ANNEX III
The labels
1. SOLID FUEL BOILERS
1.1. Label 1
(a)
The following information shall be included in the label:
I.
supplier's name or trade mark;
II.
supplier's model identifier;
III.
the space heating function;
IV.
the energy efficiency class, determined in accordance with Annex II; the head of the arrow containing the energy efficiency class of the solid fuel boiler shall be placed at the same height as the head of the relevant energy efficiency class;
V.
the rated heat output in kW, rounded to the nearest integer;
VI.
for combination boilers, also the additional water heating function;
VII.
for solid fuel cogeneration boilers, also the additional electricity generation function.
(b)
The design aspects of the label for solid fuel boilers shall be in accordance with point 3 of this Annex. By way of exception, where a model has been granted an ‘EU Ecolabel’ under Regulation (EC) No 66/2010 of the European Parliament and of the Council ( 1 ) , a copy of the EU Ecolabel may be added.
1.2. Label 2
(a)
The information listed in point 1.1(a) of this Annex shall be included in the label.
(b)
The design aspects of the label for solid fuel boilers shall be in accordance with point 3 of this Annex. By way of exception, where a model has been granted an ‘EU Ecolabel’ under Regulation (EC) No 66/2010 of the European Parliament and of the Council, a copy of the EU Ecolabel may be added.
2. PACKAGES OF A SOLID FUEL BOILER, SUPPLEMENTARY HEATERS, TEMPERATURE CONTROLS AND SOLAR DEVICES
Label for packages of a solid fuel boiler, supplementary heaters, temperature controls and solar devices in energy efficiency classes A +++ to G
(a)
The following information shall be included in the label:
I.
dealer's or supplier's name or trade mark;
II.
dealer's or supplier's model(s) identifier;
III.
the space heating function;
IV.
the energy efficiency class of the solid fuel boiler, determined in accordance with Annex II;
V.
indication of whether a solar collector, hot water storage tank, temperature control or supplementary heater may be included in the package of a solid fuel boiler, supplementary heaters, temperature controls and solar devices;
VI.
the energy efficiency class of the package of a solid fuel boiler, supplementary heaters, temperature controls and solar devices, determined in accordance with point 2 of Annex IV; the head of the arrow containing the energy efficiency class of the package of a solid fuel boiler, supplementary heaters, temperature controls and solar devices shall be placed at the same height as the head of the relevant energy efficiency class.
(b)
The design aspects of the label for packages of a solid fuel boiler, supplementary heaters, temperature controls and solar devices shall be in accordance with point 4 of this Annex. For packages of a solid fuel boiler, supplementary heaters, temperature controls and solar devices in energy efficiency classes A +++ to D, the classes E to G in the A +++ to G scale may be omitted.
3. THE DESIGN OF THE LABEL FOR SOLID FUEL BOILERS SHALL BE THE FOLLOWING:
whereby:
(a)
The label shall be at least 105 mm wide and 200 mm high. Where the label is printed in a larger format, its content shall nevertheless remain proportionate to the specifications above.
(b)
The background shall be white.
(c)
Colours are coded as CMYK — cyan, magenta, yellow and black, following this example: 00-70-X-00: 0 % cyan, 70 % magenta, 100 % yellow, 0 % black.
(d)
The label shall fulfil all of the following requirements (numbers refer to the figure above):
EU label border stroke: 4 pt, colour: cyan 100 %, round corners: 3,5 mm.
EU logo: Colours: X-80-00-00 and 00-00-X-00.
Energy label: Colour: X-00-00-00. Pictogram as depicted: EU logo + energy label: width: 86 mm, height: 17 mm.
Sub-logos border: 1 pt, colour: cyan 100 %, length: 86 mm.
Space heating function:
—
Pictogram as depicted.
A ++ -G and A +++ -D scales, respectively:
—
Arrow: height: 5 mm, gap: 1,3 mm, colours:
—
Highest class: X-00-X-00,
—
Second class: 70-00-X-00,
—
Third class: 30-00-X-00,
—
Fourth class: 00-00-X-00,
—
Fifth class: 00-30-X-00,
—
Sixth class: 00-70-X-00,
—
Seventh class: 00-X-X-00,
—
Eighth class: 00-X-X-00,
—
Last class: 00-X-X-00,
—
Text: Calibri bold 14 pt, capitals, white, ‘+’ symbols: superscript, aligned on a single row;
—
Arrow: height: 7 mm, gap: 1 mm, colours:
—
Highest class: X-00-X-00,
—
Second class: 70-00-X-00,
—
Third class: 30-00-X-00,
—
Fourth class: 00-00-X-00,
—
Fifth class: 00-30-X-00,
—
Sixth class: 00-70-X-00,
—
Last class: 00-X-X-00,
—
Text: Calibri bold 16 pt, capitals, white, ‘+’ symbols: superscript, aligned on a single row.
Energy efficiency class:
—
Arrow: width: 22 mm, height: 12 mm, 100 % black,
—
Text: Calibri bold 24 pt, capitals, white, ‘+’ symbols: superscript, aligned on a single row.
Rated heat output:
—
Border: 2 pt — colour: cyan 100 % — round corners: 3,5 mm,
—
Value ‘YZ’: Calibri bold 45 pt, 100 % black,
—
Text ‘kW’: Calibri regular 30 pt, 100 % black.
Water heating function
—
Pictogram as depicted,
—
Border: 2 pt, colour: cyan 100 %, round corners: 3,5 mm.
Electricity function:
—
Pictogram as depicted,
—
Border: 2 pt, colour: cyan 100 %, round corners: 3,5 mm.
Year of label introduction and number of Regulation:
—
Text: Calibri bold 10 pt.
Supplier's name or trademark.
Supplier's model identifier:
The supplier's name or trade mark and model identifier shall fit in a space of 86 × 12 mm.
4. THE DESIGN OF THE LABEL FOR PACKAGES OF A SOLID FUEL BOILER, SUPPLEMENTARY HEATERS, TEMPERATURE CONTROLS AND SOLAR DEVICES SHALL BE THE FOLLOWING:
whereby:
(a)
The label shall be at least 210 mm wide and 297 mm high. Where the label is printed in a larger format, its content shall nevertheless remain proportionate to the specifications above.
(b)
The background shall be white.
(c)
Colours are coded as CMYK — cyan, magenta, yellow and black, following this example: 00-70-X-00: 0 % cyan, 70 % magenta, 100 % yellow, 0 % black.
(d)
The label shall fulfil all of the following requirements (numbers refer to the figure above):
EU label border stroke: 6 pt, colour: cyan 100 %, round corners: 3,5 mm.
EU logo: Colours: X-80-00-00 and 00-00-X-00.
Energy label: Colour: X-00-00-00. Pictogram as depicted: EU logo + energy label: width: 191 mm, height: 37 mm.
Sub-logos border: 2 pt, colour: cyan 100 %, length: 191 mm.
Space heating function:
—
Pictogram as depicted.
Solid fuel boiler:
—
Pictogram as depicted,
—
Energy efficiency class of solid fuel boiler:
—
Arrow: width: 24 mm, height: 14 mm, 100 % black;
—
Text: Calibri bold 28 pt, capitals, white, ‘+’ symbols: superscript, aligned on a single row,
—
Border: 3 pt, colour: cyan 100 %, round corners: 3,5 mm.
Package with solar collectors, hot water storage tanks, temperature controls and supplementary heaters:
—
Pictograms as depicted,
—
‘+’ symbol: Calibri bold 50 pt, cyan 100 %,
—
Boxes: width: 12 mm, height: 12 mm, border: 4 pt, cyan 100 %,
—
Border: 3 pt, colour: cyan 100 %, round corners: 3,5 mm.
A +++ -G scale with border:
—
Arrow: height: 15 mm, gap: 3 mm, colours:
—
Highest class: X-00-X-00,
—
Second class: 70-00-X-00,
—
Third class: 30-00-X-00,
—
Fourth class: 00-00-X-00,
—
Fifth class: 00-30-X-00,
—
Sixth class: 00-70-X-00,
—
Seventh class: 00-X-X-00,
—
If applicable, last classes: 00-X-X-00,
—
Text: Calibri bold 30 pt, capitals, white, ‘+’ symbols: superscript, aligned on a single row,
—
Border: 3 pt, colour: cyan 100 %, round corners: 3,5 mm.
Energy efficiency class for the package of a solid fuel boiler, supplementary heaters, temperature controls and solar devices:
—
Arrow: width: 33 mm, height: 19 mm, 100 % black,
—
Text: Calibri bold 40 pt, capitals, white, ‘+’ symbols: superscript, aligned on a single row.
Year of label introduction and number of Regulation:
—
Text: Calibri bold 12 pt.
Dealer's or supplier's name or trademark.
Dealer's or supplier's model identifier:
The dealer's or supplier's name or trade mark and model identifier shall fit in a space of 191 × 19 mm.
( 1 ) Regulation (EC) No 66/2010 of the European Parliament and of the Council of 25 November 2009 on the EU Ecolabel ( OJ L 27, 30.1.2010, p. 1 ).