My bookmarksSign up free

PD 1096 Section 1501

Section 1501

SECTION 1501. Prefabricated Assembly. (a) Prefabricated assembly is a structural unit, the integral parts of which have built up or assembled prior to incorporation in the building. (b) The Secretary shall prescribe special tests to determine the structural adequacy, durability, soundness, weather and fire resistance of the prefabricated assemblies. (c) Every device or system to connect prefabricated assemblies shall be capable of developing the strength of the different members as an integral structure, Except, in the case of members forming part of a structural frame as specified in this Code. Anchorages and connections between members and the supporting elements of the structure or walls shall be capable of withstanding all probable external and internal forces or other conditions for structurally adequate construction. In structural design, proper allowances shall be made for any material to be displaced or removed for the installation of pipes, conduits, or other equipment. (d) Placement of prefabricated assemblies shall be inspected to determine compliance with this Code.

Read the full instrument →

Other provisions in PD 1096

Compiled from an official source version. Later amendments or repeals may not be reflected; the official text prevails. · Read the official text ↗ · Data as of July 4, 2026

CitationPD 1096 Section 1501 (LawPlayer, data as of July 4, 2026)

Source: Supreme Court E-Library, Republic of the Philippines. Philippine laws are public documents (works of the government).