LawPlayer
My bookmarksSign up freeSign up free
Source

Commission Implementing Regulation (EU) 2018/2066 CHAPTER III — MONITORING OF EMISSIONS FROM STATIONARY INSTALLATIONS

Article 19–Article 39 · 21 articles

Compiled from an official source version. Later amendments or repeals may not be reflected; the official text prevails. · Read the official text ↗

SECTION 1 — General provisions

Categorisation of installations, source streams and emission sources

Article 19

Open ↗

1.   For the purpose of monitoring emissions and determining the minimum requirements for tiers, each operator shall determine the category of its installation pursuant to paragraph 2, and, where relevant, of each source stream pursuant to paragraph 3 and of each emission source pursuant to paragraph 4. 2.   The operator shall classify each installation in one of the following categories: (a)  a category A installation, where the average verified annual emissions in the trading period immediately preceding the current trading period, with the exclusion of CO 2 stemming from  zero-rated carbon and before subtraction of transferred CO 2 , are equal to or less than 50 000  tonnes of CO 2(e) ; (b)  a category B installation, where the average verified annual emissions of the trading period immediately preceding the current trading period, with the exclusion of CO 2 stemming from  zero-rated carbon and before subtraction of transferred CO 2 , are more than 50 000 tonnes of CO 2(e) and equal to or less than 500 000 tonnes of CO 2(e) ; (c)  a category C installation, where the average verified annual emissions of the trading period immediately preceding the current trading period, with the exclusion of CO 2 stemming from  zero-rated carbon and before subtraction of transferred CO 2 , are more than 500 000 tonnes of CO 2(e) . By way of derogation from Article 14(2), the competent authority may allow the operator not to modify the monitoring plan where, on the basis of verified emissions, the threshold for the classification of the installation referred to in the first subparagraph is exceeded, but the operator demonstrates to the satisfaction of the competent authority that this threshold has not already been exceeded within the past five reporting periods and will not be exceeded again in subsequent reporting periods. 3.   The operator shall classify each source stream in one of the following categories, comparing it against the sum of all absolute values of fossil CO 2 and CO 2(e) corresponding to all source streams included in calculation-based methodologies and of all emissions of emission sources monitored using measurement-based methodologies, before subtraction of transferred CO 2 : (a)  minor source streams, where the source streams selected by the operator jointly account for less than 5 000 tonnes of fossil CO 2 per year or less than 10 %, up to a total maximum of 100 000 tonnes of fossil CO 2 per year, whichever is greater in terms of absolute value; (b)  de minimis source streams, where the source streams selected by the operator jointly account for less than 1 000  tonnes of fossil CO 2 per year or less than 2 %, up to a total maximum of 20 000 tonnes of fossil CO 2 per year, whichever is greater in terms of absolute value; (c)  major source streams, where the source streams do not fall within the categories referred to in points (a) and (b). By way of derogation from Article 14(2), the competent authority may allow the operator not to modify the monitoring plan where, on the basis of verified emissions, the threshold for the classification of a source stream as a minor source stream or a de minimis source stream referred to in the first subparagraph is exceeded, but the operator demonstrates to the satisfaction of the competent authority that this threshold has not already been exceeded within the past five reporting periods and will not be exceeded again in subsequent reporting periods. 4.   The operator shall classify each emission source for which a measurement-based methodology is applied in one of the following categories: (a)  minor emission sources, where the emission source emits less than 5 000 tonnes of fossil CO 2(e) per year or less than 10 % of the installation's total fossil emissions, up to a maximum of 100 000 tonnes of fossil CO 2(e) per year, whichever is greater in terms of absolute value; (b)  major emission sources, where the emission source does not classify as a minor emission source. By way of derogation from Article 14(2), the competent authority may allow the operator not to modify the monitoring plan where, on the basis of verified emissions, the threshold for the classification of an emission source as a minor emission source referred to in the first subparagraph is exceeded, but the operator demonstrates to the satisfaction of the competent authority that this threshold has not already been exceeded within the past five reporting periods and will not be exceeded again in subsequent reporting periods. 5.   Where the average annual verified emissions in the trading period immediately preceding the current trading period for the installation are not available or no longer representative for the purpose of paragraph 2, the operator shall use a conservative estimate of annual average emissions, with the exclusion of CO 2 stemming from  zero-rated carbon and before subtraction of transferred CO 2 , to determine the category of the installation. —————

Monitoring boundaries

Article 20

Open ↗

1.   Operators shall define the monitoring boundaries for each installation. Within those boundaries, the operator shall include all relevant greenhouse gas emissions from all emission sources and source streams belonging to activities carried out at the installation and listed in Annex I to Directive 2003/87/EC, and from activities and greenhouse gases included by the Member State in which the installation is situated, pursuant to Article 24 of that Directive. The operator shall also include emissions from regular operations and abnormal events, including start-up, shut-down and emergency situations, over the reporting period, with the exception of emissions from mobile machinery for transportation purposes. 2.   When determining the monitoring and reporting process, the operator shall include the sector-specific requirements laid down in Annex IV. 3.   Where leakages from a storage complex within the meaning of Directive 2009/31/EC are identified and lead to emissions or release of CO 2 to the water column, they shall be considered as emission sources for the installation in question and shall be monitored in accordance with section 23 of Annex IV to this Regulation. The competent authority may allow the exclusion of a leakage emission source from the monitoring and reporting process, once corrective measures pursuant to Article 16 of Directive 2009/31/EC have been taken and emissions or release into the water column from that leakage can no longer be detected.

Choice of the monitoring methodology

Article 21

Open ↗

1.   For the monitoring of the emissions of an installation, the operator shall choose to apply either a calculation-based methodology or a measurement-based methodology, subject to specific provisions of this Regulation. A calculation-based methodology shall consist in determining emissions from source streams on the basis of activity data obtained by means of measurement systems and additional parameters from laboratory analyses or default values. The calculation-based methodology may be implemented according to the standard methodology set out in Article 24 or the mass-balance methodology set out in Article 25. A measurement-based methodology shall consist in determining emissions from emission sources by means of continuous measurement of the concentration of the relevant greenhouse gas in the flue gas and of the flue-gas flow, including the monitoring of CO 2 transfers between installations where the CO 2 concentration and the flow of the transferred gas are measured. Where the calculation-based methodology is applied, the operator shall determine for each source stream, in the monitoring plan, whether the standard methodology or the mass-balance methodology is used, including the relevant tiers in accordance with Annex II. 2.   Subject to approval by the competent authority, the operator may combine standard methodology, mass-balance and measurement-based methodologies for different emission sources and source streams belonging to one installation, provided that neither gaps nor double counting concerning emissions occur. 3.   Where sector-specific requirements laid down in Annex IV require the use of a specific monitoring methodology, the operator shall use that methodology or a measurement-based methodology. The operator may choose a different methodology only if it provides the competent authority with evidence that the use of the required methodology is technically not feasible or incurs unreasonable costs, or that the alternative methodology leads to a higher overall accuracy of emissions data.

Monitoring methodology not based on tiers

Article 22

Open ↗

By way of derogation from Article 21(1), the operator may use a monitoring methodology that is not based on tiers (hereinafter ‘the fall-back methodology’) for selected source streams or emission sources, provided that all of the following conditions are met: (a)  applying at least tier 1 under the calculation-based methodology for one or more major source streams or minor source streams and a measurement-based methodology for at least one emission source related to the same source streams is technically not feasible or would incur unreasonable costs; (b)  the operator assesses and quantifies each year the uncertainties of all parameters used for the determination of the annual emissions in accordance with the ISO guide to the expression of uncertainty in measurement (JCGM 100:2008) or another equivalent internationally accepted standard, and includes the results in the annual emissions report; (c)  the operator demonstrates to the satisfaction of the competent authority that by applying such a fall-back monitoring methodology, the overall uncertainty thresholds for the annual level of greenhouse gas emissions for the whole installation do not exceed 7,5 % for category A installations, 5,0 % for category B installations and 2,5 % for category C installations.

Temporary changes to the monitoring methodology

Article 23

Open ↗

1.   Where it is for technical reasons temporarily not feasible to apply the monitoring plan as approved by the competent authority, the operator concerned shall apply the highest achievable tier, or a conservative no-tier approach if application of a tier is not achievable, until the conditions for application of the tier approved in the monitoring plan have been restored. The operator shall take all necessary measures to allow the prompt resumption of the application of the monitoring plan as approved by the competent authority. 2.   The operator concerned shall notify the competent authority of the temporary change referred to in paragraph 1 to the monitoring methodology without undue delay to the competent authority, specifying: (a)  the reasons for deviating from the monitoring plan as approved by the competent authority; (b)  the details of the interim monitoring methodology that the operator is using to determine the emissions until the conditions for the application of the monitoring plan as approved by the competent authority have been restored; (c)  the measures the operator is taking to restore the conditions for the application of the monitoring plan as approved by the competent authority; (d)  the anticipated point in time when application of the monitoring plan as approved by the competent authority will be resumed.

SECTION 2 — Calculation-based methodology
Subsection 1 — General

Calculation of emissions under the standard methodology

Article 24

Open ↗

1.   Under the standard methodology, the operator shall calculate combustion emissions of each source stream by multiplying the activity data related to the amount of fuel combusted, expressed as terajoules based on net calorific value (NCV), by the corresponding emission factor, expressed as tonnes of CO 2 per terajoule (t CO 2 /TJ) consistent with the use of NCV, and the corresponding oxidation factor. 1a.   For the purpose of reporting memo-items, the operator shall also calculate for each source stream combusted and for fuels used as process input the following parameters which are defined by these calculations: (i)  the total preliminary emissions shall be calculated by multiplying the activity data related to the amount of fuel combusted, expressed as tonnes or normal cubic metres, by the corresponding preliminary emission factor and the corresponding oxidation factor; (ii)  biomass emissions shall be calculated by multiplying the total preliminary emissions by the biomass fraction; (iii)  zero-rated biomass emissions shall be calculated by multiplying the total preliminary emissions by the zero-rated biomass fraction; (iv)  emissions from RFNBO, RCF or synthetic low-carbon fuels shall be calculated by multiplying the total preliminary emissions by the RFNBO or RCF fraction or the synthetic low-carbon fraction; (v)  emissions from zero-rated RFNBO, RCF or synthetic low-carbon fuels shall be calculated by multiplying the total preliminary emissions by the zero-rated RFNBO or RCF fraction or the zero-rated synthetic low-carbon fraction. 2.   The operator shall determine process emissions per source stream by multiplying the activity data related to the material consumption, throughput or production output, expressed in tonnes or normal cubic metres, by the corresponding emission factor, expressed in t CO 2 /t or t CO 2 /Nm 3 , and the corresponding conversion factor. 2a.   For the purpose of reporting memo-items, the operator shall also calculate for each source stream relating to process emissions the following parameters which are defined by these calculations: (i)  The total preliminary emissions shall be calculated by multiplying the activity data related to the material consumption, throughput or production output, expressed in tonnes or normal cubic metres, by the corresponding emission factor, expressed in t CO 2 /t or t CO 2 /Nm 3 , and the corresponding conversion factor; (ii)  Biomass emissions shall be calculated by multiplying the total preliminary emissions by the relevant biomass fraction; (iii)  Zero-rated biomass emissions shall be calculated by multiplying the total preliminary emissions by the relevant zero-rated biomass fraction. 3.   Where a tier 1 or tier 2 emission factor already includes the effect of incomplete chemical reactions, the oxidation factor or conversion factor shall be set to 1.

Calculation of emissions under the mass balance methodology

Article 25

Open ↗

1.   Under the mass balance methodology, the operator shall calculate the quantity of CO 2 corresponding to each source stream included in the mass balance by multiplying the activity data related to the amount of fuel, material or CO 2 transferred entering or leaving the boundaries of the mass balance, with the fuel’s, material’s or CO 2 transfer’s carbon content multiplied by its fossil fraction and by 3,664 t CO 2 /t C, applying Section 3 of Annex II to this Regulation. 1a.   For the purpose of reporting memo-items, the operator shall also calculate for each source stream covered by the mass balance the following parameters which are defined by these calculations: (i)  The total preliminary quantity of CO 2 shall be calculated by multiplying the activity data related to the amount of fuel or material entering or leaving the boundaries of the mass balance, with the fuel’s or material’s carbon content and by 3,664 t CO 2 /t C; (ii)  The quantity of CO 2 relating to biomass shall be calculated by multiplying the total preliminary quantity of CO 2 by the biomass fraction; (iii)  The quantity of CO 2 relating to zero-rated biomass shall be calculated by multiplying the total preliminary quantity of CO 2 by the zero-rated biomass fraction; (iv)  If applicable, the quantity of CO 2 relating to RFNBO, RCF or synthetic low-carbon fuels shall be calculated by multiplying the total preliminary quantity of CO 2 by the RFNBO or RCF fraction or the synthetic low-carbon fraction; (v)  If applicable, the quantity of CO 2 relating to zero-rated RFNBO, RCF or synthetic low-carbon fuels shall be calculated by multiplying the total preliminary quantity of CO 2 by the zero-rated RFNBO or RCF fraction or the zero-rated synthetic low-carbon fraction. 2.   Notwithstanding Article 49, the emissions of the total process covered by the mass balance shall be the sum of the CO 2 quantities corresponding to all source streams covered by the mass balance. CO emitted to the atmosphere shall be calculated in the mass balance as emission of the molar equivalent amount of CO 2 . 3.   Where the operator uses a mass balance in accordance with this Article, and zero-rated carbon is contained in input materials or fuels, and output materials contain carbon, the operator shall provide to the competent authority data on the zero-rated fraction of the carbon content of the output streams. The operator shall thereby provide evidence that the installation’s total emissions are not systematically underestimated by the applied monitoring methodology and that the total mass of carbon corresponding to the zero-rated carbon fractions of the carbon contained in all relevant output materials, is not lower than the total mass of zero-rated fractions of the carbon contained in input materials and fuels. For the purpose of the first subparagraph, Article 39, paragraphs 3 and 4 shall apply regarding the zero-rated biomass fraction of biogas and natural gas used as input.

Applicable tiers

Article 26

Open ↗

1.   When defining the relevant tiers for major and minor source streams in accordance with Article 21(1), to determine the activity data and each calculation factor, each operator shall apply the following: (a)  at least the tiers listed in Annex V, in the case of a category A installation, or where a calculation factor is required for a source stream that is a commercial standard fuel; (b)  in other cases than those referred to in point (a), the highest tier as defined in Annex II. However, for major source streams the operator may apply a tier one level lower than required in accordance with the first subparagraph for category C installations and up to two levels lower for category A and B installations, with a minimum of tier 1, where it shows to the satisfaction of the competent authority that the tier required in accordance with the first subparagraph is technically not feasible or incurs unreasonable costs. The competent authority may, for a transitional period agreed with the operator, allow an operator to apply tiers for major source streams that are lower than those referred to in the second subparagraph, with a minimum of tier 1, provided that: (a)  the operator shows to the satisfaction of the competent authority that the tier required pursuant to the second subparagraph is technically not feasible or incurs unreasonable costs; and (b)  the operator provides an improvement plan indicating how and by when at least the tier required pursuant to the second subparagraph will be reached. 2.   For minor source streams, the operator may apply a lower tier than required in accordance with the first subparagraph of paragraph 1, with a minimum of tier 1, where it shows to the satisfaction of the competent authority that the tier required in accordance with the first subparagraph of paragraph 1 is technically not feasible or incurs unreasonable costs. 3.   For de minimis source streams, the operator may determine activity data and each calculation factor by using conservative estimates instead of using tiers, unless a defined tier is achievable without additional effort. 4.   For the oxidation factor and conversion factor, the operator shall, as a minimum, apply the lowest tiers listed in Annex II. 5.   Where the competent authority has allowed the use of emission factors expressed as t CO 2 /t or t CO 2 /Nm 3 for fuels, and for fuels used as process input or in mass balances in accordance with Article 25, the net calorific value may be monitored using a conservative estimate instead of using tiers, unless a defined tier is achievable without additional effort.

Subsection 2 — Activity data

Determination of activity data

Article 27

Open ↗

1.   The operator shall determine the activity data of a source stream in one of the following ways: (a)  on the basis of continual metering at the process which causes the emissions; (b)  on the basis of aggregation of metering of quantities delivered separately, taking into account relevant stock changes. 2.   For the purposes of point (b) of paragraph 1, the quantity of fuel or material processed during the reporting period shall be calculated as the quantity of fuel or material received during the reporting period, minus the quantity of fuel or material moved out of the installation, plus the quantity of fuel or material in stock at the beginning of the reporting period, minus the quantity of fuel or material in stock at the end of the reporting period. Where it is technically not feasible or would incur unreasonable costs to determine quantities in stock by direct measurement, the operator may estimate those quantities on the basis of one of the following: (a)  data from previous years correlated with output for the reporting period; (b)  documented procedures and respective data in audited financial statements for the reporting period. Where it is technically not feasible or would incur unreasonable costs to determine activity data for the entire calendar year, the operator may choose the next most appropriate day to separate one reporting year from the subsequent year, and reconcile accordingly to the calendar year required. The deviations involved for one or more source streams shall be clearly recorded, form the basis of a value representative for the calendar year, and be considered consistently in relation to the next year.

Measurement systems under the operator's control

Article 28

Open ↗

1.   To determine activity data in accordance with Article 27, the operator shall use metering results based on measurement systems under its own control at the installation, provided that all of the following conditions are complied with: (a)  the operator must carry out an uncertainty assessment and ensures that the uncertainty threshold of the relevant tier level is met; (b)  the operator must ensure at least once a year and after each calibration of a measuring instrument that the calibration results multiplied by a conservative adjustment factor are compared with the relevant uncertainty thresholds. The conservative adjustment factor shall be based on an appropriate time series of previous calibrations of that or similar measuring instruments for taking into account the effect of uncertainty in service. Where tier thresholds approved in accordance with Article 12 are exceeded or equipment found not to conform with other requirements, the operator shall take corrective action without undue delay and notify the competent authority thereof. 2.   When notifying a new monitoring plan or when it is relevant for a change to the approved monitoring plan, the operator shall provide the competent authority with the uncertainty assessment referred to in point (a) of paragraph 1. The assessment shall cover the specified uncertainty of the applied measuring instruments, uncertainty associated with the calibration, and any additional uncertainty connected to how the measuring instruments are used in practice. The uncertainty assessment shall cover uncertainty related to stock changes where the storage facilities are capable of containing at least 5 % of the annual used quantity of the fuel or material considered. When carrying out the assessment, the operator shall take into account the fact that the stated values used to define tier uncertainty thresholds in Annex II refer to the uncertainty over the full reporting period. The operator may simplify the uncertainty assessment by assuming that the maximum permissible errors specified for the measuring instrument in service or, where lower, the uncertainty obtained by calibration, multiplied by a conservative adjustment factor for taking into account the effect of uncertainty in service, are to be regarded as the uncertainty over the whole reporting period as required by the tier definitions in Annex II, provided that measuring instruments are installed in an environment appropriate for their use specifications. 3.   Notwithstanding paragraph 2, the competent authority may allow the operator to use metering results based on measurement systems under its own control at the installation, where the operator provides evidence that the measuring instruments applied are subject to relevant national legal metrological control. For that purpose, the maximum permissible error in service allowed by the relevant national legislation on legal metrological control for the relevant measuring task may be used as the uncertainty value without providing further evidence.

Measurement systems outside the operator's own control

Article 29

Open ↗

1.   Where, based on a simplified uncertainty assessment, the use of measurement systems outside the operator's own control, as compared with the use of those within the operator's own control pursuant to Article 28, allows the operator to comply with at least as high a tier, gives more reliable results and is less prone to control risks, the operator shall determine the activity data from measurement systems outside its own control. To that end, the operator may revert to one of the following data sources: (a)  amounts from invoices issued by a trade partner, provided that a commercial transaction between two independent trade partners takes place; (b)  direct readings from the measurement systems. 2.   The operator shall ensure compliance with the applicable tier pursuant to Article 26. To that end, the maximum permissible error in service allowed by relevant legislation for national legal metrological control for the relevant commercial transaction may be used as uncertainty without providing further evidence. Where the applicable requirements under national legal metrological control are less stringent than the applicable tier pursuant to Article 26, the operator shall obtain evidence on the applicable uncertainty from the trade partner responsible for the measurement system.

Subsection 3 — Calculation factors

Determination of calculation factors

Article 30

Open ↗

1.   The operator shall determine calculation factors either as default values or values based on analysis, depending on the applicable tier. 2.   The operator shall determine and report calculation factors consistently with the state used for related activity data, referring to the fuel's or material's state in which the fuel or material is purchased or used in the emission-causing process, before it is dried or otherwise treated for laboratory analysis. Where such an approach incurs unreasonable costs or where higher accuracy can be achieved, the operator may consistently report activity data and calculation factors referring to the state in which laboratory analyses are carried out. ————— 2a.   The operator shall determine the biomass fraction only for mixed fuels or materials containing biomass. For other fuels or materials, the default value of 0 % for the biomass fraction of fossil fuels or materials shall be used, and a default value of 100 % biomass fraction for biomass fuels or materials consisting exclusively of biomass. The operator shall determine the RFNBO or RCF fraction or the synthetic low-carbon fraction only for mixed fuels containing RFNBOs, RCFs or synthetic low-carbon fuels. For other fuels the default value of 0 % for the RFNBO or RCF fraction or the synthetic low-carbon fraction shall be used, and a default value of 100 % RFNBO or RCF fraction or synthetic low-carbon fraction for fuels consisting exclusively of RFNBOs, RCFs or synthetic low-carbon fuels. The operator shall determine the zero-rated biomass fraction, zero-rated RFNBO or RCF fraction and zero-rated synthetic low-carbon fraction only where the operator wants to make use of zero-rating. 3.   Regarding the interdependency of composition-related calculation factors, the operator shall apply the following rules: (i)  Where a fuel or material contains biomass, the operator shall determine the biomass fraction in accordance with Article 39 of this Regulation. (ii)  Where the biomass fraction is not zero and where the operator wants to make use of zero-rating, the operator shall determine the zero-rated biomass fraction in accordance with Article 38(5) of this Regulation. (iii)  Where a fuel contains an RFNBO, RCF or synthetic low-carbon fuel, the operator shall determine the RFNBO or RCF fraction or the synthetic low-carbon fraction in accordance with Article 39a(1) and (2) of this Regulation. (iv)  Where the RFNBO or RCF fraction is not zero and where the operator wants to make use of zero-rating, the operator shall determine the zero-rated RFNBO or RCF fraction in accordance with Article 39a(3) of this Regulation. (v)  Where the synthetic low-carbon fraction is not zero and where the operator wants to make use of zero-rating, the operator shall determine the zero-rated synthetic low-carbon fraction in accordance with Article 39a(4) of this Regulation. (vi)  Where the zero-rated biomass fraction, the zero-rated RFNBO or RCF fraction or the zero-rated synthetic low-carbon fraction are not zero, the operator shall calculate the zero-rated fraction as the sum of zero-rated biomass fraction, zero-rated RFNBO or RCF fraction and zero-rated synthetic low-carbon fraction. The fossil fraction is the sum of all non-zero-rated fractions. (vii)  The operator shall calculate the emission factor as the preliminary emission factor multiplied by the fossil fraction. For the purpose of point (vi), where the operator does not calculate the zero-rated fraction, the fossil fraction shall be 100 %. By way of derogation from the first subparagraph, the operator may: (i)  determine the biomass fraction as identical to the zero-rated biomass fraction, if the latter is determined based on the mass balance pursuant to Article 30(1) of Directive (EU) 2018/2001; (ii)  determine the RFNBO or RCF fraction as identical to the zero-rated RFNBO or RCF fraction, if the latter is determined based on the mass balance pursuant to Article 30(1) of Directive (EU) 2018/2001; (iii)  determine the synthetic low-carbon fraction as identical to the zero-rated synthetic low-carbon fraction, if the latter is determined based on the mass balance pursuant to Article 30(1) of Directive (EU) 2018/2001.

Default values for calculation factors

Article 31

Open ↗

1.   Where the operator determines calculation factors as default values, it shall use one of the following values, in accordance with the requirement of the applicable tier as set out in Annexes II and VI: (a)  standard factors and stoichiometric factors listed in Annex VI; (b)  standard factors used by the Member State for its national inventory submission to the Secretariat of the United Nations Framework Convention on Climate Change; (c)  literature values agreed with the competent authority, including standard factors published by the competent authority, which are compatible with factors referred to in point (b), but representative of more disaggregated sources of fuel streams; (d)  values specified and guaranteed by the supplier of a fuel or material where the operator can demonstrate to the satisfaction of the competent authority that the carbon content exhibits a 95 % confidence interval of not more than 1 %; (e)  values based on analyses carried out in the past, where the operator can demonstrate to the satisfaction of the competent authority that those values are representative for future batches of the same fuel or material. 2.   The operator shall specify all default values used in the monitoring plan. Where the default values change on an annual basis, the operator shall specify the authoritative applicable source of that value in the monitoring plan. 3.   The competent authority may approve a change of default values for a calculation factor in the monitoring plan pursuant to Article 15(2) only where the operator provides evidence that the new default value leads to a more accurate determination of emissions. 4.   Upon application by the operator, the competent authority may allow that the net calorific value and emission factors of fuels are determined using the same tiers as required for commercial standard fuels provided that the operator submits, at least every three years, evidence that the 1 % interval for the specified calorific value has been met during the last three years. 5.   Upon application by the operator, the competent authority may accept that the stoichiometric carbon content of a pure chemical substance be considered as meeting a tier that would otherwise require analyses carried out in accordance with Articles 32 to 35, if the operator can demonstrate to the satisfaction of the competent authority that using analyses would lead to unreasonable costs and that using the stoichiometric value will not lead to under-estimation of the emissions.

Calculation factors based on analyses

Article 32

Open ↗

1.   The operator shall ensure that any analyses, sampling, calibrations and validations for the determination of calculation factors are carried out by applying methods based on corresponding EN standards. Where such standards are not available, the methods shall be based on suitable ISO standards or national standards. Where no applicable published standards exist, suitable draft standards, industry best-practice guidelines or other scientifically proven methodologies shall be used, limiting sampling and measurement bias. 2.   Where online gas chromatographs or extractive or non-extractive gas analysers are used to determine emissions, the operator shall obtain the competent authority's approval for the use of such equipment. The equipment shall be used only with regard to composition data of gaseous fuels and materials. As minimum quality assurance measures, the operator shall ensure that an initial validation and annually repeated validations of the instrument are performed. 3.   The result of any analysis shall be used only for the delivery period or batch of fuel or material for which the samples have been taken, and for which the samples were intended to be representative. When determining a specific parameter, the operator shall use the results of all analyses made with regard to that parameter.

Sampling plan

Article 33

Open ↗

1.   Where calculation factors are determined by analyses, the operator shall submit to the competent authority for approval, for each fuel or material a sampling plan in the form of a written procedure, which contains information on methodologies for the preparation of samples, including information on responsibilities, locations, frequencies and quantities, and methodologies for the storage and transport of samples. The operator shall ensure that the derived samples are representative for the relevant batch or delivery period and free of bias. Relevant elements of the sampling plan shall be agreed with the laboratory carrying out the analysis for the respective fuel or material, and evidence of that agreement shall be included in the plan. The operator shall make the plan available for the purposes of verification pursuant to Implementing Regulation (EU) 2018/2067. 2.   The operator shall, in agreement with the laboratory carrying out the analysis for the respective fuel or material and subject to the approval of the competent authority, adapt the elements of the sampling plan where analytical results indicate that the heterogeneity of the fuel or material significantly differs from the information on heterogeneity on which the original sampling plan for that specific fuel or material was based.

Use of laboratories

Article 34

Open ↗

1.   The operator shall ensure that laboratories used to carry out analyses for the determination of calculation factors are accredited in accordance with EN ISO/IEC 17025, for the relevant analytical methods. 2.   Laboratories not accredited in accordance with EN ISO/IEC 17025 may be used for the determination of calculation factors only where the operator can demonstrate to the satisfaction of the competent authority that access to laboratories referred to in paragraph 1 is technically not feasible or would incur unreasonable costs, and that the non-accredited laboratory meets requirements equivalent to EN ISO/IEC 17025. 3.   The competent authority shall deem a laboratory to meet requirements equivalent to EN ISO/IEC 17025 within the meaning of paragraph 2 where the operator provides, to the extent feasible, in the form and to a similar level of detail required for procedures pursuant to Article 12(2), evidence in accordance with the second and the third subparagraph of this paragraph. With respect to quality management, the operator shall produce an accredited certification of the laboratory in conformity with EN ISO/IEC 9001, or other certified quality management systems that cover the laboratory. In the absence of such certified quality management systems, the operator shall provide other appropriate evidence that the laboratory is capable of managing its personnel, procedures, documents and tasks in a reliable manner. With respect to technical competence, the operator shall provide evidence that the laboratory is competent and able to generate technically valid results using the relevant analytical procedures. Such evidence shall cover at least the following elements: (a)  management of the personnel's competence for the specific tasks assigned; (b)  suitability of accommodation and environmental conditions; (c)  selection of analytical methods and relevant standards; (d)  where applicable, management of sampling and sample preparation, including control of sample integrity; (e)  where applicable, development and validation of new analytical methods or application of methods not covered by international or national standards; (f)  uncertainty estimation; (g)  management of equipment, including procedures for calibration, adjustment, maintenance and repair of equipment, and record keeping thereof; (h)  management and control of data, documents and software; (i)  management of calibration items and reference materials; (j)  quality assurance for calibration and test results, including regular participation in proficiency testing schemes, applying analytical methods to certified reference materials, or inter-comparison with an accredited laboratory; (k)  management of outsourced processes; (l)  management of assignments, customer complaints, and ensuring timely corrective action.

Frequencies for analyses

Article 35

Open ↗

1.   The operator shall apply the minimum frequencies for analyses for relevant fuels and materials listed in Annex VII. 2.   The competent authority may allow the operator to use a frequency that differs from those referred to in paragraph 1, where minimum frequencies are not available or where the operator demonstrates one of the following: (a)  based on historical data, including analytical values for the respective fuels or materials in the reporting period immediately preceding the current reporting period, any variation in the analytical values for the respective fuel or material does not exceed 1/3 of the uncertainty value to which the operator has to adhere with regard to the activity data determination of the relevant fuel or material; (b)  using the required frequency would incur unreasonable costs. Where an installation operates for part of the year only, or where fuels or materials are delivered in batches that are consumed over more than one calendar year, the competent authority may agree with the operator a more appropriate schedule for analyses, provided that it results in a comparable uncertainty as under point (a) of the first subparagraph.

Subsection 4 — Specific calculation factors

Emission factors for CO 2

Article 36

Open ↗

1.   The operator shall determine activity-specific emission factors for CO 2 emissions. 2.   Emission factors of fuels, including those used as process input, shall be expressed as t CO 2 /TJ. The competent authority may allow the operator to use an emission factor for a fuel expressed as t CO 2 /t or t CO 2 /Nm 3 for combustion emissions, where the use of an emission factor expressed as t CO 2 /TJ incurs unreasonable costs or where at least equivalent accuracy of the calculated emissions can be achieved by using such an emission factor. 3.   For the conversion of the carbon content into the respective value of a CO 2 related emission factor or vice versa , the operator shall use the factor 3,664 t CO 2 /t C.

Oxidation and conversion factors

Article 37

Open ↗

1.   The operator shall use tier 1 as a minimum to determine oxidation or conversion factors. The operator shall use a value of 1 for oxidation or for a conversion factor where the emission factor includes the effect of incomplete oxidation or conversion. However, the competent authority may require operators to always use tier 1. 2.   Where several fuels are used within an installation and tier 3 is to be used for the specific oxidation factor, the operator may ask for the approval of the competent authority for one or both of the following: (a)  the determination of one aggregate oxidation factor for the whole combustion process and to apply it to all fuels; (b)  the attribution of the incomplete oxidation to one major source stream and use of a value of 1 for the oxidation factor of the other source streams. Where mixed fuels are used, the operator shall provide evidence that application of points (a) or (b) of the first subparagraph does not lead to an underestimation of emissions.

Subsection 5 — Treatment of biomass

Biomass source streams

Article 38

Open ↗

1.   The operator may determine the activity data of a  zero-rated carbon source stream without using tiers and providing analytical evidence regarding the  zero-rated carbon content, where that source stream consists exclusively of  zero-rated carbon and the operator can ensure that it is not contaminated with other materials or fuels. ————— 2.    ————— The emission factor of each fuel or material shall be calculated and reported as the preliminary emission factor, determined in accordance with Article 30, multiplied by the fossil fraction of the fuel or material. 3.   Peat, xylite and fossil fractions of mixed fuels or materials shall not be considered biomass. 4.   Where the  zero-rated biomass fraction of mixed fuels or materials is equal or higher than 97 %, or where, due to the amount of the emissions associated with the fossil fraction of the fuel or material, it qualifies as a de minimis source stream, the competent authority may allow the operator to apply no-tier methodologies, including the energy balance method, for determining activity data and relevant calculation factors. ————— 5.    Biofuels, bioliquids and biomass fuels shall fulfil the sustainability and the greenhouse gas emissions saving criteria laid down in paragraphs 2 to 7 and 10 of Article 29 of Directive (EU) 2018/2001, in order to be counted towards the zero-rated biomass fraction of a source stream. However, biofuels, bioliquids and biomass fuels produced from waste and residues, other than agricultural, aquaculture, fisheries and forestry residues are required to fulfil only the criteria laid down in Article 29(10) of Directive (EU) 2018/2001. This subparagraph shall also apply to waste and residues that are first processed into a product before being further processed into biofuels, bioliquids and biomass fuels. Electricity, heating and cooling produced from municipal solid waste shall not be subject to the criteria laid down in Article 29(10) of Directive (EU) 2018/2001. The criteria laid down in paragraphs 2 to 7 and 10 of Article 29 of Directive (EU) 2018/2001 shall apply irrespective of the geographical origin of the biomass. Article 29(10) of Directive (EU) 2018/2001 shall apply to an installation as defined in Article 3(e) of Directive 2003/87/EC. The compliance with the criteria laid down in paragraphs 2 to 7 and 10 of Article 29 of Directive (EU) 2018/2001 shall be assessed in accordance with Articles 30 and 31(1) of that Directive. The criteria may also be considered complied with if the operator provides evidence for a purchase of a quantity of biofuel, bioliquid or biogas connected to the cancellation of the respective quantity in the Union Database set up pursuant to Article 31a or a national database set up by the Member State in accordance with Article 31a(5) of that Directive. In case of subsequent non-compliance regarding the proof of sustainability of the quantities cancelled in the aforementioned databases, the competent authority shall correct the verified emissions accordingly. Where the biomass used does not comply with this paragraph, its carbon content shall be considered as fossil carbon. Where according to the first to sixth subparagraphs of this paragraph, the criteria laid down in paragraphs 2 to 7 and 10 of Article 29 of Directive (EU) 2018/2001 do not apply to biomass, the zero-rated biomass fraction equals its biomass fraction. 6.   By way of derogation from paragraph 5, first subparagraph, Member States, or competent authorities as appropriate, may consider as fulfilled the sustainability and greenhouse gas emissions saving criteria referred to in that paragraph for biofuels, bioliquids and biomass fuels used for combustion from 1 January 2022 to 31 December 2022.

Determination of biomass and fossil fraction

Article 39

Open ↗

1.   For fuels or materials containing biomass, the operator may either assume the absence of biomass and apply a default biomass fraction of 0 % or determine a biomass fraction in accordance with paragraph 2, applying tiers as defined in Section 2.4 of Annex II to this Regulation. 2.   Where, subject to the tier level required, the operator has to carry out analyses to determine the biomass fraction, it shall do so on the basis of a relevant standard and the analytical methods therein, provided that the use of that standard and analytical method are approved by the competent authority. Where, subject to the tier level required, the operator has to carry out analyses to determine the biomass fraction, but the application of the first subparagraph is technically not feasible or would incur unreasonable costs, the operator shall submit an alternative estimation method to determine the biomass fraction to the competent authority for approval. For fuels or materials originating from a production process with defined and traceable input streams, the operator may base the estimation on a material balance of fossil and biomass carbon entering and leaving the process. The Commission may provide guidelines on further applicable estimation methods. ————— 3.   By way of derogation from paragraphs 1 and 2 of this Article and Article 30, except for the purposes of  Article 43(4b), the operator shall not use analyses or estimation methods in accordance with paragraph 2 of this Article to determine the biomass fraction of natural gas received from a gas grid to which biogas is added. The operator may determine that a certain quantity of natural gas from the gas grid is zero-rated biogas by using the methodology set out in paragraph 4. In this case, by way of derogation from Article 30(3), the operator shall consider the biomass fraction to be identical to the zero-rated biomass fraction. 4.   The operator may determine the biomass fraction and identical zero-rated biomass fraction of biogas using purchase records of biogas of equivalent energy content, provided that the operator provides evidence to the satisfaction of the competent authority that: (a)  there is no double counting of the same biogas quantity, in particular that the biogas purchased is not claimed to be used by anyone else, including through a disclosure of a guarantee of origin as defined in Article 2(12) of Directive (EU) 2018/2001; (b)  the operator and the producer of the biogas are connected to the same gas grid. For the purpose of demonstrating compliance with this paragraph, the operator may use the data recorded in a database set up by one or more Member States which enables tracing of transfers of biogas. Compliance with this paragraph may be considered demonstrated if the operator provides evidence for a purchase of a quantity of biogas connected to the cancellation of the respective quantity in the Union Database set up pursuant to Article 31a of Directive (EU) 2018/2001 or a national database set up by the Member States in accordance with Article 31a(5) of that Directive. In case of subsequent non-compliance regarding the proof of sustainability of the quantities cancelled in the aforementioned databases, the competent authority shall correct the verified emissions accordingly.