The Measuring Instruments Regulations 2016

The Measuring Instruments Regulations 2016 Sch 1J para 8

Sch 1J para 8 Other requirements

For measuring CO, CO 2 and HC, the instrument, including the specified gas handling system, must indicate 95 % of the final value as determined with calibration gases within 15 seconds after changing from a gas with zero content, e.g. fresh air. For measuring O 2 , the instrument under similar conditions must indicate a value differing less than 0.1 % vol from zero within 60 seconds after changing from fresh air to an oxygen-free gas.