ANNEX IVSupplementary provisions
ANNEX IV MODEL OF ANALYTICAL REPORT Note: please compile an annex form for each sample tested Parameter to be reported Information provided Name and address of the test laboratory ( *1 ) Test report identification code ( *1 ) <<000>> Laboratory sample identification code ( *1 ) <<000>> Size of laboratory sample ( *1 ) X kg In case of sample division: Number and size of analytical samples X analytical samples of Y g Number and size of test portions analysed ( *1 ) X test portions of Y mg Total DNA amount analysed ( *1 ) X ng/PCR DNA sequence(s) tested for ( *1 ) : For each of the following provide reference to the method used and the average Ct number obtained Rice marker: 35S promoter: NOS terminator: CryIAb/CryIAc: Other sequence(s) tested for: Validation status: (e.g. inter-laboratory validated, in-house validated [please indicate according to which standard, guideline]) Description of DNA sequences detected (reference + target genes): Specificity of the method (screening, construct-specific or event-specific): Absolute Limit of Detection (copy number): Practical Limit of Detection (LOD related to the sample analysed), if determined: Description of positive controls for target DNA, and reference materials ( *1 ) Source and nature of the positive control and reference materials (e.g. plasmid, genomic DNA, CRM …) Information on the positive control ( *1 ) Please indicate the amount (in ng DNA) of positive control analysed and the average Ct number obtained Comments ( *1 ) Obligatory fields