ANNEX IISupplementary provisions
ANNEX II Ecodesign requirements 1. SPECIFIC ECODESIGN REQUIREMENTS FOR SERVERS AND ONLINE DATA STORAGE PRODUCTS 1.1. PSU efficiency and power factor requirements 1.1.1. From 1 March 2020, for servers and online data storage products, with the exception of direct current servers and of direct current data storage products, the PSU efficiency at 10 %, 20 %, 50 % and 100 % of the rated load level and the power factor at 50 % of the rated load level shall not be less than the values reported in Table 1. Table 1 Minimum PSU efficiency and power factor requirements from 1 March 2020 Minimum PSU efficiency Minimum power factor % of rated load 10 % 20 % 50 % 100 % 50 % Multi output — 88 % 92 % 88 % 0,90 Single output — 90 % 94 % 91 % 0,95 1.1.2. From 1 January 2023, for servers and online data storage products, with the exception of direct current servers and of direct current data storage products, the PSU efficiency at 10 %, 20 %, 50 % and 100 % of the rated load level and the power factor at 50 % of the rated load level shall not be less than the values reported in Table 2. Table 2 Minimum PSU efficiency and power factor requirements from 1 January 2023 Minimum PSU efficiency Minimum power factor % of rated load 10 % 20 % 50 % 100 % 50 % Multi output — 90 % 94 % 91 % 0,95 Single output 90 % 94 % 96 % 91 % 0,95 1.2. Material efficiency requirements 1.2.1. From 1 March 2020, manufacturers shall ensure that joining, fastening or sealing techniques do not prevent the disassembly for repair or reuse purposes of the following components, when present: (a) data storage devices; (b) memory; (c) processor (CPU); (d) motherboard; (e) expansion card/graphic card; (f) PSU; (g) chassis; (h) batteries. 1.2.2. From 1 March 2020, a functionality for secure data deletion shall be made available for the deletion of data contained in all data storage devices of the product. 1.2.3. From 1 March 2021, the latest available version of the firmware shall be made available from two years after the placing on the market of the first product of a certain product model for a minimum period of eight years after the placing on the market of the last product of a certain product model, free of charge or at a fair, transparent and non-discriminatory cost. The latest available security update to the firmwares shall be made available from the time a product model is placed on the market until at least eight years after the placing on the market of the last product of a certain product model, free of charge. 2. SPECIFIC ECODESIGN REQUIREMENTS ONLY FOR SERVERS WITH ONE OR TWO PROCESSOR SOCKETS 2.1. Idle state power From 1 March 2020, the idle state power ( P idle ) of servers, with the exception of resilient servers, HPC servers and servers with integrated APA, shall not exceed the value calculated using the following equation: P idle = P base + Σ P add_i where P base is the basic idle state power allowance in Table 3, and Σ P add_i is the sum of the idle state power allowances for applicable, additional components, as determined per Table 4. For blade servers, P idle is calculated as the total measured power divided by the number of installed blade servers in the tested blade chassis. For multi-node servers, the number of sockets are counted per node while P idle is calculated as the total measured power divided by the number of installed nodes in the tested enclosure. Table 3 Base idle state power allowances Product type Base idle state power allowance, P base (W) 1-socket servers (neither blade nor multi-node servers) 25 2-socket servers (neither blade nor multi-node servers) 38 Blade or multi-node servers 40 Table 4 Additional Idle Power Allowances for Extra Components System characteristics Applies to Additional idle power allowance CPU Performance All servers 1 socket: 10 × Perf CPU W 2 socket: 7 × Perf CPU W Additional PSU PSU installed explicitly for power redundancy 10 W per PSU HDD or SSD Per installed HDD or SSD 5,0 W per HDD or SSD Additional memory Installed memory greater than 4 GB 0,18 W per GB Additional buffered DDR channel Installed buffered DDR channels greater than 8 channels 4,0 W per buffered DDR channel Additional I/O devices Installed devices greater than two ports of ≥ 1 Gbit, onboard Ethernet < 1 Gb/s: No Allowance = 1 Gb/s: 2,0 W/Active Port > 1 Gb/s and < 10 Gb/s: 4,0 W/Active Port ≥ 10 Gb/s and < 25Gb/s: 15,0 W/Active Port ≥ 25 Gb/s and < 50Gb/s: 20,0 W/Active Port ≥ 50 Gb/s 26,0 W/Active Port 2.2. Active state efficiency From 1 March 2020, the active state efficiency (Eff server ) of servers, with the exception of resilient servers, HPC servers and servers with integrated APA, shall not be lower than the values in Table 5. Table 5 Active state efficiency requirements Product type Minimum active state efficiency 1-socket servers 9,0 2-socket servers 9,5 Blade or multi-node servers 8,0 3. INFORMATION TO BE PROVIDED BY MANUFACTURERS 3.1. From 1 March 2020, with the exception of custom made servers, made on a one-off basis, the following product information on servers shall be provided in the instruction manuals for installers and end-users (when present with the product), and on the free-access websites of manufacturers, their authorised representatives and importers from the time a product model is placed on the market until at least eight years after the placing on the market of the last product of a certain product model: (a) product type; (b) manufacturer's name, registered trade name and registered trade address at which they can be contacted; (c) product model number, and if applicable the low-end performance configuration and the high-end performance configuration model numbers; (d) year of manufacture; (e) PSU efficiency at 10 % (if applicable), 20 %, 50 % and 100 % of rated output power, with the exception of direct current servers, expressed in % and rounded to the first decimal place; (f) power factor at 50 % of the rated load level, with the exception of direct current servers, rounded to three decimal places; (g) PSU rated power output (Watts), rounded to the nearest integer. If a product model is part of a server product family, all PSUs offered in a server product family shall be reported with the information specified in (e) and (f); (h) idle state power, expressed in Watts and rounded to the first decimal place; (i) list of all components for additional idle power allowances, if any (additional PSU, HDDs or SSDs, additional memory, additional buffered DDR channels, additional I/O devices); (j) maximum power, expressed in Watts and rounded to the first decimal place; (k) declared operating condition class, as detailed in Table 6; (l) idle state power (Watts) at the higher boundary temperature of the declared operating condition class; (m) the active state efficiency and the performance in active state of the server; (n) information on the secure data deletion functionality referred to in point 1.2.2 of this Annex, including instructions on how to use the functionality, the techniques used and the supported secure data deletion standard(s), if any; (o) for blade servers, a list of recommended combinations with compatible chassis; (p) if a product model is part of a server product family, a list of all model configurations that are represented by the model shall be supplied. If a product model is part of a server product family, the product information required for items e) to m) under point 3.1 shall be reported for the low-end and high-end performance configurations of the server product family. 3.2. From 1 March 2020, with the exception of custom made data storage products, made on a one-off basis, the following product information on online data storage products shall be provided in the instruction manuals for installers and end-users (when present with the product), and on the free-access websites of manufacturers, their authorised representatives and importers from the time a product model is placed on the market until at least eight years after the placing on the market of the last product of a certain product model: (a) product type; (b) manufacturer's name, registered trade name and registered trade address at which they can be contacted; (c) product model number; (d) year of manufacture; (e) PSU efficiency at 10 % (if applicable), 20 %, 50 % and 100 % of rated output power, with the exception of direct current online data storage products, expressed in % and rounded to the first decimal place; (f) power factor at 50 % of the rated load level, with the exception of direct current online data storage products, rounded to three decimal places; (g) declared operating condition class, as detailed in Table 6; it shall also be indicated that ‘This product has been tested in order to verify that it will function within the boundaries (such as temperature and humidity) of the declared operating condition class’; (h) information on the data deletions tool(s) referred to in point 1.2.2 of this Annex, including instructions on how to use the functionality, the techniques used and the supported secure data deletion standard(s), if any. 3.3. From 1 March 2020, the following product information on servers and online data storage products shall be made available from the time a product model is placed on the market until at least eight years after the placing on the market of the last product of a certain product model free of charge by manufacturers, their authorised representatives and importers to third parties dealing with maintenance, repair, reuse, recycling and upgrading of servers (including brokers, spare parts repairers, spare parts providers, recyclers and third party maintenance) upon registration by the interested third party on a website provided: (a) indicative weight range (less than 5 g, between 5 g and 25 g, above 25 g) at component level, of the following critical raw materials: (a) Cobalt in the batteries; (b) Neodymium in the HDDs; (b) instructions on the disassembly operations referred to in point 1.2.1 of this Annex, including, for each necessary operation and component: (a) the type of operation; (b) the type and number of fastening technique(s) to be unlocked; (c) the tool(s) required. In the case of servers, if a product model is part of a server product family, the product information required for items a) and b) under point 3.3 shall be reported either for the product model or, alternatively, for the low-end and high-end configurations of the server product family. 3.4. From 1 March 2020, the following product information on servers and online data storage products shall be provided in the technical documentation for the purposes of conformity assessment pursuant to Article 4: (a) Information listed in points 3.1 and 3.3, in the case of servers (b) Information listed in points 3.2 and 3.3, in the case of data storage products Table 6 Operating condition classes Dry bulb temp °C Humidity range, non-condensing Operating condition class Allowable range Recommended range Allowable range Recommended range Max dew point (°C) Maximum rate of change (°C/hr) A1 15- 32 18-27 – 12 °C Dew Point (DP) and 8 % relative humidity (RH) to 17 °C DP and 80 % RH – 9 °C DP to 15 °C DP and 60 % RH 17 5/20 A2 10-35 18-27 – 12 °C DP and 8 % RH to 21 °C DP and 80 % RH Same as A1 21 5/20 A3 5-40 18-27 – 12 °C DP and 8 % RH to 24 °C DP and 85 % RH Same as A1 24 5/20 A4 5-45 18-27 – 12 °C DP and 8 % RH to 24 °C DP and 90 % RH Same as A1 24 5/20