My bookmarksSign up free

Commission Delegated Regulation (EU) 2015/1187 ANNEX V

Commission Delegated Regulation (EU) 2015/1187 ANNEX V

ANNEX VSupplementary provisions

ANNEX V Technical documentation 1.   SOLID FUEL BOILERS For solid fuel boilers, the technical documentation referred to in Article 3(1)(e) shall include: (a) the name and address of the supplier; (b) the model identifier; (c) where appropriate, the references of the harmonised standards applied; (d) where the preferred fuel is other woody biomass, non-woody biomass, other fossil fuel or other blend of biomass and fossil fuel as referred to in Table 4, a description of the fuel sufficient for its unambiguous identification and the technical standard or specification of the fuel, including the measured moisture content and the measured ash content, and for other fossil fuel also the measured volatile content of the fuel; (e) where appropriate, the other technical standards and specifications used; (f) the name and signature of the person empowered to bind the supplier; (g) the information included in Table 4, with its technical parameters measured and calculated in accordance with Annex VIII and IX; (h) reports of tests undertaken by suppliers or on their behalf, including the name and address of the body that conducted the test; (i) any specific precautions that must be taken when the solid fuel boiler is assembled, installed or maintained; (j) a list of equivalent models, if applicable. This information may be merged with the technical documentation provided in accordance with measures under Directive 2009/125/EC of the European Parliament and of the Council  ( 1 ) . Table 4 Technical parameters for solid fuel boilers and solid fuel cogeneration boilers Model identifier Stoking mode: [Manual: the boiler should be operated with a hot water storage tank of a volume of at least x  ( *1 ) litre/Automatic: it is recommended that the boiler be operated with a hot water storage tank of a volume of at least x  ( *2 ) litre] Condensing boiler: [yes/no] Solid fuel cogeneration boiler: [yes/no] Combination boiler: [yes/no] Fuel Preferred fuel (only one): Other suitable fuel(s): Log wood, moisture content ≤ 25 % [yes/no] [yes/no] Chipped wood, moisture content 15-35 % [yes/no] [yes/no] Chipped wood, moisture content > 35 % [yes/no] [yes/no] Compressed wood in the form of pellets or briquettes [yes/no] [yes/no] Sawdust, moisture content ≤ 50 % [yes/no] [yes/no] Other woody biomass [yes/no] [yes/no] Non-woody biomass [yes/no] [yes/no] Bituminous coal [yes/no] [yes/no] Brown coal (including briquettes) [yes/no] [yes/no] Coke [yes/no] [yes/no] Anthracite [yes/no] [yes/no] Blended fossil fuel briquettes [yes/no] [yes/no] Other fossil fuel [yes/no] [yes/no] Blended biomass (30-70 %) and fossil fuel briquettes [yes/no] [yes/no] Other blend of biomass and fossil fuel [yes/no] [yes/no] Characteristics when operating with the preferred fuel: Seasonal space heating energy efficiency η s [%]: Energy efficiency index EEI : Item Symbol Value Unit   Item Symbol Value Unit Useful heat output   Useful efficiency At rated heat output P n  ( *3 ) x,x kW   At rated heat output η n x,x % At [30 %/50 %] of rated heat output, if applicable P p [x,x/N.A.] kW   At [30 %/50 %] of rated heat output, if applicable η p [x,x/ N.A.] % For solid fuel cogeneration boilers: Electrical efficiency   Auxiliary electricity consumption   At rated heat output el max x,xxx kW At rated heat output η el,n x,x %   At [30 %/50 %] of rated heat output, if applicable el min [x,xxx/ N.A.] kW   Of incorporated secondary emission abatement equipment, if applicable [x,xxx/ N.A.] kW   In standby mode P SB x,xxx kW   Contact details Name and address of the supplier   2.   PACKAGES OF A SOLID FUEL BOILER, SUPPLEMENTARY HEATERS, TEMPERATURE CONTROLS AND SOLAR DEVICES For packages of a solid fuel boiler, supplementary heaters, temperature controls and solar devices, the technical documentation referred to in Article 3(3)(e) shall include: (a) the name and address of the supplier; (b) a description of the model comprising the package of a solid fuel boiler, supplementary heaters, temperatures control and solar devices sufficient for its unambiguous identification; (c) where appropriate, the references of the harmonised standards applied; (d) where appropriate, the other technical standards and specifications used; (e) the name and signature of the person empowered to bind the supplier; (f) technical parameters: (1) the energy efficiency index, rounded to the nearest integer; (2) the technical parameters set out in point 1 of this Annex and, where appropriate, the technical parameters set out in point 1 of Annex V of Commission Delegated Regulation (EU) No 811/2013; (3) the technical parameters set out in points 3 and 4 of Annex V of Commission Delegated Regulation (EU) No 811/2013; (g) any specific precautions that must be taken when the package of a solid fuel boiler, supplementary heaters, temperature controls and solar devices is assembled, installed or maintained. ( 1 )   Directive 2009/125/EC of the European Parliament and of the Council of 21 October 2009 establishing a framework for the setting of ecodesign requirements for energy-related products ( OJ L 285, 31.10.2009, p. 10 ). ( *1 )   Tank volume = 45 × P r × (1 – 2,7/ P r ) or 300 litres whichever is higher, with P r indicated in kW ( *2 )   Tank volume = 20 × P r with P r indicated in kW ( *3 )   For the preferred fuel P n equals P r

Read the full instrument →

Other provisions in Commission Delegated Regulation (EU) 2015/1187

Compiled from an official source version. Later amendments or repeals may not be reflected; the official text prevails. · Read the official text ↗ · Data as of 2026-07-04

CitationANNEX V of Commission Delegated Regulation (EU) 2015/1187 (LawPlayer, data as of 2026-07-04)

© European Union, https://eur-lex.europa.eu, 1998-2026. Reuse authorised under Commission Decision 2011/833/EU, provided the source is acknowledged.

What to look at next