful if swallowed.
H318: Causes serious eye damage.
H412: Harmful to aquatic life with long lasting effects.
Precautionary statements
P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P220: Keep away from clothing or other combustible materials.
P261: Avoid breathing vapours.
P264: Wash hands thoroughly after handling.
P270: Do not eat, drink or smoke when using this product.
P273: Avoid release to the environment.
P280: Wear eye protection.
P280: Wear face protection.
P301+P312: IF SWALLOWED: Call a POISON CENTER/doctor if you feel unwell.
P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P310: Immediately call a POISON CENTER/doctor.
P330: Rinse mouth.
4. AUTHORISED USE(S) OF THE META SPC
4.1. Use description
Table 1
Use 4.2: Hard surface disinfection
Product type
PT02: Disinfectants and algaecides not intended for direct application to humans or animals
PT04: Food and feed area
Target organism(s) (including development stage)
Common name: bacteria
Common name: yeasts
Common name: fungi
Field(s) of use
indoor use
outdoor use
Disinfection of non-porous hard surfaces (tables, floors, walls, hard furniture, equipment), by wiping, mopping or using a hand held trigger spray in:
—
Hospitals, health care facilities, industries, institutions … (PT2)
—
Food and feed industry, kitchens, restaurants, abattoirs… (PT4)
Application method(s)
Method: manual application
Detailed description:
Wiping or mopping with a soaked cloth, or spraying with a trigger sprayer.
Application rate(s) and frequency
Number and timing of application:
For bacteria, yeasts and fungi: the product shall be diluted to 1,5 % (expressed as active substance content in % w/w) prior to use. Application rate: 300 ml/m 2 .
The minimum contact time is:
—
5 minutes for bacteria and yeasts
—
15 minutes for fungi.
Frequency: once a day
Apply the product at room temperature.
Category(ies) of users
professional
Pack sizes and packaging material
30 kilogram (kg) and 65 kg high-density polyethylene (HDPE) jerrycans
1 L and 5 L HDPE bottle
4.1.1. Use-specific instructions for use
Thoroughly clean and rinse the surface. Remove excess water from the surface before disinfection, if appropriate.
Manual dilution (jerry can, bottle): Product dilution to the in-use concentration of 1,5 % hydrogen peroxide (w/w) is achieved by an operator in a bucket or small intermediate reservoir.
Wiping and mopping
Soak the wipe or mop with product until completely soaked and then wipe or mop the surface to be disinfected. Make sure to wet the surfaces completely.
Spraying
Fill a hand held sprayer with the diluted solution. Make sure to wet surfaces completely by spraying the product onto the surface to be disinfected.
Allow to take effect for at least the required contact time.
4.1.2. Use-specific risk mitigation measures
This is without prejudice to the application of Council Directive 98/24/EC and other Union legislation in the area of health and safety at work. See section 6 for the full references to this act and the European Standards.
Mixing and loading (manual):
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 10 is mandatory.
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
Wiping and trigger spray application:
—
Ensure that application is carried out in areas with a minimum ventilation of 4 air changes per hour.
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 4 is mandatory.
—
Leave the room directly after application.
Mopping application:
—
Ensure that application is carried out in areas with a minimum ventilation of 4 air changes per hour.
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 10 is mandatory.
—
Leave the room directly after application.
4.1.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See General directions for use.
4.1.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
See General directions for use.
4.1.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
See General directions for use.
4.2. Use description
Table 2
Use 4.3: Disinfection of equipment by filling or immersion
Product type
PT02: Disinfectants and algaecides not intended for direct application to humans or animals
PT04: Food and feed area
Target organism(s) (including development stage)
Common name: bacteria
Common name: yeasts
Common name: fungi
Field(s) of use
indoor use
outdoor use
Disinfection of equipments (e.g. pipes, tanks, fillers, mixers, boxes …) by filling with solution (disinfection of inner surfaces), or immersion in a solution (inner/outer disinfection) in industrial (e.g. cosmetics, chemical synthesis …), institutional, food and feed areas.
Application method(s)
Method: open system: immersion
Detailed description:
Filling or Immersion. Equipment surfaces must be cleaned before disinfection.
Application rate(s) and frequency
Number and timing of application:
The product shall be diluted to 10 % (active substance w/w) prior to use.
The contact time is 5 minutes for bacteria, yeasts, and fungi.
The diluted solution should be at room temperature.
Frequency: once a day
Category(ies) of users
professional
Pack sizes and packaging material
600 litre (L) and 1 000 L HDPE intermediate bulk container (IBC)
220 L HDPE Drum
30 kilogram (kg) and 65 kg high-density polyethylene (HDPE) jerrycans
4.2.1. Use-specific instructions for use
Thoroughly clean and rinse the surface. Remove excess water from the surface before disinfection.
The product is diluted manually or automatic to 10 % hydrogen peroxide by professionals for application.
Automatic dilution (IBC, drum): The product is pumped into an intermediate reservoir where it is mixed with water to the required dose. There is no manual dilution step.
Manual dilution (jerry can): Product dilution to the in-use concentration is achieved by an operator in a bucket or intermediate small reservoir.
The diluted solution is then either used in a bath (disinfection by immersion) or poured into the equipment to be disinfected (disinfection by filling).
Rinse treated [surfaces/equipment/pipes/machinery] with drinking water after application.
Solutions shall be disposed of after a single use
4.2.2. Use-specific risk mitigation measures
This is without prejudice to the application of Council Directive 98/24/EC and other Union legislation in the area of health and safety at work. See section 6 for the full references to this act and the European Standards.
Mixing and loading (automated):
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 4 is mandatory.
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
—
Wear coverall (EN 13034 or equivalent)
Mixing and loading (manual):
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 10 is mandatory.
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
—
Wear coverall (EN 13034 or equivalent)
Disinfection of equipment by filling or immersion:
—
Ensure that application is carried out in areas with a minimum ventilation of 4 air changes per hour.
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 20 is mandatory.
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
—
The bath must be emptied directly after the contact time and removal of equipment.
—
Leave the room directly after application.
4.2.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See General directions for use.
4.2.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
See General directions for use.
4.2.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
See General directions for use.
4.3. Use description
Table 3
Use 4.6: Disinfection of hard surface by spraying for veterinary purpose
Product type
PT03: Veterinary hygiene
Where relevant, an exact description of the authorised use
Target organism(s) (including development stage)
Common name: bacteria
Common name: yeasts
Common name: fungi
Common name: viruses
Field(s) of use
indoor use
outdoor use
Porous and non-porous hard surfaces in animal husbandry (animal houses, pens), including tables, floors, walls, machinery, hard furniture and equipment, excluding outer surfaces of animal transportation.
Application method(s)
Method: open system: spray treatment
Detailed description:
Surfaces must be cleaned before disinfection.
Disinfection of equipment by spraying (medium pressure); A portable spraying equipment (volume ~ 20 Litres, medium pressure, hand held) is filled with the product dilution and then used for disinfection. Manual dilution (jerry can): Product dilution to the in-use concentration is achieved by an operator in a bucket or spray reservoir. Surfaces must kept wet during disinfection.
Application rate(s) and frequency
Number and timing of application:
Prior to use, the product shall be diluted to (all concentrations are expressed as active substance content % w/w):
—
2 % for porous surfaces in animal husbandry
—
1,5 % for non-porous surfaces in animal husbandry
Application rate: 300 ml/m 2 .
The minimum contact time is:
—
30 minutes for porous and non-porous surfaces in animal husbandry
Frequency: once a week for porous and non-porous surfaces in animal husbandry.
Category(ies) of users
professional
Pack sizes and packaging material
30 kilogram (kg) and 65 kg high-density polyethylene (HDPE) jerrycans
4.3.1. Use-specific instructions for use
Clean surfaces before use.
Dose the concentrate in the reservoir of the pressure cleaner to obtain an in-use concentration of:
—
2 % for porous surfaces in animal husbandry
—
1,5 % for non-porous surfaces in animal husbandry
Use a pressure washer or other mechanical sprayer to apply the diluted solution at an application rate of 300 ml spray /m 2 . The disinfection solution shall remain in contact with the surface to be disinfected for at least:
30 minutes for porous and non-porous surfaces in animal husbandry
4.3.2. Use-specific risk mitigation measures
This is without prejudice to the application of Council Directive 98/24/EC and other Union legislation in the area of health and safety at work. See section 6 for the full references to this act and the European Standards.
Mixing and loading (automated):
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 4 is mandatory.
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
—
Wear coverall (EN 13034 or equivalent)
Mixing and loading (manual):
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 10 is mandatory.
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
—
Wear coverall (EN 13034 or equivalent)
Spraying, hard surfaces:
—
Ensure that application is carried out in areas with a minimum ventilation of 4 air changes per hour.
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 20 is mandatory.
—
Animals are not allowed to be present during treatment
—
Do not allow re-entry of animals to the disinfected facilities before 15 minutes after disinfection.
—
Leave the room directly after application.
4.3.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See General directions for use.
4.3.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
See General directions for use.
4.3.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
See General directions for use.
4.4. Use description
Table 4
Use 4.10: Disinfection of hard surfaces by medium pressure spraying
Product type
PT02: Disinfectants and algaecides not intended for direct application to humans or animals
PT04: Food and feed area
Target organism(s) (including development stage)
Common name: bacteria
Common name: yeasts
Common name: fungi
Field(s) of use
indoor use
outdoor use
Non-porous hard surfaces (e.g. floors, walls, work surfaces including food contact surfaces) in industry, institutions and health care facilities.
Application method(s)
Method: open system: spray treatment
Detailed description:
Surfaces must be cleaned before disinfection.
Disinfection of equipment by spraying (medium pressure);
A portable spraying equipment (volume ~ 20 Liters, medium pressure, hand held) is filled with the product dilution and then used for disinfection.
Application rate(s) and frequency
Number and timing of application:
For bacteria and yeasts and fungi, the product shall be diluted to 1,5 % (active substance % w/w) prior to use.
The minimum contact time is:
—
5 minutes for bacteria and yeasts
—
15 minutes for fungi.
Application rate: 300 ml/m 2
Apply the product at room temperature
Frequency: once a day
Category(ies) of users
professional
Pack sizes and packaging material
220 L HDPE Drum
600 litre (L) and 1 000 L HDPE intermediate bulk container (IBC)
30 kilogram (kg) and 65 kg high-density polyethylene (HDPE) jerrycans
4.4.1. Use-specific instructions for use
Thoroughly clean and rinse the surface. Remove excess water from the surface before disinfection.
Dose the concentrate in the reservoir of the pressure cleaner to obtain a suitable in-use concentration of the active substance (see application rate section).
Automatic dilution (IBC, drum): The product is pumped into the reservoir of the pressure cleaner where it is mixed with water to the required dose. There is no manual dilution step.
Manual dilution (jerry can): Product dilution to the in-use concentration is achieved by an operator in a bucket or spray reservoir.
Surfaces must kept wet during disinfection.
Use a pressure washer or other mechanical sprayer to apply the diluted solution at an application rate of 300 ml/m 2 . The disinfection solution shall remain in contact with the surface to be disinfected 5 minutes for removal of bacteria and yeasts, and 15 minutes to remove fungi.
Premises shall be well-ventilated before re-entry
4.4.2. Use-specific risk mitigation measures
This is without prejudice to the application of Council Directive 98/24/EC and other Union legislation in the area of health and safety at work. See section 6 for the full references to this act and the European Standards.
Mixing and loading (automated):
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 4 is mandatory.
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
Mixing and loading (manual):
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 10 is mandatory.
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
Spraying of hard surfaces:
—
Ensure that application is carried out in areas with a minimum ventilation of 4 air changes per hour.
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 20 is mandatory.
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
4.4.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See General directions for use.
4.4.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
See General directions for use.
4.4.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
See General directions for use.
5. GENERAL DIRECTIONS FOR USE OF THE META SPC 4
5.1. Instructions for use
Unless otherwise stated on the label, products must be diluted for use.
Follow the label instructions for use dilutions and application volumes according to the use required.
Surfaces shall be cleaned before disinfection.
See Use-specific instructions for use per use
5.2. Risk mitigation measures
—
No access of third parties during application/treatment/maintenance, unless the required personal protective equipment as prescribed for the professional user is worn.
—
Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m 3 ) or relevant lower national reference value
5.3. Particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
First-Aid measures
IF INHALED: If symptoms occur call a POISON CENTRE or a doctor.
IF SWALLOWED: Immediately rinse mouth. Give something to drink, if exposed person is able to swallow. Do NOT induce vomiting. Call 112/ambulance for medical assistance. Information to Healthcare personnel/doctor: Initiate life support measures if needed, thereafter call a POISON CENTRE.
IF ON SKIN: Immediately wash skin with plenty of water. Thereafter take off all contaminated clothing and wash it before reuse. Continue to wash the skin with water for 15 minutes. Call a POISON CENTRE or a doctor.
IF IN EYES: Immediately rinse with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing for at least 15 minutes. Call 112/ambulance for medical assistance. Information to Healthcare personnel/doctor: The eyes should also be rinsed repeatedly on the way to the doctor if eye exposure to alkaline chemicals (pH > 11), amines and acids like acetic acid, formic acid or propionic acid.
Protection of first-aiders: In case of insufficient ventilation, wear suitable respiratory equipment. Protective suit
Fire-fighting measures
Extinguishing media:
Suitable extinguishing media: In case of fire involving the product: Water spray. Unsuitable extinguishing media: All other extinguishants
Special hazards arising from the substance or mixture: Contact with combustible material may cause fire. Thermal decomposition gives: Oxygen, that can enhance sites of combustion. Hazards of over-pressurization in containers exposed to heat: explosion risk.
Precautions for fire-fighters: Specific methods: Keep upwind and operate from safe distance. In case of fire, remove exposed containers. Containers/tanks should be cooled with water spray.
Special protective actions for fire-fighters: Wear self-contained breathing apparatus and protective suit.
Accidental release measures
Personal precautions, protective equipment and emergency procedures:
Evacuate non-essential staff and those not equipped with individual protection apparatus. Prohibit contact with eyes. Avoid contact with skin. Avoid inhalation of vapours. Prohibit all sources of sparks and ignition - Do not smoke. If safe to do so, plug or seal off leak. Remove all incompatible substances.
Environmental precautions: Dam up with sand or inert earth (do not use combustible materials). Dilute with large quantities of water before discharging into sewers or into the environment
Methods and materials for containment and cleaning up:
Recovery: Soak up with inert absorbent material. Never reintroduce the spilled product in another container. Risk of decomposition.
Neutralisation: Dilute with water.
Elimination: Dispose of rinse water as waste water.
5.4. Instructions for safe disposal of the product and its packaging
Waste treatment
Disposal of product: Dilute with water.
Disposal of packaging: Clean container with water. Recycle or incinerate at an approved waste disposal site. In accordance with local and national regulations.
5.5. Conditions of storage and shelf-life of the product under normal conditions of storage
Shelf-life of 1 year.
The product should be stored in the original packaging.
Protect from light.
Store below 54 °C.
6. OTHER INFORMATION
Council Directive 98/24/EC of 7 April 1998 on the protection of the health and safety of workers from the risks related to chemical agents at work (fourteenth individual Directive within the meaning of Article 16(1) of Directive 89/391/EEC) ( OJ L 131, 5.5.1998, p. 11 ).
Professionals (including industrial, professionals) mean trained professional if this is required by national legislation.
Please be aware of the European reference value of 1,25 mg/m 3 for the active substance hydrogen peroxide (CAS No.: 7722-84-1) which was used for the risk assessment for the biocidal product (please be aware that relevant lower national limit values may apply).
The full titles of the EN standards referenced in the Risk mitigation measures are:
—
EN 13832 – Footwear protecting against chemicals
—
EN 374 – Protective gloves against dangerous chemicals and micro-organisms
—
EN 405 – Respiratory protective devices
—
EN 166 – Eye protection against chemicals
—
EN 13034 – Protective coverall against liquid chemicals – type 6
7. THIRD INFORMATION LEVEL: INDIVIDUAL PRODUCTS IN THE META SPC 4
7.1. Trade name(s), authorisation number and specific composition of each individual product
Trade name(s)
Antisept WO 30
Market area: EU
Authorisation number
EU-0035039-0013 1-4
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
30 % (w/w)
7.2. Trade name(s), authorisation number and specific composition of each individual product
Trade name(s)
PEROXAL 30 AHS
Market area: EU
ALBONE 30
Market area: EU
PEROXAL 30 HSD
Market area: EU
PEROXAL 30 SD
Market area: EU
PEROXAL 30 ED
Market area: EU
Authorisation number
EU-0035039-0014 1-4
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
30 % (w/w)
7.3. Trade name(s), authorisation number and specific composition of each individual product
Trade name(s)
ELIGERM PSA
Market area: EU
ELIGERM PEROX
Market area: EU
Authorisation number
EU-0035039-0015 1-4
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
30 % (w/w)
1. META SPC 5 ADMINISTRATIVE INFORMATION
1.1. Meta SPC 5 identifier
Identifier
Meta SPC: 6
1.2. Suffix to the authorisation number
Number
1-5
1.3. Product type(s)
Product type(s)
PT02: Disinfectants and algaecides not intended for direct application to humans or animals
PT04: Food and feed area
2. META SPC 5 COMPOSITION
2.1. Qualitative and quantitative information on the composition of the meta SPC 5
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
>=25 –<=25 % (w/w)
2.2. Type(s) of formulation of the meta SPC 5
Formulation type(s)
AL Any other liquid
3. HAZARD AND PRECAUTIONARY STATEMENTS OF THE META SPC 5
Hazard statements
H272: May intensify fire; oxidiser.
H302: Harmful if swallowed.
H318: Causes serious eye damage.
H412: Harmful to aquatic life with long lasting effects.
Precautionary statements
P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P220: Keep away from clothing or other combustible materials.
P261: Avoid breathing vapours.
P264: Wash hands thoroughly after handling.
P270: Do not eat, drink or smoke when using this product.
P273: Avoid release to the environment.
P280: Wear eye protection.
P280: Wear face protection.
P301+P312: IF SWALLOWED: Call a POISON CENTER/doctor if you feel unwell.
P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P310: Immediately call a POISON CENTER/doctor.
P330: Rinse mouth.
4. AUTHORISED USE(S) OF THE META SPC
4.1. Use description
Table 1
Use 6.1: Room disinfection with Nebulized Hydrogen Peroxide
Product type
PT02: Disinfectants and algaecides not intended for direct application to humans or animals
PT04: Food and feed area
Where relevant, an exact description of the authorised use
Target organism(s) (including development stage)
Common name: bacteria
Common name: yeasts
Common name: fungi
Field(s) of use
indoor use
Disinfection of dry surfaces in closed rooms and enclosed spaces by Nebulized hydrogen peroxide, e.g. laboratory equipment, hospital rooms, emergency vehicles, food and feed areas.
Application method(s)
Method: - Nebulization
Detailed description:
Nebulization to disinfect hard non-porous surfaces.
Application rate(s) and frequency
Number and timing of application:
The product is a 25 % w/w hydrogen peroxide solution and is ready-to-use.
Room volume: 30–150 m 3
Diffusion rate:
Bacteria and yeast: 10 ml/m 3 product
Fungi: 11,4 ml/m 3 product
Diffusion time: Dependant upon the room volume.
Temperature: room temperature
Recommended relative humidity: 40 to 80 %
Contact time: 3 hours
Frequency: maximum 3 times per 24 hour period.
Category(ies) of users
professional
Pack sizes and packaging material
Sealed 1L HDPE cartridges.
4.1.1. Use-specific instructions for use
Thoroughly clean and rinse the surface. Remove excess water from the surface before disinfection, if appropriate install biological and chemical indicators to validate the disinfection cycle.
The nebulizer devices are fed by connecting a drum of hydrogen peroxide solution (automated transfer and dosing) or by inserting a sealed cartridge. Professionals seal the enclosed space or room and initiate the decontamination cycle.
During this step, exposure to hydrogen peroxide is not possible as access to the fog-treated area is denied. The decontamination process starts with a dehumidification phase in which the machine removes water from the atmosphere.
In the disinfection phase, the machine injects nebulized hydrogen peroxide, depending on the device, into the sealed area for decontamination to get the hydrogen peroxide concentration up to the effective levels.
The succeeding disinfection phase lasts 3 hours during which the hydrogen peroxide fog disinfects the surfaces inside the sealed space.
After finishing the decontamination phase, the aeration cycle starts. This step has variable durations since it is complete when sensors inform that the hydrogen peroxide level is below 1,25 mg/m 3 . Biological and chemical indicators can then be collected to confirm the efficacy of the decontamination cycle
The user shall always carry out a microbiological validation of the disinfection in the rooms to be disinfected (or in a suitable “standard room”, if applicable) with the devices to be used after which a protocol for disinfection of these rooms can be made and used thereafter.
Access to the treated area is denied during the disinfection process.
4.1.2. Use-specific risk mitigation measures
This is without prejudice to the application of Council Directive 98/24/EC and other Union legislation in the area of health and safety at work. See section 6 for the full references to this act and the European Standards.
All surfaces must be cleaned before disinfection
—
Insert the sealed cartridge as delivered by the manufacturer into the machine. See equipment user’s manual for proper equipment preparation and set-up
—
The applicator must placard or post all entrances to the treatment enclosure with signs bearing:
—
The signal word ‘DANGER’ in red. ‘Area under treatment, DO NOT ENTER/NO ENTRY.’
—
The statement ‘This sign may only be removed 1 hour after the treatment enclosure has been aerated to hydrogen peroxide levels less than or equal to 1,25 mg/m 3
’.
—
Identification of hydrogen peroxide as a hazard associated with the treatment process.
—
Contact information for the applicator.
The following PPE are required if emergency re-entry is required before the air concentration has dropped below the AEC:
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
—
Wear a protective coverall (at least type 6, EN 13034 or equivalent) (coverall material to be specified by the authorisation holder within the product information).
—
Wear chemical resistant boots (EN 13832 or equivalent)
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 40 is mandatory.
—
During exposure time, the treated room may only be entered wearing suitable personal protective equipment
For other instructions see General directions of use.
4.1.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See General directions for use.
4.1.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
See General directions for use.
4.1.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
See General directions for use.
4.2. Use description
Table 2
Use 6.4b: Disinfection of food packaging by aseptic technology (spray/vapour)
Product type
PT04: Food and feed area
Target organism(s) (including development stage)
Common name: bacteria
Common name: Bacterial spores
Common name: yeasts
Field(s) of use
indoor use
Disinfection of cardboard or plastic packaging (e.g. bricks, bottles, cups, pouches …) before filling with sensitive food products to be stored at room temperature for a long period
Application method(s)
Method: closed system
Detailed description:
Surfaces must be cleaned before disinfection. ‘spray technology’: the packaging material (preformed cardboard containers, plastic bottles and plastic preforms) is exposed to hydrogen peroxide vapor generated from a 25 % hydrogen peroxide solution which is sprayed and then vaporized, ensuring the complete sterilization of the inner surface of the packaging. Further hot sterile air removes hydrogen peroxide residual in the brick or bottle. The sterile packaging is then filled with sterile food products and sealed. The disinfection machines are closed systems with no access to professionals during operation. In case of maintenance, the machine is stopped, hydrogen peroxide is removed (vapour extraction).
Application rate(s) and frequency
Number and timing of application:
Validated food processing systems that have control over the contaminant load on food packaging surfaces or food processing equipment prior to fill may vary concentration, temperature, and/or contact time to achieve the required level of disinfection. Container volume range (generally from 100 to 2 000 ml) may also influence operating parameters.
The biocidal product is 25 % w/w hydrogen peroxide solutions and is ready-to-use.
Spray technology:
Application rate: 20–30 g H 2 O 2 /m 3
Contact time: 12 seconds
Temperature: 130 °C
Category(ies) of users
professional
Pack sizes and packaging material
600 litre (L) and 1 000 L HDPE intermediate bulk container (IBC)
30 kilogram (kg) and 65 kg high-density polyethylene (HDPE) jerrycans
4.2.1. Use-specific instructions for use
All surfaces must be cleaned before disinfection.
The user shall always carry out a microbiological validation of the disinfection process in the machine to be used with the devices to be used after which a protocol for disinfection of these machine can be made and used thereafter.
4.2.2. Use-specific risk mitigation measures
This is without prejudice to the application of Council Directive 98/24/EC and other Union legislation in the area of health and safety at work. See section 6 for the full references to this act and the European Standards.
Mixing and loading (automated) or maintenance of the machine:
1.
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 4 is mandatory.
2.
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, polyvinyl chloride (PVC).
3.
The use of eye protection (chemical goggles/face shield) (EN 166 or equivalent) during handling of the product is mandatory.
4.
Wear coverall (EN 13034 or equivalent)
Mixing and loading (manual):
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 10 is mandatory.
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC.
—
The use of eye protection (chemical goggles/face shield) (EN 166 or equivalent) during handling of the product is mandatory.
During use of the machine the following risk mitigation measures (RMMs) apply:
—
All surfaces must be cleaned before disinfection.
—
Machines to be operated in areas where local exhaust ventilation (LEV) or forced ventilation is operational.
—
Wear coverall (EN 13034 or equivalent)
For other instructions, see General directions for use.
4.2.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See General directions for use.
4.2.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
See General directions for use.
4.2.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
See General directions for use.
5. GENERAL DIRECTIONS FOR USE OF THE META SPC 5
5.1. Instructions for use
Unless otherwise stated on the label, products must be diluted for use.
Follow the label instructions for use dilutions and application volumes according to the use required.
Surfaces shall be cleaned before disinfection.
See Use-specific instructions for use per use
5.2. Risk mitigation measures
—
No access of third parties during application/treatment/maintenance, unless the required personal protective equipment as prescribed for the professional user is worn.
—
Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m 3 ) or relevant lower national reference value
5.3. Particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
First-Aid measures
IF INHALED: If symptoms occur call a POISON CENTRE or a doctor.
IF SWALLOWED: Immediately rinse mouth. Give something to drink, if exposed person is able to swallow. Do NOT induce vomiting. Call 112/ambulance for medical assistance. Information to Healthcare personnel/doctor: Initiate life support measures if needed, thereafter call a POISON CENTRE.
IF ON SKIN: Immediately wash skin with plenty of water. Thereafter take off all contaminated clothing and wash it before reuse. Continue to wash the skin with water for 15 minutes. Call a POISON CENTRE or a doctor.
IF IN EYES: Immediately rinse with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing for at least 15 minutes. Call 112/ambulance for medical assistance. Information to Healthcare personnel/doctor: The eyes should also be rinsed repeatedly on the way to the doctor if eye exposure to alkaline chemicals (pH > 11), amines and acids like acetic acid, formic acid or propionic acid.
Protection of first-aiders: In case of insufficient ventilation, wear suitable respiratory equipment. Protective suit
Fire-fighting measures
Extinguishing media:
Suitable extinguishing media: In case of fire involving the product: Water spray. Unsuitable extinguishing media: All other extinguishants
Special hazards arising from the substance or mixture: Contact with combustible material may cause fire. Thermal decomposition gives: Oxygen, that can enhance sites of combustion. Hazards of over-pressurization in containers exposed to heat: explosion risk.
Precautions for fire-fighters: Specific methods: Keep upwind and operate from safe distance. In case of fire, remove exposed containers. Containers/tanks should be cooled with water spray.
Special protective actions for fire-fighters: Wear self-contained breathing apparatus and protective suit.
Accidental release measures
Personal precautions, protective equipment and emergency procedures:
Evacuate non-essential staff and those not equipped with individual protection apparatus. Prohibit contact with eyes. Avoid contact with skin. Avoid inhalation of vapours. Prohibit all sources of sparks and ignition - Do not smoke. If safe to do so, plug or seal off leak. Remove all incompatible substances.
Environmental precautions: Dam up with sand or inert earth (do not use combustible materials). Dilute with large quantities of water before discharging into sewers or into the environment
Methods and materials for containment and cleaning up:
Recovery: Soak up with inert absorbent material. Never reintroduce the spilled product in another container. Risk of decomposition.
Neutralisation: Dilute with water.
Elimination: Dispose of rinse water as waste water.
5.4. Instructions for safe disposal of the product and its packaging
Waste treatment
Disposal of product: Dilute with water.
Disposal of packaging: Clean container with water. Recycle or incinerate at an approved waste disposal site. In accordance with local and national regulations.
5.5. Conditions of storage and shelf-life of the product under normal conditions of storage
Shelf-life of 1 year.
The product should be stored in the original packaging.
Protect from light.
Store below 54 °C.
6. OTHER INFORMATION
Council Directive 98/24/EC of 7 April 1998 on the protection of the health and safety of workers from the risks related to chemical agents at work (fourteenth individual Directive within the meaning of Article 16(1) of Directive 89/391/EEC) ( OJ L 131, 5.5.1998, p. 11 ).
Professionals (including industrial, professionals) mean trained professional if this is required by national legislation.
Please be aware of the European reference value of 1,25 mg/m 3 for the active substance hydrogen peroxide (CAS No.: 7722-84-1) which was used for the risk assessment for the biocidal product (please be aware that relevant lower national limit values may apply).
The full titles of the EN standards referenced in the Risk mitigation measures are:
—
EN 13832 – Footwear protecting against chemicals
—
EN 374 – Protective gloves against dangerous chemicals and micro-organisms
—
EN 405 – Respiratory protective devices
—
EN 166 – Eye protection against chemicals
—
EN 13034 – Protective coverall against liquid chemicals – type 6
7. THIRD INFORMATION LEVEL: INDIVIDUAL PRODUCTS IN THE META SPC 5
7.1. Trade name(s), authorisation number and specific composition of each individual product
Trade name(s)
VALSTERANE 25 SHP
Market area: EU
Authorisation number
EU-0035039-0016 1-5
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
25 % (w/w)
1. META SPC 6 ADMINISTRATIVE INFORMATION
1.1. Meta SPC 6 identifier
Identifier
Meta SPC: 7
1.2. Suffix to the authorisation number
Number
1-6
1.3. Product type(s)
Product type(s)
PT02: Disinfectants and algaecides not intended for direct application to humans or animals
PT04: Food and feed area
2. META SPC 6 COMPOSITION
2.1. Qualitative and quantitative information on the composition of the meta SPC 6
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
>=25–<=25 % (w/w)
2.2. Type(s) of formulation of the meta SPC 6
Formulation type(s)
AL Any other liquid
3. HAZARD AND PRECAUTIONARY STATEMENTS OF THE META SPC 6
Hazard statements
H272: May intensify fire; oxidiser.
H302: Harmful if swallowed.
H318: Causes serious eye damage.
H412: Harmful to aquatic life with long lasting effects.
Precautionary statements
P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P220: Keep away from clothing or other combustible materials.
P261: Avoid breathing vapours.
P264: Wash hands thoroughly after handling.
P270: Do not eat, drink or smoke when using this product.
P273: Avoid release to the environment.
P280: Wear eye protection.
P280: Wear face protection.
P301+P312: IF SWALLOWED: Call a POISON CENTER/doctor if you feel unwell.
P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P310: Immediately call a POISON CENTER/doctor.
P330: Rinse mouth.
4. AUTHORISED USE(S) OF THE META SPC
4.1. Use description
Table 1
Use 7.1: Room disinfection with Nebulized Hydrogen Peroxide
Product type
PT02: Disinfectants and algaecides not intended for direct application to humans or animals
PT04: Food and feed area
Where relevant, an exact description of the authorised use
Target organism(s) (including development stage)
Common name: bacteria
Common name: yeasts
Common name: fungi
Field(s) of use
indoor use
Disinfection of dry surfaces in closed rooms and enclosed spaces by Nebulized hydrogen peroxide, e.g. laboratory equipment, hospital rooms, emergency vehicles, food and feed areas.
Application method(s)
Method: - Nebulization
Detailed description:
Nebulization to disinfect hard non-porous surfaces.
Application rate(s) and frequency
Number and timing of application:
The product is a 25 % w/w hydrogen peroxide solution and is ready-to-use.
Room volume: 30–150 m 3
Diffusion rate:
Bacteria and yeast: 10 ml/m 3 product
Fungi: 11,4 ml/m 3 product
Diffusion time: Dependant upon the room volume.
Temperature: room temperature
Recommended relative humidity: 40 to 80 %
Contact time: 3 hours
Frequency: maximum 3 times per 24 hour period.
Category(ies) of users
professional
Pack sizes and packaging material
Sealed 1L HDPE cartridges.
4.1.1. Use-specific instructions for use
Thoroughly clean and rinse the surface. Remove excess water from the surface before disinfection, if appropriate install biological and chemical indicators to validate the disinfection cycle.
The nebulizer devices are fed by connecting a drum of hydrogen peroxide solution (automated transfer and dosing) or by inserting a sealed cartridge. Professionals seal the enclosed space or room and initiate the decontamination cycle.
During this step, exposure to hydrogen peroxide is not possible as access to the fog-treated area is denied. The decontamination process starts with a dehumidification phase in which the machine removes water from the atmosphere.
In the disinfection phase, the machine injects nebulized hydrogen peroxide, depending on the device, into the sealed area for decontamination to get the hydrogen peroxide concentration up to the effective levels.
The succeeding disinfection phase lasts 3 hours during which the hydrogen peroxide fog disinfects the surfaces inside the sealed space.
After finishing the decontamination phase, the aeration cycle starts. This step has variable durations since it is complete when sensors inform that the hydrogen peroxide level is below 1,25 mg/m 3 . Biological and chemical indicators can then be collected to confirm the efficacy of the decontamination cycle
The user shall always carry out a microbiological validation of the disinfection in the rooms to be disinfected (or in a suitable “standard room”, if applicable) with the devices to be used after which a protocol for disinfection of these rooms can be made and used thereafter.
Access to the treated area is denied during the disinfection process.
4.1.2. Use-specific risk mitigation measures
This is without prejudice to the application of Council Directive 98/24/EC and other Union legislation in the area of health and safety at work. See section 6 for the full references to this act and the European Standards.
All surfaces must be cleaned before disinfection
—
Insert the sealed cartridge as delivered by the manufacturer into the machine. See equipment user’s manual for proper equipment preparation and set-up
—
The applicator must placard or post all entrances to the treatment enclosure with signs bearing:
—
The signal word ‘DANGER’ in red. ‘Area under treatment, DO NOT ENTER/NO ENTRY.’
—
The statement ‘This sign may only be removed 1 hour after the treatment enclosure has been aerated to hydrogen peroxide levels less than or equal to 1,25 mg/m 3
’.
—
Identification of hydrogen peroxide as a hazard associated with the treatment process.
—
Contact information for the applicator.
The following PPE are required if emergency re-entry is required before the air concentration has dropped below the AEC:
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
—
Wear a protective coverall (at least type 6, EN 13034 or equivalent) (coverall material to be specified by the authorisation holder within the product information).
—
Wear chemical resistant boots (EN 13832 or equivalent)
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 40 is mandatory.
—
During exposure time, the treated room may only be entered wearing suitable personal protective equipment
For other instructions see General directions of use.
4.1.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See General directions for use.
4.1.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
See General directions for use.
4.1.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
See General directions for use.
5. GENERAL DIRECTIONS FOR USE OF THE META SPC 6
5.1. Instructions for use
Unless otherwise stated on the label, products must be diluted for use.
Follow the label instructions for use dilutions and application volumes according to the use required.
Surfaces shall be cleaned before disinfection.
See Use-specific instructions for use per use
5.2. Risk mitigation measures
—
No access of third parties during application/treatment/maintenance, unless the required personal protective equipment as prescribed for the professional user is worn.
—
Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m 3 ) or relevant lower national reference value
5.3. Particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
First-Aid measures
IF INHALED: If symptoms occur call a POISON CENTRE or a doctor.
IF SWALLOWED: Immediately rinse mouth. Give something to drink, if exposed person is able to swallow. Do NOT induce vomiting. Call 112/ambulance for medical assistance. Information to Healthcare personnel/doctor: Initiate life support measures if needed, thereafter call a POISON CENTRE.
IF ON SKIN: Immediately wash skin with plenty of water. Thereafter take off all contaminated clothing and wash it before reuse. Continue to wash the skin with water for 15 minutes. Call a POISON CENTRE or a doctor.
IF IN EYES: Immediately rinse with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing for at least 15 minutes. Call 112/ambulance for medical assistance. Information to Healthcare personnel/doctor: The eyes should also be rinsed repeatedly on the way to the doctor if eye exposure to alkaline chemicals (pH > 11), amines and acids like acetic acid, formic acid or propionic acid.
Protection of first-aiders: In case of insufficient ventilation, wear suitable respiratory equipment. Protective suit
Fire-fighting measures
Extinguishing media:
Suitable extinguishing media: In case of fire involving the product: Water spray Unsuitable extinguishing media: All other extinguishants
Special hazards arising from the substance or mixture: Contact with combustible material may cause fire. Thermal decomposition gives: Oxygen, that can enhance sites of combustion. Hazards of over-pressurization in containers exposed to heat: explosion risk.
Precautions for fire-fighters: Specific methods: Keep upwind and operate from safe distance. In case of fire, remove exposed containers. Containers/tanks should be cooled with water spray.
Special protective actions for fire-fighters: Wear self-contained breathing apparatus and protective suit.
Accidental release measures
Personal precautions, protective equipment and emergency procedures:
Evacuate non-essential staff and those not equipped with individual protection apparatus. Prohibit contact with eyes. Avoid contact with skin. Avoid inhalation of vapours. Prohibit all sources of sparks and ignition - Do not smoke. If safe to do so, plug or seal off leak. Remove all incompatible substances.
Environmental precautions: Dam up with sand or inert earth (do not use combustible materials). Dilute with large quantities of water before discharging into sewers or into the environment
Methods and materials for containment and cleaning up:
Recovery: Soak up with inert absorbent material. Never reintroduce the spilled product in another container. Risk of decomposition.
Neutralisation: Dilute with water.
Elimination: Dispose of rinse water as waste water.
5.4. Instructions for safe disposal of the product and its packaging
Waste treatment
Disposal of product: Dilute with water.
Disposal of packaging: Clean container with water. Recycle or incinerate at an approved waste disposal site. In accordance with local and national regulations.
5.5. Conditions of storage and shelf-life of the product under normal conditions of storage
Shelf-life of 1 year.
The product should be stored in the original packaging.
Protect from light.
Store below 54 °C.
6. OTHER INFORMATION
Council Directive 98/24/EC of 7 April 1998 on the protection of the health and safety of workers from the risks related to chemical agents at work (fourteenth individual Directive within the meaning of Article 16(1) of Directive 89/391/EEC) ( OJ L 131, 5.5.1998, p. 11 ).
Professionals (including industrial, professionals) mean trained professional if this is required by national legislation.
Please be aware of the European reference value of 1,25 mg/m 3 for the active substance hydrogen peroxide (CAS No.: 7722-84-1) which was used for the risk assessment for the biocidal product (please be aware that relevant lower national limit values may apply).
The full titles of the EN standards referenced in the Risk mitigation measures are:
—
EN 13832 – Footwear protecting against chemicals
—
EN 374 – Protective gloves against dangerous chemicals and micro-organisms
—
EN 405 – Respiratory protective devices
—
EN 166 – Eye protection against chemicals
—
EN 13034 – Protective coverall against liquid chemicals – type 6
7. THIRD INFORMATION LEVEL: INDIVIDUAL PRODUCTS IN THE META SPC 6
7.1. Trade name(s), authorisation number and specific composition of each individual product
Trade name(s)
PEROXAL 25 TNB
Market area: EU
Authorisation number
EU-0035039-0017 1-6
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
25 % (w/w)
1. META SPC 7 ADMINISTRATIVE INFORMATION
1.1. Meta SPC 7 identifier
Identifier
Meta SPC: 8
1.2. Suffix to the authorisation number
Number
1-7
1.3. Product type(s)
Product type(s)
PT02: Disinfectants and algaecides not intended for direct application to humans or animals
2. META SPC 7 COMPOSITION
2.1. Qualitative and quantitative information on the composition of the meta SPC 7
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
>=35–<=35 % (w/w)
2.2. Type(s) of formulation of the meta SPC 7
Formulation type(s)
AL Any other liquid
3. HAZARD AND PRECAUTIONARY STATEMENTS OF THE META SPC 7
Hazard statements
H272: May intensify fire; oxidiser.
H302: Harmful if swallowed.
H315: Causes skin irritation.
H318: Causes serious eye damage.
H335: May cause respiratory irritation.
H412: Harmful to aquatic life with long lasting effects.
Precautionary statements
P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P220: Keep away from clothing or other combustible materials.
P261: Avoid breathing vapours.
P264: Wash hands thoroughly after handling.
P270: Do not eat, drink or smoke when using this product.
P271: Use only outdoors or in a well-ventilated area.
P273: Avoid release to the environment.
P280: Wear eye protection.
P280: Wear face protection.
P301+P312: IF SWALLOWED: Call a POISON CENTER/doctor if you feel unwell.
P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
P304+P340: IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P310: Immediately call a POISON CENTER/doctor.
P330: Rinse mouth.
P332+P313: If skin irritation occurs: Get medical advice.
P332+P313: If skin irritation occurs: Get medical attention.
P403+P233: Store in a well-ventilated place. Keep container tightly closed.
P405: Store locked up.
4. AUTHORISED USE(S) OF THE META SPC
4.1. Use description
Table 1
Use 8.9: Disinfection of internal surfaces of pharmaceutical/medical isolators
Product type
PT02: Disinfectants and algaecides not intended for direct application to humans or animals
Target organism(s) (including development stage)
Common name: Bacterial spores
Common name: fungi
Common name: bacteria
Common name: yeasts
Field(s) of use
indoor use
Professional disinfection of inner surfaces of isolators (leak-proof enclosures where operators manipulate sterile products without direct contact) by vaporized hydrogen peroxide.
Application method(s)
Method: closed system
Detailed description:
Vaporisation of hydrogen peroxide
Application rate(s) and frequency
Number and timing of application:
The product is a 35 % w/w hydrogen peroxide solution and is ready-to-use.
Volume: 0,04–0,61 m 3
Application rate (recommended): 230–390 g product /m 3
Contact time: 8 to 60 minutes
Temperature: 20 °C
Recommended humidity: up to 50 %
Aeration time: suitable to reach a 1 ppm residual H 2 O 2 content in the enclosure
Frequency: maximum 3 times per day
Category(ies) of users
professional
Pack sizes and packaging material
1L and 5L HDPE bottle
4.1.1. Use-specific instructions for use
Thoroughly clean and rinse the surface. Remove excess water from the surface before disinfection, if appropriate. Install biological and chemical indicators to validate the disinfection cycle.
The vaporiser unit is fed by connecting a 1l bottle of hydrogen peroxide solution.
The decontamination process starts with a dehumidification phase in which the machine removes water from the atmosphere.
In the disinfection phase, the machine injects vaporised hydrogen peroxide into the sealed area for decontamination to get the hydrogen peroxide concentration up to the effective level. During this phase, hydrogen peroxide vapour disinfects the surfaces inside the sealed space.
After finishing the decontamination phase, the aeration cycle starts. This step has variable durations since it is complete when sensors inform that the hydrogen peroxide level is below a defined value.
Biological and chemical indicators can then be collected to confirm the efficacy of the decontamination cycle. No one will actually enter the isolator after disinfection. No re-entry requirement is therefore necessary.
Application rates may vary from one equipment to the other. It is possible to use the product with different decontamination devices or for isolators with different volumes. The user shall always carry out a microbiological validation of the disinfection in the isolator to be disinfected with the devices to be used after which a protocol for disinfection of these isolators can be made and used thereafter.
4.1.2. Use-specific risk mitigation measures
This is without prejudice to the application of Council Directive 98/24/EC and other Union legislation in the area of health and safety at work. See section 6 for the full references to this act and the European Standards.
Insert the sealed cartridge as delivered by the manufacturer into the VHP machine. See equipment user’s manual for proper equipment preparation and set-up.
The applicator must placard or post all entrances to the treatment enclosure with signs bearing:
—
The signal word ‘DANGER’ in red. ‘Area under treatment, DO NOT ENTER/NO ENTRY.’
—
The statement ‘This sign may only be removed 1 hour after the treatment enclosure has been aerated to hydrogen peroxide levels less than or equal to 1,25 mg/m 3'
’.
—
Identification of hydrogen peroxide as a hazard associated with the treatment process.
—
Contact information for the applicator.
The following PPE are required if emergency re-entry is required before the air concentration has dropped below the AEC:
—
Wear protective chemical resistant gloves (EN 374 or equivalent) during product handling phase. Examples of preferred materials for insulating gloves: neoprene, PVC.
—
The use of eye protection (chemical goggles/face shield) (EN166 or equivalent) during handling of the product is mandatory.
—
Wear a protective coverall (at least type 6, EN 13034 or equivalent) (coverall material to be specified by the authorisation holder within the product information).
—
Wear chemical resistant boots (EN 13832 or equivalent).
—
Use of respiratory protective equipment (RPE) (EN 405 or equivalent) with APF 40 is mandatory.
—
During exposure time, the treated room may only be entered wearing suitable personal protective equipment.
4.1.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See General directions for use.
4.1.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
See General directions for use.
4.1.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
See General directions for use.
5. GENERAL DIRECTIONS FOR USE OF THE META SPC 7
5.1. Instructions for use
Unless otherwise stated on the label, products must be diluted for use.
Follow the label instructions for use dilutions and application volumes according to the use required.
Surfaces shall be cleaned before disinfection.
See Use-specific instructions for use per use
5.2. Risk mitigation measures
—
No access of third parties during application/treatment/maintenance, unless the required personal protective equipment as prescribed for the professional user is worn.
—
Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m 3 ) or relevant lower national reference value
5.3. Particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
First-Aid measures
IF INHALED: Move to fresh air and keep at rest in a position comfortable for breathing. If symptoms: Call 112/ambulance for medical assistance. If no symptoms: Call a POISON CENTRE or a doctor.
IF SWALLOWED: Immediately rinse mouth. Give something to drink, if exposed person is able to swallow. Do NOT induce vomiting. Call 112/ambulance for medical assistance. Information to Healthcare personnel/doctor: Initiate life support measures if needed, thereafter call a POISON CENTRE.
IF ON SKIN: Immediately wash skin with plenty of water. Thereafter take off all contaminated clothing and wash it before reuse. Continue to wash the skin with water for 15 minutes. Call a POISON CENTRE or a doctor.
IF IN EYES: Immediately rinse with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing for at least 15 minutes. Call 112/ambulance for medical assistance. Information to Healthcare personnel/doctor: The eyes should also be rinsed repeatedly on the way to the doctor if eye exposure to alkaline chemicals (pH > 11), amines and acids like acetic acid, formic acid or propionic acid
Fire-fighting measures
Extinguishing media:
Suitable extinguishing media: In case of fire involving the product: Water spray Unsuitable extinguishing media: All other extinguishants.
Special hazards arising from the substance or mixture: Contact with combustible material may cause fire. Thermal decomposition gives: Oxygen, that can enhance sites of combustion. Hazards of over-pressurization in containers exposed to heat: explosion risk.
Precautions for fire-fighters: Specific methods: Keep upwind and operate from safe distance. In case of fire, remove exposed containers. Containers/tanks should be cooled with water spray.
Special protective actions for fire-fighters: Wear self-contained breathing apparatus and protective suit.
Accidental release measures
Personal precautions, protective equipment and emergency procedures:
Evacuate non-essential staff and those not equipped with individual protection apparatus. Prohibit contact with eyes. Avoid contact with skin. Avoid inhalation of vapours. Prohibit all sources of sparks and ignition - Do not smoke. If safe to do so, plug or seal off leak. Remove all incompatible substances.
Environmental precautions: Dam up with sand or inert earth (do not use combustible materials). Dilute with large quantities of water before discharging into sewers or into the environment
Methods and materials for containment and cleaning up:
Recovery : Soak up with inert absorbent material. Never reintroduce the spilled product in another container. Risk of decomposition.
Neutralisation : Dilute with water.
Elimination : Dispose of rinse water as waste water.
5.4. Instructions for safe disposal of the product and its packaging
Waste treatment
Disposal of product: Dilute with water.
Disposal of packaging: Clean container with water. Recycle or incinerate at an approved waste disposal site. In accordance with local and national regulations.
5.5. Conditions of storage and shelf-life of the product under normal conditions of storage
Shelf-life of 1 year.
The product should be stored in the original packaging.
Protect from light.
Store below 54 °C.
6. OTHER INFORMATION
Council Directive 98/24/EC of 7 April 1998 on the protection of the health and safety of workers from the risks related to chemical agents at work (fourteenth individual Directive within the meaning of Article 16(1) of Directive 89/391/EEC) ( OJ L 131, 5.5.1998, p. 11 ).
Professionals (including industrial, professionals) mean trained professional if this is required by national legislation.
Please be aware of the European reference value of 1,25 mg/m 3 for the active substance hydrogen peroxide (CAS No.: 7722-84-1) which was used for the risk assessment for the biocidal product (please be aware that relevant lower national limit values may apply).
The full titles of the EN standards referenced in the Risk mitigation measures are:
—
EN 13832 – Footwear protecting against chemicals
—
EN 374 – Protective gloves against dangerous chemicals and micro-organisms
—
EN 405 – Respiratory protective devices
—
EN 166 – Eye protection against chemicals
—
EN 13034 – Protective coverall against liquid chemicals – type 6
7. THIRD INFORMATION LEVEL: INDIVIDUAL PRODUCTS IN THE META SPC 7
7.1. Trade name(s), authorisation number and specific composition of each individual product
Trade name(s)
HYDROCYDE
Market area: EU
RAIDOX
Market area: EU
Authorisation number
EU-0035039-0018 1-7
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
35 % (w/w)
7.2. Trade name(s), authorisation number and specific composition of each individual product
Trade name(s)
RAIDOX
Market area: EU
Authorisation number
EU-0035039-0019 1-7
Common name
IUPAC name
Function
CAS number
EC number
Content (%)
hydrogen peroxide
hydrogen peroxide
Active substance
7722-84-1
231-765-0
35 % (w/w)