Commission Delegated Regulation (EU) No 1254/2014 ANNEX IV

Commission Delegated Regulation (EU) No 1254/2014 ANNEX IV

Product fiche

ANNEX IVSupplementary provisions

ANNEX IV Product fiche The information in the product fiche of the residential ventilation unit referred to in Article 3(1)(b) shall be given in the following order and shall be included in the product brochure or other literature provided with the product: (a) supplier's name or trade mark; (b) supplier's model identifier i.e. the code, usually alphanumeric, used to distinguish a specific residential ventilation unit model from other models with the same trade mark or supplier's name; (c) specific energy consumption (SEC) in kWh/(m 2 .a) for each applicable climate zone and SEC class; (d) declared typology in accordance with Article 2 of this Regulation (, unidirectional or bidirectional); (e) type of drive installed or intended to be installed (multi-speed drive or variable speed drive); (f) type of heat recovery system (recuperative, regenerative, none); (g) thermal efficiency of heat recovery (in % or ‘not applicable’ if the product has no heat recovery system); (h) maximum flow rate in m 3 /h; (i) electric power input of the fan drive, including any motor control equipment, at maximum flow rate (W); (j) sound power level (L WA ), rounded to the nearest integer; (k) reference flow rate in m 3 /s; (l) reference pressure difference in Pa; (m) SPI in W/(m 3 /h); (n) control factor and control typology in accordance with the relevant definitions and classification in Annex VIII Table 1; (o) declared maximum internal and external leakage rates (%) for bidirectional ventilation units or carry over (for regenerative heat exchangers only), and external leakage rates (%) for ducted unidirectional ventilation units; (p) mixing rate of non-ducted bidirectional ventilation units not intended to be equipped with one duct connection on either supply or extract air side; (q) position and description of visual filter warning for RVUs intended for use with filters, including text pointing out the importance of regular filter changes for performance and energy efficiency of the unit; (r) for unidirectional ventilation systems, instructions to install regulated supply/exhaust grilles in the façade for natural air supply/extraction; (s) internet address for pre-/dis-assembly instructions; (t) for non-ducted units only: the airflow sensitivity to pressure variations at + 20 Pa and – 20 Pa; (u) for non-ducted units only: the indoor/outdoor air tightness in m 3 /h; (v) the annual electricity consumption (AEC) (in kWh electricity/a); (w) the annual heating saved (AHS) (in kWh primary energy/a) for each type of climate (‘average’, ‘warm’, ‘cold’).

Read the full instrument →

Other provisions in Commission Delegated Regulation (EU) No 1254/2014

Compiled from an official source version. Later amendments or repeals may not be reflected; the official text prevails. · Read the official text ↗ · Data as of 2026-07-04

CitationANNEX IV of Commission Delegated Regulation (EU) No 1254/2014 (LawPlayer, data as of 2026-07-04)

© European Union, https://eur-lex.europa.eu, 1998-2026. Reuse authorised under Commission Decision 2011/833/EU, provided the source is acknowledged.

What to look at next