ANNEX VISupplementary provisions
ANNEX VI Information to be provided in cases where end-users cannot be expected to see the product displayed 1. SPACE HEATERS 1.1. The information referred to in Article 4(1)(b) shall be provided in the following order: (a) the seasonal space heating energy efficiency class of the model, determined in accordance with point 1 of Annex II; (b) the rated heat output, including the rated heat output of any supplementary heater, in kW, rounded to the nearest integer (for heat pump space heaters, under average climate conditions); (c) the seasonal space heating energy efficiency in %, rounded to the nearest integer and calculated in accordance with points 3 and 4 of Annex VII (for heat pump space heaters, under average climate conditions); (d) the annual energy consumption in kWh in terms of final energy and/or in GJ in terms of GCV , rounded to the nearest integer and calculated in accordance with points 3 and 4 of Annex VII (for heat pump space heaters, under average climate conditions); (e) the sound power level L WA , indoors, in dB, rounded to the nearest integer (for heat pump space heaters if applicable); in addition, for cogeneration space heaters: (f) the electrical efficiency in %, rounded to the nearest integer; in addition, for heat pump space heaters: (g) the rated heat output, including the rated heat output of any supplementary heater, in kW, under colder and warmer climate conditions, rounded to the nearest integer; (h) the seasonal space heating energy efficiency in %, under colder and warmer climate conditions, rounded to the nearest integer and calculated in accordance with point 4 of Annex VII; (i) the annual energy consumption in kWh in terms of final energy and/or in GJ in terms of GCV , under colder and warmer climate conditions, rounded to the nearest integer and calculated in accordance with point 4 of Annex VII; (j) the sound power level L WA , outdoors, in dB, rounded to the nearest integer; in addition, for low-temperature heat pumps: (k) an indication that the low-temperature heat pump is only suitable for low-temperature application; 1.2. The size and font in which the information referred in point 1.1 is printed or shown shall be legible. 2. COMBINATION HEATERS 2.1. The information referred to in Article 4(2)(b) shall be provided in the following order: (a) for space heating, the medium-temperature application; for water heating, the declared load profile, expressed as the appropriate letter and typical usage in accordance with Table 15 of Annex VII; (b) the seasonal space heating energy efficiency class and the water heating energy efficiency class of the model, determined in accordance with points 1 and 2 of Annex II; (c) the rated heat output, including the rated heat output of any supplementary heater, in kW, rounded to the nearest integer (for heat pump combination heaters, under average climate conditions); (d) for space heating, the annual energy consumption in kWh in terms of final energy and/or in GJ in terms of GCV , rounded to the nearest integer and calculated in accordance with points 3 and 4 of Annex VII (for heat pump combination heaters, under average climate conditions); for water heating, the annual electricity consumption in kWh in terms of final energy and/or the annual fuel consumption in GJ in terms of GCV , rounded to the nearest integer and calculated in accordance with point 5 of Annex VII (for heat pump combination heaters, under average climate conditions); (e) the seasonal space heating energy efficiency in %, rounded to the nearest integer and calculated in accordance with points 3 and 4 of Annex VII (for heat pump combination heaters, under average climate conditions); the water heating energy efficiency in %, rounded to the nearest integer and calculated in accordance with point 5 of Annex VII (for heat pump combination heaters, under average climate conditions); (f) the sound power level L WA , indoors, in dB, rounded to the nearest integer (for heat pump combination heaters if applicable); (g) if applicable, an indication that the combination heater is able to work only during off-peak hours; in addition, for heat pump combination heaters: (h) the rated heat output, including the rated heat output of any supplementary heater, in kW, under colder and warmer climate conditions, rounded to the nearest integer; (i) for space heating, the annual energy consumption in kWh in terms of final energy and/or in GJ in terms of GCV , under colder and warmer climate conditions, rounded to the nearest integer and calculated in accordance with point 4 of Annex VII; for water heating, the annual electricity consumption in kWh in terms of final energy and/or the annual fuel consumption in GJ in terms of GCV , under colder and warmer climate conditions, rounded to the nearest integer and calculated in accordance with point 5 of Annex VII; (j) the seasonal space heating energy efficiency in %, under colder and warmer climate conditions, rounded to the nearest integer and calculated in accordance with point 4 of Annex VII; the water heating energy efficiency in %, under colder and warmer climate conditions, rounded to the nearest integer and calculated in accordance with point 5 of Annex VII; (k) the sound power level L WA , outdoors, in dB, rounded to the nearest integer. 2.2. The size and font in which the information referred in point 2.1 is printed or shown shall be legible. 3. PACKAGES OF SPACE HEATER, TEMPERATURE CONTROL AND SOLAR DEVICE 3.1. The information referred to in Article 4(3)(b) shall be provided in the following order: (a) the seasonal space heating energy efficiency class of the model, determined in accordance with point 1 of Annex II; (b) the seasonal space heating energy efficiency in %, rounded to the nearest integer; (c) the elements set out in Figure 1, Figure 2, Figure 3 and Figure 4, respectively, of Annex IV. 3.2. The size and font in which the information referred in point 3.1 is printed or shown shall be legible. 4. PACKAGES OF COMBINATION HEATER, TEMPERATURE CONTROL AND SOLAR DEVICE 4.1. The information referred to in Article 4(4)(b) shall be provided in the following order: (a) the seasonal space heating energy efficiency class and the water heating energy efficiency class of the model, determined in accordance with points 1 and 2 of Annex II; (b) the seasonal space heating energy efficiency and the water heating energy efficiency in %, rounded to the nearest integer; (c) the elements set out in Figure 1 and Figure 3, respectively, of Annex IV; (d) the elements set out in Figure 5 of Annex IV. 4.2. The size and font in which the information referred in point 4.1 is printed or shown shall be legible.