My bookmarksSign up free

Commission Delegated Regulation (EU) No 626/2011 ANNEX VII

Commission Delegated Regulation (EU) No 626/2011 ANNEX VII

ANNEX VIISupplementary provisions

ANNEX VII Measurements and calculations 1. For the purposes of compliance and verification of compliance with the requirements of this Regulation, measurements and calculations shall be made using harmonised standards the reference numbers of which have been published in the Official Journal of European Union , or other reliable, accurate and reproducible method, which takes into account the generally recognised state of the art methods, and whose results are deemed to be of low uncertainty. 2. The determination of the seasonal energy consumption and seasonal energy efficiency ratio (SEER) and seasonal coefficient of performance (SCOP) shall take into account: (a) European seasonal conditions, as defined in Table 1 of this Annex; (b) Reference design conditions, as defined in Table 3 of this Annex; (c) Electric energy consumption for all relevant modes of operation, using time periods as defined in Table 4 of this Annex; (d) Effects of the degradation of the energy efficiency caused by on/off cycling (if applicable) depending on the type of control of the cooling and/or heating capacity; (e) Corrections on the seasonal coefficients of performance in conditions where the heating load can not be met by the heating capacity; (f) The contribution of a back-up heater (if applicable) in the calculation of the seasonal efficiency of a unit in heating mode. 3. Where the information relating to a specific model, being a combination of indoor and outdoor unit(s), has been obtained by calculation on the basis of design, and/or extrapolation from other combinations, the documentation should include details of such calculations and/or extrapolations, and of tests undertaken to verify the accuracy of the calculations undertaken (including details of the mathematical model for calculating performance of such combinations, and of measurements taken to verify this model). 4. The energy efficiency ratio (EER rated ) and, when applicable, coefficient of performance (COP rated ) for double ducts and single ducts shall be established at the standard rating conditions as defined in Table 2 of this Annex. 5. The calculation of electricity consumption for cooling and/or heating shall take into account electric energy consumption of all relevant modes of operation, when appropriate, using time periods as defined in Table 4 of this Annex. Table 1 Bin number (j), outdoor temperature (Tj) in °C and number of hours per bin (hj) for the cooling season and for heating seasons ‘average’, ‘warmer’ and ‘colder’. ‘db’ = dry bulb temperature COOLING SEASON   HEATING SEASON             Average Warmer Colder j # Tj °C hj h   j # T j °C hjA h hj W h hjC h   db       db       1 17 205   1 to 8 – 30 to – 23 0 0 0 2 18 227   9 –22 0 0 1 3 19 225   10 –21 0 0 6 4 20 225   11 –20 0 0 13 5 21 216   12 –19 0 0 17 6 22 215   13 –18 0 0 19 7 23 218   14 –17 0 0 26 8 24 197   15 –16 0 0 39 9 25 178   16 –15 0 0 41 10 26 158   17 –14 0 0 35 11 27 137   18 –13 0 0 52 12 28 109   19 –12 0 0 37 13 29 88   20 –11 0 0 41 14 30 63   21 –10 1 0 43 15 31 39   22 –9 25 0 54 16 32 31   23 –8 23 0 90 17 33 24   24 –7 24 0 125 18 34 17   25 –6 27 0 169 19 35 13   26 –5 68 0 195 20 36 9   27 –4 91 0 278 21 37 4   28 –3 89 0 306 22 38 3   29 –2 165 0 454 23 39 1   30 –1 173 0 385 24 40 0   31 0 240 0 490         32 1 280 0 533         33 2 320 3 380         34 3 357 22 228         35 4 356 63 261         36 5 303 63 279         37 6 330 175 229         38 7 326 162 269         39 8 348 259 233         40 9 335 360 230         41 10 315 428 243         42 11 215 430 191         43 12 169 503 146         44 13 151 444 150         45 14 105 384 97         46 15 74 294 61 Total   2 602       4 910 3 590 6 446 Table 2 Standard rating conditions, temperatures in ‘dry bulb’ air temperature (‘wet bulb’ indicated in brackets) Appliance Function Indoor air temperature (°C) Outdoor air temperature (°C) air conditioners, excluding single duct cooling 27 (19) 35 (24) heating 20 (max. 15) 7(6) single duct cooling 35 (24) 35 (24)  ( *1 ) heating 20 (12) 20 (12)  ( *1 ) Table 3 Reference design conditions, temperatures in ‘dry bulb’ air temperature (‘wet bulb’ indicated in brackets) Function / season Indoor air temperature (°C) Outdoor air temperature (°C) Bivalent temperature (°C) Operating limit temperature (°C)   Tin Tdesignc/Tdesignh Tbiv Tol cooling 27 (19) Tdesignc = 35 (24) n.a. n.a. heating / Average 20 (15) Tdesignh = – 10 (– 11) max. 2 max. – 7 heating / Warmer Tdesignh = 2 (1) max. 7 max. 2 heating / Colder Tdesignh = – 22 (– 23) max. – 7 max. – 15 Table 4 Operational hours per type of appliance per functional mode to be used for calculation of electricity consumption Type of appliance / functionality (if applicable) Unit Heating season On mode Thermostat-off mode Standby mode Off mode Crankcase heater mode       cooling: H CE heating: H HE H TO H SB H OFF H CK Air conditioners, except double ducts and single duct Cooling mode, if appliance offers cooling only h/annum   350 221 2 142 5 088 7 760 Cooling and heating modes, if appliance offers both modes Cooling mode h/annum   350 221 2 142 0 2 672 Heating mode h/annum Average 1 400 179 0 0 179 Warmer 1 400 755 0 0 755 Colder 2 100 131 0 0 131 Heating mode, if appliance offers heating only h/annum Average 1 400 179 0 3 672 3 851 Warmer 1 400 755 0 4 345 4 476 Colder 2 100 131 0 2 189 2 944 Double duct air conditioner     cooling: H CE heating: H HE H TO H SB H OFF H CK Cooling mode, if appliance offers cooling only h/60 min   1 n/a n/a n/a n/a Cooling and heating modes, if appliance offers both modes Cooling mode h/60 min   1 n/a n/a n/a n/a Heating mode h/60 min   1 n/a n/a n/a n/a Heating mode, if appliance offers heating only h/60 min   1 n/a n/a n/a n/a Single duct air conditioner     cooling: H CE heating: H HE         Cooling mode h/60 min   1 n/a n/a n/a n/a Heating mode h/60 min   1 n/a n/a n/a n/a ( *1 )   In case of single ducts, the condensor (evaporator) when cooling (heating), is not supplied with outdoor air, but indoor air.

Read the full instrument →

Other provisions in Commission Delegated Regulation (EU) No 626/2011

Compiled from an official source version. Later amendments or repeals may not be reflected; the official text prevails. · Read the official text ↗ · Data as of 2026-07-04

CitationANNEX VII of Commission Delegated Regulation (EU) No 626/2011 (LawPlayer, data as of 2026-07-04)

© European Union, https://eur-lex.europa.eu, 1998-2026. Reuse authorised under Commission Decision 2011/833/EU, provided the source is acknowledged.

What to look at next