Section 1608
SECTION 1608. Exterior Veneer. (a) General Exterior veneer may be of approved plastic materials, and shall conform to the provisions of this Section. (b) Height Plastic veneer shall not be attached to any exterior wall above the first storey: Provided, that plastic veneer may be attached to exterior walls above the first storey of buildings located outside of highly restrictive Fire Zones: Provided, further that the height of the veneer is not in excess of 10.00 meters above the adjacent of elevation. (c) Area Sections of plastic veneer shall not exceed 15.00 square meters in area, Except, that in less restrictive Fire Zones, the area may be increased by fifty percent. (d) Separation Sections of plastic veneer shall be separated by a minimum of 1.20 meters vertically and 600 millimeters horizontally.