Commission Regulation (EU) No 814/2013 ANNEX III

Commission Regulation (EU) No 814/2013 ANNEX III

ANNEX IIISupplementary provisions

ANNEX III Measurements 1.   For the purposes of compliance and verification of compliance with the requirements of this Regulation, measurements shall be made using harmonised standards the reference numbers of which have been published for this purpose in the Official Journal of the European Union , or using other reliable, accurate and reproducible methods that take into account the generally recognised state-of-the-art methods. They shall meet the conditions and technical parameters set out in points 2 to 7. 2.   GENERAL CONDITIONS FOR TESTING WATER HEATERS (a) Measurements shall be carried out using the load profiles set out in Table 1; (b) measurements shall be carried out using a 24-hour measurement cycle as follows: — 00:00 to 06:59: no water draw-off, — from 07:00: water draw-offs according to the declared load profile, — from end of last water draw-off until 24:00: no water draw-off; (c) the declared load profile shall be the maximum load profile or the load profile one below the maximum load profile; (d) any heat generator designed for a water heater, and any water heater housing to be equipped with such a heat generator, shall be tested with an appropriate water heater housing and heat generator, respectively; (e) water heaters to be classified as off-peak water heaters are energised for a maximum period of 8 consecutive hours between 22:00 and 07:00 of the 24-hour tapping pattern. At the end of the 24-hour tapping pattern the water heaters are energised till the end of the step. Table 1 Load profiles of water heaters h 3XS XXS XS S Q tap f T m Q tap f T m Q tap f T m Q tap f T m T p kWh l/min °C kWh l/min °C kWh l/min °C kWh l/min °C °C 07:00 0,015 2 25 0,105 2 25       0,105 3 25   07:05 0,015 2 25                     07:15 0,015 2 25                     07:26 0,015 2 25                     07:30 0,015 2 25 0,105 2 25 0,525 3 35 0,105 3 25   07:45                           08:01                           08:05                           08:15                           08:25                           08:30       0,105 2 25       0,105 3 25   08:45                           09:00 0,015 2 25                     09:30 0,015 2 25 0,105 2 25       0,105 3 25   10:00                           10:30                           11:00                           11:30 0,015 2 25 0,105 2 25       0,105 3 25   11:45 0,015 2 25 0,105 2 25       0,105 3 25   12:00 0,015 2 25 0,105 2 25               12:30 0,015 2 25 0,105 2 25               12:45 0,015 2 25 0,105 2 25 0,525 3 35 0,315 4 10 55 14:30 0,015 2 25                     15:00 0,015 2 25                     15:30 0,015 2 25                     16:00 0,015 2 25                     16:30                           17:00                           18:00       0,105 2 25       0,105 3 25   18:15       0,105 2 25       0,105 3 40   18:30 0,015 2 25 0,105 2 25               19:00 0,015 2 25 0,105 2 25               19:30 0,015 2 25 0,105 2 25               20:00       0,105 2 25               20:30             1,05 3 35 0,42 4 10 55 20:45       0,105 2 25               20:46                           21:00       0,105 2 25               21:15 0,015 2 25 0,105 2 25               21:30 0,015 2 25             0,525 5 45   21:35 0,015 2 25 0,105 2 25               21:45 0,015 2 25 0,105 2 25               Q ref 0,345 2,100 2,100 2,100 h M L XL Q tap f T m T p Q tap f T m T p Q tap f T m T p kWh l/min °C °C kWh l/min °C °C kWh l/min °C °C 07:00 0,105 3 25   0,105 3 25   0,105 3 25   07:05 1,4 6 40   1,4 6 40           07:15                 1,82 6 40   07:26                 0,105 3 25   07:30 0,105 3 25   0,105 3 25           07:45         0,105 3 25   4,42 10 10 40 08:01 0,105 3 25           0,105 3 25   08:05         3,605 10 10 40         08:15 0,105 3 25           0,105 3 25   08:25         0,105 3 25           08:30 0,105 3 25   0,105 3 25   0,105 3 25   08:45 0,105 3 25   0,105 3 25   0,105 3 25   09:00 0,105 3 25   0,105 3 25   0,105 3 25   09:30 0,105 3 25   0,105 3 25   0,105 3 25   10:00                 0,105 3 25   10:30 0,105 3 10 40 0,105 3 10 40 0,105 3 10 40 11:00                 0,105 3 25   11:30 0,105 3 25   0,105 3 25   0,105 3 25   11:45 0,105 3 25   0,105 3 25   0,105 3 25   12:00                         12:30                         12:45 0,315 4 10 55 0,315 4 10 55 0,735 4 10 55 14:30 0,105 3 25   0,105 3 25   0,105 3 25   15:00                 0,105 3 25   15:30 0,105 3 25   0,105 3 25   0,105 3 25   16:00                 0,105 3 25   16:30 0,105 3 25   0,105 3 25   0,105 3 25   17:00                 0,105 3 25   18:00 0,105 3 25   0,105 3 25   0,105 3 25   18:15 0,105 3 40   0,105 3 40   0,105 3 40   18:30 0,105 3 40   0,105 3 40   0,105 3 40   19:00 0,105 3 25   0,105 3 25   0,105 3 25   19:30                         20:00                         20:30 0,735 4 10 55 0,735 4 10 55 0,735 4 10 55 20:45                         20:46                 4,42 10 10 40 21:00         3,605 10 10 40         21:15 0,105 3 25           0,105 3 25   21:30 1,4 6 40   0,105 3 25   4,42 10 10 40 21:35                         21:45                         Q ref 5,845 11,655 19,07 h XXL 3XL 4XL Q tap f T m T p Q tap f T m T p Q tap f T m T p kWh l/min °C °C kWh l/min °C °C kWh l/min °C °C 07:00 0,105 3 25   11,2 48 40   22,4 96 40   07:05                         07:15 1,82 6 40                   07:26 0,105 3 25                   07:30                         07:45 6,24 16 10 40                 08:01 0,105 3 25   5,04 24 25   10,08 48 25   08:05                         08:15 0,105 3 25                   08:25                         08:30 0,105 3 25                   08:45 0,105 3 25                   09:00 0,105 3 25   1,68 24 25   3,36 48 25   09:30 0,105 3 25                   10:00 0,105 3 25                   10:30 0,105 3 10 40 0,84 24 10 40 1,68 48 10 40 11:00 0,105 3 25                   11:30 0,105 3 25                   11:45 0,105 3 25   1,68 24 25   3,36 48 25   12:00                         12:30                         12:45 0,735 4 10 55 2,52 32 10 55 5,04 64 10 55 14:30 0,105 3 25                   15:00 0,105 3 25                   15:30 0,105 3 25   2,52 24 25   5,04 48 25   16:00 0,105 3 25                   16:30 0,105 3 25                   17:00 0,105 3 25                   18:00 0,105 3 25                   18:15 0,105 3 40                   18:30 0,105 3 40   3,36 24 25   6,72 48 25   19:00 0,105 3 25                   19:30                         20:00                         20:30 0,735 4 10 55 5,88 32 10 55 11,76 64 10 55 20:45                         20:46 6,24 16 10 40                 21:00                         21:15 0,105 3 25                   21:30 6,24 16 10 40 12,04 48 40   24,08 96 40   21:35                         21:45                         Q ref 24,53 46,76 93,52 3.   CONDITIONS FOR TESTING THE SMART CONTROL COMPLIANCE ( SMART ) OF WATER HEATERS Where the manufacturer deems it appropriate to declare the value of smart as being ‘1’, measurements of the weekly electricity and/or fuel consumption with or without smart controls shall be carried out using a two-week measurement cycle as follows: — days 1 to 5: random sequence of load profiles chosen from the declared load profile and the load profile one below the declared load profile, and smart control disabled, — days 6 and 7: no water draw-offs, and smart control disabled, — days 8 to 12: repetition of the same sequence applied for days 1 to 5, and smart control enabled, — days 13 and 14: no water draw-offs, and smart control enabled, — the difference between the useful energy content measured during days 1 to 7 and the useful energy content measured during days 8 to 14 shall not exceed 2 % of Q ref of the declared load profile. 4.   CONDITIONS FOR TESTING SOLAR WATER HEATERS The solar collector, solar hot water storage tank, pump in the collector loop (if applicable) and heat generator shall be tested separately. Where the solar collector and solar hot water storage tank cannot be tested separately, they shall be tested in combination. The heat generator shall be tested under the conditions set out in point 2 of this Annex. The results shall be used for the calculations set out in point 3(b) of Annex IV under the conditions set out in Tables 2 and 3. For the purpose of establishing Q tota the efficiency of the heat generator using the Joule effect in electric resistance heating elements is assumed to be 100/ CC . 5.   CONDITIONS FOR TESTING HEAT PUMP WATER HEATERS — Heat pump water heaters shall be tested under the conditions set out in Table 4; — heat pump water heaters which use ventilation exhaust air as the heat source shall be tested under the conditions set out in Table 5. Table 2 Average daytime temperature [°C]   January February March April May June July August September October November December Average climate conditions 2,8 2,6 7,4 12,2 16,3 19,8 21,0 22,0 17,0 11,9 5,6 3,2 Table 3 Average global solar irradiance [W/m 2 ]   January February March April May June July August September October November December Average climate conditions 70 104 149 192 221 222 232 217 176 129 80 56 Table 4 Standard rating conditions for heat pump water heaters, temperatures in dry bulb air temperature (wet bulb air temperature indicated in brackets) Heat source Outdoor air Indoor air Exhaust air Brine Water Temperature + 7 °C (+ 6 °C) + 20 °C (maximum + 15 °C) + 20 °C (+ 12 °C) 0 °C (inlet)/– 3 °C (outlet) + 10 °C (inlet)/+ 7 °C (outlet) Table 5 Maximum ventilation exhaust air available [m 3 /h], at a temperature of 20 °C and with humidity of 5,5 g/m 3 Declared load profile XXS XS S M L XL XXL 3XL 4XL Maximum ventilation exhaust air available 109 128 128 159 190 870 1 021 2 943 8 830 6.   TECHNICAL PARAMETERS OF WATER HEATERS The following parameters shall be established for water heaters: (a) the daily electricity consumption Q elec in kWh, rounded to three decimal places; (b) the declared load profile, expressed by the appropriate letter in accordance with Table 1 of this Annex; (c) the sound power level L WA , in dB, indoors, rounded to the nearest integer (for heat pump water heaters, if applicable); in addition, for water heaters using fossil and/or biomass fuels: (d) the daily fuel consumption Q fuel in kWh in terms of GCV , rounded to three decimal places; (e) the emissions of nitrogen oxides, expressed in nitrogen dioxide, in mg/kWh fuel input in terms of GCV , rounded to the nearest integer; in addition, for water heaters for which the value of smart is declared as being ‘1’: (f) the weekly fuel consumption with smart controls Q fuel,week,smart in kWh in terms of GCV , rounded to three decimal places; (g) the weekly electricity consumption with smart controls Q elec,week,smart in kWh, rounded to three decimal places; (h) the weekly fuel consumption without smart controls Q fuel,week in kWh in terms of GCV , rounded to three decimal places; (i) the weekly electricity consumption without smart controls Q elec,week in kWh, rounded to three decimal places; in addition, for storage water heaters with declared load profiles 3XS, XXS and XS: (j) the storage volume V in litres, rounded to one decimal place; in addition, for storage water heaters with declared load profiles M, L, XL, XXL, 3XL and 4XL: (k) the mixed water at 40 °C V40 in litres, rounded to the nearest integer; in addition, for solar water heaters: (l) the collector aperture area A sol in m 2 , rounded to two decimal places; (m) the zero-loss efficiency η 0 , rounded to three decimal places; (n) the first-order coefficient a 1 in W/(m 2 K), rounded to two decimal places; (o) the second-order coefficient a 2 in W/(m 2 K 2 ), rounded to three decimal places; (p) the incidence angle modifier IAM , rounded to two decimal places; (q) the pump power consumption solpump in W, rounded to two decimal places; (r) the standby power consumption solstandby in W, rounded to two decimal places; in addition, for heat pump water heaters: (s) the sound power level L WA in dB, outdoors, rounded to the nearest integer. 7.   TECHNICAL PARAMETERS OF HOT WATER STORAGE TANKS The following parameters shall be established for hot water storage tanks: (a) the storage volume V in litres, rounded to one decimal place; (b) the standing loss S in W, rounded to one decimal place.

Read the full instrument →

Other provisions in Commission Regulation (EU) No 814/2013

Compiled from an official source version. Later amendments or repeals may not be reflected; the official text prevails. · Read the official text ↗ · Data as of 2026-07-04

CitationANNEX III of Commission Regulation (EU) No 814/2013 (LawPlayer, data as of 2026-07-04)

© European Union, https://eur-lex.europa.eu, 1998-2026. Reuse authorised under Commission Decision 2011/833/EU, provided the source is acknowledged.

What to look at next