My bookmarksSign up free

Directive 2004/107/EC of the European Parliament and of the… ANNEX IV

Directive 2004/107/EC of the European Parliament and of the… ANNEX IV

Data quality objectives and requirements for air quality models

ANNEX IVSupplementary provisions

ANNEX IV Data quality objectives and requirements for air quality models I.   Data quality objectives The following data quality objectives are provided as a guide to quality assurance.   Benzo(a)pyrene Arsenic, cadmium and nickel Polycyclic aromatic hydrocarbons other than benzo(a)pyrene, total gaseous mercury Total deposition — Uncertainty         Fixed and indicative measurements 50 % 40 % 50 % 70 % Modelling 60 % 60 % 60 % 60 % — Minimum data capture 90 % 90 % 90 % 90 % — Minimum time coverage:         Fixed measurements 33 % 50 %     Indicative measurements  ( *1 ) 14 % 14 % 14 % 33 % The uncertainty (expressed at a 95 % confidence level) of the methods used for the assessment of ambient air concentrations will be evaluated in accordance with the principles of the CEN Guide to the expression of uncertainty in measurement (ENV 13005-1999), the methodology of ISO 5725:1994, and the guidance provided in the CEN Report, ‘Air quality — Approach to uncertainty estimation for ambient air reference measurement methods’ (CR 14377:2002E). The percentages for uncertainty are given for individual measurements, which are averaged over typical sampling times, for a 95 % confidence interval. The uncertainty of the measurements should be interpreted as being applicable in the region of the appropriate target value. Fixed and indicative measurements must be evenly distributed over the year in order to avoid skewing of results. The requirements for minimum data capture and time coverage do not include losses of data due to regular calibration or normal maintenance of the instrumentation. Twenty-four-hour sampling is required for the measurement of benzo(a)pyrene and other polycyclic aromatic hydrocarbons. With care, individual samples taken over a period of up to one month can be combined and analysed as a composite sample, provided the method ensures that the samples are stable for that period. The three congeners benzo(b)fluoranthene, benzo(j)fluoranthene, benzo(k)fluoranthene can be difficult to resolve analytically. In such cases they can be reported as sum. Twenty-four hour sampling is also advisable for the measurement of arsenic, cadmium and nickel concentrations. Sampling must be spread evenly over the weekdays and the year. For the measurement of deposition rates monthly, or weekly, samples throughout the year are recommended. Member States may use wet only instead of bulk sampling if they can demonstrate that the difference between them is within 10 %. Deposition rates should generally be given as μg/m 2 per day. Member States may apply a minimum time coverage lower than indicated in the table, but not lower than 14 % for fixed measurements and 6 % for indicative measurements provided that they can demonstrate that the 95 % expanded uncertainty for the annual mean, calculated from the data quality objectives in the table according to ISO 11222:2002 — ‘Determination of the uncertainty of the time average of air quality measurements’ will be met. II.   Requirements for air quality models Where an air quality model is used for assessment, references to descriptions of the model and information on the uncertainty shall be compiled. The uncertainty for modelling is defined as the maximum deviation of the measured and calculated concentration levels, over a full year, without taking into account the timing of the events. III.   Requirements for objective estimation techniques Where objective estimation techniques are used, the uncertainty shall not exceed 100 %. IV.   Standardisation For substances to be analysed in the PM 10 fraction, the sampling volume refers to ambient conditions. ( *1 )   Indicative measurement being measurements which are performed at reduced regularity but fulfil the other data quality objectives.

Read the full instrument →

Other provisions in Directive 2004/107/EC of the European Parliament and of the…

Compiled from an official source version. Later amendments or repeals may not be reflected; the official text prevails. · Read the official text ↗ · Data as of 2026-07-04

CitationANNEX IV of Directive 2004/107/EC of the European Parliament and of the… (LawPlayer, data as of 2026-07-04)

© European Union, https://eur-lex.europa.eu, 1998-2026. Reuse authorised under Commission Decision 2011/833/EU, provided the source is acknowledged.

What to look at next