Commission Delegated Regulation (EU) No 811/2013 ANNEX IV

Commission Delegated Regulation (EU) No 811/2013 ANNEX IV

ANNEX IVSupplementary provisions

ANNEX IV Product fiche 1.   SPACE HEATERS 1.1. The information in the product fiche of the space heater shall be provided in the following order and shall be included in the product brochure or other literature provided with the product: (a) supplier’s name or trademark; (b) supplier’s model identifier; (c) the seasonal space heating energy efficiency class of the model, determined in accordance with point 1 of Annex II; (d) the rated heat output, including the rated heat output of any supplementary heater, in kW, rounded to the nearest integer (for heat pump space heaters under average climate conditions); (e) the seasonal space heating energy efficiency in %, rounded to the nearest integer and calculated in accordance with points 3 and 4 of Annex VII (for heat pump space heaters under average climate conditions); (f) the annual energy consumption in kWh in terms of final energy and/or in GJ in terms of GCV , rounded to the nearest integer and calculated in accordance with points 3 and 4 of Annex VII (for heat pump space heaters under average climate conditions); (g) the sound power level L WA , indoors, in dB, rounded to the nearest integer (for heat pump space heaters if applicable); (h) any specific precautions that shall be taken when the space heater is assembled, installed or maintained; in addition, for cogeneration space heaters: (i) the electrical efficiency in %, rounded to the nearest integer; in addition, for heat pump space heaters: (j) the rated heat output, including the rated heat output of any supplementary heater, in kW, under colder and warmer climate conditions, rounded to the nearest integer; (k) the seasonal space heating energy efficiency in %, under colder and warmer climate conditions, rounded to the nearest integer and calculated in accordance with point 4 of Annex VII; (l) the annual energy consumption in kWh in terms of final energy and/or in GJ in terms of GCV , under colder and warmer climate conditions, rounded to the nearest integer and calculated in accordance with point 4 of Annex VII; (m) the sound power level L WA , outdoors, in dB, rounded to the nearest integer. 1.2. One fiche may cover a number of space heater models supplied by the same supplier. 1.3. The information contained in the fiche may be given in the form of a copy of the label, either in colour or in black and white. Where this is the case, the information listed in point 1.1 not already displayed on the label shall also be provided. 2.   COMBINATION HEATERS 2.1. The information in the product fiche of the combination heater shall be provided in the following order and shall be included in the product brochure or other literature provided with the product: (a) supplier’s name or trademark; (b) supplier’s model identifier; (c) for space heating, the medium-temperature application (and for heat pump combination heaters the low-temperature application, if applicable); for water heating, the declared load profile, expressed as the appropriate letter and typical usage in accordance with Table 15 of Annex VII; (d) the seasonal space heating energy efficiency class and the water heating energy efficiency class of the model, determined in accordance with points 1 and 2 of Annex II; (e) the rated heat output, including the rated heat output of any supplementary heater, in kW, rounded to the nearest integer (for heat pump combination heaters under average climate conditions); (f) for space heating, the annual energy consumption in kWh in terms of final energy and/or in GJ in terms of GCV , rounded to the nearest integer and calculated in accordance with points 3 and 4 of Annex VII (for heat pump combination heaters under average climate conditions); for water heating, the annual electricity consumption in kWh in terms of final energy and/or the annual fuel consumption in GJ in terms of GCV , rounded to the nearest integer and calculated in accordance with point 5 of Annex VII (for heat pump combination heaters under average climate conditions); (g) the seasonal space heating energy efficiency in %, rounded to the nearest integer and calculated in accordance with points 3 and 4 of Annex VII (for heat pump combination heaters under average climate conditions); the water heating energy efficiency in %, rounded to the nearest integer and calculated in accordance with point 5 of Annex VII (for heat pump combination heaters under average climate conditions); (h) the sound power level L WA , indoors, in dB, rounded to the nearest integer (for heat pump combination heaters if applicable); (i) if applicable, an indication that the combination heater is able to work only during off-peak hours; (j) any specific precautions that shall be taken when the combination heater is assembled, installed or maintained; in addition, for heat pump combination heaters: (k) the rated heat output, including the rated heat output of any supplementary heater, in kW, under colder and warmer climate conditions, rounded to the nearest integer; (l) for space heating, the annual energy consumption in kWh in terms of final energy and/or in GJ in terms of GCV , under colder and warmer climate conditions, rounded to the nearest integer and calculated in accordance with point 4 of Annex VII; for water heating, the annual electricity consumption in kWh in terms of final energy and/or the annual fuel consumption in GJ in terms of GCV , under colder and warmer climate conditions, rounded to the nearest integer and calculated in accordance with point 5 of Annex VII; (m) the seasonal space heating energy efficiency in %, under colder and warmer climate conditions, rounded to the nearest integer and calculated in accordance with point 4 of Annex VII; the water heating energy efficiency in %, under colder and warmer climate conditions, rounded to the nearest integer and calculated in accordance with point 5 of Annex VII; (n) the sound power level L WA , outdoors, in dB, rounded to the nearest integer. 2.2. One fiche may cover a number of combination heater models supplied by the same supplier. 2.3. The information contained in the fiche may be given in the form of a copy of the label, either in colour or in black and white. Where this is the case, the information listed in point 2.1 not already displayed on the label shall also be provided. 3.   TEMPERATURE CONTROLS 3.1. The information in the product fiche of the temperature control shall be provided in the following order and shall be included in the product brochure or other literature provided with the product: (a) supplier’s name or trade mark; (b) supplier’s model identifier; (c) the class of the temperature control; (d) the contribution of the temperature control to seasonal space heating energy efficiency in %, rounded to one decimal place. 3.2. One fiche may cover a number of temperature control models supplied by the same supplier. 4.   SOLAR DEVICES 4.1. The information in the product fiche of the solar device shall be provided in the following order and shall be included in the product brochure or other literature provided with the product (for pumps in the collector loop if applicable): (a) supplier’s name or trade mark; (b) supplier’s model identifier; (c) the collector aperture area in m 2 , to two decimal places; (d) the collector efficiency in %, rounded to the nearest integer; (e) the energy efficiency class of the solar hot water storage tank, determined in accordance with point 3 of Annex II; (f) the standing loss of the solar hot water storage tank in W, rounded to the nearest integer; (g) the storage volume of the solar hot water storage tank in litres and m 3 ; (h) the annual non-solar heat contribution Q nonsol in kWh in terms of primary energy for electricity and/or in kWh in terms of GCV for fuels, for the load profiles M, L, XL and XXL under average climate conditions, rounded to the nearest integer; (i) the pump power consumption in W, rounded to the nearest integer; (j) the standby power consumption in W, to two decimal places; (k) the annual auxiliary electricity consumption Q aux in kWh in terms of final energy, rounded to the nearest integer. 4.2. One fiche may cover a number of solar device models supplied by the same supplier. 5.   PACKAGES OF SPACE HEATER, TEMPERATURE CONTROL AND SOLAR DEVICE The fiche for packages of space heater, temperature control and solar device shall contain the elements set out in Figure 1, Figure 2, Figure 3 and Figure 4, respectively, for evaluating the seasonal space heating energy efficiency of a package of space heater, temperature control and solar device, including the following information: — I: the value of the seasonal space heating energy efficiency of the preferential space heater, expressed in %; — II: the factor for weighting the heat output of preferential and supplementary heaters of a package as set out in Tables 5 and 6 of this Annex, respectively; — III: the value of the mathematical expression: , whereby Prated is related to the preferential space heater; — IV: the value of the mathematical expression , whereby Prated is related to the preferential space heater; in addition, for preferential heat pump space heaters: — V: the value of the difference between the seasonal space heating energy efficiencies under average and colder climate conditions, expressed in %; — VI: the value of the difference between the seasonal space heating energy efficiencies under warmer and average climate conditions, expressed in %. 6.   PACKAGES OF COMBINATION HEATER, TEMPERATURE CONTROL AND SOLAR DEVICE The fiche for packages of combination heater, temperature control and solar device shall contain the elements set out in points (a) and (b): (a) the elements set out in Figure 1 and Figure 3, respectively, for evaluating the seasonal space heating energy efficiency of a package of combination heater, temperature control and solar device, including the following information: — I: the value of the seasonal space heating energy efficiency of the preferential combination heater, expressed in %; — II: the factor for weighting the heat output of the preferential and supplementary heaters of a package as set out in Tables 5 and 6 of this Annex, respectively; — III: the value of the mathematical expression: , whereby Prated is related to the preferential combination heater; — IV: the value of the mathematical expression , whereby Prated is related to the preferential combination heater; in addition, for preferential heat pump combination heaters: — V: the value of the difference between the seasonal space heating energy efficiencies under average and colder climate conditions, expressed in %; — VI: the value of the difference between the seasonal space heating energy efficiencies under warmer and average climate conditions, expressed in %; (b) the elements set out in Figure 5 for evaluating the water heating energy efficiency of a package of combination heater, temperature control and solar device, where the following information shall be included: — I: the value of the water heating energy efficiency of the combination heater, expressed in %; — II: the value of the mathematical expression , where Q ref is taken from Table 15 in Annex VII and Q nonsol from the product fiche of the solar device for the declared load profile M, L, XL or XXL of the combination heater; — III: the value of the mathematical expression , expressed in %, where Q aux is taken from the product fiche of the solar device and Q ref from Table 15 in Annex VII for the declared load profile M, L, XL or XXL. Table 5 For the purposes of Figure 1 of this Annex, weighting of preferential boiler space heater or boiler combination heater and supplementary heater  ( *1 )  ( *2 ) II, package without hot water storage tank II, package with hot water storage tank 0 0 0 0,1 0,30 0,37 0,2 0,55 0,70 0,3 0,75 0,85 0,4 0,85 0,94 0,5 0,95 0,98 0,6 0,98 1,00 ≥ 0,7 1,00 1,00 Table 6 For the purposes of Figures 2 to 4 of this Annex, weighting of preferential cogeneration space heater, heat pump space heater, heat pump combination heater or low-temperature heat pump and supplementary heater  ( *3 )  ( *4 ) II, package without hot water storage tank II, package with hot water storage tank 0 1,00 1,00 0,1 0,70 0,63 0,2 0,45 0,30 0,3 0,25 0,15 0,4 0,15 0,06 0,5 0,05 0,02 0,6 0,02 0 ≥ 0,7 0 0 Figure 1 For preferential boiler space heaters and preferential boiler combination heaters, element of the fiche for a package of space heater, temperature control and solar device and a package of combination heater, temperature control and solar device, respectively, indicating the seasonal space heating energy efficiency of the package offered Seasonal space heating energy efficiency of boiler Temperature control From fiche of temperature control Class I = 1 %, Class II = 2 %, Class III = 1,5 %, Class IV = 2 %, Class V = 3 %, Class VI = 4 %, Class VII = 3,5 %, Class VIII = 5 % Supplementary boiler From fiche of boiler Seasonal space heating energy efficiency (in %) Solar contribution From fiche of solar device Collector size (in m 2 ) Tank volume (in m 3 ) Collector efficiency (in %) Tank rating A* = 0,95, A = 0,91, B = 0,86, C = 0,83, D-G = 0,81 Supplementary heat pump From fiche of heat pump Seasonal space heating energy efficiency (in %) Solar contribution AND Supplementary heat pump Select smaller value Seasonal space heating energy efficiency of package Seasonal space heating energy efficiency class of package Boiler and supplementary heat pump installed with low temperature heat emitters at 35 °C? From fiche of heat pump The energy efficiency of the package of products provided for in this fiche may not correspond to its actual energy efficiency once installed in a building, as the efficiency is influenced by further factors such as heat loss in the distribution system and the dimensioning of the products in relation to building size and characteristics. Figure 2 For preferential cogeneration space heaters, element of the fiche for a package of space heater, temperature control and solar device indicating the seasonal space heating energy efficiency of the package offered Seasonal space heating energy efficiency of cogeneration space heater Temperature control From fiche of temperature control Class I = 1 %, Class II = 2 %, Class III = 1,5 %, Class IV = 2 %, Class V = 3 %, Class VI = 4 %, Class VII = 3,5 %, Class VIII = 5 % Supplementary boiler From fiche of boiler Seasonal space heating energy efficiency (in %) Solar contribution From fiche of solar device Collector size (in m 2 ) Tank volume (in m 3 ) Collector efficiency (in %) Tank rating A* = 0,95, A = 0,91, B = 0,86, C = 0,83, D-G = 0,81 Seasonal space heating energy efficiency of package Seasonal space heating energy efficiency class of package The energy efficiency of the package of products provided for in this fiche may not correspond to its actual energy efficiency once installed in a building, as the efficiency is influenced by further factors such as heat loss in the distribution system and the dimensioning of the products in relation to building size and characteristics. Figure 3 For preferential heat pump space heaters and preferential heat pump combination heaters, element of the fiche for a package of space heater, temperature control and solar device and a package of combination heater, temperature control and solar device, respectively, indicating the seasonal space heating energy efficiency of the package offered Seasonal space heating energy efficiency of heat pump Temperature control From fiche of temperature control Colder: Warmer: Class I = 1 %, Class II = 2 %, Class III = 1,5 %, Class IV = 2 %, Class V = 3 %, Class VI = 4 %, Class VII = 3,5 %, Class VIII = 5 % Supplementary boiler From fiche of boiler Seasonal space heating energy efficiency (in %) Solar contribution From fiche of solar device Collector size (in m 2 ) Tank volume (in m 3 ) Collector efficiency (in %) Tank rating A* = 0,95, A = 0,91, B = 0,86, C = 0,83, D-G = 0,81 Seasonal space heating energy efficiency of package under average climate Seasonal space heating energy efficiency class of package under average climate Seasonal space heating energy efficiency under colder and warmer climate conditions The energy efficiency of the package of products provided for in this fiche may not correspond to its actual energy efficiency once installed in a building, as the efficiency is influenced by further factors such as heat loss in the distribution system and the dimensioning of the products in relation to building size and characteristics. Figure 4 For preferential low-temperature heat pumps, element of the fiche for a package of space heater, temperature control and solar device indicating the seasonal space heating energy efficiency of the package offered Seasonal space heating energy efficiency of low temperature heat pump Temperature control From fiche of temperature control Colder: Warmer: Class I = 1 %, Class II = 2 %, Class III = 1,5 %, Class IV = 2 %, Class V = 3 %, Class VI = 4 %, Class VII = 3,5 %, Class VIII = 5 % Supplementary boiler From fiche of boiler Seasonal space heating energy efficiency (in %) Solar contribution From fiche of solar device Collector size (in m 2 ) Tank volume (in m 3 ) Collector efficiency (in %) Tank rating A* = 0,95, A = 0,91, B = 0,86, C = 0,83, D-G = 0,81 Seasonal space heating energy efficiency of package under average climate Seasonal space heating energy efficiency class of package under average climate Seasonal space heating energy efficiency under colder and warmer climate conditions The energy efficiency of the package of products provided for in this fiche may not correspond to its actual energy efficiency once installed in a building, as the efficiency is influenced by further factors such as heat loss in the distribution system and the dimensioning of the products in relation to building size and characteristics. Figure 5 For preferential boiler combination heaters and preferential heat pump combination heaters, element of the fiche for a package of combination heater, temperature control and solar device indicating the water heating energy efficiency of the package offered Water heating energy efficiency of combination heater Declared load profile: Solar contribution From fiche of solar device Auxiliary electricity Water heating energy efficiency of package under average climate Water heating energy efficiency class of package under average climate Water heating energy efficiency under colder and warmer climate conditions The energy efficiency of the package of products provided for in this fiche may not correspond to its actual energy efficiency once installed in a building, as the efficiency is influenced by further factors such as heat loss in the distribution system and the dimensioning of the products in relation to building size and characteristics. Colder: Warmer: ( *1 )   The intermediate values are calculated by linear interpolation between the two adjacent values. ( *2 )    Prated is related to the preferential space heater or combination heater. ( *3 )   The intermediate values are calculated by linear interpolation between the two adjacent values. ( *4 )    Prated is related to the preferential space heater or combination heater.

Read the full instrument →

Other provisions in Commission Delegated Regulation (EU) No 811/2013

Compiled from an official source version. Later amendments or repeals may not be reflected; the official text prevails. · Read the official text ↗ · Data as of 2026-07-04

CitationANNEX IV of Commission Delegated Regulation (EU) No 811/2013 (LawPlayer, data as of 2026-07-04)

© European Union, https://eur-lex.europa.eu, 1998-2026. Reuse authorised under Commission Decision 2011/833/EU, provided the source is acknowledged.

What to look at next