My bookmarksSign up free

Commission Regulation (EU) No 814/2013 ANNEX IV

Commission Regulation (EU) No 814/2013 ANNEX IV

ANNEX IVSupplementary provisions

ANNEX IV Calculations 1.   For the purposes of compliance and verification of compliance with the requirements of this Regulation, calculations shall be made using harmonised standards the reference numbers of which have been published for this purpose in the Official Journal of the European Union , or using other appropriate calculation methods that take into account the generally recognised state-of-the-art methods. They shall meet the technical parameters and calculations set out in points 2 to 5. Technical parameters used for the calculations shall be measured in accordance with Annex III. 2.   TECHNICAL PARAMETERS OF WATER HEATERS The following parameters shall be calculated for water heaters under average climate conditions: (a) the water heating energy efficiency η wh in %, rounded to one decimal place; in addition, for solar water heaters under average climate conditions: (b) the annual non-solar heat contribution Q nonsol in kWh in terms of primary energy for electricity and/or in kWh in terms of GCV for fuels, rounded to one decimal place; (c) the heat generator water heating energy efficiency η wh,nonsol in %, rounded to one decimal place; (d) the annual auxiliary electricity consumption Q aux in kWh, rounded to one decimal place. 3.   CALCULATION OF THE WATER HEATING ENERGY EFFICIENCY η wh (a) Conventional water heaters and heat pump water heaters The water heating energy efficiency is calculated as follows: For water-/brine-to-water heat pump water heaters, the electricity consumption of one or more ground water pumps shall be taken into account. (b) Solar water heaters The water heating energy efficiency is calculated as follows: Where: 4.   DETERMINATION OF THE SMART CONTROL FACTOR SCF AND OF SMART CONTROL COMPLIANCE smart (a) The smart control factor is calculated as follows: (b) If SCF ≥ 0,07, the value of smart shall be 1. In all other cases, the value of smart shall be 0. 5.   DETERMINATION OF THE AMBIENT CORRECTION TERM Q cor The ambient correction term is calculated as follows: (a) for conventional water heaters using electricity: (b) for conventional water heaters using fuels: (c) for heat pump water heaters: Where: the k-values are given in Table 6 for each load profile. Table 6 k-values   3XS XXS XS S M L XL XXL 3XL 4XL k 0,23 0,23 0,23 0,23 0,23 0,23 0,23 0,0 0,0 0,0

Read the full instrument →

Other provisions in Commission Regulation (EU) No 814/2013

Compiled from an official source version. Later amendments or repeals may not be reflected; the official text prevails. · Read the official text ↗ · Data as of 2026-07-04

CitationANNEX IV of Commission Regulation (EU) No 814/2013 (LawPlayer, data as of 2026-07-04)

© European Union, https://eur-lex.europa.eu, 1998-2026. Reuse authorised under Commission Decision 2011/833/EU, provided the source is acknowledged.

What to look at next