ANNEX VSupplementary provisions
ANNEX V Technical documentation 1. SPACE HEATERS For space heaters, the technical documentation referred to in Article 3(1)(c) shall include: (a) the name and address of the supplier; (b) a description of the space heater model sufficient for its unambiguous identification; (c) where appropriate, the references of the harmonised standards applied; (d) where appropriate, the other technical standards and specifications used; (e) the identification and signature of the person empowered to bind the supplier; (f) technical parameters: — for boiler space heaters and cogeneration space heaters, the technical parameters set out in Table 7, measured and calculated in accordance with Annex VII; — for heat pump space heaters, the technical parameters set out in Table 8, measured and calculated in accordance with Annex VII; — for heat pump space heaters where the information relating to a specific model comprising a combination of indoor and outdoor units has been obtained by calculation on the basis of design and/or extrapolation from other combinations, the details of such calculations and/or extrapolations, and of any tests undertaken to verify the accuracy of the calculations, including details of the mathematical model for calculating the performance of such combinations and details of the measurements taken to verify this model; (g) any specific precautions that shall be taken when the space heater is assembled, installed or maintained. 2. COMBINATION HEATERS For combination heaters, the technical documentation referred to in Article 3(2)(c) shall include: (a) the name and address of the supplier; (b) a description of the combination heater model sufficient for its unambiguous identification; (c) where appropriate, the references of the harmonised standards applied; (d) where appropriate, the other technical standards and specifications used; (e) the identification and signature of the person empowered to bind the supplier; (f) technical parameters: — for boiler combination heaters, the technical parameters set out in Table 7, measured and calculated in accordance with Annex VII; — for heat pump combination heaters, the technical parameters set out in Table 8, measured and calculated in accordance with Annex VII; — for heat pump combination heaters where the information relating to a specific model comprising a combination of indoor and outdoor units has been obtained by calculation on the basis of design and/or extrapolation from other combinations, the details of such calculations and/or extrapolations, and of any tests undertaken to verify the accuracy of the calculations, including details of the mathematical model for calculating the performance of such combinations and details of the measurements taken to verify this model; (g) any specific precautions that shall be taken when the combination heater is assembled, installed or maintained. Table 7 Technical parameters for boiler space heaters, boiler combination heaters and cogeneration space heaters Model(s): [information identifying the model(s) to which the information relates] Condensing boiler: [yes/no] Low-temperature ( *2 ) boiler: [yes/no] B11 boiler: [yes/no] Cogeneration space heater: [yes/no] If yes, equipped with a supplementary heater: [yes/no] Combination heater: [yes/no] Item Symbol Value Unit Item Symbol Value Unit Rated heat output Prated x kW Seasonal space heating energy efficiency η s x % For boiler space heaters and boiler combination heaters: Useful heat output For boiler space heaters and boiler combination heaters: Useful efficiency At rated heat output and high-temperature regime ( *1 ) P 4 x,x kW At rated heat output and high-temperature regime ( *1 ) η 4 x,x % At 30 % of rated heat output and low-temperature regime ( *2 ) P 1 x,x kW At 30 % of rated heat output and low-temperature regime ( *2 ) η 1 x,x % For cogeneration space heaters: Useful heat output For cogeneration space heaters: Useful efficiency At rated heat output of cogeneration space heater with supplementary heater disabled P CHP100+Sup0 x,x kW At rated heat output of cogeneration space heater with supplementary heater disabled η CHP100+Sup0 x,x % At rated heat output of cogeneration space heater with supplementary heater enabled P CHP100+Sup100 x,x kW At rated heat output of cogeneration space heater with supplementary heater enabled η CHP100+Sup100 x,x % For cogeneration space heaters: Electrical efficiency Supplementary heater At rated heat output of cogeneration space heater with supplementary heater disabled η el,CHP100+Sup0 x,x % Rated heat output Psup x,x kW At rated heat output of cogeneration space heater with supplementary heater enabled η el,CHP100+Sup100 x,x % Type of energy input Auxiliary electricity consumption Other items At full load elmax x,x kW Standby heat loss P stby x,x kW At part load elmin x,x kW Ignition burner power consumption P ign x,x kW In standby mode P SB x,xxx kW Annual energy consumption Q HE x kWh or GJ Sound power level, indoors L WA x dB For combination heaters: Declared load profile Water heating energy efficiency η wh x % Daily electricity consumption Q elec x,xxx kWh Daily fuel consumption Q fuel x,xxx kWh Annual electricity consumption AEC x kWh Annual fuel consumption AFC x GJ Contact details Name and address of the supplier. Table 8 Technical parameters for heat pump space heaters and heat pump combination heaters Model(s): [information identifying the model(s) to which the information relates] Air-to-water heat pump: [yes/no] Water-to-water heat pump: [yes/no] Brine-to-water heat pump: [yes/no] Low-temperature heat pump: [yes/no] Equipped with a supplementary heater: [yes/no] Heat pump combination heater: [yes/no] Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pumps, parameters shall be declared for low-temperature application. Parameters shall be declared for average, colder and warmer climate conditions. Item Symbol Value Unit Item Symbol Value Unit Rated heat output ( *3 ) Prated x kW Seasonal space heating energy efficiency η s x % Declared capacity for heating for part load at indoor temperature 20 °C and outdoor temperature T j Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20 °C and outdoor temperature T j T j = – 7 °C Pdh x,x kW T j = – 7 °C COPd or PERd x,xx or x,x – or % T j = + 2 °C Pdh x,x kW T j = + 2 °C COPd or PERd x,xx or x,x – or % T j = + 7 °C Pdh x,x kW T j = + 7 °C COPd or PERd x,xx or x,x – or % T j = + 12 °C Pdh x,x kW T j = + 12 °C COPd or PERd x,xx or x,x – or % T j = bivalent temperature Pdh x,x kW T j = bivalent temperature COPd or PERd x,xx or x,x – or % T j = operation limit temperature Pdh x,x kW T j = operation limit temperature COPd or PERd x,xx or x,x – or % For air-to-water heat pumps: T j = – 15 °C (if TOL < – 20 °C) Pdh x,x kW For air-to-water heat pumps: T j = – 15 °C (if TOL < – 20 °C) COPd or PERd x,xx or x,x – or % Bivalent temperature T biv x °C For air-to-water heat pumps: Operation limit temperature TOL x °C Cycling interval capacity for heating Pcych x,x kW Cycling interval efficiency COPcyc or PERcyc x,xx or x,x – or % Degradation co-efficient ( *4 ) Cdh x,x — Heating water operating limit temperature WTOL x °C Power consumption in modes other than active mode Supplementary heater Off mode P OFF x,xxx kW Rated heat output ( *4 ) Psup x,x kW Thermostat-off mode P TO x,xxx kW Standby mode P SB x,xxx kW Type of energy input Crankcase heater mode P CK x,xxx kW Other items Capacity control fixed/variable For air-to-water heat pumps: Rated air flow rate, outdoors — x m 3 /h Sound power level, indoors/outdoors L WA x / x dB For water- or brine-to-water heat pumps: Rated brine or water flow rate, outdoor heat exchanger — x m 3 /h Annual energy consumption Q HE x kWh or GJ For heat pump combination heater: Declared load profile x Water heating energy efficiency η wh x % Daily electricity consumption Q elec x,xxx kWh Daily fuel consumption Q fuel x,xxx kWh Annual electricity consumption AEC x kWh Annual fuel consumption AFC x GJ Contact details Name and address of the supplier. 3. TEMPERATURE CONTROLS For temperature controls, the technical documentation referred to in Article 3(3)(b) shall include: (a) the name and address of the supplier; (b) a description of the temperature control model sufficient for its unambiguous identification; (c) where appropriate, the references of the harmonised standards applied; (d) where appropriate, the other technical standards and specifications used; (e) the identification and signature of the person empowered to bind the supplier; (f) technical parameters: — the class of the temperature control; — the contribution of the temperature control to seasonal space heating energy efficiency in %, rounded to one decimal place; (g) any specific precautions that shall be taken when the temperature control is assembled, installed or maintained. 4. SOLAR DEVICES For solar devices, the technical documentation referred to in Article 3(4)(b) shall include: (a) the name and address of the supplier; (b) a description of the solar device model sufficient for its unambiguous identification; (c) where appropriate, the references of the harmonised standards applied; (d) where appropriate, the other technical standards and specifications used; (e) the identification and signature of the person empowered to bind the supplier; (f) technical parameters (for pumps in the collector loop if applicable): — the collector aperture area A sol in m 2 , to two decimal places; — the collector efficiency η col in %, rounded to the nearest integer; — the energy efficiency class of the solar hot water storage tank, determined in accordance with point 3 of Annex II; — the standing loss S of the solar hot water storage tank in W, rounded to the nearest integer; — the storage volume V of the solar hot water storage tank in litres and m 3 ; — the annual non-solar heat contribution Q nonsol in kWh in terms of primary energy for electricity and/or in kWh in terms of GCV for fuels, for the load profiles M, L, XL and XXL under average climate conditions, rounded to the nearest integer; — the pump power consumption solpump in W, rounded to the nearest integer; — the standby power consumption solstandby in W, to two decimal places; — the annual auxiliary electricity consumption Q aux in kWh in terms of final energy, rounded to the nearest integer; (g) any specific precautions that shall be taken when the solar device is assembled, installed or maintained. 5. PACKAGES OF SPACE HEATER, TEMPERATURE CONTROL AND SOLAR DEVICE For packages of space heater, temperature control and solar device, the technical documentation referred to in Article 3(5)(c) shall include: (a) the name and address of the supplier; (b) a description of the package of space heater, temperature control and solar device model sufficient for its unambiguous identification; (c) where appropriate, the references of the harmonised standards applied; (d) where appropriate, the other technical standards and specifications used; (e) the identification and signature of the person empowered to bind the supplier; (f) technical parameters: — the seasonal space heating energy efficiency in %, rounded to the nearest integer; — the technical parameters set out in points 1, 3 and 4 of this Annex; (g) any specific precautions that shall be taken when the package of space heater, temperature control and solar device is assembled, installed or maintained. 6. PACKAGES OF COMBINATION HEATER, TEMPERATURE CONTROL AND SOLAR DEVICE For packages of combination heater, temperature control and solar device, the technical documentation referred to in Article 3(6)(c) shall include: (a) the name and address of the supplier; (b) a description of the package of combination heater, temperature control and solar device model sufficient for its unambiguous identification; (c) where appropriate, the references of the harmonised standards applied; (d) where appropriate, the other technical standards and specifications used; (e) the identification and signature of the person empowered to bind the supplier; (f) technical parameters: — the seasonal space heating energy efficiency and water heating energy efficiency in %, rounded to the nearest integer; — the technical parameters set out in points 2, 3 and 4 of this Annex; (g) any specific precautions that shall be taken when the package of combination heater, temperature control and solar device is assembled, installed or maintained. ( *1 ) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet. ( *2 ) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet). ( *3 ) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh , and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj) . ( *4 ) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.