My bookmarksSign up free

Regulation (EU) 2016/1628 ANNEX II

Regulation (EU) 2016/1628 ANNEX II

ANNEX IISupplementary provisions

ANNEX II Exhaust emission limits referred to in Article 18(2) Table II-1: Stage V emission limits for engine category NRE defined in point (1) of Article 4(1) Emission stage Engine sub-category Power range Ignition type CO HC NO x PM mass PN A     kW   g/kWh g/kWh g/kWh g/kWh #/kWh   Stage V NRE-v-1 NRE-c-1 0 < P < 8 CI 8,00 (HC + NO x  ≤ 7,50) 0,40  ( 1 ) — 1,10 Stage V NRE-v-2 NRE-c-2 8 ≤ P < 19 CI 6,60 (HC + NO x  ≤ 7,50) 0,40 — 1,10 Stage V NRE-v-3 NRE-c-3 19 ≤ P < 37 CI 5,00 (HC + NO x  ≤ 4,70) 0,015 1 × 10 12 1,10 Stage V NRE-v-4 NRE-c-4 37 ≤ P < 56 CI 5,00 (HC + NO x  ≤ 4,70) 0,015 1 × 10 12 1,10 Stage V NRE-v-5 NRE-c-5 56 ≤ P < 130 all 5,00 0,19 0,40 0,015 1 × 10 12 1,10 Stage V NRE-v-6 NRE-c-6 130 ≤ P ≤ 560 all 3,50 0,19 0,40 0,015 1 × 10 12 1,10 Stage V NRE-v-7 NRE-c-7 P > 560 all 3,50 0,19 3,50 0,045 — 6,00 Table II-2: Stage V emission limits for engine category NRG defined in point (2) of Article 4(1) Emission stage Engine sub-category Power range Ignition type CO HC NO x PM mass PN A     kW   g/kWh g/kWh g/kWh g/kWh #/kWh   Stage V NRG-v-1 NRG-c-1 P > 560 all 3,50 0,19 0,67 0,035 — 6,00 Table II-3: Stage V emission limits for engine category NRSh defined in point (3) of Article 4(1) Emission stage Engine sub-category Power range Ignition type CO HC + NO x     kW   g/kWh g/kWh Stage V NRSh-v-1a 0 < P < 19 SI 805 50 Stage V NRSh-v-1b 603 72 Table II-4: Stage V emission limits for engine category NRS defined in point (4) of Article 4(1) Emission stage Engine sub-category Power range Ignition type CO HC + NO x     kW   g/kWh g/kWh Stage V NRS-vr-1a NRS-vi-1a 0 < P < 19 SI 610 10 Stage V NRS-vr-1b NRS-vi-1b 610 8 Stage V NRS-v-2a 19 ≤ P ≤ 30 610 8 Stage V NRS-v-2b NRS-v-3 19 ≤ P < 56 4,40  ( *1 ) 2,70  ( *1 ) Table II-5: Stage V emission limits for engine category IWP defined in point (5) of Article 4(1) Emission stage Engine sub-category Power range Ignition type CO HC NO x PM mass PN A     kW   g/kWh g/kWh g/kWh g/kWh #/kWh   Stage V IWP-v-1 IWP-c-1 19 ≤ P < 75 all 5,00 (HC + NO x  ≤ 4,70) 0,30 — 6,00 Stage V IWP-v-2 IWP-c-2 75 ≤ P < 130 all 5,00 (HC + NO x  ≤ 5,40) 0,14 — 6,00 Stage V IWP-v-3 IWP-c-3 130 ≤ P < 300 all 3,50 1,00 2,10 0,10 — 6,00 Stage V IWP-v-4 IWP-c-4 P ≥ 300 all 3,50 0,19 1,80 0,015 1 × 10 12 6,00 Table II-6: Stage V emission limits for engine category IWA defined in point (6) of Article 4(1) Emission stage Engine sub-category Power range Ignition type CO HC NO x PM mass PN A     kW   g/kWh g/kWh g/kWh g/kWh #/kWh   Stage V IWA-v-1 IWA-c-1 19 ≤ P < 75 all 5,00 (HC + NO x  ≤ 4,70) 0,30 — 6,00 Stage V IWA-v-2 IWA-c-2 75 ≤ P < 130 all 5,00 (HC + NO x  ≤ 5,40) 0,14 — 6,00 Stage V IWA-v-3 IWA-c-3 130 ≤ P < 300 all 3,50 1,00 2,10 0,10 — 6,00 Stage V IWA-v-4 IWA-c-4 P ≥ 300 all 3,50 0,19 1,80 0,015 1 × 10 12 6,00 Table II-7: Stage V emission limits for engine category RLL defined in point (7) of Article 4(1) Emission stage Engine sub-category Power range Ignition type CO HC NO x PM mass PN A     kW   g/kWh g/kWh g/kWh g/kWh #/kWh   Stage V RLL-c-1 RLL-v-1 P > 0 all 3,50 (HC + NO x  ≤ 4,00) 0,025 — 6,00 Table II-8: Stage V emission limits for engine category RLR defined in point (8) of Article 4(1) Emission stage Engine sub-category Power range Ignition type CO HC NO x PM mass PN A     kW   g/kWh g/kWh g/kWh g/kWh #/kWh   Stage V RLR-c-1 RLR-v-1 P > 0 all 3,50 0,19 2,00 0,015 1 × 10 12 6,00 Table II-9: Stage V emission limits for engine category SMB defined in point (9) of Article 4(1) Emission stage Engine sub-category Power range Ignition type CO NO x HC     kW   g/kWh g/kWh g/kWh Stage V SMB-v-1 P > 0 SI 275 — 75 Table II-10: Stage V emission limits for engine category ATS defined in point (10) of Article 4(1) Emission stage Engine sub-category Power range Ignition type CO HC + NO x     kW   g/kWh g/kWh Stage V ATS-v-1 P > 0 SI 400 8 Specific provisions on total hydrocarbon (HC) limits for fully and partially gaseous-fuelled engines 1. For the sub-categories where an A-factor is defined, the HC limit for fully and partially gaseous-fuelled engines indicated in Tables II-1 to II-10 is replaced by a limit calculated using the following formula: HC = 0,19 + (1,5 × A × GER) where GER is the average gas energy ratio over the appropriate test cycle. Where both a steady-state and transient test cycle apply, the GER shall be determined from the hot-start transient test cycle. Where more than one steady-state test cycle applies, the average GER shall be determined for each cycle individually. If the calculated limit for HC exceeds the value of 0,19 + A, the limit for HC shall be set to 0,19 + A. Figure 1. Diagram showing HC emission limit as function of average GER Average gas energy ratio (GER), % 20 60 40 80 100 0 0,19 0,19+A 2. For sub-categories with a combined HC and NO x limit, the combined limit value for HC and NO x shall be reduced by 0,19 g/kWh and apply for NO x only. 3. For non-gaseous-fuelled engines, the formula does not apply. ( 1 )   0,60 for hand-startable, air-cooled direct injection engines. ( *1 )   Optionally, as an alternative, any combination of values satisfying the equation (HC + NO X ) × CO 0,784  ≤ 8,57 as well as the following conditions: CO ≤ 20,6 g/kWh and (HC + NO X ) ≤ 2,7 g/kWh

Read the full instrument →

Other provisions in Regulation (EU) 2016/1628

Compiled from an official source version. Later amendments or repeals may not be reflected; the official text prevails. · Read the official text ↗ · Data as of 2026-07-04

CitationANNEX II of Regulation (EU) 2016/1628 (LawPlayer, data as of 2026-07-04)

© European Union, https://eur-lex.europa.eu, 1998-2026. Reuse authorised under Commission Decision 2011/833/EU, provided the source is acknowledged.

What to look at next