Commission Regulation (EU) 2015/1095 ANNEX IV

Commission Regulation (EU) 2015/1095 ANNEX IV

ANNEX IVSupplementary provisions

ANNEX IV Measurements and calculations for professional refrigerated storage cabinets 1. For the purposes of compliance and verification of compliance with the requirements of this Regulation, measurements and calculations shall be made using harmonised standards the reference numbers of which have been published for that purpose in the Official Journal of the European Union , or using other reliable, accurate and reproducible methods that take into account the generally recognised state-of-the-art methods. In the case of professional refrigerated storage cabinets, they shall meet the conditions and technical parameters set out in points 2 and 3. 2. For establishing the values of annual energy consumption and energy efficiency index for professional refrigerated storage cabinets, measurements shall be made under the following conditions: (a) The temperature of test packages shall be between – 1 °C and 5 °C for chilled cabinets and lower than – 15 °C for frozen cabinets; (b) The ambient conditions shall correspond to climate class 4 as detailed in Table 3, except for light-duty cabinets which shall be tested in ambient conditions corresponding to climate class 3. Adjustment factors of 1,2 for light-duty cabinets at chilled operating temperature and 1,1 for light-duty cabinets at frozen operating temperature should then be applied to the testing results thus obtained for light-duty cabinets for the purpose of information declaration according to Annex II, point 2(a); (c) Professional refrigerated storage cabinets shall be tested: — at chilled operating temperature in the case of a combined cabinet containing at least one compartment exclusively intended for chilled operating temperature; — at chilled operating temperature in the case of a professional refrigerated storage cabinet which has solely one compartment exclusively intended for chilled operating temperature; — at frozen operating temperature in all other cases. 3. The ambient conditions of climate classes 3, 4 and 5 are shown in Table 3. Table 3 Ambient conditions of climate classes 3, 4 and 5 Test room climate class Dry bulb temperature, °C Relative humidity, % Dew point, °C Water vapour mass in dry air, g/kg 3 25 60 16,7 12,0 4 30 55 20,0 14,8 5 40 40 23,9 18,8

Read the full instrument →

Other provisions in Commission Regulation (EU) 2015/1095

Compiled from an official source version. Later amendments or repeals may not be reflected; the official text prevails. · Read the official text ↗ · Data as of 2026-07-04

CitationANNEX IV of Commission Regulation (EU) 2015/1095 (LawPlayer, data as of 2026-07-04)

© European Union, https://eur-lex.europa.eu, 1998-2026. Reuse authorised under Commission Decision 2011/833/EU, provided the source is acknowledged.

What to look at next