§ 60.1Applicability.

(a) Except as provided in subparts B, Ba, and C of this part, the provisions of this part apply to the owner or operator of any stationary source which contains an affected facility, the construction or modification of which is commenced after the date of publication in this part of any standard (or, if earlier, the date of publication of any proposed standard) applicable to that facility.

(b) Any new or revised standard of performance promulgated pursuant to section 111(b) of the Act shall apply to the owner or operator of any stationary source which contains an affected facility, the construction or modification of which is commenced after the date of publication in this part of such new or revised standard (or, if earlier, the date of publication of any proposed standard) applicable to that facility.

(c) In addition to complying with the provisions of this part, the owner or operator of an affected facility may be required to obtain an operating permit issued to stationary sources by an authorized State air pollution control agency or by the Administrator of the U.S. Environmental Protection Agency (EPA) pursuant to Title V of the Clean Air Act (Act) as amended November 15, 1990 (42 U.S.C. 7661). For more information about obtaining an operating permit see part 70 of this chapter.

(d) Site-specific standard for Merck & Co., Inc.'s Stonewall Plant in Elkton, Virginia. (1) This paragraph applies only to the pharmaceutical manufacturing facility, commonly referred to as the Stonewall Plant, located at Route 340 South, in Elkton, Virginia (“site”).

(2) Except for compliance with 40 CFR 60.49b(u), the site shall have the option of either complying directly with the requirements of this part, or reducing the site-wide emissions caps in accordance with the procedures set forth in a permit issued pursuant to 40 CFR 52.2454. If the site chooses the option of reducing the site-wide emissions caps in accordance with the procedures set forth in such permit, the requirements of such permit shall apply in lieu of the otherwise applicable requirements of this part.

(3) Notwithstanding the provisions of paragraph (d)(2) of this section, for any provisions of this part except for Subpart Kb, the owner/operator of the site shall comply with the applicable provisions of this part if the Administrator determines that compliance with the provisions of this part is necessary for achieving the objectives of the regulation and the Administrator notifies the site in accordance with the provisions of the permit issued pursuant to 40 CFR 52.2454.

§ 60.2Definitions.

The terms used in this part are defined in the Act or in this section as follows:

Act means the Clean Air Act (42 U.S.C. 7401 et seq. )

Administrator means the Administrator of the Environmental Protection Agency or his authorized representative.

Affected facility means, with reference to a stationary source, any apparatus to which a standard is applicable.

Alternative method means any method of sampling and analyzing for an air pollutant which is not a reference or equivalent method but which has been demonstrated to the Administrator's satisfaction to, in specific cases, produce results adequate for his determination of compliance.

Approved permit program means a State permit program approved by the Administrator as meeting the requirements of part 70 of this chapter or a Federal permit program established in this chapter pursuant to Title V of the Act (42 U.S.C. 7661).

Capital expenditure means an expenditure for a physical or operational change to an existing facility which exceeds the product of the applicable “annual asset guideline repair allowance percentage” specified in the latest edition of Internal Revenue Service (IRS) Publication 534 and the existing facility's basis, as defined by section 1012 of the Internal Revenue Code. However, the total expenditure for a physical or operational change to an existing facility must not be reduced by any “excluded additions” as defined in IRS Publication 534, as would be done for tax purposes.

Clean coal technology demonstration project means a project using funds appropriated under the heading ‘Department of Energy-Clean Coal Technology’, up to a total amount of $2,500,000,000 for commercial demonstrations of clean coal technology, or similar projects funded through appropriations for the Environmental Protection Agency.

Commenced means, with respect to the definition of new source in section 111(a)(2) of the Act, that an owner or operator has undertaken a continuous program of construction or modification or that an owner or operator has entered into a contractual obligation to undertake and complete, within a reasonable time, a continuous program of construction or modification.

Construction means fabrication, erection, or installation of an affected facility.

Continuous monitoring system means the total equipment, required under the emission monitoring sections in applicable subparts, used to sample and condition (if applicable), to analyze, and to provide a permanent record of emissions or process parameters.

Electric utility steam generating unit means any steam electric generating unit that is constructed for the purpose of supplying more than one-third of its potential electric output capacity and more than 25 MW electrical output to any utility power distribution system for sale. Any steam supplied to a steam distribution system for the purpose of providing steam to a steam-electric generator that would produce electrical energy for sale is also considered in determining the electrical energy output capacity of the affected facility.

Equivalent method means any method of sampling and analyzing for an air pollutant which has been demonstrated to the Administrator's satisfaction to have a consistent and quantitatively known relationship to the reference method, under specified conditions.

Excess Emissions and Monitoring Systems Performance Report is a report that must be submitted periodically by a source in order to provide data on its compliance with stated emission limits and operating parameters, and on the performance of its monitoring systems.

Existing facility means, with reference to a stationary source, any apparatus of the type for which a standard is promulgated in this part, and the construction or modification of which was commenced before the date of proposal of that standard; or any apparatus which could be altered in such a way as to be of that type.

Force majeure means, for purposes of § 60.8, an event that will be or has been caused by circumstances beyond the control of the affected facility, its contractors, or any entity controlled by the affected facility that prevents the owner or operator from complying with the regulatory requirement to conduct performance tests within the specified timeframe despite the affected facility's best efforts to fulfill the obligation. Examples of such events are acts of nature, acts of war or terrorism, or equipment failure or safety hazard beyond the control of the affected facility.

Isokinetic sampling means sampling in which the linear velocity of the gas entering the sampling nozzle is equal to that of the undisturbed gas stream at the sample point.

Issuance of a part 70 permit will occur, if the State is the permitting authority, in accordance with the requirements of part 70 of this chapter and the applicable, approved State permit program. When the EPA is the permitting authority, issuance of a Title V permit occurs immediately after the EPA takes final action on the final permit.

Malfunction means any sudden, infrequent, and not reasonably preventable failure of air pollution control equipment, process equipment, or a process to operate in a normal or usual manner. Failures that are caused in part by poor maintenance or careless operation are not malfunctions.

Modification means any physical change in, or change in the method of operation of, an existing facility which increases the amount of any air pollutant (to which a standard applies) emitted into the atmosphere by that facility or which results in the emission of any air pollutant (to which a standard applies) into the atmosphere not previously emitted.

Monitoring device means the total equipment, required under the monitoring of operations sections in applicable subparts, used to measure and record (if applicable) process parameters.

Nitrogen oxides means all oxides of nitrogen except nitrous oxide, as measured by test methods set forth in this part.

One-hour period means any 60-minute period commencing on the hour.

Opacity means the degree to which emissions reduce the transmission of light and obscure the view of an object in the background.

Owner or operator means any person who owns, leases, operates, controls, or supervises an affected facility or a stationary source of which an affected facility is a part.

Part 70 permit means any permit issued, renewed, or revised pursuant to part 70 of this chapter.

Particulate matter means any finely divided solid or liquid material, other than uncombined water, as measured by the reference methods specified under each applicable subpart, or an equivalent or alternative method.

Permit program means a comprehensive State operating permit system established pursuant to title V of the Act (42 U.S.C. 7661) and regulations codified in part 70 of this chapter and applicable State regulations, or a comprehensive Federal operating permit system established pursuant to title V of the Act and regulations codified in this chapter.

Permitting authority means:

(1) The State air pollution control agency, local agency, other State agency, or other agency authorized by the Administrator to carry out a permit program under part 70 of this chapter; or

(2) The Administrator, in the case of EPA-implemented permit programs under title V of the Act (42 U.S.C. 7661).

Proportional sampling means sampling at a rate that produces a constant ratio of sampling rate to stack gas flow rate.

Reactivation of a very clean coal-fired electric utility steam generating unit means any physical change or change in the method of operation associated with the commencement of commercial operations by a coal-fired utility unit after a period of discontinued operation where the unit:

(1) Has not been in operation for the two-year period prior to the enactment of the Clean Air Act Amendments of 1990, and the emissions from such unit continue to be carried in the permitting authority's emissions inventory at the time of enactment;

(2) Was equipped prior to shut-down with a continuous system of emissions control that achieves a removal efficiency for sulfur dioxide of no less than 85 percent and a removal efficiency for particulates of no less than 98 percent;

(3) Is equipped with low-NO X burners prior to the time of commencement of operations following reactivation; and

(4) Is otherwise in compliance with the requirements of the Clean Air Act.

Reference method means any method of sampling and analyzing for an air pollutant as specified in the applicable subpart.

Repowering means replacement of an existing coal-fired boiler with one of the following clean coal technologies: atmospheric or pressurized fluidized bed combustion, integrated gasification combined cycle, magnetohydrodynamics, direct and indirect coal-fired turbines, integrated gasification fuel cells, or as determined by the Administrator, in consultation with the Secretary of Energy, a derivative of one or more of these technologies, and any other technology capable of controlling multiple combustion emissions simultaneously with improved boiler or generation efficiency and with significantly greater waste reduction relative to the performance of technology in widespread commercial use as of November 15, 1990. Repowering shall also include any oil and/or gas-fired unit which has been awarded clean coal technology demonstration funding as of January 1, 1991, by the Department of Energy.

Run means the net period of time during which an emission sample is collected. Unless otherwise specified, a run may be either intermittent or continuous within the limits of good engineering practice.

Shutdown means the cessation of operation of an affected facility for any purpose.

Six-minute period means any one of the 10 equal parts of a one-hour period.

Standard means a standard of performance proposed or promulgated under this part.

Standard conditions means a temperature of 293 K (68F) and a pressure of 101.3 kilopascals (29.92 in Hg).

Startup means the setting in operation of an affected facility for any purpose.

State means all non-Federal authorities, including local agencies, interstate associations, and State-wide programs, that have delegated authority to implement: (1) The provisions of this part; and/or (2) the permit program established under part 70 of this chapter. The term State shall have its conventional meaning where clear from the context.

Stationary source means any building, structure, facility, or installation which emits or may emit any air pollutant.

Title V permit means any permit issued, renewed, or revised pursuant to Federal or State regulations established to implement title V of the Act (42 U.S.C. 7661). A title V permit issued by a State permitting authority is called a part 70 permit in this part.

Volatile Organic Compound means any organic compound which participates in atmospheric photochemical reactions; or which is measured by a reference method, an equivalent method, an alternative method, or which is determined by procedures specified under any subpart.

§ 60.3Units and abbreviations.

Used in this part are abbreviations and symbols of units of measure. These are defined as follows:

(a) System International (SI) units of measure:

A—ampere

g—gram

Hz—hertz

J—joule

K—degree Kelvin

kg—kilogram

m—meter

m

3 —cubic meter

mg—milligram—10 −3 gram

mm—millimeter—10 −3 meter

Mg—megagram—10

6 gram

mol—mole

N—newton

ng—nanogram—10 −9 gram

nm—nanometer—10 −9 meter

Pa—pascal

s—second

V—volt

W—watt

Ω—ohm

µg—microgram—10 −6 gram

(b) Other units of measure:

Btu—British thermal unit

°C—degree Celsius (centigrade)

cal—calorie

cfm—cubic feet per minute

cu ft—cubic feet

dcf—dry cubic feet

dcm—dry cubic meter

dscf—dry cubic feet at standard conditions

dscm—dry cubic meter at standard conditions

eq—equivalent

°F—degree Fahrenheit

ft—feet

gal—gallon

gr—grain

g-eq—gram equivalent

hr—hour

in—inch

k—1,000

l—liter

lpm—liter per minute

lb—pound

meq—milliequivalent

min—minute

ml—milliliter

mol. wt.—molecular weight

ppb—parts per billion

ppm—parts per million

psia—pounds per square inch absolute

psig—pounds per square inch gage

°R—degree Rankine

scf—cubic feet at standard conditions

scfh—cubic feet per hour at standard conditions

scm—cubic meter at standard conditions

sec—second

sq ft—square feet

std—at standard conditions

(c) Chemical nomenclature:

CdS—cadmium sulfide

CO—carbon monoxide

CO 2 —carbon dioxide

HCl—hydrochloric acid

Hg—mercury

H 2 O—water

H 2 S—hydrogen sulfide

H 2 SO 4 —sulfuric acid

N 2 —nitrogen

NO—nitric oxide

NO 2 —nitrogen dioxide

NO X —nitrogen oxides

O 2 —oxygen

SO 2 —sulfur dioxide

SO 3 —sulfur trioxide

SO X —sulfur oxides

(d) Miscellaneous:

A.S.T.M.—American Society for Testing and Materials

§ 60.4Address.

(a) All requests, reports, applications, submittals, and other communications to the Administrator pursuant to this part shall be submitted in duplicate to the appropriate Regional Office of the U.S. Environmental Protection Agency to the attention of the Director of the Division indicated in the following table.

Table 1 to Paragraph ( a )

Region

Address

State

I

Director, Enforcement and Compliance Assurance Division, U.S. EPA Region I, 5 Post Office Square—Suite 100 (04-2), Boston, MA 02109-3912, Attn: Air Compliance Clerk

Connecticut, Maine, Massachusetts, New Hampshire, Rhode Island, Vermont.

II

Director, Air and Waste Management Division, U.S. Environmental Protection Agency, Federal Office Building, 26 Federal Plaza (Foley Square), New York, NY 10278

New Jersey, New York, Puerto Rico, Virgin Islands.

III

Director, Air Protection Division, Mail Code 3AP00, 1650 Arch Street, Philadelphia, PA 19103-2029

Delaware, District of Columbia, Maryland, Pennsylvania, Virginia, West Virginia.

IV

Director, Air and Radiation Division, 61 Forsyth Street SW, Atlanta, Georgia 30303-8960

Alabama, Florida, Georgia, Kentucky, Mississippi, North Carolina, South Carolina, Tennessee.

V

Director, Air and Radiation Division, U.S. Environmental Protection Agency, 77 West Jackson Boulevard, Chicago, IL 60604-3590

Illinois, Indiana, Michigan, Minnesota, Ohio, Wisconsin.

VI

Director; Enforcement and Compliance Assurance Division; U.S. Environmental Protection Agency, 1201 Elm Street, Suite 500, Mail Code 6ECD, Dallas, Texas 75270-2102

Arkansas, Louisiana, New Mexico, Oklahoma, Texas.

VII

Director, Air and Waste Management Division, 11201 Renner Boulevard, Lenexa, Kansas 66219

Iowa, Kansas, Missouri, Nebraska.

VIII

Director, Air and Toxics Technical Enforcement Program, Office of Enforcement, Compliance and Environmental Justice, Mail Code 8ENF-AT, 1595 Wynkoop Street, Denver, CO 80202-1129

Colorado, Montana, North Dakota, South Dakota, Utah, Wyoming.

IX

Director, Enforcement and Compliance Assurance Division (ENF 2-1), U.S. Environmental Protection Agency Region IX, 75 Hawthorne Street, San Francisco, CA 94105

Arizona, California, Hawaii and Nevada; the territories of American Samoa and Guam; the Commonwealth of the Northern Mariana Islands; the territories of Baker Island, Howland Island, Jarvis Island, Johnston Atoll, Kingman Reef, Midway Atoll, Palmyra Atoll, and Wake Islands; and certain U.S. Government activities in the freely associated states of the Republic of the Marshall Islands, the Federated States of Micronesia, and the Republic of Palau.

X

Director, Air and Waste Management Division, U.S. Environmental Protection Agency, 1200 Sixth Avenue, Seattle, WA 98101

Alaska, Oregon, Idaho, Washington.

(b) Section 111(c) directs the Administrator to delegate to each State, when appropriate, the authority to implement and enforce standards of performance for new stationary sources located in such State. All information required to be submitted to EPA under paragraph (a) of this section, must also be submitted to the appropriate State Agency of any State to which this authority has been delegated (provided, that each specific delegation may except sources from a certain Federal or State reporting requirement). The appropriate mailing address for those States whose delegation request has been approved is as follows:

(1) [Reserved]

(2) State of Alabama: Alabama Department of Environmental Management, P.O. Box 301463, Montgomery, Alabama 36130-1463.

(3) State of Alaska, Department of Environmental Conservation, Pouch O, Juneau, AK 99811.

(4) Arizona:

Arizona Department of Environmental Quality, Suite #160, 1110 West Washington Street, Phoenix, AZ 85007.

Maricopa County Air Quality Department, 301 West Jefferson Street, Phoenix, AZ 85003.

Pima County Department of Environmental Quality, 33 North Stone Avenue, Suite 700, Tucson, AZ 85701.

Pinal County Air Quality Department, 31 North Pinal Street, Building F, Florence, AZ 85132.

Note 1 to paragraph ( b )(4):

For tables listing the delegation status of agencies in Region IX, see paragraph (d) of this section.

(5) State of Arkansas: Chief, Division of Air Pollution Control, Arkansas Department of Pollution Control and Ecology, 8001 National Drive, P.O. Box 9583, Little Rock, AR 72209.

(6) California:

Amador Air District, 810 Court Street, Jackson, CA 95642.

Antelope Valley Air Quality Management District, 2551 W Avenue H, Lancaster, CA 93536.

Bay Area Air Quality Management District, 375 Beale Street, Suite 600, San Francisco, CA 94105.

Butte County Air Quality Management District, 629 Entler Avenue, Suite 15, Chico, CA 95928.

Calaveras County Air Pollution Control District, 891 Mountain Ranch Road, Building E, San Andreas, CA 95249.

Colusa County Air Pollution Control District, 100 Sunrise Blvd., Suite A, Colusa, CA 95932-3246.

El Dorado County Air Quality Management District, 330 Fair Lane, Placerville, CA 95667-4100.

Eastern Kern Air Pollution Control District, 2700 “M” Street, Suite 302, Bakersfield, CA 93301-2370.

Feather River Air Quality Management District, 541 Washington Avenue, Yuba City, CA 95991.

Glenn County Air Pollution Control District, 720 N Colusa Street, P.O. Box 351, Willows, CA 95988-0351.

Great Basin Unified Air Pollution Control District, 157 Short Street, Bishop, CA 93514-3537.

Imperial County Air Pollution Control District, 150 South Ninth Street, El Centro, CA 92243-2839.

Lake County Air Quality Management District, 2617 S Main St., Lakeport, CA 95453-5405.

Lassen County Air Pollution Control District, 720 South St., Susanville, CA 96130.

Mariposa County Air Pollution Control District, P.O. Box 5, Mariposa, CA 95338.

Mendocino County Air Quality Management District, 306 E Gobbi Street, Ukiah, CA 95482-5511.

Modoc County Air Pollution Control District, 202 W 4th Street, Alturas, CA 96101.

Mojave Desert Air Quality Management District, 14306 Park Avenue, Victorville, CA 92392-2310.

Monterey Bay Air Resources District, 24580 Silver Cloud Court, Monterey, CA 93940.

North Coast Unified Air Quality Management District, 707 L Street, Eureka, CA 95501-3327.

Northern Sierra Air Quality Management District, 200 Litton Drive, Suite 320, Grass Valley, CA 95945-2509.

Northern Sonoma County Air Pollution Control District, 150 Matheson Street, Healdsburg, CA 95448-4908.

Placer County Air Pollution Control District, 110 Maple Street, Auburn, CA 95603.

Sacramento Metropolitan Air Quality Management District, 777 12th Street, Suite 300, Sacramento, CA 95814-1908.

San Diego County Air Pollution Control District, 10124 Old Grove Road, San Diego, CA 92131-1649.

San Joaquin Valley Air Pollution Control District, 1990 E Gettysburg, Fresno, CA 93726.

San Luis Obispo County Air Pollution Control District, 3433 Roberto Court, San Luis Obispo, CA 93401-7126.

Santa Barbara County Air Pollution Control District, 260 North San Antonio Road, Suite A, Santa Barbara, CA 93110-1315.

Shasta County Air Quality Management District, 1855 Placer Street, Suite 101, Redding, CA 96001-1759.

Siskiyou County Air Pollution Control District, 525 So. Foothill Drive, Yreka, CA 96097-3036.

South Coast Air Quality Management District, 21865 Copley Drive, Diamond Bar, CA 91765-4182.

Tehama County Air Pollution Control District, P.O. Box 1169 (1834 Walnut Street), Red Bluff, CA 96080-0038.

Tuolumne County Air Pollution Control District, 2 South Green St., Sonora, CA 95370-4618.

Ventura County Air Pollution Control District, 4567 Telephone Road, 2nd Floor, Ventura, CA 93003-5417.

Yolo-Solano Air Quality Management District, 1947 Galileo Court, Suite 103, Davis, CA 95618.

Note 2 to paragraph ( b )(6):

For tables listing the delegation status of agencies in Region IX, see paragraph (d) of this section.

(7) State of Colorado, Department of Public Health and Environment, 4300 Cherry Creek Drive South, Denver, CO 80222-1530.

Note:

For a table listing Region VIII's NSPS delegation status, see paragraph (c) of this section.

(8) State of Connecticut, Compliance Analysis and Coordination Unit, Bureau of Air Management, Department of Energy and Environmental Protection, 79 Elm Street, 5th Floor, Hartford, CT 06106-5127.

(9) State of Delaware, Department of Natural Resources & Environmental Control, 89 Kings Highway, P.O. Box 1401, Dover, Delaware 19903.

(10) District of Columbia, Department of Public Health, Air Quality Division, 51 N Street, NE., Washington, DC 20002.

(11) State of Florida: Florida Department of Environmental Protection, Division of Air Resources Management, 2600 Blair Stone Road, MS 5500, Tallahassee, Florida 32399-2400.

(12) State of Georgia: Georgia Department of Natural Resources, Environmental Protection Division, Air Protection Branch, 4244 International Parkway, Suite 120, Atlanta, Georgia 30354.

(13) Hawaii:

Clean Air Branch, Hawaii Department of Health, 2827 Waimano Home Road, #130 Pearl City, HI 96782.

Note 4 to paragraph ( b )(13):

For tables listing the delegation status of agencies in Region IX, see paragraph (d) of this section.

(14) State of Idaho, Department of Health and Welfare, Statehouse, Boise, ID 83701.

(15) State of Illinois: Illinois Environmental Protection Agency, 1021 North Grand Avenue East, Springfield, Illinois 62794.

(16) State of Indiana: Indiana Department of Environmental Management, Office of Air Quality, 100 North Senate Avenue, Indianapolis, Indiana 46204.

(17) State of Iowa: Iowa Department of Natural Resources, Environmental Protection Division, Air Quality Bureau, 7900 Hickman Road, Suite 1, Urbandale, IA 50322.

(18) State of Kansas: Kansas Department of Health and Environment, Bureau of Air and Radiation, 1000 S.W. Jackson, Suite 310, Topeka, KS 66612-1366.

(19) Commonwealth of Kentucky: Kentucky Department for Environmental Protection, Division for Air Quality, 300 Sower Boulevard, 2nd Floor, Frankfort, Kentucky 40601 or local agency, Louisville Metro Air Pollution Control District, 701 W. Ormsby Ave., Suite 303, Louisville, Kentucky 40203.

(20) State of Louisiana: Louisiana Department of Environmental Quality, P.O. Box 4301, Baton Rouge, Louisiana 70821-4301.

Note:

For a list of delegated standards for Louisiana (excluding Indian country), see paragraph (e)(2) of this section.

(21) State of Maine, Maine Department of Environmental Protection, Bureau of Air Quality, 17 State House Station, Augusta, ME 04333-0017.

(22) State of Maryland, Department of the Environment, 1800 Washington Boulevard, Suite 705, Baltimore, Maryland 21230.

(23) Commonwealth of Massachusetts, Massachusetts Department of Environmental Protection, Division of Air and Climate Programs, One Winter Street, Boston, MA 02108.

(24) State of Michigan: Michigan Department of Natural Resources and Environment, Air Quality Division, P.O. Box 30028, Lansing, Michigan 48909.

(25) State of Minnesota: Minnesota Pollution Control Agency, Division of Air Quality, 520 Lafayette Road North, St. Paul, Minnesota 55155.

(26) State of Mississippi: Hand Deliver or Courier: Mississippi Department of Environmental Quality, Office of Pollution Control, Air Division, 515 East Amite Street, Jackson, Mississippi 39201, Mailing Address: Mississippi Department of Environmental Quality, Office of Pollution Control, Air Division, P.O. Box 2261, Jackson, Mississippi 39225.

(27) State of Missouri: Missouri Department of Natural Resources, Division of Environmental Quality, P.O. Box 176, Jefferson City, MO 65102.

(28) State of Montana, Department of Environmental Quality, 1520 E. 6th Ave., PO Box 200901, Helena, MT 59620-0901.

Note:

For a table listing Region VIII's NSPS delegation status, see paragraph (c) of this section.

(29) State of Nebraska, Nebraska Department of Environmental Control, P.O. Box 94877, State House Station, Lincoln, NE 68509.

Lincoln-Lancaster County Health Department, Division of Environmental Health, 2200 St. Marys Avenue, Lincoln, NE 68502

(30) Nevada:

Nevada Division of Environmental Protection, 901 South Stewart Street, Suite 4001, Carson City, NV 89701-5249.

Clark County Division of Air Quality, 500 S Grand Central Parkway, 1st Floor, P.O. Box 555210, Las Vegas, NV 89155-5210.

Northern Nevada Public Health, Air Quality Management Division, 1001 E 9th Street, Building B, Reno, NV 89512.

Note 7 to paragraph ( b )(30):

For tables listing the delegation status of agencies in Region IX, see paragraph (d) of this section.

(31) State of New Hampshire, New Hampshire Department of Environmental Services, Air Resources Division, 29 Hazen Drive, P.O. Box 95, Concord, NH 03302-0095.

(32) State of New Jersey: New Jersey Department of Environmental Protection, Division of Environmental Quality, Enforcement Element, John Fitch Plaza, CN-027, Trenton, NJ 08625.

(1) The following table lists the specific source and pollutant categories that have been delegated to the states in Region II. The (X) symbol is used to indicate each category that has been delegated.

Subpart

State

New Jersey

New York

Puerto Rico

Virgin Islands

D

Fossil-Fuel Fired Steam Generators for Which Construction Commenced After August 17, 1971 (Steam Generators and Lignite Fired Steam Generators)

X

X

X

X

Da

Electric Utility Steam Generating Units for Which Construction Commenced After September 18, 1978

X

X

Db

Industrial-Commercial-Institutional Steam Generating Units

X

X

X

X

E

Incinerators

X

X

X

X

F

Portland Cement Plants

X

X

X

X

G

Nitric Acid Plants

X

X

X

X

H

Sulfuric Acid Plants

X

X

X

X

I

Asphalt Concrete Plants

X

X

X

X

J

Petroleum Refineries—(All Categories)

X

X

X

X

K

Storage Vessels for Petroleum Liquids Constructed After June 11, 1973, and prior to May 19, 1978

X

X

X

X

Ka

Storage Vessels for Petroleum Liquids Constructed After May 18, 1978

X

X

X

L

Secondary Lead Smelters

X

X

X

X

M

Secondary Brass and Bronze Ingot Production Plants

X

X

X

X

N

Iron and Steel Plants

X

X

X

X

O

Sewage Treatment Plants

X

X

X

X

P

Primary Copper Smelters

X

X

X

X

Q

Primary Zinc Smelters

X

X

X

X

R

Primary Lead Smelters

X

X

X

X

S

Primary Aluminum Reduction Plants

X

X

X

X

T

Phosphate Fertilizer Industry: Wet Process Phosphoric Acid Plants

X

X

X

X

U

Phosphate Fertilizer Industry: Superphosphoric Acid Plants

X

X

X

X

V

Phosphate Fertilizer Industry: Diammonium Phosphate Plants

X

X

X

X

W

Phosphate Fertilizer Industry: Triple Superphosphate Plants

X

X

X

X

X

Phosphate Fertilizer Industry: Granular Triple Superphosphate

X

X

X

X

Y

Coal Preparation Plants

X

X

X

X

Z

Ferroally Production Facilities

X

X

X

X

AA

Steel Plants: Electric Arc Furnaces

X

X

X

X

AAa

Electric Arc Furnaces and Argon-Oxygen Decarburization Vessels in Steel Plants

X

X

X

BB

Kraft Pulp Mills

X

X

X

CC

Glass Manufacturing Plants

X

X

X

DD

Grain Elevators

X

X

X

EE

Surface Coating of Metal Furniture

X

X

X

GG

Stationary Gas Turbines

X

X

X

HH

Lime Plants

X

X

X

KK

Lead Acid Battery Manufacturing Plants

X

X

LL

Metallic Mineral Processing Plants

X

X

X

MM

Automobile and Light-Duty Truck Surface Coating Operations

X

X

NN

Phosphate Rock Plants

X

X

PP

Ammonium Sulfate Manufacturing Plants

X

X

QQ

Graphic Art Industry Publication Rotogravure Printing

X

X

X

X

RR

Pressure Sensitive Tape and Label Surface Coating Operations

X

X

X

SS

Industrial Surface Coating: Large Appliances

X

X

X

TT

Metal Coil Surface Coating

X

X

X

UU

Asphalt Processing and Asphalt Roofing Manufacture

X

X

X

VV

Equipment Leaks of Volatile Organic Compounds in Synthetic Organic Chemical Manufacturing Industry

X

X

WW

Beverage Can Surface Coating Industry

X

X

X

XX

Bulk Gasoline Terminals

X

X

X

FFF

Flexible Vinyl and Urethane Coating and Printing

X

X

X

GGG

Equipment Leaks of VOC in Petroleum Refineries

X

X

HHH

Synthetic Fiber Production Facilities

X

X

JJJ

Petroleum Dry Clearners

X

X

X

KKK

Equipment Leaks of VOC from Onshore Natural Gas Processing Plants

LLL

Onshore Natural Gas Processing Plants; SO 2 Emissions

X

OOO

Nonmetallic Mineral Processing Plants

X

X

PPP

Wool Fiberglass Insulation Manufacturing Plants

X

X

(33) State of New Mexico: New Mexico Environment Department, P.O. Box 5469, Santa Fe, New Mexico 87502-5469. Note: For a list of delegated standards for New Mexico (excluding Bernalillo County and Indian country), see paragraph (e)(1) of this section.

(34) New York: New York State Department of Environmental Conservation, 50 Wolf Road Albany, New York 12233, attention: Division of Air Resources.

(35) State of North Carolina: North Carolina Department of Environmental Quality, Division of Air Quality, 1641 Mail Service Center, Raleigh, North Carolina 27699-1641 or local agencies, Forsyth County Office of Environmental Assistance and Protection, 201 North Chestnut Street, Winston-Salem, North Carolina 27101-4120; Mecklenburg County Land Use and Environmental Services Agency, Air Quality, 2145 Suttle Avenue, Charlotte, North Carolina 28208; Western North Carolina Regional Air Quality Agency, 125 S. Lexington Ave., Suite 101, Asheville, North Carolina 28801-3661.

(36) State of North Dakota, North Dakota Department of Environmental Quality, 918 East Divide Avenue, Bismarck, ND 58501-1947.

Note:

For a table listing Region VIII's NSPS delegation status, see paragraph (c) of this section.

(37) State of Ohio:

(i) Medina, Summit and Portage Counties; Director, Akron Regional Air Quality Management District, 146 South High Street, Room 904, Akron, OH 44308.

(ii) Stark County; Director, Canton City Health Department, Air Pollution Control Division, 420 Market Avenue North, Canton, Ohio 44702-1544.

(iii) Butler, Clermont, Hamilton, and Warren Counties; Director, Hamilton County Department of Environmental Services, 250 William Howard Taft Road, Cincinnati, Ohio 45219-2660.

(iv) Cuyahoga County; Commissioner, Cleveland Department of Public Health, Division of Air Quality, 75 Erieview Plaza 2nd Floor, Cleveland, Ohio 44114.

(v) Clark, Darke, Greene, Miami, Montgomery, and Preble Counties; Director, Regional Air Pollution Control Agency, 117 South Main Street, Dayton, Ohio 45422-1280.

(vi) Lucas County and the City of Rossford (in Wood County); Director, City of Toledo, Division of Environmental Services, 348 South Erie Street, Toledo, OH 43604.

(vii) Adams, Brown, Lawrence, and Scioto Counties; Portsmouth Local Air Agency, 605 Washington Street, Third Floor, Portsmouth, OH 45662.

(viii) Allen, Ashland, Auglaize, Crawford, Defiance, Erie, Fulton, Hancock, Hardin, Henry, Huron, Marion, Mercer, Ottawa, Paulding, Putnam, Richland, Sandusky, Seneca, Van Wert Williams, Wood (Except City of Rossford), and Wyandot Counties; Ohio Environmental Protection Agency, Northwest District Office, Air Pollution Control, 347 North Dunbridge Road, Bowling Green, Ohio 43402.

(ix) Ashtabula, Caroll, Colombiana, Holmes, Lorain, and Wayne Counties; Ohio Environmental Protection Agency, Northeast District Office, Air Pollution Unit, 2110 East Aurora Road, Twinsburg, OH 44087.

(x) Athens, Belmont, Coshocton, Gallia, Guemsey, Harrison, Hocking, Jackson, Jefferson, Meigs, Monroe, Morgan, Muskingum, Noble, Perry, Pike, Ross, Tuscarawas, Vinton, and Washington Counties; Ohio Environmental Protection Agency, Southeast District Office, Air Pollution Unit, 2195 Front Street, Logan, OH 43138.

(xi) Champaign, Clinton, Highland, Logan, and Shelby Counties; Ohio Environmental Protection Agency, Southwest District Office, Air Pollution Unit, 401 East Fifth Street, Dayton, Ohio 45402-2911.

(xii) Delaware, Fairfield, Fayette, Franklin, Knox, Licking, Madison, Morrow, Pickaway, and Union Counties; Ohio Environmental Protection Agency, Central District Office, Air Pollution control, 50 West Town Street, Suite 700, Columbus, Ohio 43215.

(xiii) Geauga and Lake Counties; Lake County General Health District, Air Pollution Control, 33 Mill Street, Painesville, OH 44077.

(xiv) Mahoning and Trumbull Counties; Mahoning-Trumbull Air Pollution Control Agency, 345 Oak Hill Avenue, Suite 200, Youngstown, OH 44502.

(38) State of Oklahoma: State of Oklahoma, Department of Environmental Quality, Air Quality Division, P.O. Box 1677, Oklahoma City, OK 73101-1677.

(39) State of Oregon. (i) Oregon Department of Environmental Quality (ODEQ), 811 SW Sixth Avenue, Portland, OR 97204-1390, http://www.deq.state.or.us.

(ii) Lane Regional Air Pollution Authority (LRAPA), 1010 Main Street, Springfield, Oregon 97477, http://www.lrapa.org.

(40)(i) City of Philadelphia, Department of Public Health, Air Management Services, 321 University Avenue, Philadelphia, Pennsylvania 19104.

(ii) Commonwealth of Pennsylvania, Department of Environmental Protection, Bureau of Air Quality Control, P.O. Box 8468, 400 Market Street, Harrisburg, Pennsylvania 17105.

(iii) Allegheny County Health Department, Bureau of Environmental Quality, Division of Air Quality, 301 39th Street, Pittsburgh, Pennsylvania 15201.

(41) State of Rhode Island, Rhode Island Department of Environmental Management, Office of Air Resources, 235 Promenade Street, Providence, RI 02908.

(42) State of South Carolina: South Carolina Department of Health and Environmental Control, 2600 Bull Street, Columbia, South Carolina 29201.

(43) State of South Dakota, Air Quality Program, Department of Agriculture and Natural Resources, Joe Foss Building, 523 East Capitol, Pierre, SD 57501-3181.

(44) State of Tennessee: Tennessee Department of Environment and Conservation, Division of Air Pollution Control, William R. Snodgrass Tennessee Tower, 312 Rosa L. Parks Avenue, 15th Floor, Nashville, Tennessee 37243, or local agencies, Knox County Air Quality Management—Department of Public Health, 140 Dameron Avenue, Knoxville, Tennessee 37917; Metro Public Health Department, Pollution Control Division, 2500 Charlotte Ave., Nashville, Tennessee 37209; Chattanooga-Hamilton County Air Pollution Control Bureau, 6125 Preservation Drive, Chattanooga, Tennessee 37416; Shelby County Health Department, Pollution Control Section, 814 Jefferson Avenue, Memphis, Tennessee 38105.

(45) State of Texas, Texas Air Control Board, 6330 Highway 290 East, Austin, TX 78723.

(46) State of Utah, Division of Air Quality, Department of Environmental Quality, P.O. Box 144820, Salt Lake City, UT 84114-4820.

Note:

For a table listing Region VIII's NSPS delegation status, see paragraph (c) of this section.

(47) State of Vermont, Agency of Natural Resources, Department of Environmental Conservation, Air Quality and Climate Division, Davis 2, One National Life Drive, Montpelier, VT 05620-3802.

(48) Commonwealth of Virginia, Department of Environmental Quality, 629 East Main Street, Richmond, Virginia 23219.

(49) State of Washington. (i) Washington State Department of Ecology (Ecology), P.O. Box 47600, Olympia, WA 98504-7600, http://www.ecy.wa.gov/

(ii) Benton Clean Air Authority (BCAA), 650 George Washington Way, Richland, WA 99352-4289, http://www.bcaa.net/

(iii) Northwest Air Pollution Control Authority (NWAPA), 1600 South Second St., Mount Vernon, WA 98273-5202, http://www.nwair.org/

(iv) Olympic Regional Clean Air Agency (ORCAA), 909 Sleater-Kinney Road S.E., Suite 1, Lacey, WA 98503-1128, http://www.orcaa.org/

(v) Puget Sound Clean Air Agency (PSCAA), 110 Union Street, Suite 500, Seattle, WA 98101-2038, http://www.pscleanair.org/

(vi) Spokane County Air Pollution Control Authority (SCAPCA), West 1101 College, Suite 403, Spokane, WA 99201, http://www.scapca.org/

(vii) Southwest Clean Air Agency (SWCAA), 1308 NE. 134th St., Vancouver, WA 98685-2747, http://www.swcleanair.org/

(viii) Yakima Regional Clean Air Authority (YRCAA), 6 South 2nd Street, Suite 1016, Yakima, WA 98901, http://co.yakima.wa.us/cleanair/default.htm

(ix) The following table lists the delegation status of the New Source Performance Standards for the State of Washington. An “X” indicates the subpart has been delegated, subject to all the conditions and limitations set forth in Federal law and the letters granting delegation. Some authorities cannot be delegated and are retained by EPA. Refer to the letters granting delegation for a discussion of these retained authorities. The dates noted at the end of the table indicate the effective dates of Federal rules that have been delegated. Authority for implementing and enforcing any amendments made to these rules after these effective dates are not delegated.

NSPS Subparts Delegated to Washington Air Agencies

Subpart 1

Washington

Ecology 2

BCAA 3

NWAPA 4

ORCAA 5

PSCAA 6

SCAPCA 7

SWCAA 8

YRCAA 9

A General Provisions

X

X

X

X

X

X

X

X

B Adoption and Submittal of State Plans for Designated Facilities

C Emission Guidelines and Compliance Times

Cb Large Municipal Waste Combustors that are Constructed on or before September 20, 1994 (Emission Guidelines and Compliance Times)

Cc Municipal Solid Waste Landfills (Emission Guidelines and Compliance Times)

Cd Sulfuric Acid Production Units (Emission Guidelines and Compliance Times)

Ce Hospital/Medical/Infectious Waste Incinerators (Emission Guidelines and Compliance Times)

D Fossil-Fuel-Fired Steam Generators for which Construction is Commenced after August 17, 1971

X

X

X

X

X

X

X

X

Da Electric Utility Steam Generating Units for which Construction is Commenced after September 18, 1978

X

X

X

X

X

X

X

X

Db Industrial-Commercial-Institutional Steam Generating Units

X

X

X

X

X

X

X

X

Dc Small Industrial-Commercial-Institutional Steam Generating Units

X

X

X

X

X

X

X

X

E Incinerators

X

X

X

X

X

X

X

X

Ea Municipal Waste Combustors for which Construction is Commenced after December 20, 1989 and on or before September 20, 1994

X

X

X

X

X

X

X

X

Eb—Large Municipal Waste Combustors

X

X

X

X

Ec—Hospital/Medical/Infectious Waste Incinerators

X

X

X

X

X

X

F Portland Cement Plants

X

X

X

X

X

X

X

X

G Nitric Acid Plants

X

X

X

X

X

X

X

X

H Sulfuric Acid Plants

X

X

X

X

X

X

X

X

I Hot Mix Asphalt Facilities

X

X

X

X

X

X

X

X

J Petroleum Refineries

X

X

X

X

X

X

X

X

K Storage Vessels for Petroleum Liquids for which Construction, Reconstruction, or Modification Commenced after June 11, 1973 and prior to May 19, 1978

X

X

X

X

X

X

X

X

Ka Storage Vessels for Petroleum Liquids for which Construction, Reconstruction, or Modification Commenced after May 18, 1978 and prior to July 23, 1984

X

X

X

X

X

X

X

X

Kb VOC Liquid Storage Vessels (including Petroleum Liquid Storage Vessels) for which Construction, Reconstruction, or Modification Commenced after July 23, 1984

X

X

X

X

X

X

X

X

L Secondary Lead Smelters

X

X

X

X

X

X

X

X

M Secondary Brass and Bronze Production Plants

X

X

X

X

X

X

X

X

N Primary Emissions from Basic Oxygen Process Furnaces for which Construction is Commenced after June 11, 1973

X

X

X

X

X

X

X

X

Na Secondary Emissions from Basic Oxygen Process Steel-making Facilities for which Construction is Commenced after January 20, 1983

X

X

X

X

X

X

X

X

O Sewage Treatment Plants

X

X

X

X

X

X

X

X

P Primary Copper Smelters

X

X

X

X

X

X

X

X

Q Primary Zinc Smelters

X

X

X

X

X

X

X

X

R Primary Lead Smelters

X

X

X

X

X

X

X

X

S Primary Aluminum Reduction Plants 10

X

T Phosphate Fertilizer Industry: Wet Process Phosphoric Acid Plants

X

X

X

X

X

X

X

X

U Phosphate Fertilizer Industry: Superphosphoric Acid Plants

X

X

X

X

X

X

X

X

V Phosphate Fertilizer Industry: Diammonium Phosphate Plants

X

X

X

X

X

X

X

X

W Phosphate Fertilizer Industry: Triple Superphosphate Plants

X

X

X

X

X

X

X

X

X Phosphate Fertilizer Industry: Granular Triple Superphosphate Storage Facilities

X

X

X

X

X

X

X

X

Y Coal Preparation Plants

X

X

X

X

X

X

X

X

Z Ferroalloy Production Facilities

X

X

X

X

X

X

X

X

AA Steel Plants: Electric Arc Furnaces Constructed after October 21, 1974 and on or before August 17, 1983

X

X

X

X

X

X

X

X

AAa Steel Plants: Electric Arc Furnaces and Argon-Oxygen Decarburization Vessels Constructed after August 7, 1983

X

X

X

X

X

X

X

X

BB Kraft Pulp Mills 11

X

CC Glass Manufacturing Plants

X

X

X

X

X

X

X

X

DD Grain Elevators

X

X

X

X

X

X

X

X

EE Surface Coating of Metal Furniture

X

X

X

X

X

X

X

X

GG Stationary Gas Turbines

X

X

X

X

X

X

X

X

HH Lime Manufacturing Plants

X

X

X

X

X

X

X

X

KK Lead-Acid Battery Manufacturing Plants

X

X

X

X

X

X

X

X

LL Metallic Mineral Processing Plants

X

X

X

X

X

X

X

X

MM Automobile and Light Duty Truck Surface Coating Operations

X

X

X

X

X

X

X

X

NN Phosphate Rock Plants

X

X

X

X

X

X

X

X

PP Ammonium Sulfate Manufacture

X

X

X

X

X

X

X

X

QQ Graphic Arts Industry: Publication Rotogravure Printing

X

X

X

X

X

X

X

X

RR Pressure Sensitive Tape and Label Surface Coating Standards

X

X

X

X

X

X

X

X

SS Industrial Surface Coating: Large Appliances

X

X

X

X

X

X

X

X

TT Metal Coil Surface Coating

X

X

X

X

X

X

X

X

UU Asphalt Processing and Asphalt Roof Manufacture

X

X

X

X

X

X

X

X

VV Equipment Leaks of VOC in Synthetic Organic Chemical Manufacturing Industry

X

X

X

X

X

X

X

X

WW Beverage Can Surface Coating Industry

X

X

X

X

X

X

X

X

XX Bulk Gasoline Terminals

X

X

X

X

X

X

X

X

AAA New Residential Wood Heaters

BBB Rubber Tire Manufacturing Industry

X

X

X

X

X

X

X

X

DDD VOC Emissions from Polymer Manufacturing Industry

X

X

X

X

X

X

X

X

FFF Flexible Vinyl and Urethane Coating and Printing

X

X

X

X

X

X

X

X

GGG Equipment Leaks of VOC in Petroleum Refineries

X

X

X

X

X

X

X

X

HHH Synthetic Fiber Production Facilities

X

X

X

X

X

X

X

X

III VOC Emissions from Synthetic Organic Chemical Manufacturing Industry Air Oxidation Unit Processes

X

X

X

X

X

X

X

X

JJJ Petroleum Dry Cleaners

X

X

X

X

X

X

X

X

KKK Equipment Leaks of VOC from Onshore Natural Gas Processing Plants

X

X

X

X

X

X

X

X

LLL Onshore Natural Gas Processing: SO 2 Emissions

X

X

X

X

X

X

X

X

NNN VOC Emissions from Synthetic Organic Chemical Manufacturing Industry Distillation Operations

X

X

X

X

X

X

X

X

OOO Nonmetallic Mineral Processing Plants

X

X

X

PPP Wool Fiberglass Insulation Manufacturing Plants

X

X

X

X

X

X

X

X

QQQ VOC Emissions from Petroleum Refinery Wastewater Systems

X

X

X

X

X

X

X

X

RRR VOCs from Synthetic Organic Chemical Manufacturing Industry Reactor Processes

X

X

X

X

X

X

X

X

SSS Magnetic Tape Coating Facilities

X

X

X

X

X

X

X

X

TTT Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines

X

X

X

X

X

X

X

X

UUU Calciners and Dryers in Mineral Industries

X

X

X

X

X

X

X

X

VVV Polymeric Coating of Supporting Substrates Facilities

X

X

X

X

X

X

X

X

WWW Municipal Solid Waste Landfills

X

X

X

X

X

X

X

X

AAAA Small Municipal Waste Combustion Units for which Construction is Commenced after August 30, 1999 or for which Modification or Reconstruction is Commenced after June 6, 2001

X

X

X

X

X

X

BBBB Small Municipal Waste Combustion Units Constructed on or before August 30, 1999 (Emission Guidelines and Compliance Times)

CCCC Commercial and Industrial Solid Waste Incineration Units for which Construction is Commenced after November, 30, 1999 or for which Modification or Reconstruction is Commenced on or after June 1, 2001

X

X

X

X

X

X

DDDD Commercial and Industrial Solid Waste Incineration Units that Commenced Construction on or before November 30, 1999 (Emission Guidelines and Compliance Times)

1 Any authority within any subpart of this part that is not delegable, is not delegated. Please refer to Attachment B to the delegation letters for a listing of the NSPS authorities excluded from delegation.

2 Washington State Department of Ecology, for 40 CFR 60.17(h)(1), (h)(2), (h)(3) and 40 CFR part 60, subpart AAAA, as in effect on June 6, 2001; for 40 CFR part 60, subpart CCCC, as in effect on June 1, 2001; and for all other NSPS delegated, as in effect February 20, 2001.

3 Benton Clean Air Authority, for 40 CFR 60.17(h)(1), (h)(2), (h)(3) and 40 CFR part 60, subpart AAAA, as in effect on June 6, 2001; for 40 CFR part 60, subpart CCCC, as in effect on June 1, 2001; and for all other NSPS delegated, as in effect February 20, 2001.

4 Northwest Air Pollution Authority, for all NSPS delegated, as in effect on July 1, 2000.

5 Olympic Regional Clean Air Authority, for 40 CFR 60.17(h)(1), (h)(2), (h)(3) and 40 CFR part 60, subpart AAAA, as in effect on June 6, 2001; for 40 CFR part 60, subpart CCCC, as in effect on June 1, 2001; and for all other NSPS delegated, as in effect February 20, 2001.

6 Puget Sound Clean Air Authority, for all NSPS delegated, as in effect on July 1, 2002.

7 Spokane County Air Pollution Control Authority, for 40 CFR 60.17(h)(1), (h)(2), (h)(3) and 40 CFR part 60, subpart AAAA, as in effect on June 6, 2001; for 40 CFR part 60, subpart CCCC, as in effect on June 1, 2001; and for all other NSPS delegated, as in effect February 20, 2001.

8 Southwest Clean Air Agency, for all NSPS delegated, as in effect on July 1, 2000.

9 Yakima Regional Clean Air Authority, for 40 CFR 60.17(h)(1), (h)(2), (h)(3) and 40 CFR part 60, subpart AAAA, as in effect on June 6, 2001; for 40 CFR part 60, subpart CCCC, as in effect on June 1, 2001; and for all other NSPS delegated, as in effect February 20, 2001.

10 Subpart S of this part is not delegated to local agencies in Washington because the Washington State Department of Ecology retains sole authority to regulate Primary Aluminum Plants, pursuant to Washington Administrative Code 173-415-010.

11 Subpart BB of this part is not delegated to local agencies in Washington because the Washington State Department of Ecology retains sole authority to regulate Kraft and Sulfite Pulping Mills, pursuant to Washington State Administrative Code 173-405-012 and 173-410-012.

(50) State of West Virginia, Department of Environmental Protection, Division of Air Quality, 601 57th Street, SE., Charleston, West Virginia 25304.

(51) State of Wisconsin: Wisconsin Department of Natural Resouces, 101 South Webster St., P.O. Box 7921, Madison, Wisconsin 53707-7921.

(52) State of Wyoming, Department of Environmental Quality, Air Quality Division, Herschler Building, 122 West 25th Street, Cheyenne, WY 82002.

Note:

For a table listing Region VIII's NSPS delegation status, see paragraph (c) of this section.

(53) Territory of Guam: Guam Environmental Protection Agency, P.O. Box 22439 GMF, Barrigada, Guam 96921.

Note:

For tables listing the delegation status of agencies in Region IX, see paragraph (d) of this section.

(54) Commonwealth of Puerto Rico: Commonwealth of Puerto Rico Environmental Quality Board, P.O. Box 11488, Santurce, PR 00910, Attention: Air Quality Area Director (see table under § 60.4(b)(FF)(1)).

(55) U.S. Virgin Islands: U.S. Virgin Islands Department of Conservation and Cultural Affairs, P.O. Box 578, Charlotte Amalie, St. Thomas, VI 00801.

(56) American Samoa: American Samoa Environmental Protection Agency, P.O. Box PPA, Pago Pago, American Samoa 96799.

Note:

For tables listing the delegation status of agencies in Region IX, see paragraph (d) of this section.

(57) Commonwealth of the Northern Mariana Islands: CNMI Division of Environmental Quality, P.O. Box 501304, Saipan, MP 96950.

Note:

For tables listing the delegation status of agencies in Region IX, see paragraph (d) of this section.

(c) The delegation status table for New Source Performance Standards for Region VIII can be found online at http://www2.epa.gov/region8/air-program.

(d) The following tables list the specific part 60 standards that have been delegated unchanged to the air pollution control agencies in Region IX. The (X) symbol is used to indicate each standard that has been delegated. The following provisions of this subpart are not delegated: §§ 60.4(b), 60.8(b), 60.9, 60.11(b), 60.11(e), 60.13(a), 60.13(d)(2), 60.13(g), 60.13(i).

(1) Arizona. The following table identifies delegations for Arizona:

Table 3 to Paragraph ( d )(1)—Delegation Status for New Source Performance Standards for Arizona

Subpart

Air pollution control agency

Arizona DEQ

Maricopa County

Pima County

Pinal County

A

General Provisions

X

X

X

X

D

Fossil-Fuel Fired Steam Generators Constructed After August 17, 1971

X

X

X

X

Da

Electric Utility Steam Generating Units Constructed After September 18, 1978

X

X

X

X

Db

Industrial-Commercial-Institutional Steam Generating Units

X

X

X

X

Dc

Small Industrial-Commercial-Institutional Steam Generating Units

X

X

X

X

E

Incinerators

X

X

X

X

Ea

Municipal Waste Combustors Constructed After December 20, 1989 and On or Before September 20, 1994

X

X

X

X

Eb

Large Municipal Waste Combustors Constructed After September 20, 1994

X

X

X

Ec

Hospital/Medical/Infectious Waste Incinerators for Which Construction is Commenced After June 20, 1996

X

X

X

F

Portland Cement Plants

X

X

X

G

Nitric Acid Plants

X

X

X

X

Ga

Nitric Acid Plants For Which Construction, Reconstruction or Modification Commenced After October 14, 2011

X

X

H

Sulfuric Acid Plant

X

X

X

X

I

Hot Mix Asphalt Facilities

X

X

X

X

J

Petroleum Refineries

X

X

X

Ja

Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After May 14, 2007

X

K

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After June 11, 1973, and Prior to May 19, 1978

X

X

X

X

Ka

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After May 18, 1978, and Prior to July 23, 1984

X

X

X

X

Kb

Volatile Organic Liquid Storage Vessels (Including Petroleum Liquid Storage Vessels) for Which Construction, Reconstruction, or Modification Commenced After July 23, 1984

X

X

X

X

L

Secondary Lead Smelters

X

X

X

M

Secondary Brass and Bronze Production Plants

X

X

X

X

N

Primary Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After June 11, 1973

X

X

X

X

Na

Secondary Emissions from Basic Oxygen Process Steelmaking Facilities for Which Construction is Commenced After January 20, 1983

X

X

X

X

O

Sewage Treatment Plants

X

X

X

X

P

Primary Copper Smelters

X

X

X

Q

Primary Zinc Smelters

X

X

X

R

Primary Lead Smelters

X

X

X

S

Primary Aluminum Reduction Plants

X

X

X

X

T

Phosphate Fertilizer Industry: Wet Process Phosphoric Acid Plants

X

X

X

X

U

Phosphate Fertilizer Industry: Superphosphoric Acid Plants

X

X

X

X

V

Phosphate Fertilizer Industry: Diammonium Phosphate Plants

X

X

X

X

W

Phosphate Fertilizer Industry: Triple Superphosphate Plants

X

X

X

X

X

Phosphate Fertilizer Industry: Granular Triple Superphosphate Storage Facilities

X

X

X

X

Y

Coal Preparation and Processing Plants

X

X

X

X

Z

Ferroalloy Production Facilities

X

X

X

X

AA

Steel Plants: Electric Arc Furnaces Constructed After October 21, 1974 and On or Before August 17, 1983

X

X

X

X

AAa

Steel Plants: Electric Arc Furnaces and Argon-Oxygen Decarburization Vessels Constructed After August 7, 1983

X

X

X

X

BB

Kraft Pulp Mills

X

X

X

X

BBa

Kraft Pulp Mill Sources for which Construction, Reconstruction or Modification Commenced after May 23, 2013

X

X

CC

Glass Manufacturing Plants

X

X

X

X

DD

Grain Elevators

X

X

X

X

EE

Surface Coating of Metal Furniture

X

X

X

X

FF

(Reserved)

GG

Stationary Gas Turbines

X

X

X

X

HH

Lime Manufacturing Plants

X

X

X

X

KK

Lead-Acid Battery Manufacturing Plants

X

X

X

X

LL

Metallic Mineral Processing Plants

X

X

X

X

MM

Automobile and Light Duty Trucks Surface Coating Operations

X

X

X

X

NN

Phosphate Rock Plants

X

X

X

X

PP

Ammonium Sulfate Manufacture

X

X

X

X

QQ

Graphic Arts Industry: Publication Rotogravure Printing

X

X

X

X

RR

Pressure Sensitive Tape and Label Surface Coating Operations

X

X

X

X

SS

Industrial Surface Coating: Large Appliances

X

X

X

X

TT

Metal Coil Surface Coating

X

X

X

X

UU

Asphalt Processing and Asphalt Roofing Manufacture

X

X

X

X

VV

Equipment Leaks of VOC in the Synthetic Organic Industry Chemicals Manufacturing

X

X

X

X

VVa

Equipment Leaks of VOC in the Synthetic Organic Industry for Which Construction, Reconstruction, or Chemicals Manufacturing Modification Commenced After November 7, 2006

X

X

X

WW

Beverage Can Surface Coating Industry

X

X

X

X

XX

Bulk Gasoline Terminals

X

X

X

X

AAA

New Residential Wood Heaters

X

X

X

X

BBB

Rubber Tire Manufacturing Industry

X

X

X

X

CCC

(Reserved)

DDD

Volatile Organic Compounds (VOC) Emissions from the Polymer Manufacturing Industry

X

X

X

X

EEE

(Reserved)

FFF

Flexible Vinyl and Urethane Coating and Printing

X

X

X

X

GGG

Equipment Leaks of VOC in Petroleum Refineries

X

X

X

GGGa

Equipment Leaks of VOC in Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After November 7, 2006

X

X

HHH

Synthetic Fiber Production Facilities

X

X

X

X

III

Volatile Organic Compound (VOC) Emissions From the Synthetic Organic Chemical Manufacturing Industry (SOCMI) Air Oxidation Unit Processes

X

X

X

X

JJJ

Petroleum Dry Cleaners

X

X

X

X

KKK

Equipment Leaks of VOC From Onshore Natural Gas Processing Plants

X

X

X

X

LLL

Onshore Natural Gas Processing: SO 2 Emissions

X

X

X

X

MMM

(Reserved)

NNN

Volatile Organic Compound (VOC) Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Distillation Operations

X

X

X

X

OOO

Nonmetallic Mineral Processing Plants

X

X

X

X

PPP

Wool Fiberglass Insulation Manufacturing Plants

X

X

X

X

QQQ

VOC Emissions From Petroleum Refinery Wastewater Systems

X

X

X

RRR

Volatile Organic Compound Emissions from Synthetic Organic Chemical Manufacturing Industry (SOCMI) Reactor Processes

X

X

X

SSS

Magnetic Tape Coating Facilities

X

X

X

X

TTT

Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines

X

X

X

X

UUU

Calciners and Dryers in Mineral Industries

X

X

X

VVV

Polymeric Coating of Supporting Substrates Facilities

X

X

X

X

WWW

Municipal Solid Waste Landfills

X

X

X

XXX

Municipal Solid Waste Landfills that Commenced Construction, Reconstruction, or Modification After July 17, 2014

X

X

AAAA

Small Municipal Waste Combustion Units for Which Construction is Commenced After August 30, 1999 or for Which Modification or Reconstruction is Commended After June 6, 2001

X

X

X

CCCC

Commercial and Industrial Solid Waste Incineration Units for Which Construction Is Commenced After November 30, 1999 or for Which Modification or Reconstruction Is Commenced on or After June 1, 2001

X

X

X

EEEE

Other Solid Waste Incineration Units for Which Construction is Commenced After December 9, 2004, or for Which Modification or Reconstruction is Commenced on or After June 16, 2006

X

X

X

GGGG

(Reserved)

HHHH

(Reserved)

IIII

Stationary Compression Ignition Internal Combustion Engines

X

X

X

JJJJ

Stationary Spark Ignition Internal Combustion Engines

X

X

KKKK

Stationary Combustion Turbines

X

X

X

LLLL

New Sewage Sludge Incineration Units

X

MMMM

Emissions Guidelines and Compliance Times for Existing Sewage Sludge Incineration Units

X

OOOO

Crude Oil and Natural Gas Production, Transmission, and Distribution

X

X

OOOOa

Standards of Performance for Crude Oil and Natural Gas Facilities for Which Construction, Modification or Reconstruction Commenced After September 18, 2015

X

X

QQQQ

Standards of Performance for New Residential Hydronic Heaters and Forced-Air Furnaces

X

X

TTTT

Standards of Performance for Greenhouse Gas Emissions for Electric Generating Units

X

X

(2) California. The following tables identify delegations for each of the local air pollution control agencies of California.

(i) Delegations for Amador County Air Pollution Control District, Antelope Valley Air Quality Management District, Bay Area Air Quality Management District, and Butte County Air Quality Management District are shown in the following table:

Table 4 to Paragraph (d)(2)(i) —Delegation Status for New Source Performance Standards for Amador County APCD, Antelope Valley AQMD, Bay Area AQMD, and Butte County AQMD

Subpart

Air pollution control agency

Amador County APCD

Antelope Valley AQMD

Bay Area AQMD

Butte County AQMD

A

General Provisions

X

Ba

Adoption and Submittal of State Plans for Designated Facilities

X

Cf

Emission Guidelines and Compliance Times for Municipal Solid Waste Landfills

X

D

Fossil-Fuel Fired Steam Generators Constructed After August 17, 1971

X

X

Da

Electric Utility Steam Generating Units Constructed After September 18, 1978

X

X

Db

Industrial-Commercial-Institutional Steam Generating Units

X

X

Dc

Small Industrial-Commercial-Institutional Steam Generating Units

X

X

E

Incinerators

X

X

Ea

Municipal Waste Combustors Constructed After December 20, 1989 and On or Before September 20, 1994

X

X

Eb

Large Municipal Waste Combustors Constructed After September 20, 1994

X

Ec

Hospital/Medical/Infectious Waste Incinerators for Which Construction is Commenced After June 20, 1996

X

F

Portland Cement Plants

X

X

G

Nitric Acid Plants

X

X

Ga

Nitric Acid Plants For Which Construction, Reconstruction or Modification Commenced After October 14, 2011

X

H

Sulfuric Acid Plant

X

X

I

Hot Mix Asphalt Facilities

X

X

J

Petroleum Refineries

X

X

Ja

Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After May 14, 2007

X

K

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After June 11, 1973, and Prior to May 19, 1978

X

X

Ka

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After May 18, 1978, and Prior to July 23, 1984

X

X

Kb

Volatile Organic Liquid Storage Vessels (Including Petroleum Liquid Storage Vessels) for Which Construction, Reconstruction, or Modification Commenced After July 23, 1984

X

X

L

Secondary Lead Smelters

X

X

M

Secondary Brass and Bronze Production Plants

X

X

N

Primary Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After June 11, 1973

X

X

Na

Secondary Emissions from Basic Oxygen Process Steelmaking Facilities for Which Construction is Commenced After January 20, 1983

X

X

O

Sewage Treatment Plants

X

X

P

Primary Copper Smelters

X

X

Q

Primary Zinc Smelters

X

X

R

Primary Lead Smelters

X

X

S

Primary Aluminum Reduction Plants

X

X

T

Phosphate Fertilizer Industry: Wet Process Phosphoric Acid Plants

X

U

Phosphate Fertilizer Industry: Superphosphoric Acid Plants

X

X

V

Phosphate Fertilizer Industry: Diammonium Phosphate Plants

X

X

W

Phosphate Fertilizer Industry: Triple Superphosphate Plants

X

X

X

Phosphate Fertilizer Industry: Granular Triple Superphosphate Storage Facilities

X

X

Y

Coal Preparation and Processing Plants

X

X

Z

Ferroalloy Production Facilities

X

X

AA

Steel Plants: Electric Arc Furnaces Constructed After October 21, 1974 and On or Before August 17, 1983

X

X

AAa

Steel Plants: Electric Arc Furnaces and Argon-Oxygen Decarburization Vessels Constructed After August 7, 1983

X

X

BB

Kraft Pulp Mills

X

X

BBa

Kraft Pulp Mill Sources for which Construction, Reconstruction or Modification Commenced after May 23, 2013

X

CC

Glass Manufacturing Plants

X

X

DD

Grain Elevators

X

X

EE

Surface Coating of Metal Furniture

X

X

FF

(Reserved)

GG

Stationary Gas Turbines

X

X

HH

Lime Manufacturing Plants

X

X

KK

Lead-Acid Battery Manufacturing Plants

X

X

LL

Metallic Mineral Processing Plants

X

X

MM

Automobile and Light Duty Trucks Surface Coating Operations

X

X

NN

Phosphate Rock Plants

X

X

PP

Ammonium Sulfate Manufacture

X

X

QQ

Graphic Arts Industry: Publication Rotogravure Printing

X

X

RR

Pressure Sensitive Tape and Label Surface Coating Operations

X

X

SS

Industrial Surface Coating: Large Appliances

X

X

TT

Metal Coil Surface Coating

X

X

UU

Asphalt Processing and Asphalt Roofing Manufacture

X

X

VV

Equipment Leaks of VOC in the Synthetic Organic Industry Chemicals Manufacturing

X

X

VVa

Equipment Leaks of VOC in the Synthetic Organic Industry for Which Construction, Reconstruction, or Chemicals Manufacturing Modification Commenced After November 7, 2006

X

WW

Beverage Can Surface Coating Industry

X

X

XX

Bulk Gasoline Terminals

AAA

New Residential Wood Heaters

X

X

BBB

Rubber Tire Manufacturing Industry

X

X

CCC

(Reserved)

DDD

Volatile Organic Compounds (VOC) Emissions from the Polymer Manufacturing Industry

X

X

EEE

(Reserved)

FFF

Flexible Vinyl and Urethane Coating and Printing

X

X

GGG

Equipment Leaks of VOC in Petroleum Refineries

X

X

GGGa

Equipment Leaks of VOC in Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After November 7, 2006

X

HHH

Synthetic Fiber Production Facilities

X

X

III

Volatile Organic Compound (VOC) Emissions From the Synthetic Organic Chemical Manufacturing Industry (SOCMI) Air Oxidation Unit Processes

X

JJJ

Petroleum Dry Cleaners

X

X

KKK

Equipment Leaks of VOC From Onshore Natural Gas Processing Plants

X

X

LLL

Onshore Natural Gas Processing: SO 2 Emissions

X

MMM

(Reserved)

NNN

Volatile Organic Compound (VOC) Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Distillation Operations

X

X

OOO

Nonmetallic Mineral Processing Plants

X

X

PPP

Wool Fiberglass Insulation Manufacturing Plants

X

X

QQQ

VOC Emissions From Petroleum Refinery Wastewater Systems

X

RRR

Volatile Organic Compound Emissions from Synthetic Organic Chemical Manufacturing Industry (SOCMI) Reactor Processes

X

SSS

Magnetic Tape Coating Facilities

X

X

TTT

Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines

X

X

UUU

Calciners and Dryers in Mineral Industries

X

X

VVV

Polymeric Coating of Supporting Substrates Facilities

X

X

WWW

Municipal Solid Waste Landfills

X

XXX

Municipal Solid Waste Landfills that Commenced Construction, Reconstruction, or Modification After July 17, 2014

X

AAAA

Small Municipal Waste Combustion Units for Which Construction is Commenced After August 30, 1999 or for Which Modification or Reconstruction is Commended After June 6, 2001

X

CCCC

Commercial and Industrial Solid Waste Incineration Units for Which Construction Is Commenced After November 30, 1999 or for Which Modification or Reconstruction Is Commenced on or After June 1, 2001

X

DDDD

Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units

X

EEEE

Other Solid Waste Incineration Units for Which Construction is Commenced After December 9, 2004, or for Which Modification or Reconstruction is Commenced on or After June 16, 2006

X

GGGG

(Reserved)

HHHH

(Reserved)

IIII

Stationary Compression Ignition Internal Combustion Engines

X

JJJJ

Stationary Spark Ignition Internal Combustion Engines

X

KKKK

Stationary Combustion Turbines

X

LLLL

New Sewage Sludge Incineration Units

X

MMMM

Emissions Guidelines and Compliance Times for Existing Sewage Sludge Incineration Units

X

OOOO

Crude Oil and Natural Gas Production, Transmission, and Distribution

X

OOOOa

Standards of Performance for Crude Oil and Natural Gas Facilities for Which Construction, Modification or Reconstruction Commenced After September 18, 2015

X

TTTT

Standards of Performance for Greenhouse Gas Emissions for Electric Generating Units

X

UUUUa

Emission Guidelines for Greenhouse Gas Emissions From Existing Electric Utility Generating Units

X

(ii) [Reserved]

(iii) Delegations for Glenn County Air Pollution Control District, Great Basin Unified Air Pollution Control District, Imperial County Air Pollution Control District, and Kern County Air Pollution Control District are shown in the following table:

Delegation Status for New Source Performance Standards for Glenn County APCD, Great Basin Unified APCD, Imperial County APCD, and Kern County APCD

Subpart

Air pollution control agency

Glenn County APCD

Great Basin Unified APCD

Imperial County APCD

Kern County APCD

A

General Provisions

X

X

D

Fossil-Fuel Fired Steam Generators Constructed After August 17, 1971

X

X

Da

Electric Utility Steam Generating Units Constructed After September 18, 1978

X

X

Db

Industrial-Commercial-Institutional Steam Generating Units

X

X

Dc

Small Industrial Steam Generating Units

X

X

E

Incinerators

X

X

Ea

Municipal Waste Combustors Constructed After December 20, 1989 and On or Before September 20, 1994

X

Eb

Municipal Waste Combustors Constructed After September 20, 1994

Ec

Hospital/Medical/Infectious Waste Incinerators for Which Construction is Commenced After June 20, 1996

F

Portland Cement Plants

X

X

G

Nitric Acid Plants

X

X

H

Sulfuric Acid Plants

X

I

Hot Mix Asphalt Facilities

X

X

J

Petroleum Refineries

X

X

K

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After June 11, 1973, and Prior to May 19, 1978

X

X

Ka

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After May 18, 1978, and Prior to July 23, 1984

X

X

Kb

Volatile Organic Liquid Storage Vessels (Including Petroleum Liquid Storage Vessels) for Which Construction, Reconstruction, or Modification Commenced After July 23, 1984

X

X

L

Secondary Lead Smelters

X

X

M

Secondary Brass and Bronze Production Plants

X

X

N

Primary Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After June 11, 1973

X

X

Na

Secondary Emissions from Basic Oxygen Process Steelmaking Facilities for Which Construction is Commenced After January 20, 1983

X

X

O

Sewage Treatment Plants

X

X

P

Primary Copper Smelters

X

X

Q

Primary Zinc Smelters

X

X

R

Primary Lead Smelters

X

X

S

Primary Aluminum Reduction Plants

X

X

T

Phosphate Fertilizer Industry: Wet Process Phosphoric Acid Plants

X

X

U

Phosphate Fertilizer Industry: Superphosphoric Acid Plants

X

X

V

Phosphate Fertilizer Industry: Diammonium Phosphate Plants

X

X

W

Phosphate Fertilizer Industry: Triple Superphosphate Plants

X

X

X

Phosphate Fertilizer Industry: Granular Triple Superphosphate Storage Facilities

X

X

Y

Coal Preparation Plants

X

X

Z

Ferroalloy Production Facilities

X

X

AA

Steel Plants: Electric Arc Furnaces Constructed After October 21, 1974 and On or Before August 17, 1983

X

X

AAa

Steel Plants: Electric Arc Furnaces and Argon-Oxygen Decarburization Vessels Constructed After August 7, 1983

X

X

BB

Kraft pulp Mills

X

X

CC

Glass Manufacturing Plants

X

X

DD

Grain Elevators

X

X

EE

Surface Coating of Metal Furniture

X

X

FF

(Reserved)

GG

Stationary Gas Turbines

X

X

HH

Lime Manufacturing Plants

X

X

KK

Lead-Acid Battery Manufacturing Plants

X

X

LL

Metallic Mineral Processing Plants

X

X

MM

Automobile and Light Duty Trucks Surface Coating Operations

X

X

NN

Phosphate Rock Plants

X

X

PP

Ammonium Sulfate Manufacture

X

X

QQ

Graphic Arts Industry: Publication Rotogravure Printing

X

X

RR

Pressure Sensitive Tape and Label Surface Coating Operations

X

X

SS

Industrial Surface Coating: Large Appliances

X

X

TT

Metal Coil Surface Coating

X

X

UU

Asphalt Processing and Asphalt Roofing Manufacture

X

X

VV

Equipment Leaks of VOC in the Synthetic Organic Chemicals Manufacturing Industry

X

X

WW

Beverage Can Surface Coating Industry

X

X

XX

Bulk Gasoline Terminals

AAA

New Residential Wool Heaters

X

X

BBB

Rubber Tire Manufacturing Industry

X

X

CCC

(Reserved)

DDD

Volatile Organic Compounds (VOC) Emissions from the Polymer Manufacturing Industry

X

X

EEE

(Reserved)

FFF

Flexible Vinyl and Urethane Coating and Printing

X

X

GGG

Equipment Leaks of VOC in Petroleum Refineries

X

X

HHH

Synthetic Fiber Production Facilities

X

X

III

Volatile Organic Compound (VOC) Emissions From the Synthetic Organic Chemical Manufacturing Industry (SOCMI) Air Oxidation Unit Processes

X

X

JJJ

Petroleum Dry Cleaners

X

X

KKK

Equipment Leaks of VOC From Onshore Natural Gas Processing Plants

X

X

LLL

Onshore Natural Gas Processing: SO2 Emissions

X

MMM

(Reserved)

NNN

Volatile Organic Compound (VOC) Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Distillation Operations

X

X

OOO

Nonmetallic Mineral Processing Plants

X

X

PPP

Wool Fiberglass Insulation Manufacturing Plants

X

X

QQQ

VOC Emissions From Petroleum Refinery Wastewater Systems

X

X

RRR

Volatile Organic Compound Emissions from Synthetic Organic Chemical Manufacturing Industry (SOCMI) Reactor Processes

X

SSS

Magnetic Tape Coating Facilities

X

X

TTT

Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines

X

X

UUU

Calciners and Dryers in Mineral Industries

X

X

VVV

Polymeric Coating of Supporting Substrates Facilities

X

X

WWW

Municipal Solid Waste Landfills

X

(iv) Delegations for Lake County Air Quality Management District, Lassen County Air Pollution Control District, Mariposa County Air Pollution Control District, and Mendocino County Air Pollution Control District are shown in the following table:

Delegation Status for New Source Performance Standards for Lake County Air Quality Management District, Lassen County Air Pollution Control District, Mariposa County Air Pollution Control District, and Mendocino County Air Pollution Control District

Subpart

Air pollution control agency

Lake County AQMD

Lassen County APCD

Mariposa County AQMD

Mendocino County AQMD

A

General Provisions

X

X

D

Fossil-Fuel Fired Steam Generators Constructed After August 17, 1971

X

X

Da

Electric Utility Steam Generating Units Constructed After September 18, 1978

X

X

Db

Industrial-Commercial-Institutional Steam Generating Units

X

Dc

Small Industrial Steam Generating Units

X

X

E

Incinerators

X

X

Ea

Municipal Waste Combustors Constructed After December 20, 1989 and On or Before September 20, 1994

X

X

Eb

Municipal Waste Combustors Constructed After September 20, 1994

Ec

Hospital/Medical/Infectious Waste Incinerators for Which Construction is Commenced After June 20, 1996

F

Portland Cement Plants

X

X

G

Nitric Acid Plants

X

X

H

Sulfuric Acid Plants

X

X

I

Hot Mix Asphalt Facilities

X

X

J

Petroleum Refineries

X

X

K

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After June 11, 1973, and Prior to May 19, 1978

X

X

Ka

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After May 18, 1978, and Prior to July 23, 1984

X

X

Kb

Volatile Organic Liquid Storage Vessels (Including Petroleum Liquid Storage Vessels) for Which Construction, Reconstruction, or Modification Commenced After July 23, 1984

X

X

L

Secondary Lead Smelters

X

X

M

Secondary Brass and Bronze Production Plants

X

X

N

Primary Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After June 11, 1973

X

X

Na

Secondary Emissions from Basic Oxygen Process Steelmaking Facilities for Which Construction is Commenced After January 20, 1983

X

X

O

Sewage Treatment Plants

X

X

P

Primary Copper Smelters

X

X

Q

Primary Zinc Smelters

X

X

R

Primary Lead Smelters

X

X

S

Primary Aluminum Reduction Plants

X

X

T

Phosphate Fertilizer Industry: Wet Process Phosphoric Acid Plants

X

X

U

Phosphate Fertilizer Industry: Superphosphoric Acid Plants

X

X

V

Phosphate Fertilizer Industry: Diammonium Phosphate Plants

X

X

W

Phosphate Fertilizer Industry: Triple Superphosphate Plants

X

X

X

Phosphate Fertilizer Industry: Granular Triple Superphosphate Storage Facilities

X

X

Y

Coal Preparation Plants

X

X

Z

Ferroalloy Production Facilities

X

X

AA

Steel Plants: Electric Arc Furnaces Constructed After October 21, 1974 and On or Before August 17, 1983

X

X

AAa

Steel Plants: Electric Arc Furnaces and Argon-Oxygen Decarburization Vessels Constructed After August 7, 1983

X

X

BB

Kraft Pulp Mills

X

X

CC

Glass Manufacturing Plants

X

X

DD

Grain Elevators

X

X

EE

Surface Coating of Metal Furniture

X

X

FF

(Reserved)

GG

Stationary Gas Turbines

X

X

HH

Lime Manufacturing Plants

X

X

KK

Lead-Acid Battery Manufacturing Plants

X

X

LL

Metallic Mineral Processing Plants

X

X

MM

Automobile and Light Duty Trucks Surface Coating Operations

X

X

NN

Phosphate Rock Plants

X

X

PP

Ammonium Sulfate Manufacture

X

X

QQ

Graphic Arts Industry: Publication Rotogravure Printing

X

X

RR

Pressure Sensitive Tape and Label Surface Coating Operations

X

X

SS

Industrial Surface Coating: Large Appliances

X

X

TT

Metal Coil Surface Coating

X

X

UU

Asphalt Processing and Asphalt Roofing Manufacture

X

X

VV

Equipment Leaks of VOC in the Synthetic Organic Chemicals Manufacturing Industry

X

X

WW

Beverage Can Surface Coating Industry

X

X

XX

Bulk Gasoline Terminals

AAA

New Residential Wool Heaters

X

X

BBB

Rubber Tire Manufacturing Industry

X

X

CCC

(Reserved)

DDD

Volatile Organic Compounds (VOC) Emissions from the Polymer Manufacturing Industry

X

X

EEE

(Reserved)

FFF

Flexible Vinyl and Urethane Coating and Printing

X

X

GGG

Equipment Leaks of VOC in Petroleum Refineries

X

X

HHH

Synthetic Fiber Production Facilities

X

X

III

Volatile Organic Compound (VOC) Emissions From the Synthetic Organic Chemical Manufacturing Industry (SOCMI) Air Oxidation Unit Processes

X

X

JJJ

Petroleum Dry Cleaners

X

X

KKK

Equipment Leaks of VOC From Onshore Natural Gas Processing Plants

X

X

LLL

Onshore Natural Gas Processing: SO2 Emissions

X

X

MMM

(Reserved)

NNN

Volatile Organic Compound (VOC) Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Distillation Operations

X

X

OOO

Nonmetallic Mineral Processing Plants

X

X

PPP

Wool Fiberglass Insulation Manufacturing Plants

X

X

QQQ

VOC Emissions From Petroleum Refinery Wastewater Systems

X

X

RRR

Volatile Organic Compound Emissions from Synthetic Organic Chemical Manufacturing Industry (SOCMI) Reactor Processes

X

SSS

Magnetic Tape Coating Facilities

X

X

TTT

Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines

UUU

Calciners and Dryers in Mineral Industries

X

X

VVV

Polymeric Coating of Supporting Substrates Facilities

X

X

WWW

Municipal Solid Waste Landfills

X

(v) Delegations for Modoc Air Pollution Control District, Mojave Desert Air Quality Management District, Monterey Bay Unified Air Pollution Control District and North Coast Unified Air Quality Management District are shown in the following table:

Table 7 to Paragraph (d)(2)(v) —Delegation Status for New Source Performance Standards for Modoc County APCD, Mojave Desert AQMD, Monterey Bay Unified APCD, and North Coast Unified AQMD

Subpart

Air pollution control agency

Modoc County APCD

Mojave Desert AQMD

Monterey Bay Unified APCD

North Coast Unified AQMD

A

General Provisions

X

X

X

X

D

Fossil-Fuel Fired Steam Generators Constructed After August 17, 1971

X

X

X

X

Da

Electric Utility Steam Generating Units Constructed After September 18, 1978

X

X

X

X

Db

Industrial-Commercial-Institutional Steam Generating Units

X

X

X

X

Dc

Small Industrial-Commercial-Institutional Steam Generating Units

X

X

E

Incinerators

X

X

X

X

Ea

Municipal Waste Combustors Constructed After December 20, 1989 and On or Before September 20, 1994

X

Eb

Large Municipal Waste Combustors Constructed After September 20, 1994

X

Ec

Hospital/Medical/Infectious Waste Incinerators for Which Construction is Commenced After June 20, 1996

X

F

Portland Cement Plants

X

X

X

X

G

Nitric Acid Plants

X

X

X

X

Ga

Nitric Acid Plants For Which Construction, Reconstruction or Modification Commenced After October 14, 2011

H

Sulfuric Acid Plant

X

X

X

X

I

Hot Mix Asphalt Facilities

X

X

X

X

J

Petroleum Refineries

X

X

X

X

Ja

Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After May 14, 2007

X

K

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After June 11, 1973, and Prior to May 19, 1978

X

X

X

X

Ka

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After May 18, 1978, and Prior to July 23, 1984

X

X

X

X

Kb

Volatile Organic Liquid Storage Vessels (Including Petroleum Liquid Storage Vessels) for Which Construction, Reconstruction, or Modification Commenced After July 23, 1984

X

X

X

X

L

Secondary Lead Smelters

X

X

X

X

M

Secondary Brass and Bronze Production Plants

X

X

X

X

N

Primary Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After June 11, 1973

X

X

X

X

Na

Secondary Emissions from Basic Oxygen Process Steelmaking Facilities for Which Construction is Commenced After January 20, 1983

X

X

X

X

O

Sewage Treatment Plants

X

X

X

X

P

Primary Copper Smelters

X

X

X

X

Q

Primary Zinc Smelters

X

X

X

X

R

Primary Lead Smelters

X

X

X

X

S

Primary Aluminum Reduction Plants

X

X

X

X

T

Phosphate Fertilizer Industry: Wet Process Phosphoric Acid Plants

X

X

X

X

U

Phosphate Fertilizer Industry: Superphosphoric Acid Plants

X

X

X

X

V

Phosphate Fertilizer Industry: Diammonium Phosphate Plants

X

X

X

X

W

Phosphate Fertilizer Industry: Triple Superphosphate Plants

X

X

X

X

X

Phosphate Fertilizer Industry: Granular Triple Superphosphate Storage Facilities

X

X

X

X

Y

Coal Preparation and Processing Plants

X

X

X

X

Z

Ferroalloy Production Facilities

X

X

X

X

AA

Steel Plants: Electric Arc Furnaces Constructed After October 21, 1974 and On or Before August 17, 1983

X

X

X

X

AAa

Steel Plants: Electric Arc Furnaces and Argon-Oxygen Decarburization Vessels Constructed After August 7, 1983

X

X

X

X

BB

Kraft Pulp Mills

X

X

X

X

CC

Glass Manufacturing Plants

X

X

X

X

DD

Grain Elevators

X

X

X

X

EE

Surface Coating of Metal Furniture

X

X

X

X

FF

(Reserved)

GG

Stationary Gas Turbines

X

X

X

X

HH

Lime Manufacturing Plants

X

X

X

X

KK

Lead-Acid Battery Manufacturing Plants

X

X

X

X

LL

Metallic Mineral Processing Plants

X

X

X

X

MM

Automobile and Light Duty Trucks Surface Coating Operations

X

X

X

X

NN

Phosphate Rock Plants

X

X

X

X

PP

Ammonium Sulfate Manufacture

X

X

X

X

QQ

Graphic Arts Industry: Publication Rotogravure Printing

X

X

X

X

RR

Pressure Sensitive Tape and Label Surface Coating Operations

X

X

X

X

SS

Industrial Surface Coating: Large Appliances

X

X

X

X

TT

Metal Coil Surface Coating

X

X

X

X

UU

Asphalt Processing and Asphalt Roofing Manufacture

X

X

X

X

VV

Equipment Leaks of VOC in the Synthetic Organic Industry Chemicals Manufacturing

X

X

X

X

VVa

Equipment Leaks of VOC in the Synthetic Organic Industry for Which Construction, Reconstruction, or Chemicals Manufacturing Modification Commenced After November 7, 2006

X

WW

Beverage Can Surface Coating Industry

X

X

X

X

XX

Bulk Gasoline Terminals

AAA

New Residential Wood Heaters

X

X

X

X

BBB

Rubber Tire Manufacturing Industry

X

X

X

X

CCC

(Reserved)

DDD

Volatile Organic Compounds (VOC) Emissions from the Polymer Manufacturing Industry

X

X

X

EEE

(Reserved)

FFF

Flexible Vinyl and Urethane Coating and Printing

X

X

X

X

GGG

Equipment Leaks of VOC in Petroleum Refineries

X

X

X

X

GGGa

Equipment Leaks of VOC in Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After November 7, 2006

X

HHH

Synthetic Fiber Production Facilities

X

X

X

X

III

Volatile Organic Compound (VOC) Emissions From the Synthetic Organic Chemical Manufacturing Industry (SOCMI) Air Oxidation Unit Processes

X

JJJ

Petroleum Dry Cleaners

X

X

X

X

KKK

Equipment Leaks of VOC From Onshore Natural Gas Processing Plants

X

X

X

X

LLL

Onshore Natural Gas Processing: SO 2 Emissions

X

X

X

X

MMM

(Reserved)

NNN

Volatile Organic Compound (VOC) Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Distillation Operations

X

X

X

OOO

Nonmetallic Mineral Processing Plants

X

X

X

X

PPP

Wool Fiberglass Insulation Manufacturing Plants

X

X

X

X

QQQ

VOC Emissions From Petroleum Refinery Wastewater Systems

X

X

X

X

RRR

Volatile Organic Compound Emissions from Synthetic Organic Chemical Manufacturing Industry (SOCMI) Reactor Processes

X

SSS

Magnetic Tape Coating Facilities

X

X

X

X

TTT

Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines

X

X

X

X

UUU

Calciners and Dryers in Mineral Industries

X

X

VVV

Polymeric Coating of Supporting Substrates Facilities

X

X

X

WWW

Municipal Solid Waste Landfills

X

X

AAAA

Small Municipal Waste Combustion Units for Which Construction is Commenced After August 30, 1999 or for Which Modification or Reconstruction is Commended After June 6, 2001

X

CCCC

Commercial and Industrial Solid Waste Incineration Units for Which Construction Is Commenced After November 30, 1999 or for Which Modification or Reconstruction Is Commenced on or After June 1, 2001

X

EEEE

Other Solid Waste Incineration Units for Which Construction is Commenced After December 9, 2004, or for Which Modification or Reconstruction is Commenced on or After June 16, 2006

X

GGGG

(Reserved)

HHHH

(Reserved)

IIII

Stationary Compression Ignition Internal Combustion Engines

X

X

JJJJ

Stationary Spark Ignition Internal Combustion Engines

X

X

KKKK

Stationary Combustion Turbines

X

X

LLLL

New Sewage Sludge Incineration Units

OOOO

Crude Oil and Natural Gas Production, Transmission, and Distribution

(vi) Delegations for Northern Sierra Air Quality Management District, Northern Sonoma County Air Pollution Control District, Placer County Air Pollution Control District, and Sacramento Metropolitan Air Quality Management District are shown in the following table:

Delegation Status for New Source Performance Standards for Northern Sierra Air Quality Management District, Northern Sonoma County Air Pollution Control District, Placer County Air Pollution Control District, and Sacramento Metropolitan Air Quality Management District

Subpart

Air pollution control agency

Northern Sierra AQMD

Northern Sonoma County APCD

Placer County APCD

Sacramento Metropolitan AQMD

A

General Provisions

X

X

D

Fossil-Fuel Fired Steam Generators Constructed After August 17, 1971

X

X

Da

Electric Utility Steam Generating Units Constructed After September 18, 1978

X

X

Db

Industrial-Commercial-Institutional Steam Generating Units

X

Dc

Small Industrial Steam Generating Units

X

E

Incinerators

X

X

Ea

Municipal Waste Combustors Constructed After December 20, 1989 and On or Before September 20, 1994

X

Eb

Municipal Waste Combustors Constructed After September 20, 1994

X

Ec

Hospital/Medical/Infectious Waste Incinerators for Which Construction is Commenced After June 20, 1996

X

F

Portland Cement Plants

X

X

G

Nitric Acid Plants

X

X

H

Sulfuric Acid Plants

X

X

I

Hot Mix Asphalt Facilities

X

X

J

Petroleum Refineries

X

X

K

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After June 11, 1973, and Prior to May 19, 1978

X

X

Ka

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After May 18, 1978, and Prior to July 23, 1984

X

X

Kb

Volatile Organic Liquid Storage Vessels (Including Petroleum Liquid Storage Vessels) for Which Construction, Reconstruction, or Modification Commenced After July 23, 1984

X

L

Secondary Lead Smelters

X

X

M

Secondary Brass and Bronze Production Plants

X

X

N

Primary Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After June 11, 1973

X

X

Na

Secondary Emissions from Basic Oxygen Process Steelmaking Facilities for Which Construction is Commenced After January 20, 1983

X

O

Sewage Treatment Plants

X

X

P

Primary Copper Smelters

X

X

Q

Primary Zinc Smelters

X

X

R

Primary Lead Smelters

X

X

S

Primary Aluminum Reduction Plants

X

X

T

Phosphate Fertilizer Industry: Wet Process Phosphoric Acid Plants

X

X

U

Phosphate Fertilizer Industry: Superphosphoric Acid Plants

X

X

V

Phosphate Fertilizer Industry: Diammonium Phosphate Plants

X

X

W

Phosphate Fertilizer Industry: Triple Superphosphate Plants

X

X

X

Phosphate Fertilizer Industry: Granular Triple Superphosphate Storage Facilities

X

X

Y

Coal Preparation Plants

X

X

Z

Ferroalloy Production Facilities

X

X

AA

Steel Plants: Electric Arc Furnaces Constructed After October 21, 1974 and On or Before August 17, 1983

X

X

AAa

Steel Plants: Electric Arc Furnaces and Argon-Oxygen Decarburization Vessels Constructed After August 7, 1983

X

BB

Kraft pulp Mills

X

X

CC

Glass Manufacturing Plants

X

X

DD

Grain Elevators

X

X

EE

Surface Coating of Metal Furniture

X

FF

(Reserved)

GG

Stationary Gas Turbines

X

X

HH

Lime Manufacturing Plants

X

X

KK

Lead-Acid Battery Manufacturing Plants

X

LL

Metallic Mineral Processing Plants

X

MM

Automobile and Light Duty Trucks Surface Coating Operations

X

X

NN

Phosphate Rock Plants

X

PP

Ammonium Sulfate Manufacture

X

X

QQ

Graphic Arts Industry: Publication Rotogravure Printing

X

RR

Pressure Sensitive Tape and Label Surface Coating Operations

X

SS

Industrial Surface Coating: Large Appliances

X

TT

Metal Coil Surface Coating

X

UU

Asphalt Processing and Asphalt Roofing Manufacture

X

VV

Equipment Leaks of VOC in the Synthetic Organic Chemicals Manufacturing Industry

X

WW

Beverage Can Surface Coating Industry

X

XX

Bulk Gasoline Terminals

AAA

New Residential Wool Heaters

X

BBB

Rubber Tire Manufacturing Industry

X

CCC

(Reserved)

DDD

Volatile Organic Compounds (VOC) Emissions from the Polymer Manufacturing Industry

X

EEE

(Reserved)

FFF

Flexible Vinyl and Urethane Coating and Printing

X

GGG

Equipment Leaks of VOC in Petroleum Refineries

X

HHH

Synthetic Fiber Production Facilities

X

III

Volatile Organic Compound (VOC) Emissions From the Synthetic Organic Chemical Manufacturing Industry (SOCMI) Air Oxidation Unit Processes

X

JJJ

Petroleum Dry Cleaners

X

KKK

Equipment Leaks of VOC From Onshore Natural Gas Processing Plants

X

LLL

Onshore Natural Gas Processing: SO2 Emissions

X

MMM

(Reserved)

NNN

Volatile Organic Compound (VOC) Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Distillation Operations

X

OOO

Nonmetallic Mineral Processing Plants

X

PPP

Wool Fiberglass Insulation Manufacturing Plants

X

QQQ

VOC Emissions From Petroleum Refinery Wastewater Systems

X

RRR

Volatile Organic Compound Emissions from Synthetic Organic Chemical Manufacturing Industry (SOCMI) Reactor Processes

X

SSS

Magnetic Tape Coating Facilities

X

TTT

Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines

X

UUU

Calciners and Dryers in Mineral Industries

X

VVV

Polymeric Coating of Supporting Substrates Facilities

X

WWW

Municipal Solid Waste Landfills

X

(vii) Delegations for San Diego County Air Pollution Control District, San Joaquin Valley Unified Air Pollution Control District, San Luis Obispo County Air Pollution Control District, and Santa Barbara County Air Pollution Control District are shown in the following table:

Table 9 to Paragraph (d)(2)(vii) —Delegation Status for New Source Performance Standards for San Diego County APCD, San Joaquin Valley Unified APCD, San Luis Obispo County APCD, and Santa Barbara County APCD

Subpart

Air pollution control agency

San Diego County APCD

San Joaquin Valley Unified APCD

San Luis Obispo County APCD

Santa Barbara County APCD

A

General Provisions

X

X

X

X

D

Fossil-Fuel Fired Steam Generators Constructed After August 17, 1971

X

X

X

X

Da

Electric Utility Steam Generating Units Constructed After September 18, 1978

X

X

X

X

Db

Industrial-Commercial-Institutional Steam Generating Units

X

X

X

X

Dc

Small Industrial-Commercial-Institutional Steam Generating Units

X

X

X

X

E

Incinerators

X

X

X

X

Ea

Municipal Waste Combustors Constructed After December 20, 1989 and On or Before September 20, 1994

X

X

X

Eb

Large Municipal Waste Combustors Constructed After September 20, 1994

X

X

X

Ec

Hospital/Medical/Infectious Waste Incinerators for Which Construction is Commenced After June 20, 1996

X

X

F

Portland Cement Plants

X

X

X

G

Nitric Acid Plants

X

X

X

Ga

Nitric Acid Plants For Which Construction, Reconstruction or Modification Commenced After October 14, 2011

H

Sulfuric Acid Plant

X

X

X

I

Hot Mix Asphalt Facilities

X

X

X

X

J

Petroleum Refineries

X

X

X

X

Ja

Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After May 14, 2007

X

K

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After June 11, 1973, and Prior to May 19, 1978

X

X

X

X

Ka

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After May 18, 1978, and Prior to July 23, 1984

X

X

X

X

Kb

Volatile Organic Liquid Storage Vessels (Including Petroleum Liquid Storage Vessels) for Which Construction, Reconstruction, or Modification Commenced After July 23, 1984

X

X

X

X

L

Secondary Lead Smelters

X

X

X

X

M

Secondary Brass and Bronze Production Plants

X

X

X

X

N

Primary Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After June 11, 1973

X

X

X

Na

Secondary Emissions from Basic Oxygen Process Steelmaking Facilities for Which Construction is Commenced After January 20, 1983

X

X

X

O

Sewage Treatment Plants

X

X

X

X

P

Primary Copper Smelters

X

X

X

Q

Primary Zinc Smelters

X

X

X

R

Primary Lead Smelters

X

X

X

S

Primary Aluminum Reduction Plants

X

X

X

T

Phosphate Fertilizer Industry: Wet Process Phosphoric Acid Plants

X

X

X

U

Phosphate Fertilizer Industry: Superphosphoric Acid Plants

X

X

X

V

Phosphate Fertilizer Industry: Diammonium Phosphate Plants

X

X

X

W

Phosphate Fertilizer Industry: Triple Superphosphate Plants

X

X

X

X

Phosphate Fertilizer Industry: Granular Triple Superphosphate Storage Facilities

X

X

X

Y

Coal Preparation and Processing Plants

X

X

X

Z

Ferroalloy Production Facilities

X

X

X

AA

Steel Plants: Electric Arc Furnaces Constructed After October 21, 1974 and On or Before August 17, 1983

X

X

X

AAa

Steel Plants: Electric Arc Furnaces and Argon-Oxygen Decarburization Vessels Constructed After August 7, 1983

X

X

X

BB

Kraft Pulp Mills

X

X

X

CC

Glass Manufacturing Plants

X

X

X

X

DD

Grain Elevators

X

X

X

X

EE

Surface Coating of Metal Furniture

X

X

X

FF

(Reserved)

GG

Stationary Gas Turbines

X

X

X

X

HH

Lime Manufacturing Plants

X

X

X

KK

Lead-Acid Battery Manufacturing Plants

X

X

X

LL

Metallic Mineral Processing Plants

X

X

X

MM

Automobile and Light Duty Trucks Surface Coating Operations

X

X

X

NN

Phosphate Rock Plants

X

X

X

PP

Ammonium Sulfate Manufacture

X

X

X

QQ

Graphic Arts Industry: Publication Rotogravure Printing

X

X

X

RR

Pressure Sensitive Tape and Label Surface Coating Operations

X

X

X

SS

Industrial Surface Coating: Large Appliances

X

X

X

TT

Metal Coil Surface Coating

X

X

X

UU

Asphalt Processing and Asphalt Roofing Manufacture

X

X

X

VV

Equipment Leaks of VOC in the Synthetic Organic Industry Chemicals Manufacturing

X

X

X

VVa

Equipment Leaks of VOC in the Synthetic Organic Industry for Which Construction, Reconstruction, or Chemicals Manufacturing Modification Commenced After November 7, 2006

X

WW

Beverage Can Surface Coating Industry

X

X

X

XX

Bulk Gasoline Terminals

AAA

New Residential Wood Heaters

X

X

X

X

BBB

Rubber Tire Manufacturing Industry

X

X

X

CCC

(Reserved)

DDD

Volatile Organic Compounds (VOC) Emissions from the Polymer Manufacturing Industry

X

X

EEE

(Reserved)

FFF

Flexible Vinyl and Urethane Coating and Printing

X

X

X

GGG

Equipment Leaks of VOC in Petroleum Refineries

X

X

X

GGGa

Equipment Leaks of VOC in Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After November 7, 2006

X

HHH

Synthetic Fiber Production Facilities

X

X

X

III

Volatile Organic Compound (VOC) Emissions From the Synthetic Organic Chemical Manufacturing Industry (SOCMI) Air Oxidation Unit Processes

X

X

JJJ

Petroleum Dry Cleaners

X

X

X

KKK

Equipment Leaks of VOC From Onshore Natural Gas Processing Plants

X

X

X

LLL

Onshore Natural Gas Processing: SO 2 Emissions

X

X

X

MMM

(Reserved)

NNN

Volatile Organic Compound (VOC) Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Distillation Operations

X

X

OOO

Nonmetallic Mineral Processing Plants

X

X

X

X

PPP

Wool Fiberglass Insulation Manufacturing Plants

X

X

X

QQQ

VOC Emissions From Petroleum Refinery Wastewater Systems

X

X

X

RRR

Volatile Organic Compound Emissions from Synthetic Organic Chemical Manufacturing Industry (SOCMI) Reactor Processes

X

X

X

SSS

Magnetic Tape Coating Facilities

X

X

X

TTT

Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines

X

X

X

UUU

Calciners and Dryers in Mineral Industries

X

X

X

X

VVV

Polymeric Coating of Supporting Substrates Facilities

X

X

X

X

WWW

Municipal Solid Waste Landfills

X

X

X

X

AAAA

Small Municipal Waste Combustion Units for Which Construction is Commenced After August 30, 1999 or for Which Modification or Reconstruction is Commended After June 6, 2001

X

X

CCCC

Commercial and Industrial Solid Waste Incineration Units for Which Construction Is Commenced After November 30, 1999 or for Which Modification or Reconstruction Is Commenced on or After June 1, 2001

X

X

EEEE

Other Solid Waste Incineration Units for Which Construction is Commenced After December 9, 2004, or for Which Modification or Reconstruction is Commenced on or After June 16, 2006

X

X

GGGG

(Reserved)

HHHH

(Reserved)

IIII

Stationary Compression Ignition Internal Combustion Engines

X

X

JJJJ

Stationary Spark Ignition Internal Combustion Engines

X

X

KKKK

Stationary Combustion Turbines

X

X

LLLL

New Sewage Sludge Incineration Units

OOOO

Crude Oil and Natural Gas Production, Transmission, and Distribution

QQQQ

Standards of Performance for New Residential Hydronic Heaters and Forced-Air Furnaces

X

TTTT

Standards of Performance for Greenhouse Gas Emissions for Electric Generating Units

X

(viii) Delegations for Shasta County Air Quality Management District, Siskiyou County Air Pollution Control District, South Coast Air Quality Management District, and Tehama County Air Pollution Control District are shown in the following table:

Delegation Status for New Source Performance Standards for Shasta County AQMD, Siskiyou County APCD, South Coast AQMD, and Tehama County APCD

Subpart

Air pollution control agency

Shasta County AQMD

Siskiyou County APCD

South Coast AQMD

Tehama County APCD

A

General Provisions

X

X

X

D

Fossil-Fuel Fired Steam Generators Constructed After August 17, 1971

X

X

Da

Electric Utility Steam Generating Units Constructed After September 18, 1978

X

Db

Industrial-Commercial-Institutional Steam Generating Units

X

Dc

Small Industrial-Commercial-Institutional Steam Generating Units

X

E

Incinerators

X

X

Ea

Municipal Waste Combustors Constructed After December 20, 1989 and On or Before September 20, 1994

X

Eb

Large Municipal Waste Combustors Constructed After September 20, 1994

X

Ec

Hospital/Medical/Infectious Waste Incinerators for Which Construction is Commenced After June 20, 1996

X

F

Portland Cement Plants

X

X

G

Nitric Acid Plants

X

X

Ga

Nitric Acid Plants For Which Construction, Reconstruction or Modification Commenced After October 14, 2011

H

Sulfuric Acid Plant

X

X

I

Hot Mix Asphalt Facilities

X

X

J

Petroleum Refineries

X

X

Ja

Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After May 14, 2007

X

K

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After June 11, 1973, and Prior to May 19, 1978

X

X

Ka

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After May 18, 1978, and Prior to July 23, 1984

X

Kb

Volatile Organic Liquid Storage Vessels (Including Petroleum Liquid Storage Vessels) for Which Construction, Reconstruction, or Modification Commenced After July 23, 1984

X

L

Secondary Lead Smelters

X

X

M

Secondary Brass and Bronze Production Plants

X

X

N

Primary Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After June 11, 1973

X

X

Na

Secondary Emissions from Basic Oxygen Process Steelmaking Facilities for Which Construction is Commenced After January 20, 1983

X

O

Sewage Treatment Plants

X

X

P

Primary Copper Smelters

X

X

Q

Primary Zinc Smelters

X

X

R

Primary Lead Smelters

X

X

S

Primary Aluminum Reduction Plants

X

X

T

Phosphate Fertilizer Industry: Wet Process Phosphoric Acid Plants

X

X

U

Phosphate Fertilizer Industry: Superphosphoric Acid Plants

X

X

V

Phosphate Fertilizer Industry: Diammonium Phosphate Plants

X

X

W

Phosphate Fertilizer Industry: Triple Superphosphate Plants

X

X

X

Phosphate Fertilizer Industry: Granular Triple Superphosphate Storage Facilities

X

X

Y

Coal Preparation and Processing Plants

X

X

Z

Ferroalloy Production Facilities

X

X

AA

Steel Plants: Electric Arc Furnaces Constructed After October 21, 1974 and On or Before August 17, 1983

X

X

AAa

Steel Plants: Electric Arc Furnaces and Argon-Oxygen Decarburization Vessels Constructed After August 7, 1983

X

BB

Kraft Pulp Mills

X

X

CC

Glass Manufacturing Plants

X

DD

Grain Elevators

X

X

EE

Surface Coating of Metal Furniture

X

FF

(Reserved)

GG

Stationary Gas Turbines

X

HH

Lime Manufacturing Plants

X

X

KK

Lead-Acid Battery Manufacturing Plants

X

LL

Metallic Mineral Processing Plants

X

MM

Automobile and Light Duty Trucks Surface Coating Operations

X

NN

Phosphate Rock Plants

X

PP

Ammonium Sulfate Manufacture

X

QQ

Graphic Arts Industry: Publication Rotogravure Printing

X

RR

Pressure Sensitive Tape and Label Surface Coating Operations

X

SS

Industrial Surface Coating: Large Appliances

X

TT

Metal Coil Surface Coating

X

UU

Asphalt Processing and Asphalt Roofing Manufacture

X

VV

Equipment Leaks of VOC in the Synthetic Organic Industry Chemicals Manufacturing

X

VVa

Equipment Leaks of VOC in the Synthetic Organic Industry for Which Construction, Reconstruction, or Chemicals Manufacturing Modification Commenced After November 7, 2006

X

WW

Beverage Can Surface Coating Industry

X

XX

Bulk Gasoline Terminals

AAA

New Residential Wood Heaters

X

X

BBB

Rubber Tire Manufacturing Industry

X

X

CCC

(Reserved)

DDD

Volatile Organic Compounds (VOC) Emissions from the Polymer Manufacturing Industry

X

EEE

(Reserved)

FFF

Flexible Vinyl and Urethane Coating and Printing

X

GGG

Equipment Leaks of VOC in Petroleum Refineries

X

GGGa

Equipment Leaks of VOC in Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After November 7, 2006

X

HHH

Synthetic Fiber Production Facilities

X

III

Volatile Organic Compound (VOC) Emissions From the Synthetic Organic Chemical Manufacturing Industry (SOCMI) Air Oxidation Unit Processes

X

JJJ

Petroleum Dry Cleaners

X

KKK

Equipment Leaks of VOC From Onshore Natural Gas Processing Plants

X

LLL

Onshore Natural Gas Processing: SO 2 Emissions

X

MMM

(Reserved)

NNN

Volatile Organic Compound (VOC) Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Distillation Operations

X

OOO

Nonmetallic Mineral Processing Plants

X

PPP

Wool Fiberglass Insulation Manufacturing Plants

X

QQQ

VOC Emissions From Petroleum Refinery Wastewater Systems

X

X

RRR

Volatile Organic Compound Emissions from Synthetic Organic Chemical Manufacturing Industry (SOCMI) Reactor Processes

X

SSS

Magnetic Tape Coating Facilities

X

X

TTT

Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines

X

X

UUU

Calciners and Dryers in Mineral Industries

X

VVV

Polymeric Coating of Supporting Substrates Facilities

X

WWW

Municipal Solid Waste Landfills

X

AAAA

Small Municipal Waste Combustion Units for Which Construction is Commenced After August 30, 1999 or for Which Modification or Reconstruction is Commended After June 6, 2001

X

X

X

CCCC

Commercial and Industrial Solid Waste Incineration Units for Which Construction Is Commenced After November 30, 1999 or for Which Modification or Reconstruction Is Commenced on or After June 1, 2001

X

EEEE

Other Solid Waste Incineration Units for Which Construction is Commenced After December 9, 2004, or for Which Modification or Reconstruction is Commenced on or After June 16, 2006

X

GGGG

(Reserved)

HHHH

(Reserved)

IIII

Stationary Compression Ignition Internal Combustion Engines

X

JJJJ

Stationary Spark Ignition Internal Combustion Engines

X

KKKK

Stationary Combustion Turbines

X

LLLL

New Sewage Sludge Incineration Units

OOOO

Crude Oil and Natural Gas Production, Transmission, and Distribution

(ix) Delegations for Tuolumne County Air Pollution Control District, Ventura County Air Pollution Control District, and Yolo-Solano Air Quality Management District are shown in the following table:

Table 11 to Paragraph (d)(2)(ix) —Delegation Status for New Source Performance Standards for Tuolumne County APCD, Ventura County APCD, and Yolo-Solano AQMD

Subpart

Air pollution control agency

Tuolumne County APCD

Ventura County APCD

Yolo- Solano AQMD

A

General Provisions

X

X

D

Fossil-Fuel Fired Steam Generators Constructed After August 17, 1971

X

X

Da

Electric Utility Steam Generating Units Constructed After September 18, 1978

X

Db

Industrial-Commercial-Institutional Steam Generating Units

X

X

Dc

Small Industrial-Commercial-Institutional Steam Generating Units

X

E

Incinerators

X

Ea

Municipal Waste Combustors Constructed After December 20, 1989 and On or Before September 20, 1994

X

Eb

Large Municipal Waste Combustors Constructed After September 20, 1994

Ec

Hospital/Medical/Infectious Waste Incinerators for Which Construction is Commenced After June 20, 1996

F

Portland Cement Plants

X

G

Nitric Acid Plants

X

H

Sulfuric Acid Plant

X

I

Hot Mix Asphalt Facilities

X

X

J

Petroleum Refineries

X

X

K

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After June 11, 1973, and Prior to May 19, 1978

X

X

Ka

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After May 18, 1978, and Prior to July 23, 1984

X

Kb

Volatile Organic Liquid Storage Vessels (Including Petroleum Liquid Storage Vessels) for Which Construction, Reconstruction, or Modification Commenced After July 23, 1984

X

L

Secondary Lead Smelters

X

M

Secondary Brass and Bronze Production Plants

X

N

Primary Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After June 11, 1973

X

Na

Secondary Emissions from Basic Oxygen Process Steelmaking Facilities for Which Construction is Commenced After January 20, 1983

X

O

Sewage Treatment Plants

X

P

Primary Copper Smelters

X

Q

Primary Zinc Smelters

X

R

Primary Lead Smelters

X

S

Primary Aluminum Reduction Plants

X

T

Phosphate Fertilizer Industry: Wet Process Phosphoric Acid Plants

X

U

Phosphate Fertilizer Industry: Superphosphoric Acid Plants

X

V

Phosphate Fertilizer Industry: Diammonium Phosphate Plants

X

W

Phosphate Fertilizer Industry: Triple Superphosphate Plants

X

X

Phosphate Fertilizer Industry: Granular Triple Superphosphate Storage Facilities

X

Y

Coal Preparation and Processing Plants

X

Z

Ferroalloy Production Facilities

X

AA

Steel Plants: Electric Arc Furnaces Constructed After October 21, 1974 and On or Before August 17, 1983

X

X

AAa

Steel Plants: Electric Arc Furnaces and Argon-Oxygen Decarburization Vessels Constructed After August 7, 1983

X

BB

Kraft Pulp Mills

X

CC

Glass Manufacturing Plants

X

DD

Grain Elevators

X

EE

Surface Coating of Metal Furniture

X

FF

(Reserved)

GG

Stationary Gas Turbines

X

HH

Lime Manufacturing Plants

X

KK

Lead-Acid Battery Manufacturing Plants

X

LL

Metallic Mineral Processing Plants

X

MM

Automobile and Light Duty Trucks Surface Coating Operations

X

NN

Phosphate Rock Plants

X

PP

Ammonium Sulfate Manufacture

X

QQ

Graphic Arts Industry: Publication Rotogravure Printing

X

RR

Pressure Sensitive Tape and Label Surface Coating Operations

X

SS

Industrial Surface Coating: Large Appliances

X

TT

Metal Coil Surface Coating

X

UU

Asphalt Processing and Asphalt Roofing Manufacture

X

VV

Equipment Leaks of VOC in the Synthetic Organic Industry Chemicals Manufacturing

X

WW

Beverage Can Surface Coating Industry

X

XX

Bulk Gasoline Terminals

AAA

New Residential Wood Heaters

X

BBB

Rubber Tire Manufacturing Industry

X

CCC

(Reserved)

DDD

Volatile Organic Compounds (VOC) Emissions from the Polymer Manufacturing Industry

X

EEE

(Reserved)

FFF

Flexible Vinyl and Urethane Coating and Printing

X

GGG

Equipment Leaks of VOC in Petroleum Refineries

X

GGGa

Equipment Leaks of VOC in Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After November 7, 2006

HHH

Synthetic Fiber Production Facilities

X

III

Volatile Organic Compound (VOC) Emissions From the Synthetic Organic Chemical Manufacturing Industry (SOCMI) Air Oxidation Unit Processes

X

JJJ

Petroleum Dry Cleaners

X

KKK

Equipment Leaks of VOC From Onshore Natural Gas Processing Plants

X

LLL

Onshore Natural Gas Processing: SO 2 Emissions

X

MMM

(Reserved)

NNN

Volatile Organic Compound (VOC) Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Distillation Operations

X

OOO

Nonmetallic Mineral Processing Plants

X

X

PPP

Wool Fiberglass Insulation Manufacturing Plants

X

QQQ

VOC Emissions From Petroleum Refinery Wastewater Systems

X

RRR

Volatile Organic Compound Emissions from Synthetic Organic Chemical Manufacturing Industry (SOCMI) Reactor Processes

X

SSS

Magnetic Tape Coating Facilities

X

TTT

Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines

X

UUU

Calciners and Dryers in Mineral Industries

X

VVV

Polymeric Coating of Supporting Substrates Facilities

X

WWW

Municipal Solid Waste Landfills

X

X

(3) Hawaii. The following table identifies delegations for Hawaii:

Delegation Status for New Source Performance Standards for Hawaii:

Delegation Status for New Source Performance Standards for Hawaii

Subpart

Hawaii

A

General Provisions

X

D

Fossil-Fuel Fired Steam Generators Constructed After August 17, 1971

X

Da

Electric Utility Steam Generating Units Constructed After September 18, 1978

X

Db

Industrial-Commercial-Institutional Steam Generating Units

X

Dc

Small Industrial Steam Generating Units

X

E

Incinerators

X

Ea

Municipal Waste Combustors Constructed After December 20, 1989 and On or Before September 20, 1994

X

Eb

Municipal Waste Combustors Constructed After September 20, 1994

X

Ec

Hospital/Medical/Infectious Waste Incinerators for Which Construction is Commenced After June 20, 1996

X

F

Portland Cement Plants

X

G

Nitric Acid Plants

H

Sulfuric Acid Plants

I

Hot Mix Asphalt Facilities

X

J

Petroleum Refineries

X

Ja

Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After May 14, 2007

K

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After June 11, 1973, and Prior to May 19, 1978

X

Ka

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After May 18, 1978, and Prior to July 23, 1984

X

Kb

Volatile Organic Liquid Storage Vessels (Including Petroleum Liquid Storage Vessels) for Which Construction, Reconstruction, or Modification Commenced After July 23, 1984

X

L

Secondary Lead Smelters

M

Secondary Brass and Bronze Production Plants

N

Primary Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After June 11, 1973

Na

Secondary Emissions from Basic Oxygen Process Steelmaking Facilities for Which Construction is Commenced After January 20, 1983

O

Sewage Treatment Plants

X

P

Primary Copper Smelters

Q

Primary Zinc Smelters

R

Primary Lead Smelters

S

Primary Aluminum Reduction Plants

T

Phosphate Fertilizer Industry: Wet Process Phosphoric Acid Plants

U

Phosphate Fertilizer Industry: Superphosphoric Acid Plants

V

Phosphate Fertilizer Industry: Diammonium Phosphate Plants

W

Phosphate Fertilizer Industry: Triple Superphosphate Plants

X

Phosphate Fertilizer Industry: Granular Triple Superphosphate Storage Facilities

Y

Coal Preparation Plants

X

Z

Ferroalloy Production Facilities

AA

Steel Plants: Electric Arc Furnaces Constructed After October 21, 1974 and On or Before August 17, 1983

X

AAa

Steel Plants: Electric Arc Furnaces and Argon-Oxygen Decarburization Vessels Constructed After August 7, 1983

X

BB

Kraft pulp Mills

CC

Glass Manufacturing Plants

DD

Grain Elevators

EE

Surface Coating of Metal Furniture

FF

(Reserved)

GG

Stationary Gas Turbines

X

HH

Lime Manufacturing Plants

KK

Lead-Acid Battery Manufacturing Plants

LL

Metallic Mineral Processing Plants

MM

Automobile and Light Duty Trucks Surface Coating Operations

NN

Phosphate Rock Plants

PP

Ammonium Sulfate Manufacture

QQ

Graphic Arts Industry: Publication Rotogravure Printing

RR

Pressure Sensitive Tape and Label Surface Coating Operations

SS

Industrial Surface Coating: Large Appliances

TT

Metal Coil Surface Coating

UU

Asphalt Processing and Asphalt Roofing Manufacture

VV

Equipment Leaks of VOC in the Synthetic Organic Chemicals Manufacturing Industry

X

VVa

Equipment Leaks of VOC in the Synthetic Organic Chemicals Manufacturing Industry for Which Construction, Reconstruction, or Modification Commenced After November 7, 2006

WW

Beverage Can Surface Coating Industry

X

XX

Bulk Gasoline Terminals

X

AAA

New Residential Wool Heaters

BBB

Rubber Tire Manufacturing Industry

CCC

(Reserved)

DDD

Volatile Organic Compounds (VOC) Emissions from the Polymer Manufacturing Industry

EEE

(Reserved)

FFF

Flexible Vinyl and Urethane Coating and Printing

GGG

Equipment Leaks of VOC in Petroleum Refineries

X

GGGa

Equipment Leaks of VOC in Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After November 7, 2006

HHH

Synthetic Fiber Production Facilities

III

Volatile Organic Compound (VOC) Emissions From the Synthetic Organic Chemical Manufacturing Industry (SOCMI) Air Oxidation Unit Processes

JJJ

Petroleum Dry Cleaners

X

KKK

Equipment Leaks of VOC From Onshore Natural Gas Processing Plants

LLL

Onshore Natural Gas Processing: SO2 Emissions

MMM

(Reserved)

NNN

Volatile Organic Compound (VOC) Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Distillation Operations

X

OOO

Nonmetallic Mineral Processing Plants

X

PPP

Wool Fiberglass Insulation Manufacturing Plants

QQQ

VOC Emissions From Petroleum Refinery Wastewater

X

RRR

Volatile Organic Compound Emissions from Synthetic Organic Chemical Manufacturing Industry (SOCMI) Reactor Processes

SSS

Magnetic Tape Coating Facilities

TTT

Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines

UUU

Calciners and Dryers in Mineral Industries

X

VVV

Polymeric Coating of Supporting Substrates Facilities

X

WWW

Municipal Solid Waste Landfills

X

AAAA

Small Municipal Waste Combustion Units for Which Construction is Commenced After August 30, 1999 or for Which Modification or Reconstruction is Commenced After June 6, 2001

X

CCCC

Commercial and Industrial Solid Waste Incineration Units for Which Construction Is Commenced After November 30, 1999 or for Which Modification or Reconstruction Is Commenced on or After June 1, 2001

X

EEEE

Other Solid Waste Incineration Units for Which Construction is Commenced After December 9, 2004, or for Which Modification or Reconstruction is Commenced on or After June 16, 2006

GGGG

(Reserved)

IIII

Stationary Compression Ignition Internal Combustion Engines

JJJJ

Stationary Spark Ignition Internal Combustion Engines

KKKK

Stationary Combustion Turbines

(4) Nevada. The following table identifies delegations for Nevada:

Table 12 to Paragraph ( d )(4)—Delegation Status for New Source Performance Standards for Nevada

Subpart

Air pollution control agency

Nevada DEP

Clark County

Washoe County

A

General Provisions

X

X

X

Cf

Emission Guidelines and Compliance Times for Municipal Solid Waste Landfills

X

D

Fossil-Fuel Fired Steam Generators Constructed After August 17, 1971

X

X

X

Da

Electric Utility Steam Generating Units Constructed After September 18, 1978

X

X

Db

Industrial-Commercial-Institutional Steam Generating Units

X

X

Dc

Small Industrial-Commercial-Institutional Steam Generating Units

X

X

E

Incinerators

X

X

X

Ea

Municipal Waste Combustors Constructed After December 20, 1989 and On or Before September 20, 1994

X

X

Eb

Large Municipal Waste Combustors Constructed After September 20, 1994

X

X

Ec

Hospital/Medical/Infectious Waste Incinerators for Which Construction is Commenced After June 20, 1996

X

X

F

Portland Cement Plants

X

X

X

G

Nitric Acid Plants

X

X

Ga

Nitric Acid Plants For Which Construction, Reconstruction or Modification Commenced After October 14, 2011

X

H

Sulfuric Acid Plant

X

X

I

Hot Mix Asphalt Facilities

X

X

X

J

Petroleum Refineries

X

X

Ja

Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After May 14, 2007

X

K

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After June 11, 1973, and Prior to May 19, 1978

X

X

X

Ka

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After May 18, 1978, and Prior to July 23, 1984

X

X

X

Kb

Volatile Organic Liquid Storage Vessels (Including Petroleum Liquid Storage Vessels) for Which Construction, Reconstruction, or Modification Commenced After July 23, 1984

X

X

L

Secondary Lead Smelters

X

X

X

M

Secondary Brass and Bronze Production Plants

X

X

N

Primary Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After June 11, 1973

X

X

Na

Secondary Emissions from Basic Oxygen Process Steelmaking Facilities for Which Construction is Commenced After January 20, 1983

X

X

O

Sewage Treatment Plants

X

X

X

P

Primary Copper Smelters

X

X

X

Q

Primary Zinc Smelters

X

X

X

R

Primary Lead Smelters

X

X

X

S

Primary Aluminum Reduction Plants

X

X

T

Phosphate Fertilizer Industry: Wet Process Phosphoric Acid Plants

X

U

Phosphate Fertilizer Industry: Superphosphoric Acid Plants

X

V

Phosphate Fertilizer Industry: Diammonium Phosphate Plants

X

W

Phosphate Fertilizer Industry: Triple Superphosphate Plants

X

X

Phosphate Fertilizer Industry: Granular Triple Superphosphate Storage Facilities

X

Y

Coal Preparation and Processing Plants

X

X

X

Z

Ferroalloy Production Facilities

X

X

AA

Steel Plants: Electric Arc Furnaces Constructed After October 21, 1974 and On or Before August 17, 1983

X

X

AAa

Steel Plants: Electric Arc Furnaces and Argon-Oxygen Decarburization Vessels Constructed After August 7, 1983

X

X

BB

Kraft Pulp Mills

X

CC

Glass Manufacturing Plants

X

X

DD

Grain Elevators

X

X

X

EE

Surface Coating of Metal Furniture

X

X

X

FF

(Reserved)

GG

Stationary Gas Turbines

X

X

X

HH

Lime Manufacturing Plants

X

X

X

KK

Lead-Acid Battery Manufacturing Plants

X

X

X

LL

Metallic Mineral Processing Plants

X

X

X

MM

Automobile and Light Duty Trucks Surface Coating Operations

X

X

X

NN

Phosphate Rock Plants

X

X

X

PP

Ammonium Sulfate Manufacture

X

X

QQ

Graphic Arts Industry: Publication Rotogravure Printing

X

X

X

RR

Pressure Sensitive Tape and Label Surface Coating Operations

X

X

SS

Industrial Surface Coating: Large Appliances

X

X

X

TT

Metal Coil Surface Coating

X

X

X

UU

Asphalt Processing and Asphalt Roofing Manufacture

X

X

X

VV

Equipment Leaks of VOC in the Synthetic Organic Industry Chemicals Manufacturing

X

X

X

VVa

Equipment Leaks of VOC in the Synthetic Organic Industry for Which Construction, Reconstruction, or Chemicals Manufacturing Modification Commenced After November 7, 2006

X

X

WW

Beverage Can Surface Coating Industry

X

X

XX

Bulk Gasoline Terminals

X

X

AAA

New Residential Wood Heaters

X

BBB

Rubber Tire Manufacturing Industry

X

X

CCC

(Reserved)

DDD

Volatile Organic Compounds (VOC) Emissions from the Polymer Manufacturing Industry

X

X

EEE

(Reserved)

FFF

Flexible Vinyl and Urethane Coating and Printing

X

X

GGG

Equipment Leaks of VOC in Petroleum Refineries

X

X

GGGa

Equipment Leaks of VOC in Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After November 7, 2006

X

X

HHH

Synthetic Fiber Production Facilities

X

X

III

Volatile Organic Compound (VOC) Emissions From the Synthetic Organic Chemical Manufacturing Industry (SOCMI) Air Oxidation Unit Processes

X

X

JJJ

Petroleum Dry Cleaners

X

X

X

KKK

Equipment Leaks of VOC From Onshore Natural Gas Processing Plants

X

X

LLL

Onshore Natural Gas Processing: SO 2 Emissions

X

X

MMM

(Reserved)

NNN

Volatile Organic Compound (VOC) Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Distillation Operations

X

X

OOO

Nonmetallic Mineral Processing Plants

X

X

PPP

Wool Fiberglass Insulation Manufacturing Plants

X

X

QQQ

VOC Emissions From Petroleum Refinery Wastewater Systems

X

X

RRR

Volatile Organic Compound Emissions from Synthetic Organic Chemical Manufacturing Industry (SOCMI) Reactor Processes

X

X

SSS

Magnetic Tape Coating Facilities

X

X

TTT

Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines

X

X

X

UUU

Calciners and Dryers in Mineral Industries

X

X

X

VVV

Polymeric Coating of Supporting Substrates Facilities

X

X

X

WWW

Municipal Solid Waste Landfills

X

X

X

XXX

Municipal Solid Waste Landfills that Commenced Construction, Reconstruction, or Modification after July 17, 2014

X

AAAA

Small Municipal Waste Combustion Units for Which Construction is Commenced After August 30, 1999 or for Which Modification or Reconstruction is Commended After June 6, 2001

X

X

X

CCCC

Commercial and Industrial Solid Waste Incineration Units for Which Construction Is Commenced After November 30, 1999 or for Which Modification or Reconstruction Is Commenced on or After June 1, 2001

X

X

X

EEEE

Other Solid Waste Incineration Units for Which Construction is Commenced After December 9, 2004, or for Which Modification or Reconstruction is Commenced on or After June 16, 2006

X

X

X

GGGG

(Reserved)

HHHH

(Reserved)

IIII

Stationary Compression Ignition Internal Combustion Engines

X

X

X

JJJJ

Stationary Spark Ignition Internal Combustion Engines

X

X

X

KKKK

Stationary Combustion Turbines

X

X

X

LLLL

New Sewage Sludge Incineration Units

X

OOOO

Crude Oil and Natural Gas Production, Transmission, and Distribution

X

(5) Guam. The following table identifies delegations as of June 15, 2001:

Delegation Status for New Source Performance Standards for Guam

Subpart

Guam

A

General Provisions

X

D

Fossil-Fuel Fired Steam Generators Constructed After August 17, 1971

X

Da

Electric Utility Steam Generating Units Constructed After September 18, 1978

Db

Industrial-Commercial-Institutional Steam Generating Units

Dc

Small Industrial Steam Generating Units

E

Incinerators

Ea

Municipal Waste Combustors Constructed After December 20, 1989 and On or Before September 20, 1994

Eb

Municipal Waste Combustors Constructed After September 20, 1994

Ec

Hospital/Medical/Infectious Waste Incinerators for Which Construction is Commenced After June 20, 1996

F

Portland Cement Plants

X

G

Nitric Acid Plants

H

Sulfuric Acid Plants

I

Hot Mix Asphalt Facilities

X

J

Petroleum Refineries

X

K

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After June 11, 1973, and Prior to May 19, 1978

X

(e) The following lists the specific part 60 standards that have been delegated unchanged to the air pollution control agencies in Region 6.

(1) New Mexico. The New Mexico Environment Department has been delegated all part 60 standards promulgated by the EPA, except subpart AAA—Standards of Performance for New Residential Wood Heaters; and subpart QQQQ—Standards of Performance for New Residential Hydronic Heaters and Forced-Air Furnaces, as amended in the Federal Register through January 15, 2017.

(2) Louisiana. The Louisiana Department of Environmental Quality has been delegated the following part 60 standards promulgated by EPA, as amended in the Federal Register through July 1, 2021. The (X) symbol is used to indicate each subpart that has been delegated.

Delegation Status for Part 60 Standards—State of Louisiana

[Excluding Indian Country]

Subpart

Source category

LDEQ

A

General Provisions

X

Cb

Emissions Guidelines and Compliance Times for Large Municipal Waste Combustors That are Constructed on or Before September 20, 1994

X

Cc

Emission Guidelines and Compliance Times for Municipal Solid Waste Landfills

X

Cd

Emissions Guidelines and Compliance Times for Sulfuric Acid Production Units

X

Ce

Emission Guidelines and Compliance Times for Hospital/Medical/Infectious Waste Incinerators

X

Cf

Emission Guidelines and Compliance Times for Municipal Solid Waste Landfills

X

D

Fossil Fueled Steam Generators

X

Da

Electric Utility Steam Generating Units

X

Db

Industrial-Commercial-Institutional Steam Generating Units

X

Dc

Small Industrial-Commercial-Institutional Steam Generating Units

X

E

Incinerators

X

Ea

Municipal Waste Combustors for Which Construction is Commenced After December 20, 1989, and On or Before September 20, 1994

X

Eb

Large Municipal Waste Combustors for Which Construction is Commenced After September 20, 1994 or for Which Modification or Reconstruction is Commenced After June 19, 1996

X

Ec

Hospital/Medical/Infectious Waste Incinerators

X

F

Portland Cement Plants

X

G

Nitric Acid Plants

X

Ga

Nitric Acid Plants for Which Construction, Reconstruction, or Modification Commenced After October 14, 2011

X

H

Sulfuric Acid Plants

X

I

Hot Mix Asphalt Facilities

X

J

Petroleum Refineries

X

Ja

Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After May 14, 2007

X

K

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After June 11, 1973, and Prior to May 19, 1978

X

Ka

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After May 18, 1978, and Prior to July 23, 1984

X

Kb

VOC Liquid Storage Vessels (Including Petroleum Liquid Storage Vessels) for Which Construction, Reconstruction, or Modification Commenced After July 23, 1984, and On or Before October 4, 2023

X

Kc

VOC Liquid Storage Vessels (Including Petroleum Liquid Storage Vessels) for Which Construction, October 4, 2023

No

L

Secondary Lead Smelters for Which Construction, Reconstruction, or Modification Commenced After June 11, 1973, and On or Before December 1, 2022

X

La

Secondary Lead Smelters for Which Construction, Reconstruction, or Modification Commenced After December 1, 2022

No

M

Secondary Brass and Bronze Production Plants

X

N

Primary Emissions from Basic Oxygen Process Furnaces for Which Construction Commenced After June 11, 1973

X

Na

Secondary Emissions from Basic Oxygen Process Steelmaking Facilities for Which Construction is Commenced After January 20, 1983

X

O

Sewage Treatment Plants

X

P

Primary Copper Smelters

X

Q

Primary Zinc Smelters

X

R

Primary Lead Smelters

X

S

Primary Aluminum Reduction Plants

X

T

Phosphate Fertilizer Industry: Wet Process Phosphoric Plants

X

U

Phosphate Fertilizer Industry: Superphosphoric Acid Plants

X

V

Phosphate Fertilizer Industry: Diammonium Phosphate Plants

X

W

Phosphate Fertilizer Industry: Triple Superphosphate Plants

X

X

Phosphate Fertilizer Industry: Granular Triple Superphosphate Storage Facilities

X

Y

Coal Preparation and Processing Plants

X

Z

Ferroalloy Production Facilities

X

AA

Steel Plants: Electric Arc Furnaces Constructed After October 21, 1974, and On or Before August 17, 1983

X

AAa

Steel Plants: Electric Arc Furnaces & Argon-Oxygen Decarburization Vessels Constructed After August 17, 1983, and On or Before May 16, 2022

X

AAb

Steel Plants: Electric Arc Furnaces & Argon-Oxygen Decarburization Vessels Constructed After May 16, 2022

No

BB

Kraft Pulp Mills

X

BBa

Kraft Pulp Mill Affected Sources for Which Construction, Reconstruction, or Modification Commenced After May 23, 2013

X

CC

Glass Manufacturing Plants

X

DD

Grain Elevators

X

EE

Surface Coating of Metal Furniture

X

GG

Stationary Gas Turbines

X

HH

Lime Manufacturing Plants

X

KK

Lead-Acid Battery Manufacturing Plants for Which Construction, Reconstruction, or Modification Commenced After January 14, 1980, and On or Before February 23, 2022

X

KKa

Lead-Acid Battery Manufacturing Plants for Which Construction, Reconstruction, or Modification Commenced After February 23, 2022

No

LL

Metallic Mineral Processing Plants

X

MM

Automobile & Light Duty Truck Surface Coating Operations for which Construction, Modification or Reconstruction Commenced After October 5, 1979, and On or Before May 18, 2022

X

MMa

Automobile & Light Duty Truck Surface Coating Operations for which Construction, Modification or Reconstruction Commenced After May 18, 2022

No

NN

Phosphate Manufacturing Plants

X

PP

Ammonium Sulfate Manufacture

X

QQ

Graphic Arts Industry: Publication Rotogravure Printing

X

RR

Pressure Sensitive Tape and Label Surface Coating Operations

X

SS

Industrial Surface Coating: Large Appliances

X

TT

Metal Coil Surface Coating

X

UU

Asphalt Processing and Asphalt Roofing Manufacture

X

VV

Equipment Leaks of VOC in the SOCMI Industry for Which Construction, Reconstruction, or Modification Commenced After January 5, 1981, and on or Before November 7, 2006

X

VVa

Equipment Leaks of VOC in the SOCMI Industry for Which Construction, Reconstruction, or Modification Commenced After November 7, 2006, and on or Before April 25, 2023

X

VVb

Equipment Leaks of VOC in the SOCMI Industry for Which Construction, Reconstruction, or Modification Commenced After April 25, 2023

No

WW

Beverage Can Surface Coating Industry

X

XX

Bulk Gasoline Terminals That Commenced Construction, Modification, or Reconstruction After December 17, 1980, and On or Before June 10, 2022

X

XXa

Bulk Gasoline Terminals That Commenced Construction, Modification, or Reconstruction After June 10, 2022

No

AAA

New Residential Wood Heaters

No

BBB

Rubber Tire Manufacturing Industry

X

CCC

[Reserved]

DDD

Volatile Organic Compound (VOC) Emissions from the Polymer Manufacturing Industry

X

EEE

[Reserved]

FFF

Flexible Vinyl and Urethane Coating and Printing

X

GGG

Equipment Leaks of VOC in Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After January 4, 1983, and On or Before November 7, 2006

X

GGGa

Equipment Leaks of VOC in Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After November 7, 2006

X

HHH

Synthetic Fiber Production

X

III

VOC Emissions from the SOCMI Air Oxidation Unit Processes

X

IIIa

VOC Emissions from the SOCMI Air Oxidation Unit Processes for Which Construction, Reconstruction, or Modification Commenced After April 25, 2023

No

JJJ

Petroleum Dry Cleaners

X

KKK

VOC Equipment Leaks From Onshore Natural Gas Processing Plants

X

LLL

Onshore Natural Gas Processing: SO 2 Emissions

X

MMM

[Reserved]

NNN

VOC Emissions from SOCMI Distillation Operations

X

NNNa

VOC Emissions from SOCMI Distillation Operations for Which Construction, Reconstruction, or Modification Commenced After April 25, 2023

No

OOO

Nonmetallic Mineral Processing Plants

X

PPP

Wool Fiberglass Insulation Manufacturing Plants

X

QQQ

VOC Emissions From Petroleum Refinery Wastewater Systems

X

RRR

VOC Emissions from SOCMI Reactor Processes

X

RRRa

VOC Emissions from SOCMI Reactor Processes for Which Construction, Reconstruction, or Modification Commenced After April 25, 2023

No

SSS

Magnetic Tape Coating Operations

X

TTT

Industrial Surface Coating: Plastic Parts for Business Machines

X

TTTa

Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines for Which Construction, Reconstruction, or Modification Commenced After June 21, 2022

No

UUU

Calciners and Dryers in Mineral Industries

X

VVV

Polymeric Coating of Supporting Substrates Facilities

X

WWW

Municipal Solid Waste Landfills

X

XXX

Municipal Solid Waste Landfills That Commenced Construction, Reconstruction, or Modification After July 17, 2014

X

YYY-ZZZ

[Reserved]

AAAA

Small Municipal Waste Combustion Units (Construction is Commenced After 8/30/99 or Modification/Reconstruction is Commenced After 6/06/2001)

X

BBBB

Emission Guidelines and Compliance Times for Small Municipal Waste Combustion Units Constructed on or Before August 30, 1999

X

CCCC

Commercial & Industrial Solid Waste Incineration Units (Construction is Commenced After 11/30/1999 or Modification/Reconstruction is Commenced on or After 6/01/2001)

X

DDDD

Emission Guidelines & Compliance Times for Commercial & Industrial Solid Waste Incineration Units (Commenced Construction On or Before 11/30/1999)

X

EEEE

Other Solid Waste Incineration Units (Constructed after 12/09/2004 or Modification/Reconstruction is commenced on or after 06/16/2004)

X

FFFF

Emission Guidelines and Compliance Times for Other Solid Waste Incineration Units that Commenced Construction On or Before December 9, 2004

X

GGG-HHH

[Reserved]

IIII

Stationary Compression Ignition Internal Combustion Engines

X

JJJJ

Stationary Spark Ignition Internal Combustion Engines

X

KKKK

Stationary Combustion Turbines (Construction Commenced After 02/18/2005)

X

LLLL

New Sewage Sludge Incineration Units

X

MMMM

Emission Guidelines and Compliance Times for Existing Sewage Sludge Incineration Units

X

NNNN

[Reserved]

OOOO

Crude Oil and Natural Gas Production, Transmission and Distribution

X

OOOOa

Crude Oil and Natural Gas Facilities for Which Construction, Modification or Reconstruction Commenced After September 18, 2015 and On or Before December 6, 2022

X

OOOOb

Crude Oil and Natural Gas Facilities for Which Construction, Modification or Reconstruction Commenced After December 6, 2022

No

OOOOc

Emissions Guidelines for Greenhouse Gas Emissions from Existing Crude Oil and Natural Gas Facilities

No

PPPP

[Reserved]

QQQQ

New Residential Hydronic Heaters and Forced-Air Furnaces

X

TTTT

Greenhouse Gas Emissions for Electric Generating Units

X

TTTTa

Greenhouse Gas Emissions for Modified Coal-Fired Steam Electric Generating Units and New Construction and Reconstruction Stationary Combustion Turbine Electric Generating Units

No

UUUUa

[Reserved]

UUUUb

Greenhouse Gas Emissions for Electric Utility Generating Units

No

(3) Albuquerque-Bernalillo County Air Quality Control Board. The Albuquerque-Bernalillo County Air Quality Control Board has been delegated all part 60 standards promulgated by the EPA, except subpart AAA of this part and subpart QQQQ of this part as amended through January 23, 2017.

(4) The Oklahoma Department of Environmental Quality (ODEQ) has been delegated the following 40 CFR part 60 standards promulgated by EPA, as amended in the Federal Register through June 30, 2023. The (X) symbol is used to indicate each subpart that has been delegated.

Table 3 to Paragraph ( b )—Delegation Status for Part 60 Standards—State of Oklahoma

Subpart

Source category

ODEQ

A

General Provisions (except §§ 60.4, 60.9, 60.10 and 60.16)

X

Cb

Emissions Guidelines and Compliance Times for Large Municipal Waste Combustors That are Constructed On or Before September 20, 1994

No

Cc

Emission Guidelines and Compliance Times for Municipal Solid Waste Landfills

No

Cd

Emissions Guidelines and Compliance Times for Sulfuric Acid Production Units

No

Ce

Emission Guidelines and Compliance Times for Hospital/Medical/Infectious Waste Incinerators

No

Cf

Emission Guidelines and Compliance Times for Municipal Solid Waste Landfills

No

D

Fossil Fueled Steam Generators

X

Da

Electric Utility Steam Generating Units

X

Db

Industrial-Commercial-Institutional Steam Generating Units

X

Dc

Small Industrial-Commercial-Institutional Steam Generating Units

X

E

Incinerators

X

Ea

Municipal Waste Combustors for Which Construction is Commenced After December 20, 1989, and On or Before September 20, 1994

X

Eb

Large Municipal Waste Combustors for Which Construction is Commenced After September 20, 1994 or for Which Modification or Reconstruction is Commenced After June 19, 1996

X

Ec

Hospital/Medical/Infectious Waste Incinerators

X

F

Portland Cement Plants

X

G

Nitric Acid Plants

X

Ga

Nitric Acid Plants for Which Construction, Reconstruction, or Modification Commenced After October 14, 2011

X

H

Sulfuric Acid Plants

X

I

Hot Mix Asphalt Facilities

X

J

Petroleum Refineries

X

Ja

Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After May 14, 2007

X

K

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After June 11, 1973, and Prior to May 19, 1978

X

Ka

Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After May 18, 1978, and Prior to July 23, 1984

X

Kb

VOC Liquid Storage Vessels (Including Petroleum Liquid Storage Vessels) for Which Construction, Reconstruction, or Modification Commenced After July 23, 1984, and On or Before October 4, 2023

X

Kc

VOC Liquid Storage Vessels (Including Petroleum Liquid Storage Vessels) for Which Construction, October 4, 2023

No

L

Secondary Lead Smelters for Which Construction, Reconstruction, or Modification Commenced After June 11, 1973, and On or Before December 1, 2022

X

La

Secondary Lead Smelters for Which Construction, Reconstruction, or Modification Commenced After December 1, 2022

No

M

Secondary Brass and Bronze Production Plants

X

N

Primary Emissions from Basic Oxygen Process Furnaces for Which Construction Commenced After June 11, 1973

X

Na

Secondary Emissions from Basic Oxygen Process Steelmaking Facilities for Which Construction is Commenced After January 20, 1983

X

O

Sewage Treatment Plants

X

P

Primary Copper Smelters

X

Q

Primary Zinc Smelters

X

R

Primary Lead Smelters

X

S

Primary Aluminum Reduction Plants

X

T

Phosphate Fertilizer Industry: Wet Process Phosphoric Plants

X

U

Phosphate Fertilizer Industry: Superphosphoric Acid Plants

X

V

Phosphate Fertilizer Industry: Diammonium Phosphate Plants

X

W

Phosphate Fertilizer Industry: Triple Superphosphate Plants

X

X

Phosphate Fertilizer Industry: Granular Triple Superphosphate Storage Facilities

X

Y

Coal Preparation and Processing Plants

X

Z

Ferroalloy Production Facilities

X

AA

Steel Plants: Electric Arc Furnaces Constructed After October 21, 1974, and On or Before August 17, 1983

X

AAa

Steel Plants: Electric Arc Furnaces & Argon-Oxygen Decarburization Vessels Constructed After August 17, 1983, and On or Before May 16, 2022

X

AAb

Steel Plants: Electric Arc Furnaces & Argon-Oxygen Decarburization Vessels Constructed After May 16, 2022

No

BB

Kraft Pulp Mills

X

BBa

Kraft Pulp Mill Affected Sources for Which Construction, Reconstruction, or Modification Commenced After May 23, 2013

X

CC

Glass Manufacturing Plants

X

DD

Grain Elevators

X

EE

Surface Coating of Metal Furniture

X

GG

Stationary Gas Turbines

X

HH

Lime Manufacturing Plants

X

KK

Lead-Acid Battery Manufacturing Plants for Which Construction, Reconstruction, or Modification Commenced After January 14, 1980, and On or Before February 23, 2022

X

KKa

Lead-Acid Battery Manufacturing Plants for Which Construction, Reconstruction, or Modification Commenced After February 23, 2022

X

LL

Metallic Mineral Processing Plants

X

MM

Automobile & Light Duty Truck Surface Coating Operations for which Construction, Modification or Reconstruction Commenced After October 5, 1979, and On or Before May 18, 2022

X

MMa

Automobile & Light Duty Truck Surface Coating Operations for which Construction, Modification or Reconstruction Commenced After May 18, 2022

X

NN

Phosphate Manufacturing Plants

X

PP

Ammonium Sulfate Manufacture

X

QQ

Graphic Arts Industry: Publication Rotogravure Printing

X

RR

Pressure Sensitive Tape and Label Surface Coating Operations

X

SS

Industrial Surface Coating: Large Appliances

X

TT

Metal Coil Surface Coating

X

UU

Asphalt Processing and Asphalt Roofing Manufacture

X

VV

Equipment Leaks of VOC in the SOCMI Industry for Which Construction, Reconstruction, or Modification Commenced After January 5, 1981, and On or Before November 7, 2006

X

VVa

Equipment Leaks of VOC in the SOCMI Industry for Which Construction, Reconstruction, or Modification Commenced After November 7, 2006, and On or Before April 25, 2023

X

VVb

Equipment Leaks of VOC in the SOCMI Industry for Which Construction, Reconstruction, or Modification Commenced After April 25, 2023

No

WW

Beverage Can Surface Coating Industry

X

XX

Bulk Gasoline Terminals That Commenced Construction, Modification, or Reconstruction After December 17, 1980, and On or Before June 10, 2022

X

XXa

Bulk Gasoline Terminals That Commenced Construction, Modification, or Reconstruction After June 10, 2022

No

AAA

New Residential Wood Heaters

No

BBB

Rubber Tire Manufacturing Industry

X

CCC

[Reserved]

DDD

Volatile Organic Compound (VOC) Emissions from the Polymer Manufacturing Industry

X

EEE

[Reserved]

FFF

Flexible Vinyl and Urethane Coating and Printing

X

GGG

Equipment Leaks of VOC in Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After January 4, 1983, and n or Before November 7, 2006

X

GGGa

Equipment Leaks of VOC in Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After November 7, 2006

X

HHH

Synthetic Fiber Production

X

III

VOC Emissions from the SOCMI Air Oxidation Unit Processes

X

IIIa

VOC Emissions from the SOCMI Air Oxidation Unit Processes for Which Construction, Reconstruction, or Modification Commenced After April 25, 2023

No

JJJ

Petroleum Dry Cleaners

X

KKK

VOC Equipment Leaks From Onshore Natural Gas Processing Plants

X

LLL

Onshore Natural Gas Processing: SO 2 Emissions

X

MMM

[Reserved]

NNN

VOC Emissions from SOCMI Distillation Operations

X

NNNa

VOC Emissions from SOCMI Distillation Operations for Which Construction, Reconstruction, or Modification Commenced After April 25, 2023

No

OOO

Nonmetallic Mineral Processing Plants

X

PPP

Wool Fiberglass Insulation Manufacturing Plants

X

QQQ

VOC Emissions From Petroleum Refinery Wastewater Systems

X

RRR

VOC Emissions from SOCMI Reactor Processes

X

RRRa

VOC Emissions from SOCMI Reactor Processes for Which Construction, Reconstruction, or Modification Commenced After April 25, 2023

No

SSS

Magnetic Tape Coating Operations

X

TTT

Industrial Surface Coating: Plastic Parts for Business Machines

X

TTTa

Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines for Which Construction, Reconstruction, or Modification Commenced After June 21, 2022

X

UUU

Calciners and Dryers in Mineral Industries

X

VVV

Polymeric Coating of Supporting Substrates Facilities

X

WWW

Municipal Solid Waste Landfills

X

XXX

Municipal Solid Waste Landfills that Commenced Construction, Reconstruction, or Modification after July 17, 2014

X

YYY-ZZZ

[Reserved]

AAAA

Small Municipal Waste Combustion Units (Construction is Commenced After 8/30/99 or Modification/Reconstruction is Commenced After 6/06/2001)

X

BBBB

Emission Guidelines and Compliance Times for Small Municipal Waste Combustion Units Constructed On or Before August 30, 1999

No

CCCC

Commercial & Industrial Solid Waste Incineration Units (Construction is Commenced After 11/30/1999 or Modification/Reconstruction is Commenced On or After 6/01/2001)

X

DDDD

Emission Guidelines & Compliance Times for Commercial & Industrial Solid Waste Incineration Units (Commenced Construction On or Before 11/30/1999)

No

EEEE

Other Solid Waste Incineration Units (Constructed after 12/09/2004 or Modification/Reconstruction is commenced On or After 06/16/2004)

X

FFFF

Emission Guidelines and Compliance Times for Other Solid Waste Incineration Units that Commenced Construction On or Before December 9, 2004

No

GGG-HHH

[Reserved]

IIII

Stationary Compression Ignition Internal Combustion Engines

X

JJJJ

Stationary Spark Ignition Internal Combustion Engines

X

KKKK

Stationary Combustion Turbines (Construction Commenced After 02/18/2005)

X

LLLL

New Sewage Sludge Incineration Units

X

MMMM

Emission Guidelines and Compliance Times for Existing Sewage Sludge Incineration Units

No

NNNN

[Reserved]

OOOO

Crude Oil and Natural Gas Production, Transmission and Distribution

X

OOOOa

Crude Oil and Natural Gas Facilities for Which Construction, Modification or Reconstruction Commenced After September 18, 2015 and On or Before December 6, 2022

X

OOOOb

Crude Oil and Natural Gas Facilities for Which Construction, Modification or Reconstruction Commenced After December 6, 2022

No

OOOOc

Emissions Guidelines for Greenhouse Gas Emissions from Existing Crude Oil and Natural Gas Facilities

No

PPPP

[Reserved]

QQQQ

New Residential Hydronic Heaters and Forced-Air Furnaces

No

TTTT

Greenhouse Gas Emissions for Electric Generating Units

X

TTTTa

Greenhouse Gas Emissions for Modified Coal-Fired Steam Electric Generating Units and New Construction and Reconstruction Stationary Combustion Turbine Electric Generating Units

No

UUUUa

[Reserved]

UUUUb

Greenhouse Gas Emissions for Electric Utility Generating Units

No

Appendix A

Test Methods

X

Appendix B

Performance Specifications

X

§ 60.5Determination of construction or modification.

(a) When requested to do so by an owner or operator, the Administrator will make a determination of whether action taken or intended to be taken by such owner or operator constitutes construction (including reconstruction) or modification or the commencement thereof within the meaning of this part.

(b) The Administrator will respond to any request for a determination under paragraph (a) of this section within 30 days of receipt of such request.

§ 60.6Review of plans.

(a) When requested to do so by an owner or operator, the Administrator will review plans for construction or modification for the purpose of providing technical advice to the owner or operator.

(b)(1) A separate request shall be submitted for each construction or modification project.

(2) Each request shall identify the location of such project, and be accompanied by technical information describing the proposed nature, size, design, and method of operation of each affected facility involved in such project, including information on any equipment to be used for measurement or control of emissions.

(c) Neither a request for plans review nor advice furnished by the Administrator in response to such request shall (1) relieve an owner or operator of legal responsibility for compliance with any provision of this part or of any applicable State or local requirement, or (2) prevent the Administrator from implementing or enforcing any provision of this part or taking any other action authorized by the Act.

§ 60.7Notification and record keeping.

(a) Any owner or operator subject to the provisions of this part shall furnish the Administrator written notification or, if acceptable to both the Administrator and the owner or operator of a source, electronic notification, as follows:

(1) A notification of the date construction (or reconstruction as defined under § 60.15) of an affected facility is commenced postmarked no later than 30 days after such date. This requirement shall not apply in the case of mass-produced facilities which are purchased in completed form.

(2) [Reserved]

(3) A notification of the actual date of initial startup of an affected facility postmarked within 15 days after such date.

(4) A notification of any physical or operational change to an existing facility which may increase the emission rate of any air pollutant to which a standard applies, unless that change is specifically exempted under an applicable subpart or in § 60.14(e). This notice shall be postmarked 60 days or as soon as practicable before the change is commenced and shall include information describing the precise nature of the change, present and proposed emission control systems, productive capacity of the facility before and after the change, and the expected completion date of the change. The Administrator may request additional relevant information subsequent to this notice.

(5) A notification of the date upon which demonstration of the continuous monitoring system performance commences in accordance with § 60.13(c). Notification shall be postmarked not less than 30 days prior to such date.

(6) A notification of the anticipated date for conducting the opacity observations required by § 60.11(e)(1) of this part. The notification shall also include, if appropriate, a request for the Administrator to provide a visible emissions reader during a performance test. The notification shall be postmarked not less than 30 days prior to such date.

(7) A notification that continuous opacity monitoring system data results will be used to determine compliance with the applicable opacity standard during a performance test required by § 60.8 in lieu of Method 9 observation data as allowed by § 60.11(e)(5) of this part. This notification shall be postmarked not less than 30 days prior to the date of the performance test.

(b) Any owner or operator subject to the provisions of this part shall maintain records of the occurrence and duration of any startup, shutdown, or malfunction in the operation of an affected facility; any malfunction of the air pollution control equipment; or any periods during which a continuous monitoring system or monitoring device is inoperative.

(c) Each owner or operator required to install a continuous monitoring device shall submit excess emissions and monitoring systems performance report (excess emissions are defined in applicable subparts) and-or summary report form (see paragraph (d) of this section) to the Administrator semiannually, except when: more frequent reporting is specifically required by an applicable subpart; or the Administrator, on a case-by-case basis, determines that more frequent reporting is necessary to accurately assess the compliance status of the source. All reports shall be postmarked by the 30th day following the end of each six-month period. Written reports of excess emissions shall include the following information:

(1) The magnitude of excess emissions computed in accordance with § 60.13(h), any conversion factor(s) used, and the date and time of commencement and completion of each time period of excess emissions. The process operating time during the reporting period.

(2) Specific identification of each period of excess emissions that occurs during startups, shutdowns, and malfunctions of the affected facility. The nature and cause of any malfunction (if known), the corrective action taken or preventative measures adopted.

(3) The date and time identifying each period during which the continuous monitoring system was inoperative except for zero and span checks and the nature of the system repairs or adjustments.

(4) When no excess emissions have occurred or the continuous monitoring system(s) have not been inoperative, repaired, or adjusted, such information shall be stated in the report.

(d) The summary report form shall contain the information and be in the format shown in figure 1 unless otherwise specified by the Administrator. One summary report form shall be submitted for each pollutant monitored at each affected facility.

(1) If the total duration of excess emissions for the reporting period is less than 1 percent of the total operating time for the reporting period and CMS downtime for the reporting period is less than 5 percent of the total operating time for the reporting period, only the summary report form shall be submitted and the excess emission report described in § 60.7(c) need not be submitted unless requested by the Administrator.

(2) If the total duration of excess emissions for the reporting period is 1 percent or greater of the total operating time for the reporting period or the total CMS downtime for the reporting period is 5 percent or greater of the total operating time for the reporting period, the summary report form and the excess emission report described in § 60.7(c) shall both be submitted.

Figure 1—Summary Report—Gaseous and Opacity Excess Emission and Monitoring System Performance

Pollutant (Circle One—SO 2 /NO X /TRS/H 2 S/CO/Opacity)

Reporting period dates: From ____________________ to ____________________

Company:

Emission Limitation

Address:

Monitor Manufacturer and Model No.

Date of Latest CMS Certification or Audit

Process Unit(s) Description:

Total source operating time in reporting period

1

Emission data summary 1

CMS performance summary 1

1. Duration of excess emissions in reporting period due to:

1. CMS downtime in reporting period due to:

a. Startup/shutdown

a. Monitor equipment malfunctions

b. Control equipment problems

b. Non-Monitor equipment malfunctions

c. Process problems

c. Quality assurance calibration

d. Other known causes

d. Other known causes

e. Unknown causes

e. Unknown causes

2. Total duration of excess emission

2. Total CMS Downtime

3. Total duration of excess emissions × (100) [Total source operating time]

% 2

3. [Total CMS Downtime] × (100) [Total source operating time]

% 2

1 For opacity, record all times in minutes. For gases, record all times in hours.

2 For the reporting period: If the total duration of excess emissions is 1 percent or greater of the total operating time or the total CMS downtime is 5 percent or greater of the total operating time, both the summary report form and the excess emission report described in § 60.7(c) shall be submitted.

On a separate page, describe any changes since last quarter in CMS, process or controls. I certify that the information contained in this report is true, accurate, and complete.

Name

Signature

Title

Date

(e)(1) Notwithstanding the frequency of reporting requirements specified in paragraph (c) of this section, an owner or operator who is required by an applicable subpart to submit excess emissions and monitoring systems performance reports (and summary reports) on a quarterly (or more frequent) basis may reduce the frequency of reporting for that standard to semiannual if the following conditions are met:

(i) For 1 full year (e.g., 4 quarterly or 12 monthly reporting periods) the affected facility's excess emissions and monitoring systems reports submitted to comply with a standard under this part continually demonstrate that the facility is in compliance with the applicable standard;

(ii) The owner or operator continues to comply with all recordkeeping and monitoring requirements specified in this subpart and the applicable standard; and

(iii) The Administrator does not object to a reduced frequency of reporting for the affected facility, as provided in paragraph (e)(2) of this section.

(2) The frequency of reporting of excess emissions and monitoring systems performance (and summary) reports may be reduced only after the owner or operator notifies the Administrator in writing of his or her intention to make such a change and the Administrator does not object to the intended change. In deciding whether to approve a reduced frequency of reporting, the Administrator may review information concerning the source's entire previous performance history during the required recordkeeping period prior to the intended change, including performance test results, monitoring data, and evaluations of an owner or operator's conformance with operation and maintenance requirements. Such information may be used by the Administrator to make a judgment about the source's potential for noncompliance in the future. If the Administrator disapproves the owner or operator's request to reduce the frequency of reporting, the Administrator will notify the owner or operator in writing within 45 days after receiving notice of the owner or operator's intention. The notification from the Administrator to the owner or operator will specify the grounds on which the disapproval is based. In the absence of a notice of disapproval within 45 days, approval is automatically granted.

(3) As soon as monitoring data indicate that the affected facility is not in compliance with any emission limitation or operating parameter specified in the applicable standard, the frequency of reporting shall revert to the frequency specified in the applicable standard, and the owner or operator shall submit an excess emissions and monitoring systems performance report (and summary report, if required) at the next appropriate reporting period following the noncomplying event. After demonstrating compliance with the applicable standard for another full year, the owner or operator may again request approval from the Administrator to reduce the frequency of reporting for that standard as provided for in paragraphs (e)(1) and (e)(2) of this section.

(f) Any owner or operator subject to the provisions of this part shall maintain a file of all measurements, including continuous monitoring system, monitoring device, and performance testing measurements; all continuous monitoring system performance evaluations; all continuous monitoring system or monitoring device calibration checks; adjustments and maintenance performed on these systems or devices; and all other information required by this part recorded in a permanent form suitable for inspection. The file shall be retained for at least two years following the date of such measurements, maintenance, reports, and records, except as follows:

(1) This paragraph applies to owners or operators required to install a continuous emissions monitoring system (CEMS) where the CEMS installed is automated, and where the calculated data averages do not exclude periods of CEMS breakdown or malfunction. An automated CEMS records and reduces the measured data to the form of the pollutant emission standard through the use of a computerized data acquisition system. In lieu of maintaining a file of all CEMS subhourly measurements as required under paragraph (f) of this section, the owner or operator shall retain the most recent consecutive three averaging periods of subhourly measurements and a file that contains a hard copy of the data acquisition system algorithm used to reduce the measured data into the reportable form of the standard.

(2) This paragraph applies to owners or operators required to install a CEMS where the measured data is manually reduced to obtain the reportable form of the standard, and where the calculated data averages do not exclude periods of CEMS breakdown or malfunction. In lieu of maintaining a file of all CEMS subhourly measurements as required under paragraph (f) of this section, the owner or operator shall retain all subhourly measurements for the most recent reporting period. The subhourly measurements shall be retained for 120 days from the date of the most recent summary or excess emission report submitted to the Administrator.

(3) The Administrator or delegated authority, upon notification to the source, may require the owner or operator to maintain all measurements as required by paragraph (f) of this section, if the Administrator or the delegated authority determines these records are required to more accurately assess the compliance status of the affected source.

(g) If notification substantially similar to that in paragraph (a) of this section is required by any other State or local agency, sending the Administrator a copy of that notification will satisfy the requirements of paragraph (a) of this section.

(h) Individual subparts of this part may include specific provisions which clarify or make inapplicable the provisions set forth in this section.

§ 60.8Performance tests.

(a) Except as specified in paragraphs (a)(1),(a)(2), (a)(3), and (a)(4) of this section, within 60 days after achieving the maximum production rate at which the affected facility will be operated, but not later than 180 days after initial startup of such facility, or at such other times specified by this part, and at such other times as may be required by the Administrator under section 114 of the Act, the owner or operator of such facility shall conduct performance test(s) and furnish the Administrator a written report of the results of such performance test(s).

(1) If a force majeure is about to occur, occurs, or has occurred for which the affected owner or operator intends to assert a claim of force majeure, the owner or operator shall notify the Administrator, in writing as soon as practicable following the date the owner or operator first knew, or through due diligence should have known that the event may cause or caused a delay in testing beyond the regulatory deadline, but the notification must occur before the performance test deadline unless the initial force majeure or a subsequent force majeure event delays the notice, and in such cases, the notification shall occur as soon as practicable.

(2) The owner or operator shall provide to the Administrator a written description of the force majeure event and a rationale for attributing the delay in testing beyond the regulatory deadline to the force majeure; describe the measures taken or to be taken to minimize the delay; and identify a date by which the owner or operator proposes to conduct the performance test. The performance test shall be conducted as soon as practicable after the force majeure occurs.

(3) The decision as to whether or not to grant an extension to the performance test deadline is solely within the discretion of the Administrator. The Administrator will notify the owner or operator in writing of approval or disapproval of the request for an extension as soon as practicable.

(4) Until an extension of the performance test deadline has been approved by the Administrator under paragraphs (a)(1), (2), and (3) of this section, the owner or operator of the affected facility remains strictly subject to the requirements of this part.

(b) Performance tests shall be conducted and data reduced in accordance with the test methods and procedures contained in each applicable subpart unless the Administrator (1) specifies or approves, in specific cases, the use of a reference method with minor changes in methodology, (2) approves the use of an equivalent method, (3) approves the use of an alternative method the results of which he has determined to be adequate for indicating whether a specific source is in compliance, (4) waives the requirement for performance tests because the owner or operator of a source has demonstrated by other means to the Administrator's satisfaction that the affected facility is in compliance with the standard, or (5) approves shorter sampling times and smaller sample volumes when necessitated by process variables or other factors. Nothing in this paragraph shall be construed to abrogate the Administrator's authority to require testing under section 114 of the Act.

(c) Performance tests shall be conducted under such conditions as the Administrator shall specify to the plant operator based on representative performance of the affected facility. The owner or operator shall make available to the Administrator such records as may be necessary to determine the conditions of the performance tests. Operations during periods of startup, shutdown, and malfunction shall not constitute representative conditions for the purpose of a performance test nor shall emissions in excess of the level of the applicable emission limit during periods of startup, shutdown, and malfunction be considered a violation of the applicable emission limit unless otherwise specified in the applicable standard.

(d) The owner or operator of an affected facility shall provide the Administrator at least 30 days prior notice of any performance test, except as specified under other subparts, to afford the Administrator the opportunity to have an observer present. If after 30 days notice for an initially scheduled performance test, there is a delay (due to operational problems, etc.) in conducting the scheduled performance test, the owner or operator of an affected facility shall notify the Administrator (or delegated State or local agency) as soon as possible of any delay in the original test date, either by providing at least 7 days prior notice of the rescheduled date of the performance test, or by arranging a rescheduled date with the Administrator (or delegated State or local agency) by mutual agreement.

(e) The owner or operator of an affected facility shall provide, or cause to be provided, performance testing facilities as follows:

(1) Sampling ports adequate for test methods applicable to such facility. This includes (i) constructing the air pollution control system such that volumetric flow rates and pollutant emission rates can be accurately determined by applicable test methods and procedures and (ii) providing a stack or duct free of cyclonic flow during performance tests, as demonstrated by applicable test methods and procedures.

(2) Safe sampling platform(s).

(3) Safe access to sampling platform(s).

(4) Utilities for sampling and testing equipment.

(f) Unless otherwise specified in the applicable subpart, each performance test shall consist of three separate runs using the applicable test method.

(1) Each run shall be conducted for the time and under the conditions specified in the applicable standard. For the purpose of determining compliance with an applicable standard, the arithmetic means of results of the three runs shall apply. In the event that a sample is accidentally lost or conditions occur in which one of the three runs must be discontinued because of forced shutdown, failure of an irreplaceable portion of the sample train, extreme meteorological conditions, or other circumstances, beyond the owner or operator's control, compliance may, upon the Administrator's approval, be determined using the arithmetic mean of the results of the two other runs.

(2) Contents of report (electronic or paper submitted copy). Unless otherwise specified in a relevant standard or test method, or as otherwise approved by the Administrator in writing, the report for a performance test shall include the elements identified in paragraphs (f)(2)(i) through (vi) of this section.

(i) General identification information for the facility including a mailing address, the physical address, the owner or operator or responsible official (where applicable) and his/her email address, and the appropriate Federal Registry System (FRS) number for the facility.

(ii) Purpose of the test including the applicable regulation(s) requiring the test, the pollutant(s) and other parameters being measured, the applicable emission standard and any process parameter component, and a brief process description.

(iii) Description of the emission unit tested including fuel burned, control devices, and vent characteristics; the appropriate source classification code (SCC); the permitted maximum process rate (where applicable); and the sampling location.

(iv) Description of sampling and analysis procedures used and any modifications to standard procedures, quality assurance procedures and results, record of process operating conditions that demonstrate the applicable test conditions are met, and values for any operating parameters for which limits were being set during the test.

(v) Where a test method requires you record or report, the following shall be included: Record of preparation of standards, record of calibrations, raw data sheets for field sampling, raw data sheets for field and laboratory analyses, chain-of-custody documentation, and example calculations for reported results.

(vi) Identification of the company conducting the performance test including the primary office address, telephone number, and the contact for this test program including his/her email address.

(g) The performance testing shall include a test method performance audit (PA) during the performance test. The PAs consist of blind audit samples supplied by an accredited audit sample provider and analyzed during the performance test in order to provide a measure of test data bias. Gaseous audit samples are designed to audit the performance of the sampling system as well as the analytical system and must be collected by the sampling system during the compliance test just as the compliance samples are collected. If a liquid or solid audit sample is designed to audit the sampling system, it must also be collected by the sampling system during the compliance test. If multiple sampling systems or sampling trains are used during the compliance test for any of the test methods, the tester is only required to use one of the sampling systems per method to collect the audit sample. The audit sample must be analyzed by the same analyst using the same analytical reagents and analytical system and at the same time as the compliance samples. Retests are required when there is a failure to produce acceptable results for an audit sample. However, if the audit results do not affect the compliance or noncompliance status of the affected facility, the compliance authority may waive the reanalysis requirement, further audits, or retests and accept the results of the compliance test. Acceptance of the test results shall constitute a waiver of the reanalysis requirement, further audits, or retests. The compliance authority may also use the audit sample failure and the compliance test results as evidence to determine the compliance or noncompliance status of the affected facility. A blind audit sample is a sample whose value is known only to the sample provider and is not revealed to the tested facility until after they report the measured value of the audit sample. For pollutants that exist in the gas phase at ambient temperature, the audit sample shall consist of an appropriate concentration of the pollutant in air or nitrogen that can be introduced into the sampling system of the test method at or near the same entry point as a sample from the emission source. If no gas phase audit samples are available, an acceptable alternative is a sample of the pollutant in the same matrix that would be produced when the sample is recovered from the sampling system as required by the test method. For samples that exist only in a liquid or solid form at ambient temperature, the audit sample shall consist of an appropriate concentration of the pollutant in the same matrix that would be produced when the sample is recovered from the sampling system as required by the test method. An accredited audit sample provider (AASP) is an organization that has been accredited to prepare audit samples by an independent, third party accrediting body.

(1) The source owner, operator, or representative of the tested facility shall obtain an audit sample, if commercially available, from an AASP for each test method used for regulatory compliance purposes. No audit samples are required for the following test methods: Methods 3A and 3C of appendix A-3 of part 60, Methods 6C, 7E, 9, and 10 of appendix A-4 of part 60, Methods 18 and 19 of appendix A-6 of part 60, Methods 20, 22, and 25A of appendix A-7 of part 60, Methods 30A and 30B of appendix A-8 of part 60, and Methods 303, 318, 320, and 321 of appendix A of part 63 of this chapter. If multiple sources at a single facility are tested during a compliance test event, only one audit sample is required for each method used during a compliance test. The compliance authority responsible for the compliance test may waive the requirement to include an audit sample if they believe that an audit sample is not necessary. “Commercially available” means that two or more independent AASPs have blind audit samples available for purchase. If the source owner, operator, or representative cannot find an audit sample for a specific method, the owner, operator, or representative shall consult the EPA Web site at the following URL, www.epa.gov/ttn/emc, to confirm whether there is a source that can supply an audit sample for that method. If the EPA Web site does not list an available audit sample at least 60 days prior to the beginning of the compliance test, the source owner, operator, or representative shall not be required to include an audit sample as part of the quality assurance program for the compliance test. When ordering an audit sample, the source owner, operator, or representative shall give the sample provider an estimate for the concentration of each pollutant that is emitted by the source or the estimated concentration of each pollutant based on the permitted level and the name, address, and phone number of the compliance authority. The source owner, operator, or representative shall report the results for the audit sample along with a summary of the emission test results for the audited pollutant to the compliance authority and shall report the results of the audit sample to the AASP. The source owner, operator, or representative shall make both reports at the same time and in the same manner or shall report to the compliance authority first and then report to the AASP. If the method being audited is a method that allows the samples to be analyzed in the field and the tester plans to analyze the samples in the field, the tester may analyze the audit samples prior to collecting the emission samples provided a representative of the compliance authority is present at the testing site. The tester may request and the compliance authority may grant a waiver to the requirement that a representative of the compliance authority must be present at the testing site during the field analysis of an audit sample. The source owner, operator, or representative may report the results of the audit sample to the compliance authority and report the results of the audit sample to the AASP prior to collecting any emission samples. The test protocol and final test report shall document whether an audit sample was ordered and utilized and the pass/fail results as applicable.

(2) An AASP shall have and shall prepare, analyze, and report the true value of audit samples in accordance with a written technical criteria document that describes how audit samples will be prepared and distributed in a manner that will ensure the integrity of the audit sample program. An acceptable technical criteria document shall contain standard operating procedures for all of the following operations:

(i) Preparing the sample;

(ii) Confirming the true concentration of the sample;

(iii) Defining the acceptance limits for the results from a well qualified tester. This procedure must use well established statistical methods to analyze historical results from well qualified testers. The acceptance limits shall be set so that there is 95 percent confidence that 90 percent of well qualified labs will produce future results that are within the acceptance limit range.

(iv) Providing the opportunity for the compliance authority to comment on the selected concentration level for an audit sample;

(v) Distributing the sample to the user in a manner that guarantees that the true value of the sample is unknown to the user;

(vi) Recording the measured concentration reported by the user and determining if the measured value is within acceptable limits;

(vii) The AASP shall report the results from each audit sample in a timely manner to the compliance authority and then to the source owner, operator, or representative. The AASP shall make both reports at the same time and in the same manner or shall report to the compliance authority first and then report to the source owner, operator, or representative. The results shall include the name of the facility tested, the date on which the compliance test was conducted, the name of the company performing the sample collection, the name of the company that analyzed the compliance samples including the audit sample, the measured result for the audit sample, and whether the testing company passed or failed the audit. The AASP shall report the true value of the audit sample to the compliance authority. The AASP may report the true value to the source owner, operator, or representative if the AASP's operating plan ensures that no laboratory will receive the same audit sample twice.

(viii) Evaluating the acceptance limits of samples at least once every two years to determine in cooperation with the voluntary consensus standard body if they should be changed;

(ix) Maintaining a database, accessible to the compliance authorities, of results from the audit that shall include the name of the facility tested, the date on which the compliance test was conducted, the name of the company performing the sample collection, the name of the company that analyzed the compliance samples including the audit sample, the measured result for the audit sample, the true value of the audit sample, the acceptance range for the measured value, and whether the testing company passed or failed the audit.

(3) The accrediting body shall have a written technical criteria document that describes how it will ensure that the AASP is operating in accordance with the AASP technical criteria document that describes how audit samples are to be prepared and distributed. This document shall contain standard operating procedures for all of the following operations:

(i) Checking audit samples to confirm their true value as reported by the AASP;

(ii) Performing technical systems audits of the AASP's facilities and operating procedures at least once every two years;

(iii) Providing standards for use by the voluntary consensus standard body to approve the accrediting body that will accredit the audit sample providers.

(4) The technical criteria documents for the accredited sample providers and the accrediting body shall be developed through a public process guided by a voluntary consensus standards body (VCSB). The VCSB shall operate in accordance with the procedures and requirements in the Office of Management and Budget Circular A-119. A copy of Circular A-119 is available upon request by writing the Office of Information and Regulatory Affairs, Office of Management and Budget, 725 17th Street, NW., Washington, DC 20503, by calling (202) 395-6880 or downloading online at http://standards.gov/standards__gov/a119.cfm. The VCSB shall approve all accrediting bodies. The Administrator will review all technical criteria documents. If the technical criteria documents do not meet the minimum technical requirements in paragraphs (g)(2) through (4)of this section, the technical criteria documents are not acceptable and the proposed audit sample program is not capable of producing audit samples of sufficient quality to be used in a compliance test. All acceptable technical criteria documents shall be posted on the EPA Web site at the following URL, http://www.epa.gov/ttn/emc.

(h) Unless otherwise specified in the applicable subpart, each test location must be verified to be free of cyclonic flow and evaluated for the existence of emission gas stratification and the required number of sampling traverse points. If other procedures are not specified in the applicable subpart to the regulations, use the appropriate procedures in Method 1 to check for cyclonic flow and Method 7E to evaluate emission gas stratification and selection of sampling points.

(i) Whenever the use of multiple calibration gases is required by a test method, performance specification, or quality assurance procedure in a part 60 standard or appendix, Method 205 of 40 CFR part 51, appendix M of this chapter, “Verification of Gas Dilution Systems for Field Instrument Calibrations,” may be used.

§ 60.9Availability of information.

The availability to the public of information provided to, or otherwise obtained by, the Administrator under this part shall be governed by part 2 of this chapter. (Information submitted voluntarily to the Administrator for the purposes of §§ 60.5 and 60.6 is governed by §§ 2.201 through 2.213 of this chapter and not by § 2.301 of this chapter.)

§ 60.10State authority.

The provisions of this part shall not be construed in any manner to preclude any State or political subdivision thereof from:

(a) Adopting and enforcing any emission standard or limitation applicable to an affected facility, provided that such emission standard or limitation is not less stringent than the standard applicable to such facility.

(b) Requiring the owner or operator of an affected facility to obtain permits, licenses, or approvals prior to initiating construction, modification, or operation of such facility.

§ 60.11Compliance with standards and maintenance requirements.

(a) Compliance with standards in this part, other than opacity standards, shall be determined in accordance with performance tests established by § 60.8, unless otherwise specified in the applicable standard.

(b) Compliance with opacity standards in this part shall be determined by conducting observations in accordance with Method 9 in appendix A of this part, any alternative method that is approved by the Administrator, or as provided in paragraph (e)(5) of this section. For purposes of determining initial compliance, the minimum total time of observations shall be 3 hours (30 6-minute averages) for the performance test or other set of observations (meaning those fugitive-type emission sources subject only to an opacity standard).

(c) The opacity standards set forth in this part shall apply at all times except during periods of startup, shutdown, malfunction, and as otherwise provided in the applicable standard.

(d) At all times, including periods of startup, shutdown, and malfunction, owners and operators shall, to the extent practicable, maintain and operate any affected facility including associated air pollution control equipment in a manner consistent with good air pollution control practice for minimizing emissions. Determination of whether acceptable operating and maintenance procedures are being used will be based on information available to the Administrator which may include, but is not limited to, monitoring results, opacity observations, review of operating and maintenance procedures, and inspection of the source.

(e)(1) For the purpose of demonstrating initial compliance, opacity observations shall be conducted concurrently with the initial performance test required in § 60.8 unless one of the following conditions apply. If no performance test under § 60.8 is required, then opacity observations shall be conducted within 60 days after achieving the maximum production rate at which the affected facility will be operated but no later than 180 days after initial startup of the facility. If visibility or other conditions prevent the opacity observations from being conducted concurrently with the initial performance test required under § 60.8, the source owner or operator shall reschedule the opacity observations as soon after the initial performance test as possible, but not later than 30 days thereafter, and shall advise the Administrator of the rescheduled date. In these cases, the 30-day prior notification to the Administrator required in § 60.7(a)(6) shall be waived. The rescheduled opacity observations shall be conducted (to the extent possible) under the same operating conditions that existed during the initial performance test conducted under § 60.8. The visible emissions observer shall determine whether visibility or other conditions prevent the opacity observations from being made concurrently with the initial performance test in accordance with procedures contained in Method 9 of appendix B of this part. Opacity readings of portions of plumes which contain condensed, uncombined water vapor shall not be used for purposes of determing compliance with opacity standards. The owner or operator of an affected facility shall make available, upon request by the Administrator, such records as may be necessary to determine the conditions under which the visual observations were made and shall provide evidence indicating proof of current visible observer emission certification. Except as provided in paragraph (e)(5) of this section, the results of continuous monitoring by transmissometer which indicate that the opacity at the time visual observations were made was not in excess of the standard are probative but not conclusive evidence of the actual opacity of an emission, provided that the source shall meet the burden of proving that the instrument used meets (at the time of the alleged violation) Performance Specification 1 in appendix B of this part, has been properly maintained and (at the time of the alleged violation) that the resulting data have not been altered in any way.

(2) Except as provided in paragraph (e)(3) of this section, the owner or operator of an affected facility to which an opacity standard in this part applies shall conduct opacity observations in accordance with paragraph (b) of this section, shall record the opacity of emissions, and shall report to the Administrator the opacity results along with the results of the initial performance test required under § 60.8. The inability of an owner or operator to secure a visible emissions observer shall not be considered a reason for not conducting the opacity observations concurrent with the initial performance test.

(3) The owner or operator of an affected facility to which an opacity standard in this part applies may request the Administrator to determine and to record the opacity of emissions from the affected facility during the initial performance test and at such times as may be required. The owner or operator of the affected facility shall report the opacity results. Any request to the Administrator to determine and to record the opacity of emissions from an affected facility shall be included in the notification required in § 60.7(a)(6). If, for some reason, the Administrator cannot determine and record the opacity of emissions from the affected facility during the performance test, then the provisions of paragraph (e)(1) of this section shall apply.

(4) An owner or operator of an affected facility using a continuous opacity monitor (transmissometer) shall record the monitoring data produced during the initial performance test required by § 60.8 and shall furnish the Administrator a written report of the monitoring results along with Method 9 and § 60.8 performance test results.

(5) An owner or operator of an affected facility subject to an opacity standard may submit, for compliance purposes, continuous opacity monitoring system (COMS) data results produced during any performance test required under § 60.8 in lieu of Method 9 observation data. If an owner or operator elects to submit COMS data for compliance with the opacity standard, he shall notify the Administrator of that decision, in writing, at least 30 days before any performance test required under § 60.8 is conducted. Once the owner or operator of an affected facility has notified the Administrator to that effect, the COMS data results will be used to determine opacity compliance during subsequent tests required under § 60.8 until the owner or operator notifies the Administrator, in writing, to the contrary. For the purpose of determining compliance with the opacity standard during a performance test required under § 60.8 using COMS data, the minimum total time of COMS data collection shall be averages of all 6-minute continuous periods within the duration of the mass emission performance test. Results of the COMS opacity determinations shall be submitted along with the results of the performance test required under § 60.8. The owner or operator of an affected facility using a COMS for compliance purposes is responsible for demonstrating that the COMS meets the requirements specified in § 60.13(c) of this part, that the COMS has been properly maintained and operated, and that the resulting data have not been altered in any way. If COMS data results are submitted for compliance with the opacity standard for a period of time during which Method 9 data indicates noncompliance, the Method 9 data will be used to determine compliance with the opacity standard.

(6) Upon receipt from an owner or operator of the written reports of the results of the performance tests required by § 60.8, the opacity observation results and observer certification required by § 60.11(e)(1), and the COMS results, if applicable, the Administrator will make a finding concerning compliance with opacity and other applicable standards. If COMS data results are used to comply with an opacity standard, only those results are required to be submitted along with the performance test results required by § 60.8. If the Administrator finds that an affected facility is in compliance with all applicable standards for which performance tests are conducted in accordance with § 60.8 of this part but during the time such performance tests are being conducted fails to meet any applicable opacity standard, he shall notify the owner or operator and advise him that he may petition the Administrator within 10 days of receipt of notification to make appropriate adjustment to the opacity standard for the affected facility.

(7) The Administrator will grant such a petition upon a demonstration by the owner or operator that the affected facility and associated air pollution control equipment was operated and maintained in a manner to minimize the opacity of emissions during the performance tests; that the performance tests were performed under the conditions established by the Administrator; and that the affected facility and associated air pollution control equipment were incapable of being adjusted or operated to meet the applicable opacity standard.

(8) The Administrator will establish an opacity standard for the affected facility meeting the above requirements at a level at which the source will be able, as indicated by the performance and opacity tests, to meet the opacity standard at all times during which the source is meeting the mass or concentration emission standard. The Administrator will promulgate the new opacity standard in the Federal Register.

(f) Special provisions set forth under an applicable subpart shall supersede any conflicting provisions in paragraphs (a) through (e) of this section.

(g) For the purpose of submitting compliance certifications or establishing whether or not a person has violated or is in violation of any standard in this part, nothing in this part shall preclude the use, including the exclusive use, of any credible evidence or information, relevant to whether a source would have been in compliance with applicable requirements if the appropriate performance or compliance test or procedure had been performed.

§ 60.12Circumvention.

No owner or operator subject to the provisions of this part shall build, erect, install, or use any article, machine, equipment or process, the use of which conceals an emission which would otherwise constitute a violation of an applicable standard. Such concealment includes, but is not limited to, the use of gaseous diluents to achieve compliance with an opacity standard or with a standard which is based on the concentration of a pollutant in the gases discharged to the atmosphere.

§ 60.13Monitoring requirements.

(a) For the purposes of this section, all continuous monitoring systems required under applicable subparts shall be subject to the provisions of this section upon promulgation of performance specifications for continuous monitoring systems under appendix B to this part and, if the continuous monitoring system is used to demonstrate compliance with emission limits on a continuous basis, appendix F to this part, unless otherwise specified in an applicable subpart or by the Administrator. Appendix F is applicable December 4, 1987.

(b) All continuous monitoring systems and monitoring devices shall be installed and operational prior to conducting performance tests under § 60.8. Verification of operational status shall, as a minimum, include completion of the manufacturer's written requirements or recommendations for installation, operation, and calibration of the device.

(c) If the owner or operator of an affected facility elects to submit continous opacity monitoring system (COMS) data for compliance with the opacity standard as provided under § 60.11(e)(5), he shall conduct a performance evaluation of the COMS as specified in Performance Specification 1, appendix B, of this part before the performance test required under § 60.8 is conducted. Otherwise, the owner or operator of an affected facility shall conduct a performance evaluation of the COMS or continuous emission monitoring system (CEMS) during any performance test required under § 60.8 or within 30 days thereafter in accordance with the applicable performance specification in appendix B of this part, The owner or operator of an affected facility shall conduct COMS or CEMS performance evaluations at such other times as may be required by the Administrator under section 114 of the Act.

(1) The owner or operator of an affected facility using a COMS to determine opacity compliance during any performance test required under § 60.8 and as described in § 60.11(e)(5) shall furnish the Administrator two or, upon request, more copies of a written report of the results of the COMS performance evaluation described in paragraph (c) of this section at least 10 days before the performance test required under § 60.8 is conducted.

(2) Except as provided in paragraph (c)(1) of this section, the owner or operator of an affected facility shall furnish the Administrator within 60 days of completion two or, upon request, more copies of a written report of the results of the performance evaluation.

(d)(1) Owners and operators of a CEMS installed in accordance with the provisions of this part, must check the zero (or low level value between 0 and 20 percent of span value) and span (50 to 100 percent of span value) calibration drifts at least once each operating day in accordance with a written procedure. The zero and span must, at a minimum, be adjusted whenever either the 24-hour zero drift or the 24-hour span drift exceeds two times the limit of the applicable performance specification in appendix B of this part. The system must allow the amount of the excess zero and span drift to be recorded and quantified whenever specified. Owners and operators of a COMS installed in accordance with the provisions of this part must check the zero and upscale (span) calibration drifts at least once daily. For a particular COMS, the acceptable range of zero and upscale calibration materials is defined in the applicable version of PS-1 in appendix B of this part. For a COMS, the optical surfaces, exposed to the effluent gases, must be cleaned before performing the zero and upscale drift adjustments, except for systems using automatic zero adjustments. The optical surfaces must be cleaned when the cumulative automatic zero compensation exceeds 4 percent opacity.

(2) Unless otherwise approved by the Administrator, the following procedures must be followed for a COMS. Minimum procedures must include an automated method for producing a simulated zero opacity condition and an upscale opacity condition using a certified neutral density filter or other related technique to produce a known obstruction of the light beam. Such procedures must provide a system check of all active analyzer internal optics with power or curvature, all active electronic circuitry including the light source and photodetector assembly, and electronic or electro-mechanical systems and hardware and or software used during normal measurement operation.

(e) Except for system breakdowns, repairs, calibration checks, and zero and span adjustments required under paragraph (d) of this section, all continuous monitoring systems shall be in continuous operation and shall meet minimum frequency of operation requirements as follows:

(1) All continuous monitoring systems referenced by paragraph (c) of this section for measuring opacity of emissions shall complete a minimum of one cycle of sampling and analyzing for each successive 10-second period and one cycle of data recording for each successive 6-minute period.

(2) All continuous monitoring systems referenced by paragraph (c) of this section for measuring emissions, except opacity, shall complete a minimum of one cycle of operation (sampling, analyzing, and data recording) for each successive 15-minute period.

(f) All continuous monitoring systems or monitoring devices shall be installed such that representative measurements of emissions or process parameters from the affected facility are obtained. Additional procedures for location of continuous monitoring systems contained in the applicable Performance Specifications of appendix B of this part shall be used.

(g) When the effluents from a single affected facility or two or more affected facilities subject to the same emission standards are combined before being released to the atmosphere, the owner or operator may install applicable continuous monitoring systems on each effluent or on the combined effluent. When the affected facilities are not subject to the same emission standards, separate continuous monitoring systems shall be installed on each effluent. When the effluent from one affected facility is released to the atmosphere through more than one point, the owner or operator shall install an applicable continuous monitoring system on each separate effluent unless the installation of fewer systems is approved by the Administrator. When more than one continuous monitoring system is used to measure the emissions from one affected facility (e.g., multiple breechings, multiple outlets), the owner or operator shall report the results as required from each continuous monitoring system.

(h)(1) Owners or operators of all continuous monitoring systems for measurement of opacity shall reduce all data to 6-minute averages and for continuous monitoring systems other than opacity to 1-hour averages for time periods as defined in § 60.2. Six-minute opacity averages shall be calculated from 36 or more data points equally spaced over each 6-minute period.

(2) For continuous monitoring systems other than opacity, 1-hour averages shall be computed as follows, except that the provisions pertaining to the validation of partial operating hours are only applicable for affected facilities that are required by the applicable subpart to include partial hours in the emission calculations:

(i) Except as provided under paragraph (h)(2)(iii) of this section, for a full operating hour (any clock hour with 60 minutes of unit operation), at least four valid data points are required to calculate the hourly average, i.e. , one data point in each of the 15-minute quadrants of the hour.

(ii) Except as provided under paragraph (h)(2)(iii) of this section, for a partial operating hour (any clock hour with less than 60 minutes of unit operation), at least one valid data point in each 15-minute quadrant of the hour in which the unit operates is required to calculate the hourly average.

(iii) For any operating hour in which required maintenance or quality-assurance activities are performed:

(A) If the unit operates in two or more quadrants of the hour, a minimum of two valid data points, separated by at least 15 minutes, is required to calculate the hourly average; or

(B) If the unit operates in only one quadrant of the hour, at least one valid data point is required to calculate the hourly average.

(iv) If a daily calibration error check is failed during any operating hour, all data for that hour shall be invalidated, unless a subsequent calibration error test is passed in the same hour and the requirements of paragraph (h)(2)(iii) of this section are met, based solely on valid data recorded after the successful calibration.

(v) For each full or partial operating hour, all valid data points shall be used to calculate the hourly average.

(vi) Except as provided under paragraph (h)(2)(vii) of this section, data recorded during periods of continuous monitoring system breakdown, repair, calibration checks, and zero and span adjustments shall not be included in the data averages computed under this paragraph.

(vii) Owners and operators complying with the requirements of § 60.7(f)(1) or (2) must include any data recorded during periods of monitor breakdown or malfunction in the data averages.

(viii) When specified in an applicable subpart, hourly averages for certain partial operating hours shall not be computed or included in the emission averages (e.g., hours with < 30 minutes of unit operation under § 60.47b(d)).

(ix) Either arithmetic or integrated averaging of all data may be used to calculate the hourly averages. The data may be recorded in reduced or nonreduced form (e.g., ppm pollutant and percent O 2 or ng/J of pollutant).

(3) All excess emissions shall be converted into units of the standard using the applicable conversion procedures specified in the applicable subpart. After conversion into units of the standard, the data may be rounded to the same number of significant digits used in the applicable subpart to specify the emission limit.

(i) After receipt and consideration of written application, the Administrator may approve alternatives to any monitoring procedures or requirements of this part including, but not limited to the following:

(1) Alternative monitoring requirements when installation of a continuous monitoring system or monitoring device specified by this part would not provide accurate measurements due to liquid water or other interferences caused by substances in the effluent gases.

(2) Alternative monitoring requirements when the affected facility is infrequently operated.

(3) Alternative monitoring requirements to accommodate continuous monitoring systems that require additional measurements to correct for stack moisture conditions.

(4) Alternative locations for installing continuous monitoring systems or monitoring devices when the owner or operator can demonstrate that installation at alternate locations will enable accurate and representative measurements.

(5) Alternative methods of converting pollutant concentration measurements to units of the standards.

(6) Alternative procedures for performing daily checks of zero and span drift that do not involve use of span gases or test cells.

(7) Alternatives to the A.S.T.M. test methods or sampling procedures specified by any subpart.

(8) Alternative continuous monitoring systems that do not meet the design or performance requirements in Performance Specification 1, appendix B, but adequately demonstrate a definite and consistent relationship between its measurements and the measurements of opacity by a system complying with the requirements in Performance Specification 1. The Administrator may require that such demonstration be performed for each affected facility.

(9) Alternative monitoring requirements when the effluent from a single affected facility or the combined effluent from two or more affected facilities is released to the atmosphere through more than one point.

(j) An alternative to the relative accuracy (RA) test specified in Performance Specification 2 of appendix B may be requested as follows:

(1) An alternative to the reference method tests for determining RA is available for sources with emission rates demonstrated to be less than 50 percent of the applicable standard. A source owner or operator may petition the Administrator to waive the RA test in Section 8.4 of Performance Specification 2 and substitute the procedures in Section 16.0 if the results of a performance test conducted according to the requirements in § 60.8 of this subpart or other tests performed following the criteria in § 60.8 demonstrate that the emission rate of the pollutant of interest in the units of the applicable standard is less than 50 percent of the applicable standard. For sources subject to standards expressed as control efficiency levels, a source owner or operator may petition the Administrator to waive the RA test and substitute the procedures in Section 16.0 of Performance Specification 2 if the control device exhaust emission rate is less than 50 percent of the level needed to meet the control efficiency requirement. The alternative procedures do not apply if the continuous emission monitoring system is used to determine compliance continuously with the applicable standard. The petition to waive the RA test shall include a detailed description of the procedures to be applied. Included shall be location and procedure for conducting the alternative, the concentration or response levels of the alternative RA materials, and the other equipment checks included in the alternative procedure. The Administrator will review the petition for completeness and applicability. The determination to grant a waiver will depend on the intended use of the CEMS data (e.g., data collection purposes other than NSPS) and may require specifications more stringent than in Performance Specification 2 (e.g., the applicable emission limit is more stringent than NSPS).

(2) The waiver of a CEMS RA test will be reviewed and may be rescinded at such time, following successful completion of the alternative RA procedure, that the CEMS data indicate that the source emissions are approaching the level. The criterion for reviewing the waiver is the collection of CEMS data showing that emissions have exceeded 70 percent of the applicable standard for seven, consecutive, averaging periods as specified by the applicable regulation(s). For sources subject to standards expressed as control efficiency levels, the criterion for reviewing the waiver is the collection of CEMS data showing that exhaust emissions have exceeded 70 percent of the level needed to meet the control efficiency requirement for seven, consecutive, averaging periods as specified by the applicable regulation(s) [e.g., §§ 60.45(g) (2) and (3), 60.73(e), and 60.84(e)]. It is the responsibility of the source operator to maintain records and determine the level of emissions relative to the criterion on the waiver of RA testing. If this criterion is exceeded, the owner or operator must notify the Administrator within 10 days of such occurrence and include a description of the nature and cause of the increasing emissions. The Administrator will review the notification and may rescind the waiver and require the owner or operator to conduct a RA test of the CEMS as specified in Section 8.4 of Performance Specification 2.

§ 60.14Modification.

(a) Except as provided under paragraphs (e) and (f) of this section, any physical or operational change to an existing facility which results in an increase in the emission rate to the atmosphere of any pollutant to which a standard applies shall be considered a modification within the meaning of section 111 of the Act. Upon modification, an existing facility shall become an affected facility for each pollutant to which a standard applies and for which there is an increase in the emission rate to the atmosphere.

(b) Emission rate shall be expressed as kg/hr of any pollutant discharged into the atmosphere for which a standard is applicable. The Administrator shall use the following to determine emission rate:

(1) Emission factors as specified in the latest issue of “Compilation of Air Pollutant Emission Factors,” EPA Publication No. AP-42, or other emission factors determined by the Administrator to be superior to AP-42 emission factors, in cases where utilization of emission factors demonstrates that the emission level resulting from the physical or operational change will either clearly increase or clearly not increase.

(2) Material balances, continuous monitor data, or manual emission tests in cases where utilization of emission factors as referenced in paragraph (b)(1) of this section does not demonstrate to the Administrator's satisfaction whether the emission level resulting from the physical or operational change will either clearly increase or clearly not increase, or where an owner or operator demonstrates to the Administrator's satisfaction that there are reasonable grounds to dispute the result obtained by the Administrator utilizing emission factors as referenced in paragraph (b)(1) of this section. When the emission rate is based on results from manual emission tests or continuous monitoring systems, the procedures specified in appendix C of this part shall be used to determine whether an increase in emission rate has occurred. Tests shall be conducted under such conditions as the Administrator shall specify to the owner or operator based on representative performance of the facility. At least three valid test runs must be conducted before and at least three after the physical or operational change. All operating parameters which may affect emissions must be held constant to the maximum feasible degree for all test runs.

(c) The addition of an affected facility to a stationary source as an expansion to that source or as a replacement for an existing facility shall not by itself bring within the applicability of this part any other facility within that source.

(d) [Reserved]

(e) The following shall not, by themselves, be considered modifications under this part:

(1) Maintenance, repair, and replacement which the Administrator determines to be routine for a source category, subject to the provisions of paragraph (c) of this section and § 60.15.

(2) An increase in production rate of an existing facility, if that increase can be accomplished without a capital expenditure on that facility.

(3) An increase in the hours of operation.

(4) Use of an alternative fuel or raw material if, prior to the date any standard under this part becomes applicable to that source type, as provided by § 60.1, the existing facility was designed to accommodate that alternative use. A facility shall be considered to be designed to accommodate an alternative fuel or raw material if that use could be accomplished under the facility's construction specifications as amended prior to the change. Conversion to coal required for energy considerations, as specified in section 111(a)(8) of the Act, shall not be considered a modification.

(5) The addition or use of any system or device whose primary function is the reduction of air pollutants, except when an emission control system is removed or is replaced by a system which the Administrator determines to be less environmentally beneficial.

(6) The relocation or change in ownership of an existing facility.

(f) Special provisions set forth under an applicable subpart of this part shall supersede any conflicting provisions of this section.

(g) Within 180 days of the completion of any physical or operational change subject to the control measures specified in paragraph (a) of this section, compliance with all applicable standards must be achieved.

(h) No physical change, or change in the method of operation, at an existing electric utility steam generating unit shall be treated as a modification for the purposes of this section provided that such change does not increase the maximum hourly emissions of any pollutant regulated under this section above the maximum hourly emissions achievable at that unit during the 5 years prior to the change.

(i) Repowering projects that are awarded funding from the Department of Energy as permanent clean coal technology demonstration projects (or similar projects funded by EPA) are exempt from the requirements of this section provided that such change does not increase the maximum hourly emissions of any pollutant regulated under this section above the maximum hourly emissions achievable at that unit during the five years prior to the change.

(j)(1) Repowering projects that qualify for an extension under section 409(b) of the Clean Air Act are exempt from the requirements of this section, provided that such change does not increase the actual hourly emissions of any pollutant regulated under this section above the actual hourly emissions achievable at that unit during the 5 years prior to the change.

(2) This exemption shall not apply to any new unit that:

(i) Is designated as a replacement for an existing unit;

(ii) Qualifies under section 409(b) of the Clean Air Act for an extension of an emission limitation compliance date under section 405 of the Clean Air Act; and

(iii) Is located at a different site than the existing unit.

(k) The installation, operation, cessation, or removal of a temporary clean coal technology demonstration project is exempt from the requirements of this section. A temporary clean coal control technology demonstration project, for the purposes of this section is a clean coal technology demonstration project that is operated for a period of 5 years or less, and which complies with the State implementation plan for the State in which the project is located and other requirements necessary to attain and maintain the national ambient air quality standards during the project and after it is terminated.

(l) The reactivation of a very clean coal-fired electric utility steam generating unit is exempt from the requirements of this section.

§ 60.15Reconstruction.

(a) An existing facility, upon reconstruction, becomes an affected facility, irrespective of any change in emission rate.

(b) “Reconstruction” means the replacement of components of an existing facility to such an extent that:

(1) The fixed capital cost of the new components exceeds 50 percent of the fixed capital cost that would be required to construct a comparable entirely new facility, and

(2) It is technologically and economically feasible to meet the applicable standards set forth in this part.

(c) “Fixed capital cost” means the capital needed to provide all the depreciable components.

(d) If an owner or operator of an existing facility proposes to replace components, and the fixed capital cost of the new components exceeds 50 percent of the fixed capital cost that would be required to construct a comparable entirely new facility, he shall notify the Administrator of the proposed replacements. The notice must be postmarked 60 days (or as soon as practicable) before construction of the replacements is commenced and must include the following information:

(1) Name and address of the owner or operator.

(2) The location of the existing facility.

(3) A brief description of the existing facility and the components which are to be replaced.

(4) A description of the existing air pollution control equipment and the proposed air pollution control equipment.

(5) An estimate of the fixed capital cost of the replacements and of constructing a comparable entirely new facility.

(6) The estimated life of the existing facility after the replacements.

(7) A discussion of any economic or technical limitations the facility may have in complying with the applicable standards of performance after the proposed replacements.

(e) The Administrator will determine, within 30 days of the receipt of the notice required by paragraph (d) of this section and any additional information he may reasonably require, whether the proposed replacement constitutes reconstruction.

(f) The Administrator's determination under paragraph (e) shall be based on:

(1) The fixed capital cost of the replacements in comparison to the fixed capital cost that would be required to construct a comparable entirely new facility;

(2) The estimated life of the facility after the replacements compared to the life of a comparable entirely new facility;

(3) The extent to which the components being replaced cause or contribute to the emissions from the facility; and

(4) Any economic or technical limitations on compliance with applicable standards of performance which are inherent in the proposed replacements.

(g) Individual subparts of this part may include specific provisions which refine and delimit the concept of reconstruction set forth in this section.

§ 60.16Priority list.

Prioritized Major Source Categories

Priority Number 1

Source Category

1.

Synthetic Organic Chemical Manufacturing Industry (SOCMI) and Volatile Organic Liquid Storage Vessels and Handling Equipment

(a) SOCMI unit processes

(b) Volatile organic liquid (VOL) storage vessels and handling equipment

(c) SOCMI fugitive sources

(d) SOCMI secondary sources

2.

Industrial Surface Coating: Cans

3.

Petroleum Refineries: Fugitive Sources

4.

Industrial Surface Coating: Paper

5.

Dry Cleaning

(a) Perchloroethylene

(b) Petroleum solvent

6.

Graphic Arts

7.

Polymers and Resins: Acrylic Resins

8.

Mineral Wool (Deleted)

9.

Stationary Internal Combustion Engines

10.

Industrial Surface Coating: Fabric

11.

Industrial-Commercial-Institutional Steam Generating Units.

12.

Incineration: Non-Municipal (Deleted)

13.

Non-Metallic Mineral Processing

14.

Metallic Mineral Processing

15.

Secondary Copper (Deleted)

16.

Phosphate Rock Preparation

17.

Foundries: Steel and Gray Iron

18.

Polymers and Resins: Polyethylene

19.

Charcoal Production

20.

Synthetic Rubber

(a) Tire manufacture

(b) SBR production

21.

Vegetable Oil

22.

Industrial Surface Coating: Metal Coil

23.

Petroleum Transportation and Marketing

24.

By-Product Coke Ovens

25.

Synthetic Fibers

26.

Plywood Manufacture

27.

Industrial Surface Coating: Automobiles

28.

Industrial Surface Coating: Large Appliances

29.

Crude Oil and Natural Gas Production

30.

Secondary Aluminum

31.

Potash (Deleted)

32.

Lightweight Aggregate Industry: Clay, Shale, and Slate 2

33.

Glass

34.

Gypsum

35.

Sodium Carbonate

36.

Secondary Zinc (Deleted)

37.

Polymers and Resins: Phenolic

38.

Polymers and Resins: Urea-Melamine

39.

Ammonia (Deleted)

40.

Polymers and Resins: Polystyrene

41.

Polymers and Resins: ABS-SAN Resins

42.

Fiberglass

43.

Polymers and Resins: Polypropylene

44.

Textile Processing

45.

Asphalt Processing and Asphalt Roofing Manufacture

46.

Brick and Related Clay Products

47.

Ceramic Clay Manufacturing (Deleted)

48.

Ammonium Nitrate Fertilizer

49.

Castable Refractories (Deleted)

50.

Borax and Boric Acid (Deleted)

51.

Polymers and Resins: Polyester Resins

52.

Ammonium Sulfate

53.

Starch

54.

Perlite

55.

Phosphoric Acid: Thermal Process (Deleted)

56.

Uranium Refining

57.

Animal Feed Defluorination (Deleted)

58.

Urea (for fertilizer and polymers)

59.

Detergent (Deleted)

Other Source Categories

Lead acid battery manufacture 3

Organic solvent cleaning 3

Industrial surface coating: metal furniture 3

Stationary gas turbines 4

Municipal solid waste landfills 4

1 Low numbers have highest priority, e.g., No. 1 is high priority, No. 59 is low priority.

2 Formerly titled “Sintering: Clay and Fly Ash”.

3 Minor source category, but included on list since an NSPS is being developed for that source category.

4 Not prioritized, since an NSPS for this major source category has already been promulgated.

§ 60.17Incorporations by reference.

Link to an amendment published at 91 FR 11833, Mar. 10, 2026.

(a)(1) Certain material is incorporated by reference into this part with the approval of the Director of the Federal Register under 5 U.S.C. 552(a) and 1 CFR part 51. To enforce any edition other than that specified in this section, the U.S. Environmental Protection Agency (EPA) must publish a document in the Federal Register and the material must be available to the public. All approved incorporation by reference (IBR) material is available for inspection at the EPA and at the National Archives and Records Administration (NARA). Contact the EPA at: EPA Docket Center, Public Reading Room, EPA WJC West, Room 3334, 1301 Constitution Ave. NW, Washington, DC; phone: (202) 566-1744. For information on the availability of this material at NARA, visit www.archives.gov/federal-register/cfr/ibr-locations or email [email protected] .

(2) The IBR material may be obtained from the sources in the following paragraphs of this section or from one or more private resellers listed in this paragraph (a)(2). For material that is no longer commercially available, contact: the EPA (see paragraph (a)(1) of this section).

(i) Accuris Standards Store, 321 Inverness Drive, South Englewood, CO 80112; phone: (800) 332-6077; website: https://store.accuristech.com .

(ii) American National Standards Institute (ANSI), see paragraph (d) of this section.

(iii) GlobalSpec, 257 Fuller Road, Suite NFE 1100, Albany, NY 12203-3621; phone: (800) 261-2052; website: https://standards.globalspec.com .

(iv) Nimonik Document Center, 401 Roland Way, Suite 224, Oakland, CA 94624; phone (650) 591-7600; email: [email protected] ; website: www.document-center.com .

(v) Techstreet, phone: (855) 999-9870; email: [email protected] ; website: www.techstreet.com .

(b) American Gas Association, available through ILI Infodisk, 610 Winters Avenue, Paramus, New Jersey 07652:

(1) American Gas Association Report No. 3: Orifice Metering for Natural Gas and Other Related Hydrocarbon Fluids, Part 1: General Equations and Uncertainty Guidelines (1990), IBR approved for § 60.107a(d).

(2) American Gas Association Report No. 3: Orifice Metering for Natural Gas and Other Related Hydrocarbon Fluids, Part 2: Specification and Installation Requirements (2000), IBR approved for § 60.107a(d).

(3) American Gas Association Report No. 11: Measurement of Natural Gas by Coriolis Meter (2003), IBR approved for § 60.107a(d).

(4) American Gas Association Transmission Measurement Committee Report No. 7: Measurement of Gas by Turbine Meters (Revised February 2006), IBR approved for § 60.107a(d).

(c) American Hospital Association (AHA) Service, Inc., Post Office Box 92683, Chicago, Illinois 60675-2683.

(1) An Ounce of Prevention: Waste Reduction Strategies for Health Care Facilities. American Society for Health Care Environmental Services of the American Hospital Association. Chicago, Illinois. 1993. AHA Catalog No. 057007. ISBN 0-87258-673-5. IBR approved for §§ 60.35e and 60.55c.

(2) [Reserved]

(d) American National Standards Institute (ANSI), 25 West 43rd Street, Fourth Floor, New York, NY 10036-7417; phone: (212) 642-4980; email: [email protected] ; website: www.ansi.org .

(1) ANSI No. C12.20-2010 American National Standard for Electricity Meters—0.2 and 0.5 Accuracy Classes (Approved August 31, 2010); IBR approved for §§ 60.5535(d); 60.5535a(d); 60.5860b(a).

(2) [Reserved]

(e) American Petroleum Institute (API), 200 Massachusetts Ave. NW, Suite 1100, Washington, DC 20001; phone: (202) 682-8000; website: www.api.org .

(1) API Publication 2517, Evaporation Loss from External Floating Roof Tanks, Second Edition, February 1980, IBR approved for §§ 60.111(i), 60.111a(f), and 60.116b(e).

(2) API Manual of Petroleum Measurement Standards, Chapter 14—Natural Gas Fluids Measurement, Section 1—Collecting and Handling of Natural Gas Samples for Custody Transfer, 7th Edition, May 2016, IBR approved for § 60.4415(a).

(3) API Manual of Petroleum Measurement Standards, Chapter 22—Testing Protocol, Section 2—Differential Pressure Flow Measurement Devices, First Edition, August 2005, IBR approved for § 60.107a(d).

(f) American Public Health Association, 1015 18th Street NW., Washington, DC 20036.

(1) “Standard Methods for the Examination of Water and Wastewater,” 16th edition, 1985. Method 303F: “Determination of Mercury by the Cold Vapor Technique.” Incorporated by reference for appendix A-8 to part 60, Method 29, §§ 9.2.3, 10.3, and 11.1.3.

(2) 2540 G. Total, Fixed, and Volatile Solids in Solid and Semisolid Samples, in Standard Methods for the Examination of Water and Wastewater, 20th Edition, 1998, IBR approved for § 60.154(b).

(g) American Society of Mechanical Engineers (ASME), Two Park Avenue, New York, NY 10016-5990; phone: (800) 843-2763; email: [email protected]; website: www.asme.org.

(1) ASME Interim Supplement 19.5 on Instruments and Apparatus: Application, Part II of Fluid Meters, 6th Edition (1971), IBR approved for §§ 60.58a(h), 60.58b(i), 60.1320(a), and 60.1810(a).

(2) ASME MFC-3M-2004, Measurement of Fluid Flow in Pipes Using Orifice, Nozzle, and Venturi, IBR approved for § 60.107a(d).

(3) ASME/ANSI MFC-4M-1986 (Reaffirmed 2008), Measurement of Gas Flow by Turbine Meters, IBR approved for § 60.107a(d).

(4) ASME/ANSI MFC-5M-1985 (Reaffirmed 2006), Measurement of Liquid Flow in Closed Conduits Using Transit-Time Ultrasonic Flowmeters, IBR approved for § 60.107a(d).

(5) ASME MFC-6M-1998 (Reaffirmed 2005), Measurement of Fluid Flow in Pipes Using Vortex Flowmeters, IBR approved for § 60.107a(d).

(6) ASME/ANSI MFC-7M-1987 (Reaffirmed 2006), Measurement of Gas Flow by Means of Critical Flow Venturi Nozzles, IBR approved for § 60.107a(d).

(7) ASME/ANSI MFC-9M-1988 (Reaffirmed 2006), Measurement of Liquid Flow in Closed Conduits by Weighing Method, IBR approved for § 60.107a(d).

(8) ASME MFC-11M-2006, Measurement of Fluid Flow by Means of Coriolis Mass Flowmeters, IBR approved for § 60.107a(d).

(9) ASME MFC-14M-2003, Measurement of Fluid Flow Using Small Bore Precision Orifice Meters, IBR approved for § 60.107a(d).

(10) ASME MFC-16-2007, Measurement of Liquid Flow in Closed Conduits with Electromagnetic Flowmeters, IBR approved for § 60.107a(d).

(11) ASME MFC-18M-2001, Measurement of Fluid Flow Using Variable Area Meters, IBR approved for § 60.107a(d).

(12) ASME MFC-22-2007, Measurement of Liquid by Turbine Flowmeters, IBR approved for § 60.107a(d).

(13) ASME PTC 4.1-1964 (Reaffirmed 1991), Power Test Codes: Test Code for Steam Generating Units (with 1968 and 1969 Addenda), IBR approved for §§ 60.46b, 60.58a(h), 60.58b(i), 60.1320(a), and 60.1810(a).

(14) ASME/ANSI PTC 19.10-1981, Flue and Exhaust Gas Analyses [Part 10, Instruments and Apparatus], Issued August 31, 1981 IBR approved for §§ 60.56c(b); 60.63(f); 60.106(e); 60.104a(d), (h), (i), and (j); 60.105a(b), (d), (f), and (g); 60.106a(a); 60.107a(a), (c), (d), and e; 60.275(e); 60.275a(e); 60.275b(e); 60.285a(f); 60.396a(a); 60.614a(b); 60.664a(b); 60.704(b); 60.704a(b); 60.2145(s) and (t); 60.2710(s) and (t); 60.2922(e); 60.2940(c); tables 1, 1a, 1b, and 3 to subpart EEEE; §§ 60.3027(e); 60.3039(c); tables 2, 2a, and 4 to subpart FFFF; table 2 to subpart JJJJ; §§ 60.4415(a); 60.4900(b); tables 1 and 2 to subpart LLLL; § 60.5220(b); tables 2 and 3 to subpart MMMM; §§ 60.5406(c); 60.5413(b); 60.5406a(c); 60.5407a(g); 60.5413a(b) and (d); 60.5406b(c); 60.5407b(g); 60.5413b(b) and (d); 60.5413c(b) and (d).

(15) ASME PTC 22-2014, Gas Turbines: Performance Test Codes, (Issued December 31, 2014); IBR approved for §§ 60.5580; 60.5580a.

(16) ASME PTC 46-1996, Performance Test Code on Overall Plant Performance, (Issued October 15,1997); IBR approved for §§ 60.5580; 60.5580a.

(17) ASME QRO-1-1994, Standard for the Qualification and Certification of Resource Recovery Facility Operators, IBR approved for §§ 60.54b(a) and (b), 60.56a, 60.1185(a) and (c), and 60.1675(a) and (c).

(h) ASTM International, 100 Barr Harbor Drive, P.O. Box CB700, West Conshohocken, Pennsylvania 19428-2959; phone: (800) 262-1373; website: www.astm.org.

(1) ASTM A99-76, Standard Specification for Ferromanganese; IBR approved for § 60.261.

(2) ASTM A99-82 (Reapproved 1987), Standard Specification for Ferromanganese; IBR approved for § 60.261.

(3) ASTM A100-69, Standard Specification for Ferrosilicon; IBR approved for § 60.261.

(4) ASTM A100-74, Standard Specification for Ferrosilicon; IBR approved for § 60.261.

(5) ASTM A100-93, Standard Specification for Ferrosilicon; IBR approved for § 60.261.

(6) ASTM A101-73, Standard Specification for Ferrochromium; IBR approved for § 60.261.

(7) ASTM A101-93, Standard Specification for Ferrochromium; IBR approved for § 60.261.

(8) ASTM A482-76, Standard Specification for Ferrochromesilicon; IBR approved for § 60.261.

(9) ASTM A482-93, Standard Specification for Ferrochromesilicon; IBR approved for § 60.261.

(10) ASTM A483-64, Standard Specification for Silicomanganese; IBR approved for § 60.261.

(11) ASTM A483-74 (Reapproved 1988), Standard Specification for Silicomanganese; IBR approved for § 60.261.

(12) ASTM A495-76, Standard Specification for Calcium-Silicon and Calcium Manganese-Silicon; IBR approved for § 60.261.

(13) ASTM A495-94, Standard Specification for Calcium-Silicon and Calcium Manganese-Silicon; IBR approved for § 60.261.

(14) ASTM D86-78, Distillation of Petroleum Products; IBR approved for §§ 60.562-2(d); 60.593(d); 60.593a(d); 60.633(h).

(15) ASTM D86-82, Distillation of Petroleum Products; IBR approved for §§ 60.562-2(d); 60.593(d); 60.593a(d); 60.633(h).

(16) ASTM D86-90, Distillation of Petroleum Products; IBR approved for §§ 60.562-2(d); 60.593(d); 60.593a(d); 60.633(h).

(17) ASTM D86-93, Distillation of Petroleum Products; IBR approved for § 60.593a(d).

(18) ASTM D86-95, Distillation of Petroleum Products; IBR approved for §§ 60.562-2(d); 60.593(d); 60.593a(d); 60.633(h).

(19) ASTM D86-96, Distillation of Petroleum Products, approved April 10, 1996; IBR approved for §§ 60.562-2(d); 60.593(d); 60.593a(d); 60.633(h); 60.5401(f); 60.5401a(f); 60.5402b(d); 60.5402c(d).

(20) ASTM D129-64, Standard Test Method for Sulfur in Petroleum Products (General Bomb Method); IBR approved for § 60.106(j) and appendix A-7 to part 60: Method 19, Section 12.5.2.2.3.

(21) ASTM D129-78, Standard Test Method for Sulfur in Petroleum Products (General Bomb Method); IBR approved for § 60.106(j) and appendix A-7 to part 60: Method 19, Section 12.5.2.2.3.

(22) ASTM D129-95, Standard Test Method for Sulfur in Petroleum Products (General Bomb Method); IBR approved for § 60.106(j) and appendix A-7 to part 60: Method 19, Section 12.5.2.2.3.

(23) ASTM D129-00, Standard Test Method for Sulfur in Petroleum Products (General Bomb Method); IBR approved for § 60.335(b).

(24) ASTM D129-00 (Reapproved 2005), Standard Test Method for Sulfur in Petroleum Products (General Bomb Method); IBR Approved for §§ 60.4360a(c) and 60.4415(a).

(25) ASTM D240-76, Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb Calorimeter; IBR approved for §§ 60.46(c); 60.296(b); and appendix A-7 to part 60: Method 19, Section 12.5.2.2.3.

(26) ASTM D240-92, Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb Calorimeter; IBR approved for §§ 60.46(c); 60.296(b); and appendix A-7: Method 19, Section 12.5.2.2.3.

(27) ASTM D240-02 (Reapproved 2007), Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb Calorimeter, approved May 1, 2007; IBR approved for § 60.107a(d).

(28) ASTM D240-19, Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb Calorimeter, approved November 1, 2019; IBR approved for §§ 60.485b(g) and 60.4360a(c).

(29) ASTM D270-65, Standard Method of Sampling Petroleum and Petroleum Products; IBR approved for appendix A-7 to part 60: Method 19, Section 12.5.2.2.1.

(30) ASTM D270-75, Standard Method of Sampling Petroleum and Petroleum Products; IBR approved for appendix A-7 to part 60: Method 19, Section 12.5.2.2.1.

(31) ASTM D323-82, Test Method for Vapor Pressure of Petroleum Products (Reid Method); IBR approved for §§ 60.111(l); 60.111a(g); 60.111b; 60.116b(f).

(32) ASTM D323-94, Test Method for Vapor Pressure of Petroleum Products (Reid Method); IBR approved for §§ 60.111(l); 60.111a(g); 60.111b; 60.116b(f).

(33) ASTM D388-77, Standard Specification for Classification of Coals by Rank; IBR approved for §§ 60.41; 60.45(f); 60.41Da; 60.41b; 60.41c; 60.251.

(34) ASTM D388-90, Standard Specification for Classification of Coals by Rank; IBR approved for §§ 60.41; 60.45(f); 60.41Da; 60.41b; 60.41c; 60.251.

(35) ASTM D388-91, Standard Specification for Classification of Coals by Rank; IBR approved for §§ 60.41; 60.45(f); 60.41Da; 60.41b; 60.41c; 60.251.

(36) ASTM D388-95, Standard Specification for Classification of Coals by Rank; IBR approved for §§ 60.41; 60.45(f); 60.41Da; 60.41b; 60.41c; 60.251.

(37) ASTM D388-98a, Standard Specification for Classification of Coals by Rank; IBR approved for §§ 60.41; 60.45(f); 60.41Da; 60.41b; 60.41c; 60.251.

(38) ASTM D388-99 (Reapproved 2004)

1 (ASTM D388-99R04), Standard Classification of Coals by Rank, approved June 1, 2004; IBR approved for §§ 60.41; 60.45(f); 60.41Da; 60.41b; 60.41c; 60.251; 60.5580; 60.5580a.

(39) ASTM D396-78, Standard Specification for Fuel Oils; IBR approved for §§ 60.41b; 60.41c; 60.111(b); 60.111a(b).

(40) ASTM D396-89, Standard Specification for Fuel Oils; IBR approved for §§ 60.41b; 60.41c; 60.111(b); 60.111a(b).

(41) ASTM D396-90, Standard Specification for Fuel Oils; IBR approved for §§ 60.41b; 60.41c; 60.111(b); 60.111a(b).

(42) ASTM D396-92, Standard Specification for Fuel Oils; IBR approved for §§ 60.41b; 60.41c; 60.111(b); 60.111a(b).

(43) ASTM D396-98, Standard Specification for Fuel Oils, approved April 10, 1998; IBR approved for §§ 60.41b; 60.41c; 60.111(b); 60.111a(b); 60.4420a; 60.5580; 60.5580a.

(44) ASTM D975-78, Standard Specification for Diesel Fuel Oils; IBR approved for §§ 60.111(b) and 60.111a(b).

(45) ASTM D975-96, Standard Specification for Diesel Fuel Oils; IBR approved for §§ 60.111(b) and 60.111a(b).

(46) ASTM D975-98a, Standard Specification for Diesel Fuel Oils; IBR approved for §§ 60.111(b) and 60.111a(b).

(47) ASTM D975-08a, Standard Specification for Diesel Fuel Oils, approved October 1, 2008; IBR approved for §§ 60.41b; 60.41c; 60.4420a; 60.5580; 60.5580a.

(48) ASTM D1072-80, Standard Test Method for Total Sulfur in Fuel Gases; IBR approved for § 60.335(b).

(49) ASTM D1072-90 (Reapproved 1994), Standard Test Method for Total Sulfur in Fuel Gases; IBR approved for § 60.335(b).

(50) ASTM D1072-90 (Reapproved 1999), Standard Test Method for Total Sulfur in Fuel Gases; IBR approved for §§ 60.4360a(c) and 60.4415(a).

(51) ASTM D1137-53, Standard Method for Analysis of Natural Gases and Related Types of Gaseous Mixtures by the Mass Spectrometer; IBR approved for § 60.45(f).

(52) ASTM D1137-75, Standard Method for Analysis of Natural Gases and Related Types of Gaseous Mixtures by the Mass Spectrometer; IBR approved for § 60.45(f).

(53) ASTM D1193-77, Standard Specification for Reagent Water; IBR approved for appendix A-3 to part 60: Method 5, Section 7.1.3; Method 5E, Section 7.2.1; Method 5F, Section 7.2.1; appendix A-4 to part 60: Method 6, Section 7.1.1; Method 7, Section 7.1.1; Method 7C, Section 7.1.1; Method 7D, Section 7.1.1; Method 10A, Section 7.1.1; appendix A-5 to part 60: Method 11, Section 7.1.3; Method 12, Section 7.1.3; Method 13A, Section 7.1.2; appendix A-8 to part 60: Method 26, Section 7.1.2; Method 26A, Section 7.1.2; Method 29, Section 7.2.2.

(54) ASTM D1193-91, Standard Specification for Reagent Water; IBR approved for appendix A-3 to part 60: Method 5, Section 7.1.3; Method 5E, Section 7.2.1; Method 5F, Section 7.2.1; appendix A-4 to part 60: Method 6, Section 7.1.1; Method 7, Section 7.1.1; Method 7C, Section 7.1.1; Method 7D, Section 7.1.1; Method 10A, Section 7.1.1; appendix A-5 to part 60: Method 11, Section 7.1.3; Method 12, Section 7.1.3; Method 13A, Section 7.1.2; appendix A-8 to part 60: Method 26, Section 7.1.2; Method 26A, Section 7.1.2; Method 29, Section 7.2.2.

(55) ASTM D1266-87, Standard Test Method for Sulfur in Petroleum Products (Lamp Method); IBR approved for § 60.106(j).

(56) ASTM D1266-91, Standard Test Method for Sulfur in Petroleum Products (Lamp Method); IBR approved for § 60.106(j).

(57) ASTM D1266-98, Standard Test Method for Sulfur in Petroleum Products (Lamp Method); IBR approved for §§ 60.106(j) and 60.335(b).

(58) ASTM D1266-98 (Reapproved 2003) ε ,

1 Standard Test Method for Sulfur in Petroleum Products (Lamp Method); IBR approved for §§ 60.4360a(c) and 60.4415(a).

(59) ASTM D1475-60 (Reapproved 1980), Standard Test Method for Density of Paint, Varnish Lacquer, and Related Products; IBR approved for § 60.435(d), appendix A-7 to part 60: Method 24, Sections 6.1 and 11.3.3; Method 24A, Sections 6.5,7.1, 11.2, 11.3, and 16.0.

(60) ASTM D1475-90, Standard Test Method for Density of Paint, Varnish Lacquer, and Related Products; IBR approved for § 60.435(d); appendix A-7 to part 60: Method 24, Sections 6.1 and 11.3.3; Method 24A, Sections 6.5, 7.1, 11.2, 11.3, and 16.0.

(61) ASTM D1475-13, Standard Test Method for Density of Liquid Coatings, Inks, and Related Products, approved November 1, 2013; IBR approved for § 60.393a(f).

(62) ASTM D1552-83, Standard Test Method for Sulfur in Petroleum Products (High-Temperature Method); IBR approved for § 60.106(j) and appendix A-7 to part 60: Method 19, Section 12.5.2.2.3.

(63) ASTM D1552-95, Standard Test Method for Sulfur in Petroleum Products (High-Temperature Method); IBR approved for § 60.106(j) and appendix A-7 to part 60: Method 19, Section 12.5.2.2.3.

(64) ASTM D1552-01, Standard Test Method for Sulfur in Petroleum Products (High-Temperature Method; IBR approved for § 60.335(b).

(65) ASTM D1552-03, Standard Test Method for Sulfur in Petroleum Products (High-Temperature Method); IBR approved for §§ 60.4360a(c) and 60.4415(a).

(66) ASTM D1826-77, Standard Test Method for Calorific Value of Gases in Natural Gas Range by Continuous Recording Calorimeter; IBR approved for §§ 60.45(f); 60.46(c); 60.296(b); appendix A-7 to part 60: Method 19, Section 12.3.2.4.

(67) ASTM D1826-94, Standard Test Method for Calorific Value of Gases in Natural Gas Range by Continuous Recording Calorimeter; IBR approved for §§ 60.45(f); 60.46(c); 60.296(b); appendix A-7 to part 60: Method 19, Section 12.3.2.4.

(68) ASTM D1826-94 (Reapproved 2003), Standard Test Method for Calorific (Heating) Value of Gases in Natural Gas Range by Continuous Recording Calorimeter, approved May 10, 2003; IBR approved for §§ 60.107a(d) and 60.4360a(c).

(69) ASTM D1835-87, Standard Specification for Liquefied Petroleum (LP) Gases; IBR approved for §§ 60.41b; 60.41c.

(70) ASTM D1835-91, Standard Specification for Liquefied Petroleum (LP) Gases; IBR approved for §§ 60.41Da; 60.41b; 60.41c.

(71) ASTM D1835-97, Standard Specification for Liquefied Petroleum (LP) Gases; IBR approved for §§ 60.41Da; 60.41b; 60.41c.

(72) ASTM D1835-03a, Standard Specification for Liquefied Petroleum (LP) Gases; IBR approved for §§ 60.41Da; 60.41b; 60.41c; 60.4420a.

(73) ASTM D1945-64, Standard Method for Analysis of Natural Gas by Gas Chromatography; IBR approved for § 60.45(f).

(74) ASTM D1945-76, Standard Method for Analysis of Natural Gas by Gas Chromatography; IBR approved for § 60.45(f).

(75) ASTM D1945-91, Standard Method for Analysis of Natural Gas by Gas Chromatography; IBR approved for § 60.45(f).

(76) ASTM D1945-96, Standard Method for Analysis of Natural Gas by Gas Chromatography; IBR approved for § 60.45(f).

(77) ASTM D1945-03 (Reapproved 2010), Standard Method for Analysis of Natural Gas by Gas Chromatography, approved January 1, 2010; IBR approved for §§ 60.107a(d); 60.5413(d); 60.5413a(d); 60.5413b(d); 60.5413c(d).

(78) ASTM D1945-14 (Reapproved 2019), Standard Test Method for Analysis of Natural Gas by Gas Chromatography, approved December 1, 2019; IBR approved for § 60.485b(g).

(79) ASTM D1946-77, Standard Method for Analysis of Reformed Gas by Gas Chromatography; IBR approved for §§ 60.18(f); 60.45(f); 60.564(f); 60.614(e); 60.664(e); 60.704(d).

(80) ASTM D1946-90 (Reapproved 1994), Standard Method for Analysis of Reformed Gas by Gas Chromatography; IBR approved for §§ 60.18(f); 60.45(f); 60.564(f); 60.614(e); 60.664(e); 60.704(d).

(81) ASTM D1946-90 (Reapproved 2006), Standard Method for Analysis of Reformed Gas by Gas Chromatography, approved June 1, 2006; IBR approved for § 60.107a(d).

(82) ASTM D2013-72, Standard Method of Preparing Coal Samples for Analysis; IBR approved for appendix A-7 to part 60: Method 19, Section 12.5.2.1.3.

(83) ASTM D2013-86, Standard Method of Preparing Coal Samples for Analysis; IBR approved for appendix A-7 to part 60: Method 19, Section 12.5.2.1.3.

(84) ASTM D2015-77 (Reapproved 1978), Standard Test Method for Gross Calorific Value of Solid Fuel by the Adiabatic Bomb Calorimeter; IBR approved for §§ 60.45(f); 60.46(c); and appendix A-7 to part 60: Method 19, Section 12.5.2.1.3.

(85) ASTM D2015-96, Standard Test Method for Gross Calorific Value of Solid Fuel by the Adiabatic Bomb Calorimeter; IBR approved for §§ 60.45(f); 60.46(c); and appendix A-7 to part 60: Method 19, Section 12.5.2.1.3.

(86) ASTM D2016-74, Standard Test Methods for Moisture Content of Wood; IBR approved for appendix A-8 to part 60: Method 28, Section 16.1.1.

(87) ASTM D2016-83, Standard Test Methods for Moisture Content of Wood; IBR approved for appendix A-8 to part 60: Method 28, Section 16.1.1.

(88) ASTM D2234-76, Standard Methods for Collection of a Gross Sample of Coal; IBR approved for appendix A-7 to part 60: Method 19, Section 12.5.2.1.1.

(89) ASTM D2234-96, Standard Methods for Collection of a Gross Sample of Coal; IBR approved for appendix A-7 to part 60: Method 19, Section 12.5.2.1.1.

(90) ASTM D2234-97a, Standard Methods for Collection of a Gross Sample of Coal; IBR approved for appendix A-7 to part 60: Method 19, Section 12.5.2.1.1.

(91) ASTM D2234-98, Standard Methods for Collection of a Gross Sample of Coal; IBR approved for appendix A-7 to part 60: Method 19, Section 12.5.2.1.1.

(92) ASTM D2369-81, Standard Test Method for Volatile Content of Coatings; IBR approved for appendix A-7 to part 60: Method 24, Section 6.2.

(93) ASTM D2369-87, Standard Test Method for Volatile Content of Coatings; IBR approved for appendix A-7 to part 60: Method 24, Section 6.2.

(94) ASTM D2369-90, Standard Test Method for Volatile Content of Coatings; IBR approved for appendix A-7 to part 60: Method 24, Section 6.2.

(95) ASTM D2369-92, Standard Test Method for Volatile Content of Coatings; IBR approved for appendix A-7 to part 60: Method 24, Section 6.2.

(96) ASTM D2369-93, Standard Test Method for Volatile Content of Coatings; IBR approved for appendix A-7 to part 60: Method 24, Section 6.2.

(97) ASTM D2369-95, Standard Test Method for Volatile Content of Coatings; IBR approved for appendix A-7 to part 60: Method 24, Section 6.2.

(98) ASTM D2369-10 (Reapproved 2015)e1, Standard Test Method for Volatile Content of Coatings, approved June 1, 2015; IBR approved for appendix A-7 to part 60: Method 24, Section 6.2.

(99) ASTM D2369-20, Standard Test Method for Volatile Content of Coatings, approved June 1, 2020; IBR approved for §§ 60.393a(f); 60.723(b); 60.724(a); 60.725(b); 60.723a(b); 60.724a(a); 60.725a(b).

(100) ASTM D2382-76, Heat of Combustion of Hydrocarbon Fuels by Bomb Calorimeter (High-Precision Method); IBR approved for §§ 60.18(f); 60.485(g); 60.485a(g); 60.564(f); 60.664(e); 60.704(d).

(101) ASTM D2382-88, Heat of Combustion of Hydrocarbon Fuels by Bomb Calorimeter (High-Precision Method); IBR approved for §§ 60.18(f); 60.485(g); 60.485a(g); 60.564(f); 60.704(d).

(102) ASTM D2504-67, Noncondensable Gases in C3 and Lighter Hydrocarbon Products by Gas Chromatography; IBR approved for §§ 60.485(g) and 60.485a(g).

(103) ASTM D2504-77, Noncondensable Gases in C3 and Lighter Hydrocarbon Products by Gas Chromatography; IBR approved for §§ 60.485(g) and 60.485a(g).

(104) ASTM D2504-88 (Reapproved 1993), Noncondensable Gases in C3 and Lighter Hydrocarbon Products by Gas Chromatography; IBR approved for §§ 60.485(g) and 60.485a(g).

(105) ASTM D2584-68 (Reapproved 1985), Standard Test Method for Ignition Loss of Cured Reinforced Resins; IBR approved for § 60.685(c).

(106) ASTM D2584-94, Standard Test Method for Ignition Loss of Cured Reinforced Resins; IBR approved for § 60.685(c).

(107) ASTM D2597-94 (Reapproved 1999), Standard Test Method for Analysis of Demethanized Hydrocarbon Liquid Mixtures Containing Nitrogen and Carbon Dioxide by Gas Chromatography; IBR approved for § 60.335(b).

(108) ASTM D2622-87, Standard Test Method for Sulfur in Petroleum Products by Wavelength Dispersive X-Ray Fluorescence Spectrometry; IBR approved for § 60.106(j).

(109) ASTM D2622-94, Standard Test Method for Sulfur in Petroleum Products by Wavelength Dispersive X-Ray Fluorescence Spectrometry; IBR approved for § 60.106(j).

(110) ASTM D2622-98, Standard Test Method for Sulfur in Petroleum Products by Wavelength Dispersive X-Ray Fluorescence Spectrometry; IBR approved for §§ 60.106(j) and 60.335(b).

(111) ASTM D2622-05, Standard Test Method for Sulfur in Petroleum Products by Wavelength Dispersive X-Ray Fluorescence Spectrometry; IBR approved for §§ 60.4360a(c) and 60.4415(a).

(112) ASTM D2697-22, Standard Test Method for Volume Nonvolatile Matter in Clear or Pigmented Coatings, approved July 1, 2022; IBR approved for §§ 60.393a(g); 60.723(b); 60.724(a); 60.725(b); 60.723a(b); 60.724a(a); 60.725a(b).

(113) ASTM D2879-83, Test Method for Vapor Pressure-Temperature Relationship and Initial Decomposition Temperature of Liquids by Isoteniscope, approved 1983; IBR approved for §§ 60.111b; 60.116b(e) and (f); 60.485(e); 60.485a(e); 60.5403b(d); 60.5406c(d).

(114) ASTM D2879-96, Test Method for Vapor Pressure-Temperature Relationship and Initial Decomposition Temperature of Liquids by Isoteniscope, approved 1996; IBR approved for §§ 60.111b; 60.116b(e) and (f); 60.485(e); 60.485a(e); 60.5403b(d); 60.5406c(d).

(115) ASTM D2879-97, Test Method for Vapor Pressure-Temperature Relationship and Initial Decomposition Temperature of Liquids by Isoteniscope, approved 1997; IBR approved for §§ 60.111b; 60.116b(e) and (f); 60.485(e); 60.485a(e); 60.5403b(d); 60.5406c(d).

(116) ASTM D2879-23, Standard Test Method for Vapor Pressure-Temperature Relationship and Initial Decomposition Temperature of Liquids by Isoteniscope, approved December 1, 2019; IBR approved for § 60.485b(e).

(117) ASTM D2880-78, Standard Specification for Gas Turbine Fuel Oils; IBR approved for §§ 60.111(b) and 60.111a(b).

(118) ASTM D2880-96, Standard Specification for Gas Turbine Fuel Oils; IBR Approved for §§ 60.111(b) and 60.111a(b).

(119) ASTM D2908-74, Standard Practice for Measuring Volatile Organic Matter in Water by Aqueous-Injection Gas Chromatography; IBR approved for § 60.564(j).

(120) ASTM D2908-91, Standard Practice for Measuring Volatile Organic Matter in Water by Aqueous-Injection Gas Chromatography; IBR approved for § 60.564(j).

(121) ASTM D2986-71, Standard Method for Evaluation of Air, Assay Media by the Monodisperse DOP (Dioctyl Phthalate) Smoke Test; IBR approved for appendix A-3 to part 60: Method 5, Section 7.1.1; appendix A-5 to part 60: Method 12, Section 7.1.1; and Method 13A, Section 7.1.1.2.

(122) ASTM D2986-78, Standard Method for Evaluation of Air, Assay Media by the Monodisperse DOP (Dioctyl Phthalate) Smoke Test; IBR approved for appendix A-3 to part 60: Method 5, Section 7.1.1; appendix A-5 to part 60: Method 12, Section 7.1.1; and Method 13A, Section 7.1.1.2.

(123) ASTM D2986-95a, Standard Method for Evaluation of Air, Assay Media by the Monodisperse DOP (Dioctyl Phthalate) Smoke Test; IBR approved for appendix A-3 to part 60: Method 5, Section 7.1.1; appendix A-5 to part 60: Method 12, Section 7.1.1; and Method 13A, Section 7.1.1.2.

(124) ASTM D3173-73, Standard Test Method for Moisture in the Analysis Sample of Coal and Coke; IBR approved for appendix A-7 to part 60: Method 19, Section 12.5.2.1.3.

(125) ASTM D3173-87, Standard Test Method for Moisture in the Analysis Sample of Coal and Coke; IBR approved for appendix A-7 to part 60: Method 19, Section 12.5.2.1.3.

(126) ASTM D3176-74, Standard Method for Ultimate Analysis of Coal and Coke; IBR approved for § 60.45(f) and appendix A-7 to part 60: Method 19, Section 12.3.2.3.

(127) ASTM D3176-89, Standard Method for Ultimate Analysis of Coal and Coke; IBR approved for § 60.45(f) and appendix A-7 to part 60: Method 19, Section 12.3.2.3.

(128) ASTM D3177-75, Standard Test Method for Total Sulfur in the Analysis Sample of Coal and Coke; IBR approved for appendix A-7 to part 60: Method 19, Section 12.5.2.1.3.

(129) ASTM D3177-89, Standard Test Method for Total Sulfur in the Analysis Sample of Coal and Coke; IBR approved for appendix A-7 to part 60: Method 19, Section 12.5.2.1.3.

(130) ASTM D3178-73 (Reapproved 1979), Standard Test Methods for Carbon and Hydrogen in the Analysis Sample of Coal and Coke; IBR approved for § 60.45(f).

(131) ASTM D3178-89, Standard Test Methods for Carbon and Hydrogen in the Analysis Sample of Coal and Coke; IBR approved for § 60.45(f).

(132) ASTM D3246-81, Standard Test Method for Sulfur in Petroleum Gas by Oxidative Microcoulometry; IBR approved for § 60.335(b).

(133) ASTM D3246-92, Standard Test Method for Sulfur in Petroleum Gas by Oxidative Microcoulometry; IBR approved for § 60.335(b).

(134) ASTM D3246-96, Standard Test Method for Sulfur in Petroleum Gas by Oxidative Microcoulometry; IBR approved for § 60.335(b).

(135) ASTM D3246-05, Standard Test Method for Sulfur in Petroleum Gas by Oxidative Microcoulometry; IBR approved for §§ 60.4360a(c) and 60.4415(a).

(136) ASTM D3270-73T, Standard Test Methods for Analysis for Fluoride Content of the Atmosphere and Plant Tissues (Semiautomated Method); IBR approved for appendix A-5 to part 60: Method 13A, Section 16.1.

(137) ASTM D3270-80, Standard Test Methods for Analysis for Fluoride Content of the Atmosphere and Plant Tissues (Semiautomated Method); IBR approved for appendix A-5 to part 60: Method 13A, Section 16.1.

(138) ASTM D3270-91, Standard Test Methods for Analysis for Fluoride Content of the Atmosphere and Plant Tissues (Semiautomated Method); IBR approved for appendix A-5 to part 60: Method 13A, Section 16.1.

(139) ASTM D3270-95, Standard Test Methods for Analysis for Fluoride Content of the Atmosphere and Plant Tissues (Semiautomated Method); IBR approved for appendix A-5 to part 60: Method 13A, Section 16.1.

(140) ASTM D3286-85, Standard Test Method for Gross Calorific Value of Coal and Coke by the Isoperibol Bomb Calorimeter; IBR approved for appendix A-7 to part 60: Method 19, Section 12.5.2.1.3.

(141) ASTM D3286-96, Standard Test Method for Gross Calorific Value of Coal and Coke by the Isoperibol Bomb Calorimeter; IBR approved for appendix A-7 to part 60: Method 19, Section 12.5.2.1.3.

(142) ASTM D3370-76, Standard Practices for Sampling Water; IBR approved for § 60.564(j).

(143) ASTM D3370-95a, Standard Practices for Sampling Water; IBR approved for § 60.564(j).

(144) ASTM D3588-98 (Reapproved 2003), Standard Practice for Calculating Heat Value, Compressibility Factor, and Relative Density of Gaseous Fuels, approved May 10, 2003; IBR approved for §§ 60.107a(d); 60.4360a(c); 60.5413(d); 60.5413a(d); 60.5413b(d); 60.5413c(d).

(145) ASTM D3699-08, Standard Specification for Kerosine, including Appendix X1, approved September 1, 2008; IBR approved for §§ 60.41b; 60.41c; 60.4420a; 60.5580; 60.5580a.

(146) ASTM D3792-79, Standard Test Method for Water Content of Water-Reducible Paints by Direct Injection into a Gas Chromatograph; IBR approved for appendix A-7 to part 60: Method 24, Section 6.3.

(147) ASTM D3792-91, Standard Test Method for Water Content of Water-Reducible Paints by Direct Injection into a Gas Chromatograph; IBR approved for appendix A-7 to part 60: Method 24, Section 6.3.

(148) ASTM D4017-81, Standard Test Method for Water in Paints and Paint Materials by the Karl Fischer Titration Method; IBR approved for appendix A-7 to part 60: Method 24, Section 6.4.

(149) ASTM D4017-90, Standard Test Method for Water in Paints and Paint Materials by the Karl Fischer Titration Method; IBR approved for appendix A-7 to part 60: Method 24, Section 6.4.

(150) ASTM D4017-96a, Standard Test Method for Water in Paints and Paint Materials by the Karl Fischer Titration Method; IBR approved for appendix A-7 to part 60: Method 24, Section 6.4.

(151) ASTM D4057-81, Standard Practice for Manual Sampling of Petroleum and Petroleum Products; IBR approved for appendix A-7 to part 60: Method 19, Section 12.5.2.2.3.

(152) ASTM D4057-95, Standard Practice for Manual Sampling of Petroleum and Petroleum Products; IBR approved for appendix A-7 to part 60: Method 19, Section 12.5.2.2.3.

(153) ASTM D4057-95 (Reapproved 2000), Standard Practice for Manual Sampling of Petroleum and Petroleum Products; IBR approved for §§ 60.4360a(b) and 60.4415(a).

(154) ASTM D4084-82, Standard Test Method for Analysis of Hydrogen Sulfide in Gaseous Fuels (Lead Acetate Reaction Rate Method); IBR approved for § 60.334(h).

(155) ASTM D4084-94, Standard Test Method for Analysis of Hydrogen Sulfide in Gaseous Fuels (Lead Acetate Reaction Rate Method); IBR approved for § 60.334(h).

(156) ASTM D4084-05, Standard Test Method for Analysis of Hydrogen Sulfide in Gaseous Fuels (Lead Acetate Reaction Rate Method); IBR approved for §§ 60.4360; 60.4360a(c); 60.4415(a).

(157) ASTM D4177-95, Standard Practice for Automatic Sampling of Petroleum and Petroleum Products; IBR approved for appendix A-7 to part 60: Method 19, Section 12.5.2.2.1.

(158) ASTM D4177-95 (Reapproved 2000), Standard Practice for Automatic Sampling of Petroleum and Petroleum Products; IBR approved for §§ 60.4360a(b) and 60.4415(a).

(159) ASTM D4239-85, Standard Test Methods for Sulfur in the Analysis Sample of Coal and Coke Using High Temperature Tube Furnace Combustion Methods; IBR approved for appendix A-7 to part 60: Method 19, Section 12.5.2.1.3.

(160) ASTM D4239-94, Standard Test Methods for Sulfur in the Analysis Sample of Coal and Coke Using High Temperature Tube Furnace Combustion Methods; IBR approved for appendix A-7 to part 60: Method 19, Section 12.5.2.1.3.

(161) ASTM D4239-97, Standard Test Methods for Sulfur in the Analysis Sample of Coal and Coke Using High Temperature Tube Furnace Combustion Methods; IBR approved for appendix A-7 to part 60: Method 19, Section 12.5.2.1.3.

(162) ASTM D4294-02, Standard Test Method for Sulfur in Petroleum and Petroleum Products by Energy-Dispersive X-Ray Fluorescence Spectrometry; IBR approved for § 60.335(b).

(163) ASTM D4294-03, Standard Test Method for Sulfur in Petroleum and Petroleum Products by Energy-Dispersive X-Ray Fluorescence Spectrometry; IBR approved for §§ 60.4360a(c) and 60.4415(a).

(164) ASTM D4442-84, Standard Test Methods for Direct Moisture Content Measurement in Wood and Wood-base Materials; IBR approved for appendix A-8 to part 60: Method 28, Section 16.1.1.

(165) ASTM D4442-92, Standard Test Methods for Direct Moisture Content Measurement in Wood and Wood-base Materials; IBR approved for appendix A-8 to part 60: Method 28, Section 16.1.1.

(166) ASTM D4444-92, Standard Test Methods for Use and Calibration of Hand-Held Moisture Meters; IBR approved for appendix A-8 to part 60: Method 28, Section 16.1.1.

(167) ASTM D4457-85 (Reapproved 1991), Test Method for Determination of Dichloromethane and 1,1,1-Trichloroethane in Paints and Coatings by Direct Injection into a Gas Chromatograph; IBR approved for appendix A-7 to part 60: Method 24, Section 6.5.

(168) ASTM D4468-85 (Reapproved 2000), Standard Test Method for Total Sulfur in Gaseous Fuels by Hydrogenolysis and Rateometric Colorimetry; IBR approved for §§ 60.335(b); 60.4360a(c); 60.4415(a).

(169) ASTM D4468-85 (Reapproved 2006), Standard Test Method for Total Sulfur in Gaseous Fuels by Hydrogenolysis and Rateometric Colorimetry, approved June 1, 2006; IBR approved for § 60.107a(e).

(170) ASTM D4629-02, Standard Test Method for Trace Nitrogen in Liquid Petroleum Hydrocarbons by Syringe/Inlet Oxidative Combustion and Chemiluminescence Detection; IBR approved for §§ 60.49b(e) and 60.335(b).

(171) ASTM D4809-95, Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb Calorimeter (Precision Method); IBR approved for §§ 60.18(f); 60.485(g); 60.485a(g); 60.564(f); 60.704(d).

(172) ASTM D4809-06, Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb Calorimeter (Precision Method), approved December 1, 2006; IBR approved for § 60.107a(d).

(173) ASTM D4809-18, Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb Calorimeter (Precision Method), approved July 1, 2018; IBR approved for §§ 60.485b(g) and 60.4360a(c).

(174) ASTM D4810-88 (Reapproved 1999), Standard Test Method for Hydrogen Sulfide in Natural Gas Using Length of Stain Detector Tubes; IBR approved for §§ 60.4360; 60.4360a(c); 60.4415(a).

(175) ASTM D4840-99(2018)e1, Standard Guide for Sample Chain-of-Custody Procedures, approved August 2018; IBR approved for Appendix A-7: Method 23, Section 8.2.12.

(176) ASTM D4891-89 (Reapproved 2006), Standard Test Method for Heating Value of Gases in Natural Gas Range by Stoichiometric Combustion, approved June 1, 2006; IBR approved for §§ 60.107a(d); 60.4360a(c); 60.5413(d); 60.5413a(d); 60.5413b(d); 60.5413c(d).

(177) ASTM D5066-91 (Reapproved 2017), Standard Test Method for Determination of the Transfer Efficiency Under Production Conditions for Spray Application of Automotive Paints—Weight Basis, approved June 1, 2017; IBR approved for § 60.393a(h).

(178) ASTM D5087-02 (Reapproved 2021), Standard Test Method for Determining Amount of Volatile Organic Compound (VOC) Released from Solventborne Automotive Coatings and Available for Removal in a VOC Control Device (Abatement), approved February 1, 2021; IBR approved for § 60.397a(e) and appendix A to subpart MMa.

(179) ASTM D5287-97 (Reapproved 2002), Standard Practice for Automatic Sampling of Gaseous Fuels; IBR approved for §§ 60.4360a(b) and 60.4415(a).

(180) ASTM D5403-93, Standard Test Methods for Volatile Content of Radiation Curable Materials; IBR approved for appendix A-7 to part 60: Method 24, Section 6.6.

(181) ASTM D5453-00, Standard Test Method for Determination of Total Sulfur in Light Hydrocarbons, Motor Fuels and Oils by Ultraviolet Fluorescence; IBR approved for § 60.335(b).

(182) ASTM D5453-05, Standard Test Method for Determination of Total Sulfur in Light Hydrocarbons, Motor Fuels and Oils by Ultraviolet Fluorescence; IBR approved for §§ 60.4360a(c) and 60.4415(a).

(183) ASTM D5504-01, Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence; IBR approved for §§ 60.334(h) and 60.4360.

(184) ASTM D5504-08, Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence, approved June 15, 2008; IBR approved for § 60.107a(e).

(185) ASTM D5504-20, Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence, approved November 1, 2020; IBR approved for § 60.4360a(c).

(186) ASTM D5623-19, Standard Test Method for Sulfur Compounds in Light Petroleum Liquids by Gas Chromatography and Sulfur Selective Detection, approved July 1, 2019; IBR approved for § 60.4415(a).

(187) ASTM D5623-24, Standard Test Method for Sulfur Compounds in Light Petroleum Liquids by Gas Chromatography and Sulfur Selective Detection, approved March 1, 2024; IBR approved for § 60.4360a(c).

(188) ASTM D5762-02, Standard Test Method for Nitrogen in Petroleum and Petroleum Products by Boat-Inlet Chemiluminescence; IBR approved for § 60.335(b).

(189) ASTM D5865-98, Standard Test Method for Gross Calorific Value of Coal and Coke; IBR approved for §§ 60.45(f); 60.46(c); and appendix A-7 to part 60: Method 19, Section 12.5.2.1.3.

(190) ASTM D5865-10, Standard Test Method for Gross Calorific Value of Coal and Coke, approved January 1, 2010; IBR approved for §§ 60.45(f); 60.46(c); and appendix A-7 to part 60: Method 19, section 12.5.2.1.3.

(191) ASTM D5965-02 (Reapproved 2013), Standard Test Methods for Specific Gravity of Coating Powders, approved June 1, 2013; IBR approved for § 60.393a(f).

(192) ASTM D6093-97 (Reapproved 2016), Standard Test Method for Percent Volume Nonvolatile Matter in Clear or Pigmented Coatings Using a Helium Gas Pycnometer, approved December 1, 2016; IBR approved for §§ 60.393a(g); 60.723(b); 60.724(a); 60.725(b); 60.723a(b); 60.724a(a); 60.725a(b).

(193) ASTM D6216-20, Standard Practice for Opacity Monitor Manufacturers to Certify Conformance with Design and Performance Specifications, approved September 1, 2020; IBR approved for appendix B to part 60.

(194) ASTM D6228-98, Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Flame Photometric Detection; IBR approved for § 60.334(h).

(195) ASTM D6228-98 (Reapproved 2003), Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Flame Photometric Detection; IBR approved for §§ 60.4360; 60.4360a(c); 60.4415(a).

(196) ASTM D6266-00a (Reapproved 2017), Standard Test Method for Determining the Amount of Volatile Organic Compound (VOC) Released from Waterborne Automotive Coatings and Available for Removal in a VOC Control Device (Abatement), approved July 1, 2017; IBR approved for § 60.397a(e).

(197) ASTM D6348-03, Standard Test Method for Determination of Gaseous Compounds by Extractive Direct Interface Fourier Transform Infrared (FTIR) Spectroscopy, approved October 1, 2003; IBR approved for § 60.73a(b); table 7 to subpart IIII; table 2 to subpart JJJJ; § 60.4245(d).

(198) ASTM D6348-12e1, Standard Test Method for Determination of Gaseous Compounds by Extractive Direct Interface Fourier Transform Infrared (FTIR) Spectroscopy, approved February 1, 2012; IBR approved for § 60.5413c(b).

(199) ASTM D6348-12 (Reapproved 2020), Standard Test Method for Determination of Gaseous Compounds by Extractive Direct Interface Fourier Transform Infrared (FTIR) Spectroscopy, approved December 1, 2020; IBR approved for §§ 60.4400(a) and 60.4400a(b).

(200) ASTM D6366-99, Standard Test Method for Total Trace Nitrogen and Its Derivatives in Liquid Aromatic Hydrocarbons by Oxidative Combustion and Electrochemical Detection; IBR approved for § 60.335(b).

(201) ASTM D6377-20, Standard Test Method for Determination of Vapor Pressure of Crude Oil: VPCR X (Expansion Method), approved June 1, 2020; IBR approved for § 60.113c(d).

(202) ASTM D6378-22, Standard Test Method for Determination of Vapor Pressure (VPX) of Petroleum Products, Hydrocarbons, and Hydrocarbon-Oxygenate Mixtures (Triple Expansion Method), approved July 1, 2022; IBR approved for § 60.113c(d).

(203) ASTM D6420-99 (Reapproved 2004), Standard Test Method for Determination of Gaseous Organic Compounds by Direct Interface Gas Chromatography-Mass Spectrometry, approved October 1, 2004; IBR approved for § 60.107a(d).

(204) ASTM D6420-18, Standard Test Method for Determination of Gaseous Organic Compounds by Direct Interface Gas Chromatography-Mass Spectrometry, approved November 1, 2018; IBR approved for §§ 60.485(g); 60.485a(g); 60.485b(g); 60.611a; 60.614(b) and (e); 60.614a(b) and (e), 60.664(b) and (e); 60.664a(b) and (f); 60.700(c); 60.704(b) (d), and (h); 60.705(l); 60.704a(b) and (f).

(205) ASTM D6522-00, Standard Test Method for Determination of Nitrogen Oxides, Carbon Monoxide, and Oxygen Concentrations in Emissions from Natural Gas-Fired Reciprocating Engines, Combustion Turbines, Boilers, and Process Heaters Using Portable Analyzers; IBR approved for §§ 60.335(a) and (b).

(206) ASTM D6522-00 (Reapproved 2005), Standard Test Method for Determination of Nitrogen Oxides, Carbon Monoxide, and Oxygen Concentrations in Emissions from Natural Gas-Fired Reciprocating Engines, Combustion Turbines, Boilers, and Process Heaters Using Portable Analyzers, approved October 1, 2005; IBR approved for table 2 to subpart JJJJ, §§ 60.5413(b); 60.5413a(b).

(207) ASTM D6522-11 Standard Test Method for Determination of Nitrogen Oxides, Carbon Monoxide, and Oxygen Concentrations in Emissions from Natural Gas-Fired Reciprocating Engines, Combustion Turbines, Boilers, and Process Heaters Using Portable Analyzers, approved December 1, 2011; IBR approved for §§ 60.37f(a) and 60.766(a).

(208) ASTM D6522-20, Standard Test Method for Determination of Nitrogen Oxides, Carbon Monoxide, and Oxygen Concentrations in Emissions from Natural Gas-Fired Reciprocating Engines, Combustion Turbines, Boilers, and Process Heaters Using Portable Analyzers, approved June 1, 2020; IBR approved for §§ 60.4400(a); 60.4400a(b); 60.5413b(b); 60.5413c(b).

(209) ASTM D6667-01, Standard Test Method for Determination of Total Volatile Sulfur in Gaseous Hydrocarbons and Liquefied Petroleum Gases by Ultraviolet Fluorescence; IBR approved for § 60.335(b).

(210) ASTM D6667-04, Standard Test Method for Determination of Total Volatile Sulfur in Gaseous Hydrocarbons and Liquefied Petroleum Gases by Ultraviolet Fluorescence; IBR approved for §§ 60.4360a(c) and 60.4415(a).

(211) ASTM D6751-11b, Standard Specification for Biodiesel Fuel Blend Stock (B100) for Middle Distillate Fuels, including Appendices X1 through X3, approved July 15, 2011; IBR approved for §§ 60.41b; 60.41c; 60.4420a; 60.5580; 60.5580a.

(212) ASTM D6784-02, Standard Test Method for Elemental, Oxidized, Particle-Bound and Total Mercury in Flue Gas Generated from Coal-Fired Stationary Sources (Ontario Hydro Method); IBR approved for § 60.56c(b).

(213) ASTM D6784-02 (Reapproved 2008), Standard Test Method for Elemental, Oxidized, Particle-Bound and Total Mercury in Flue Gas Generated from Coal-Fired Stationary Sources (Ontario Hydro Method), approved April 1, 2008; IBR approved for § 60.56c(b).

(214) ASTM D6784-16, Standard Test Method for Elemental, Oxidized, Particle-Bound and Total Mercury in Flue Gas Generated from Coal-Fired Stationary Sources (Ontario Hydro Method), approved March 1, 2016; IBR approved for appendix B to part 60.

(215) ASTM D6911-15 Standard Guide for Packaging and Shipping Environmental Samples for Laboratory Analysis, approved January 15, 2015; IBR approved for Appendix A-7: Method 23, Section 8.2.11; Appendix A-8: Method 30B, Section 8.3.3.8.

(216) ASTM D7039-15a, Standard Test Method for Sulfur in Gasoline, Diesel Fuel, Jet Fuel, Kerosine, Biodiesel, Biodiesel Blends, and Gasoline-Ethanol Blends by Monochromatic Wavelength Dispersive X-ray Fluorescence Spectrometry, approved July 1, 2015; IBR approved for § 60.4415(a).

(217) ASTM D7039-24, Standard Test Method for Sulfur in Gasoline, Diesel Fuel, Jet Fuel, Kerosine, Biodiesel, Biodiesel Blends, and Gasoline-Ethanol Blends by Monochromatic Wavelength Dispersive X-ray Fluorescence Spectrometry, approved December 1, 2024; IBR approved for § 60.4360a(c).

(218) ASTM D7467-10, Standard Specification for Diesel Fuel Oil, Biodiesel Blend (B6 to B20), including Appendices X1 through X3, approved August 1, 2010; IBR approved for §§ 60.41b; 60.41c; 60.4420a; 60.5580; 60.5580a.

(219) ASTM D7520-16, Standard Test Method for Determining the Opacity of a Plume in the Outdoor Ambient Atmosphere, approved April 1, 2016; IBR approved for §§ 60.123(c); 60.123a(c); 60.271(k); 60.272(a) and (b); 60.273(c) and (d); 60.274(i); 60.275(e); 60.276(c); 60.271a; 60.272a(a) and (b); 60.273a(c) and (d); 60.274a(h); 60.275a(e); 60.276a(f); 60.271b; 60.272b(a) and (b); 60.273b(c) and (d); 60.274b(h); 60.275b(e); 60.276b(f); 60.374a(d); 60.2972(a); tables 1, 1a, and 1b to subpart EEEE; § 60.3067(a); tables 2 and 2a to subpart FFFF.

(220) ASTM E168-67, General Techniques of Infrared Quantitative Analysis; IBR approved for §§ 60.485a(d); 60.593(b); 60.593a(b); 60.632(f).

(221) ASTM E168-77, General Techniques of Infrared Quantitative Analysis; IBR approved for §§ 60.485a(d); 60.593(b); 60.593a(b); 60.632(f).

(222) ASTM E168-92, General Techniques of Infrared Quantitative Analysis; IBR approved for §§ 60.485a(d); 60.593(b); 60.593a(b); 60.632(f); 60.5400; 60.5400a(f).

(223) ASTM E168-16 (Reapproved 2023), Standard Practices for General Techniques of Infrared Quantitative Analysis, approved January 1, 2023; IBR approved for §§ 60.485b(d); 60.5400b(a); 60.5400c(a); 60.5401c(a).

(224) ASTM E169-63, General Techniques of Ultraviolet Quantitative Analysis; IBR approved for §§ 60.485a(d); 60.593(b); 60.593a(b); 60.632(f).

(225) ASTM E169-77, General Techniques of Ultraviolet Quantitative Analysis; IBR approved for §§ 60.485a(d); 60.593(b); 60.593a(b); 60.632(f).

(226) ASTM E169-93, General Techniques of Ultraviolet Quantitative Analysis, approved May 15, 1993; IBR approved for §§ 60.485a(d); 60.593(b); 60.593a(b); 60.632(f); 60.5400(f); 60.5400a(f).

(227) ASTM E169-16 (Reapproved 2022), Standard Practices for General Techniques of Ultraviolet-Visible Quantitative Analysis, approved November 1, 2022; IBR approved for § 60.485b(d), 60.5400b(a); 60.5401b(a); 60.5400c(a); 60.5401c(a).

(228) ASTM E260-73, General Gas Chromatography Procedures; IBR approved for §§ 60.485a(d); 60.593(b); 60.593a(b); 60.632(f).

(229) ASTM E260-91, General Gas Chromatography Procedures; IBR approved for §§ 60.485a(d); 60.593(b); 60.593a(b); 60.632(f).

(230) ASTM E260-96, General Gas Chromatography Procedures, approved April 10, 1996; IBR approved for §§ 60.485a(d); 60.593(b); 60.593a(b); 60.632(f); 60.5400(f); 60.5400a(f); 60.5406(b); 60.5406a(b)(3); 60.5400b(a)(2); 60.5401b(a)(2); 60.5406b(b)(3); 60.5400c(a); 60.5401c(a).

(231) ASTM E260-96 (Reapproved 2019), Standard Practice for Packed Column Gas Chromatography, approved September 1, 2019; IBR approved for § 60.485b(d).

(232) ASTM E617-13, Standard Specification for Laboratory Weights and Precision Mass Standards, approved May 1, 2013; IBR approved for appendix A-3: Methods 4, 5, 5H, 5I, and appendix A-8: Method 29.

(233) ASTM E871-82 (Reapproved 2013), Standard Test Method for Moisture Analysis of Particulate Wood Fuels, approved August 15, 2013; IBR approved for appendix A-8: Method 28R.

(234) ASTM E1584-11, Standard Test Method for Assay of Nitric Acid, approved August 1, 2011; IBR approved for § 60.73a(c).

(235) ASTM E2515-11, Standard Test Method for Determination of Particulate Matter Emissions Collected by a Dilution Tunnel, approved November 1, 2011; IBR approved for §§ 60.534(c) and (d); 60.5476(f).

(236) ASTM E2618-13 Standard Test Method for Measurement of Particulate Matter Emissions and Heating Efficiency of Outdoor Solid Fuel-Fired Hydronic Heating Appliances, approved September 1, 2013; IBR approved for § 60.5476(g).

(237) ASTM E2779-10, Standard Test Method for Determining Particulate Matter Emissions from Pellet Heaters, approved October 1, 2010; IBR approved for § 60.534(a) and (f).

(238) ASTM E2780-10, Standard Test Method for Determining Particulate Matter Emissions from Wood Heaters, approved October 1, 2010; IBR approved for appendix A: Method 28R.

(239) ASTM UOP539-97, Refinery Gas Analysis by Gas Chromatography, (Copyright 1997); IBR approved for § 60.107a(d).

(i) Association of Official Analytical Chemists, 1111 North 19th Street, Suite 210, Arlington, VA 22209; phone: (301) 927-7077; website: https://www.aoac.org/ .

(1) AOAC Method 9, Official Methods of Analysis of the Association of Official Analytical Chemists (AOAC), 11th edition, 1970, pp. 11-12, IBR approved for §§ 60.204(b), 60.214(b), 60.224(b), and 60.234(b).

(2) [Reserved]

(j) CSA Group (CSA) (formerly Canadian Standards Association), 178 Rexdale Boulevard, Toronto, Ontario, Canada; phone: (800) 463-6727; website: https://shop.csa.ca .

(1) CSA B415.1-10, Performance Testing of Solid-fuel-burning Heating Appliances, (March 2010), IBR approved for §§ 60.534; 60.5476.

(2) [Reserved]

(k) U.S. Environmental Protection Agency (EPA), 1200 Pennsylvania Avenue NW, Washington, DC 20460; phone: (202) 272-0167; website: www.epa.gov/aboutepa/forms/contact-epa .

(1) EPA-453/R-08-002, Protocol for Determining the Daily Volatile Organic Compound Emission Rate of Automobile and Light-Duty Truck Primer-Surfacer and Topcoat Operations, September 2008, Office of Air Quality Planning and Standards (OAQPS); IBR approved for §§ 60.393a(e) and (h); 60.395a(k); 60.397a(e); appendix A to subpart MMa.

(2) EPA-454/B-08-002, Quality Assurance Handbook for Air Pollution Measurement Systems; Volume IV: Meteorological Measurements, Version 2.0 (Final), March 2008; IBR approved for appendix K to this part.

(3) EPA-454/R-98-015, Office of Air Quality Planning and Standards (OAQPS), Fabric Filter Bag Leak Detection Guidance, September 1997; IBR approved for §§ 60.124(f); 60.124a(f); 60.273(e); 60.273a(e); 60.273b(e); 60.373a(b); 60.2145(r); 60.2710(r); 60.2944(c), 60.3043(c), 60.4880(b); 60.5200(b). (Available from: https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=2000D5T6.pdf ).

(4) EPA-600/R-12/531, EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards, May 2012; IBR approved for §§ 60.5413(d); 60.5413a(d); 60.5413b(d); 60.5413c(d).

(5) In EPA Publication No. SW-846, Test Methods for Evaluating Solid Waste, Physical/Chemical Methods (Available from: www.epa.gov/hw-sw846/sw-846-compendium ):

(i) SW-846-6010D, Inductively Coupled Plasma-Optical Emission Spectrometry, Revision 5, July 2018; IBR approved for appendix A-5 to this part.

(ii) SW-846-6020B, Inductively Coupled Plasma-Mass Spectrometry, Revision 2, July 2014; IBR approved for appendix A-5 to this part.

(l) European Standards (EN), European Committee for Standardization, Management Centre, Avenue Marnix 17, B-1000 Brussels, Belgium; phone: + 32 2 550 08 11; website: https://www.en-standard.eu .

(1) DIN EN 303-5:2012E (EN 303-5), Heating boilers—Part 5: Heating boilers for solid fuels, manually and automatically stoked, nominal heat output of up to 500 kW—Terminology, requirements, testing and marking, (October 2012), IBR approved for § 60.5476.

(2) [Reserved]

(m) GPA Midstream Association, 6060 American Plaza, Suite 700, Tulsa, OK 74135; phone: (918) 493-3872; website: www.gpamidstream.org .

(1) GPA Midstream Standard 2140-17 (GPA 2140-17), Liquified Petroleum Gas Specifications and Test Methods (Revised 2017); IBR approved for §§ 60.4360a(c) and 60.4415(a).

(2) GPA Midstream Standard 2166-17 (GPA 2166-17), Obtaining Natural Gas Samples for Analysis by Gas Chromatography, (Reaffirmed 2017); IBR approved for §§ 60.4360a(b) and 60.4415(a).

(3) GPA Standard 2172-09 (GPA 2172-09), Calculation of Gross Heating Value, Relative Density, Compressibility and Theoretical Hydrocarbon Liquid Content for Natural Gas Mixtures for Custody Transfer (2009); IBR approved for §§ 60.107a(d) and 60.4360a(c).

(4) GPA Standard 2174-14 (GPA 2174-14), Obtaining Liquid Hydrocarbon Samples for Analysis by Gas Chromatography, (Revised 2014); IBR

(5) GPA Standard 2261-19 (GPA 2261-19), Analysis for Natural Gas and Similar Gaseous Mixtures by Gas Chromatography, (Revised 2019), IBR approved for § 60.4415(a).

(6) GPA Standard 2377-86 (GPA 2377-84), Test for Hydrogen Sulfide and Carbon Dioxide in Natural Gas Using Length of Stain Tubes, 1986 Revision; IBR approved for §§ 60.105(b); 60.107a(b); 60.334(h); 60.4360; 60.4360a(c); and 60.4415(a).

(n) International Organization for Standardization (ISO), 1, ch. de la Voie-Creuse, Case postale 56, CH-1211 Geneva 20, Switzerland; phone: + 41 22 749 01 11; website: www.iso.org .

(1) ISO 8178-4: 1996(E), Reciprocating Internal Combustion Engines—Exhaust Emission Measurement—part 4: Test Cycles for Different Engine Applications, IBR approved for § 60.4241(b).

(2) ISO 2314:2009(E), Gas turbines-Acceptance tests, Third edition (December 15, 2009), IBR approved for §§ 60.5580; 60.5580a.

(3) ISO 8316: Measurement of Liquid Flow in Closed Conduits—Method by Collection of the Liquid in a Volumetric Tank (1987-10-01)—First Edition, IBR approved for § 60.107a(d).

(4) ISO 10715:1997(E), Natural gas—Sampling guidelines, (First Edition, June 1, 1997), IBR approved for § 60.4415(a).

(o) National Technical Information Services (NTIS), 5285 Port Royal Road, Springfield, Virginia 22161.

(1) OMB Bulletin No. 93-17: Revised Statistical Definitions for Metropolitan Areas. Office of Management and Budget, June 30, 1993. NTIS No. PB 93-192-664. IBR approved for § 60.31e.

(2) [Reserved]

(p) North American Electric Reliability Corporation, 1325 G Street NW., Suite 600, Washington, DC 20005-3801, http://www.nerc.com.

(1) North American Electric Reliability Corporation Reliability Standard EOP-002-3, Capacity and Energy Emergencies, updated November 19, 2012, IBR approved for §§ 60.4211(f) and 60.4243(d). Also available online: http://www.nerc.com/files/EOP-002-3__1.pdf.

(2) [Reserved]

(q) Pacific Lumber Inspection Bureau (formerly West Coast Lumber Inspection Bureau), 1010 South 336th Street #210, Federal Way, WA 98003; phone: (253) 835.3344; website: www.plib.org .

(1) West Coast Lumber Standard Grading Rules No. 16, pages 5-21, 90 and 91, September 3, 1970, revised 1984, IBR approved for appendix A-8 to part 60.

(2) [Reserved]

(r) Technical Association of the Pulp and Paper Industry (TAPPI), 15 Technology Parkway South, Suite 115, Peachtree Corners, GA 30092; phone (800) 332-8686; website: www.tappi.org.

(1) TAPPI Method T 624 cm-11, (Copyright 2011), IBR approved, for §§ 60.285(d) and 60.285a(d).

(2) [Reserved]

(s) Underwriter's Laboratories, Inc. (UL), 333 Pfingsten Road, Northbrook, IL 60062.

(1) UL 103, Sixth Edition revised as of September 3, 1986, Standard for Chimneys, Factory-built, Residential Type and Building Heating Appliance, IBR approved for appendix A-8 to part 60.

(2) [Reserved]

(t) Water Pollution Control Federation (WPCF), 2626 Pennsylvania Avenue NW., Washington, DC 20037.

(1) Method 209A, Total Residue Dried at 103-105 °C, in Standard Methods for the Examination of Water and Wastewater, 15th Edition, 1980, IBR approved for § 60.683(b).

(2) [Reserved]

§ 60.18General control device and work practice requirements.

(a) Introduction. (1) This section contains requirements for control devices used to comply with applicable subparts of 40 CFR parts 60 and 61. The requirements are placed here for administrative convenience and apply only to facilities covered by subparts referring to this section.

(2) This section also contains requirements for an alternative work practice used to identify leaking equipment. This alternative work practice is placed here for administrative convenience and is available to all subparts in 40 CFR parts 60, 61, 63, and 65 that require monitoring of equipment with a 40 CFR part 60, appendix A-7, Method 21 monitor.

(b) Flares. Paragraphs (c) through (f) apply to flares.

(c)(1) Flares shall be designed for and operated with no visible emissions as determined by the methods specified in paragraph (f), except for periods not to exceed a total of 5 minutes during any 2 consecutive hours.

(2) Flares shall be operated with a flame present at all times, as determined by the methods specified in paragraph (f).

(3) An owner/operator has the choice of adhering to either the heat content specifications in paragraph (c)(3)(ii) of this section and the maximum tip velocity specifications in paragraph (c)(4) of this section, or adhering to the requirements in paragraph (c)(3)(i) of this section.

(i)(A) Flares shall be used that have a diameter of 3 inches or greater, are nonassisted, have a hydrogen content of 8.0 percent (by volume), or greater, and are designed for and operated with an exit velocity less than 37.2 m/sec (122 ft/sec) and less than the velocity, V max , as determined by the following equation:

V max = (X H2 −K 1 )* K 2

Where:

V max = Maximum permitted velocity, m/sec.

K 1 = Constant, 6.0 volume-percent hydrogen.

K 2 = Constant, 3.9(m/sec)/volume-percent hydrogen.

X H2 = The volume-percent of hydrogen, on a wet basis, as calculated by using the American Society for Testing and Materials (ASTM) Method D1946-77. (Incorporated by reference as specified in § 60.17).

(B) The actual exit velocity of a flare shall be determined by the method specified in paragraph (f)(4) of this section.

(ii) Flares shall be used only with the net heating value of the gas being combusted being 11.2 MJ/scm (300 Btu/scf) or greater if the flare is steam-assisted or air-assisted; or with the net heating value of the gas being combusted being 7.45 MJ/scm (200 Btu/scf) or greater if the flare is nonassisted. The net heating value of the gas being combusted shall be determined by the methods specified in paragraph (f)(3) of this section.

(4)(i) Steam-assisted and nonassisted flares shall be designed for and operated with an exit velocity, as determined by the methods specified in paragraph (f)(4) of this section, less than 18.3 m/sec (60 ft/sec), except as provided in paragraphs (c)(4) (ii) and (iii) of this section.

(ii) Steam-assisted and nonassisted flares designed for and operated with an exit velocity, as determined by the methods specified in paragraph (f)(4), equal to or greater than 18.3 m/sec (60 ft/sec) but less than 122 m/sec (400 ft/sec) are allowed if the net heating value of the gas being combusted is greater than 37.3 MJ/scm (1,000 Btu/scf).

(iii) Steam-assisted and nonassisted flares designed for and operated with an exit velocity, as determined by the methods specified in paragraph (f)(4), less than the velocity, V max , as determined by the method specified in paragraph (f)(5), and less than 122 m/sec (400 ft/sec) are allowed.

(5) Air-assisted flares shall be designed and operated with an exit velocity less than the velocity, V max , as determined by the method specified in paragraph (f)(6).

(6) Flares used to comply with this section shall be steam-assisted, air-assisted, or nonassisted.

(d) Owners or operators of flares used to comply with the provisions of this subpart shall monitor these control devices to ensure that they are operated and maintained in conformance with their designs. Applicable subparts will provide provisions stating how owners or operators of flares shall monitor these control devices.

(e) Flares used to comply with provisions of this subpart shall be operated at all times when emissions may be vented to them.

(f)(1) Method 22 of appendix A to this part shall be used to determine the compliance of flares with the visible emission provisions of this subpart. The observation period is 2 hours and shall be used according to Method 22.

(2) The presence of a flare pilot flame shall be monitored using a thermocouple or any other equivalent device to detect the presence of a flame.

(3) The net heating value of the gas being combusted in a flare shall be calculated using the following equation:

where:

H T = Net heating value of the sample, MJ/scm; where the net enthalpy per mole of offgas is based on combustion at 25 °C and 760 mm Hg, but the standard temperature for determining the volume corresponding to one mole is 20 °C;

C i = Concentration of sample component i in ppm on a wet basis, as measured for organics by Reference Method 18 and measured for hydrogen and carbon monoxide by ASTM D1946-77 or 90 (Reapproved 1994) (Incorporated by reference as specified in § 60.17); and

H i = Net heat of combustion of sample component i, kcal/g mole at 25 °C and 760 mm Hg. The heats of combustion may be determined using ASTM D2382-76 or 88 or D4809-95 (incorporated by reference as specified in § 60.17) if published values are not available or cannot be calculated.

(4) The actual exit velocity of a flare shall be determined by dividing the volumetric flowrate (in units of standard temperature and pressure), as determined by Reference Methods 2, 2A, 2C, or 2D as appropriate; by the unobstructed (free) cross sectional area of the flare tip.

(5) The maximum permitted velocity, V max , for flares complying with paragraph (c)(4)(iii) shall be determined by the following equation.

Log 10 (V max ) = (H T + 28.8)/31.7

V max = Maximum permitted velocity, M/sec

28.8 = Constant

31.7 = Constant

H T = The net heating value as determined in paragraph (f)(3).

(6) The maximum permitted velocity, V max , for air-assisted flares shall be determined by the following equation.

V max = 8.706 + 0.7084 (H T )

V max = Maximum permitted velocity, m/sec

8.706 = Constant

0.7084 = Constant

H T = The net heating value as determined in paragraph (f)(3).

(g) Alternative work practice for monitoring equipment for leaks. Paragraphs (g), (h), and (i) of this section apply to all equipment for which the applicable subpart requires monitoring with a 40 CFR part 60, appendix A-7, Method 21 monitor, except for closed vent systems, equipment designated as leakless, and equipment identified in the applicable subpart as having no detectable emissions, as indicated by an instrument reading of less than 500 ppm above background. An owner or operator may use an optical gas imaging instrument instead of a 40 CFR part 60, appendix A-7, Method 21 monitor. Requirements in the existing subparts that are specific to the Method 21 instrument do not apply under this section. All other requirements in the applicable subpart that are not addressed in paragraphs (g), (h), and (i) of this section apply to this standard. For example, equipment specification requirements, and non-Method 21 instrument recordkeeping and reporting requirements in the applicable subpart continue to apply. The terms defined in paragraphs (g)(1) through (5) of this section have meanings that are specific to the alternative work practice standard in paragraphs (g), (h), and (i) of this section.

(1) Applicable subpart means the subpart in 40 CFR parts 60, 61, 63, or 65 that requires monitoring of equipment with a 40 CFR part 60, appendix A-7, Method 21 monitor.

(2) Equipment means pumps, valves, pressure relief valves, compressors, open-ended lines, flanges, connectors, and other equipment covered by the applicable subpart that require monitoring with a 40 CFR part 60, appendix A-7, Method 21 monitor.

(3) Imaging means making visible emissions that may otherwise be invisible to the naked eye.

(4) Optical gas imaging instrument means an instrument that makes visible emissions that may otherwise be invisible to the naked eye.

(5) Repair means that equipment is adjusted, or otherwise altered, in order to eliminate a leak.

(6) Leak means:

(i) Any emissions imaged by the optical gas instrument;

(ii) Indications of liquids dripping;

(iii) Indications by a sensor that a seal or barrier fluid system has failed; or

(iv) Screening results using a 40 CFR part 60, appendix A-7, Method 21 monitor that exceed the leak definition in the applicable subpart to which the equipment is subject.

(h) The alternative work practice standard for monitoring equipment for leaks is available to all subparts in 40 CFR parts 60, 61, 63, and 65 that require monitoring of equipment with a 40 CFR part 60, appendix A-7, Method 21 monitor.

(1) An owner or operator of an affected source subject to CFR parts 60, 61, 63, or 65 can choose to comply with the alternative work practice requirements in paragraph (i) of this section instead of using the 40 CFR part 60, appendix A-7, Method 21 monitor to identify leaking equipment. The owner or operator must document the equipment, process units, and facilities for which the alternative work practice will be used to identify leaks.

(2) Any leak detected when following the leak survey procedure in paragraph (i)(3) of this section must be identified for repair as required in the applicable subpart.

(3) If the alternative work practice is used to identify leaks, re-screening after an attempted repair of leaking equipment must be conducted using either the alternative work practice or the 40 CFR part 60, appendix A-7, Method 21 monitor at the leak definition required in the applicable subpart to which the equipment is subject.

(4) The schedule for repair is as required in the applicable subpart.

(5) When this alternative work practice is used for detecting leaking equipment, choose one of the monitoring frequencies listed in Table 1 to subpart A of this part in lieu of the monitoring frequency specified for regulated equipment in the applicable subpart. Reduced monitoring frequencies for good performance are not applicable when using the alternative work practice.

(6) When this alternative work practice is used for detecting leaking equipment the following are not applicable for the equipment being monitored:

(i) Skip period leak detection and repair;

(ii) Quality improvement plans; or

(iii) Complying with standards for allowable percentage of valves and pumps to leak.

(7) When the alternative work practice is used to detect leaking equipment, the regulated equipment in paragraph (h)(1)(i) of this section must also be monitored annually using a 40 CFR part 60, appendix A-7, Method 21 monitor at the leak definition required in the applicable subpart. The owner or operator may choose the specific monitoring period (for example, first quarter) to conduct the annual monitoring. Subsequent monitoring must be conducted every 12 months from the initial period. Owners or operators must keep records of the annual Method 21 screening results, as specified in paragraph (i)(4)(vii) of this section.

(i) An owner or operator of an affected source who chooses to use the alternative work practice must comply with the requirements of paragraphs (i)(1) through (i)(5) of this section.

(1) Instrument Specifications. The optical gas imaging instrument must comply with the requirements in (i)(1)(i) and (i)(1)(ii) of this section.

(i) Provide the operator with an image of the potential leak points for each piece of equipment at both the detection sensitivity level and within the distance used in the daily instrument check described in paragraph (i)(2) of this section. The detection sensitivity level depends upon the frequency at which leak monitoring is to be performed.

(ii) Provide a date and time stamp for video records of every monitoring event.

(2) Daily Instrument Check. On a daily basis, and prior to beginning any leak monitoring work, test the optical gas imaging instrument at the mass flow rate determined in paragraph (i)(2)(i) of this section in accordance with the procedure specified in paragraphs (i)(2)(ii) through (i)(2)(iv) of this section for each camera configuration used during monitoring (for example, different lenses used), unless an alternative method to demonstrate daily instrument checks has been approved in accordance with paragraph (i)(2)(v) of this section.

(i) Calculate the mass flow rate to be used in the daily instrument check by following the procedures in paragraphs (i)(2)(i)(A) and (i)(2)(i)(B) of this section.

(A) For a specified population of equipment to be imaged by the instrument, determine the piece of equipment in contact with the lowest mass fraction of chemicals that are detectable, within the distance to be used in paragraph (i)(2)(iv)(B) of this section, at or below the standard detection sensitivity level.

(B) Multiply the standard detection sensitivity level, corresponding to the selected monitoring frequency in Table 1 of subpart A of this part, by the mass fraction of detectable chemicals from the stream identified in paragraph (i)(2)(i)(A) of this section to determine the mass flow rate to be used in the daily instrument check, using the following equation.

Where:

E dic = Mass flow rate for the daily instrument check, grams per hour

x i = Mass fraction of detectable chemical(s) i seen by the optical gas imaging instrument, within the distance to be used in paragraph (i)(2)(iv)(B) of this section, at or below the standard detection sensitivity level, E sds .

E sds = Standard detection sensitivity level from Table 1 to subpart A, grams per hour

k = Total number of detectable chemicals emitted from the leaking equipment and seen by the optical gas imaging instrument.

(ii) Start the optical gas imaging instrument according to the manufacturer's instructions, ensuring that all appropriate settings conform to the manufacturer's instructions.

(iii) Use any gas chosen by the user that can be viewed by the optical gas imaging instrument and that has a purity of no less than 98 percent.

(iv) Establish a mass flow rate by using the following procedures:

(A) Provide a source of gas where it will be in the field of view of the optical gas imaging instrument.

(B) Set up the optical gas imaging instrument at a recorded distance from the outlet or leak orifice of the flow meter that will not be exceeded in the actual performance of the leak survey. Do not exceed the operating parameters of the flow meter.

(C) Open the valve on the flow meter to set a flow rate that will create a mass emission rate equal to the mass rate specified in paragraph (i)(2)(i) of this section while observing the gas flow through the optical gas imaging instrument viewfinder. When an image of the gas emission is seen through the viewfinder at the required emission rate, make a record of the reading on the flow meter.

(v) Repeat the procedures specified in paragraphs (i)(2)(ii) through (i)(2)(iv) of this section for each configuration of the optical gas imaging instrument used during the leak survey.

(vi) To use an alternative method to demonstrate daily instrument checks, apply to the Administrator for approval of the alternative under § 60.13(i).

(3) Leak Survey Procedure. Operate the optical gas imaging instrument to image every regulated piece of equipment selected for this work practice in accordance with the instrument manufacturer's operating parameters. All emissions imaged by the optical gas imaging instrument are considered to be leaks and are subject to repair. All emissions visible to the naked eye are also considered to be leaks and are subject to repair.

(4) Recordkeeping. You must keep the records described in paragraphs (i)(4)(i) through (i)(4)(vii) of this section:

(i) The equipment, processes, and facilities for which the owner or operator chooses to use the alternative work practice.

(ii) The detection sensitivity level selected from Table 1 to subpart A of this part for the optical gas imaging instrument.

(iii) The analysis to determine the piece of equipment in contact with the lowest mass fraction of chemicals that are detectable, as specified in paragraph (i)(2)(i)(A) of this section.

(iv) The technical basis for the mass fraction of detectable chemicals used in the equation in paragraph (i)(2)(i)(B) of this section.

(v) The daily instrument check. Record the distance, per paragraph (i)(2)(iv)(B) of this section, and the flow meter reading, per paragraph (i)(2)(iv)(C) of this section, at which the leak was imaged. Keep a video record of the daily instrument check for each configuration of the optical gas imaging instrument used during the leak survey (for example, the daily instrument check must be conducted for each lens used). The video record must include a time and date stamp for each daily instrument check. The video record must be kept for 5 years.

(vi) Recordkeeping requirements in the applicable subpart. A video record must be used to document the leak survey results. The video record must include a time and date stamp for each monitoring event. A video record can be used to meet the recordkeeping requirements of the applicable subparts if each piece of regulated equipment selected for this work practice can be identified in the video record. The video record must be kept for 5 years.

(vii) The results of the annual Method 21 screening required in paragraph (h)(7) of this section. Records must be kept for all regulated equipment specified in paragraph (h)(1) of this section. Records must identify the equipment screened, the screening value measured by Method 21, the time and date of the screening, and calibration information required in the existing applicable subpart.

(5) Reporting. Submit the reports required in the applicable subpart. Submit the records of the annual Method 21 screening required in paragraph (h)(7) of this section to the Administrator via e-mail to [email protected].

§ 60.19General notification and reporting requirements.

(a) For the purposes of this part, time periods specified in days shall be measured in calendar days, even if the word “calendar” is absent, unless otherwise specified in an applicable requirement.

(b) For the purposes of this part, if an explicit postmark deadline is not specified in an applicable requirement for the submittal of a notification, application, report, or other written communication to the Administrator, the owner or operator shall postmark the submittal on or before the number of days specified in the applicable requirement. For example, if a notification must be submitted 15 days before a particular event is scheduled to take place, the notification shall be postmarked on or before 15 days preceding the event; likewise, if a notification must be submitted 15 days after a particular event takes place, the notification shall be delivered or postmarked on or before 15 days following the end of the event. The use of reliable non-Government mail carriers that provide indications of verifiable delivery of information required to be submitted to the Administrator, similar to the postmark provided by the U.S. Postal Service, or alternative means of delivery, including the use of electronic media, agreed to by the permitting authority, is acceptable.

(c) Notwithstanding time periods or postmark deadlines specified in this part for the submittal of information to the Administrator by an owner or operator, or the review of such information by the Administrator, such time periods or deadlines may be changed by mutual agreement between the owner or operator and the Administrator. Procedures governing the implementation of this provision are specified in paragraph (f) of this section.

(d) If an owner or operator of an affected facility in a State with delegated authority is required to submit periodic reports under this part to the State, and if the State has an established timeline for the submission of periodic reports that is consistent with the reporting frequency(ies) specified for such facility under this part, the owner or operator may change the dates by which periodic reports under this part shall be submitted (without changing the frequency of reporting) to be consistent with the State's schedule by mutual agreement between the owner or operator and the State. The allowance in the previous sentence applies in each State beginning 1 year after the affected facility is required to be in compliance with the applicable subpart in this part. Procedures governing the implementation of this provision are specified in paragraph (f) of this section.

(e) If an owner or operator supervises one or more stationary sources affected by standards set under this part and standards set under part 61, part 63, or both such parts of this chapter, he/she may arrange by mutual agreement between the owner or operator and the Administrator (or the State with an approved permit program) a common schedule on which periodic reports required by each applicable standard shall be submitted throughout the year. The allowance in the previous sentence applies in each State beginning 1 year after the stationary source is required to be in compliance with the applicable subpart in this part, or 1 year after the stationary source is required to be in compliance with the applicable 40 CFR part 61 or part 63 of this chapter standard, whichever is latest. Procedures governing the implementation of this provision are specified in paragraph (f) of this section.

(f)(1)(i) Until an adjustment of a time period or postmark deadline has been approved by the Administrator under paragraphs (f)(2) and (f)(3) of this section, the owner or operator of an affected facility remains strictly subject to the requirements of this part.

(ii) An owner or operator shall request the adjustment provided for in paragraphs (f)(2) and (f)(3) of this section each time he or she wishes to change an applicable time period or postmark deadline specified in this part.

(2) Notwithstanding time periods or postmark deadlines specified in this part for the submittal of information to the Administrator by an owner or operator, or the review of such information by the Administrator, such time periods or deadlines may be changed by mutual agreement between the owner or operator and the Administrator. An owner or operator who wishes to request a change in a time period or postmark deadline for a particular requirement shall request the adjustment in writing as soon as practicable before the subject activity is required to take place. The owner or operator shall include in the request whatever information he or she considers useful to convince the Administrator that an adjustment is warranted.

(3) If, in the Administrator's judgment, an owner or operator's request for an adjustment to a particular time period or postmark deadline is warranted, the Administrator will approve the adjustment. The Administrator will notify the owner or operator in writing of approval or disapproval of the request for an adjustment within 15 calendar days of receiving sufficient information to evaluate the request.

(4) If the Administrator is unable to meet a specified deadline, he or she will notify the owner or operator of any significant delay and inform the owner or operator of the amended schedule.

§ 60.20Applicability.

The provisions of this subpart apply to States upon publication of a final guideline document under § 60.22(a).

§ 60.20aApplicability.

(a) The provisions of this subpart apply upon publication of a final emission guideline under § 60.22a(a) if the guideline is published in the Federal Register after July 8, 2019.

(1) Each emission guideline promulgated under this part is subject to the requirements of this subpart, except that each emission guideline may include specific provisions in addition to or that supersede requirements of this subpart. Each emission guideline must identify explicitly any provision of this subpart that is superseded.

(2) Terms used throughout this part are defined in § 60.21a or in the Clean Air Act (Act) as amended in 1990, except that emission guidelines promulgated as individual subparts of this part may include specific definitions in addition to or that supersede definitions in § 60.21a.

(b) No standard of performance or other requirement established under this part shall be interpreted, construed, or applied to diminish or replace the requirements of a more stringent emission limitation or other applicable requirement established by the Administrator pursuant to other authority of the Act (section 112, Part C or D, or any other authority of this Act), or a standard issued under State authority.

§ 60.21Definitions.

Terms used but not defined in this subpart shall have the meaning given them in the Act and in subpart A:

(a) Designated pollutant means any air pollutant, the emissions of which are subject to a standard of performance for new stationary sources, but for which air quality criteria have not been issued and that is not included on a list published under section 108(a) or section 112(b)(1)(A) of the Act.

(b) Designated facility means any existing facility (see § 60.2(aa)) which emits a designated pollutant and which would be subject to a standard of performance for that pollutant if the existing facility were an affected facility (see § 60.2(e)).

(c) Plan means a plan under section 111(d) of the Act which establishes emission standards for designated pollutants from designated facilities and provides for the implementation and enforcement of such emission standards.

(d) Applicable plan means the plan, or most recent revision thereof, which has been approved under § 60.27(b) or promulgated under § 60.27(d).

(e) Emission guideline means a guideline set forth in subpart C of this part, or in a final guideline document published under § 60.22(a), which reflects the degree of emission reduction achievable through the application of the best system of emission reduction which (taking into account the cost of such reduction) the Administrator has determined has been adequately demonstrated for designated facilities.

(f) Emission standard means a legally enforceable regulation setting forth an allowable rate of emissions into the atmosphere, establishing an allowance system, or prescribing equipment specifications for control of air pollution emissions.

(g) Compliance schedule means a legally enforceable schedule specifying a date or dates by which a source or category of sources must comply with specific emission standards contained in a plan or with any increments of progress to achieve such compliance.

(h) Increments of progress means steps to achieve compliance which must be taken by an owner or operator of a designated facility, including:

(1) Submittal of a final control plan for the designated facility to the appropriate air pollution control agency;

(2) Awarding of contracts for emission control systems or for process modifications, or issuance of orders for the purchase of component parts to accomplish emission control or process modification;

(3) Initiation of on-site construction or installation of emission control equipment or process change;

(4) Completion of on-site construction or installation of emission control equipment or process change; and

(5) Final compliance.

(i) Region means an air quality control region designated under section 107 of the Act and described in part 81 of this chapter.

(j) Local agency means any local governmental agency.

§ 60.21aDefinitions.

Terms used but not defined in this subpart shall have the meaning given them in the Act and in subpart A of this part:

(a) Designated pollutant means any air pollutant, the emissions of which are subject to a standard of performance for new stationary sources, but for which air quality criteria have not been issued and that is not included on a list published under section 108(a) or section 112(b)(1)(A) of the Act.

(b) Designated facility means any existing facility (see § 60.2) which emits a designated pollutant and which would be subject to a standard of performance for that pollutant if the existing facility were an affected facility (see § 60.2).

(c) Plan means a plan under section 111(d) of the Act which establishes standards of performance for designated pollutants from designated facilities and provides for the implementation and enforcement of such standards of performance.

(d) Applicable plan means the plan, or most recent revision thereof, which has been approved under § 60.27a(b) or promulgated under § 60.27a(d).

(e) Emission guideline means a guideline set forth in this part, with the exception of guidelines set forth pursuant to section 129 of the Clean Air Act, or in a final guideline document published under § 60.22a(a), which reflects the degree of emission limitation achievable through the application of the best system of emission reduction which (taking into account the cost of achieving such reduction and any non-air quality health and environmental impact and energy requirements) the Administrator has determined has been adequately demonstrated for designated facilities.

(f) Standard of performance means a standard for emissions of air pollutants which reflects the degree of emission limitation achievable through the application of the best system of emission reduction which (taking into account the cost of achieving such reduction and any nonair quality health and environmental impact and energy requirements) the Administrator determines has been adequately demonstrated, including a legally enforceable regulation setting forth an allowable rate, quantity, or concentration of emissions into the atmosphere, or prescribing a design, equipment, work practice, or operational standard, or combination thereof.

(g) Compliance schedule means a legally enforceable schedule specifying a date or dates by which a source or category of sources must comply with specific standards of performance contained in a plan or with any increments of progress to achieve such compliance.

(h) Increments of progress means steps to achieve compliance which must be taken by an owner or operator of a designated facility, including:

(1) Submittal of a final control plan for the designated facility to the appropriate air pollution control agency;

(2) Awarding of contracts for emission control systems or for process modifications, or issuance of orders for the purchase of component parts to accomplish emission control or process modification;

(3) Initiation of on-site construction or installation of emission control equipment or process change;

(4) Completion of on-site construction or installation of emission control equipment or process change; and

(5) Final compliance.

(i) Region means an air quality control region designated under section 107 of the Act and described in part 81 of this chapter.

(j) Local agency means any local governmental agency.

(k) Meaningful engagement means the timely engagement with pertinent stakeholders and/or their representatives in the plan development or plan revision process. Such engagement should not be disproportionate in favor of certain stakeholders and should be informed by available best practices.

(l) Pertinent stakeholders include, but are not limited to, industry, small businesses, and communities most affected by and/or vulnerable to the impacts of the plan or plan revision.

§ 60.22Publication of guideline documents, emission guidelines, and final compliance times.

(a) Concurrently upon or after proposal of standards of performance for the control of a designated pollutant from affected facilities, the Administrator will publish a draft guideline document containing information pertinent to control of the designated pollutant form designated facilities. Notice of the availability of the draft guideline document will be published in the Federal Register and public comments on its contents will be invited. After consideration of public comments and upon or after promulgation of standards of performance for control of a designated pollutant from affected facilities, a final guideline document will be published and notice of its availability will be published in the Federal Register.

(b) Guideline documents published under this section will provide information for the development of State plans, such as:

(1) Information concerning known or suspected endangerment of public health or welfare caused, or contributed to, by the designated pollutant.

(2) A description of systems of emission reduction which, in the judgment of the Administrator, have been adequately demonstrated.

(3) Information on the degree of emission reduction which is achievable with each system, together with information on the costs and environmental effects of applying each system to designated facilities.

(4) Incremental periods of time normally expected to be necessary for the design, installation, and startup of identified control systems.

(5) An emission guideline that reflects the application of the best system of emission reduction (considering the cost of such reduction) that has been adequately demonstrated for designated facilities, and the time within which compliance with emission standards of equivalent stringency can be achieved. The Administrator will specify different emission guidelines or compliance times or both for different sizes, types, and classes of designated facilities when costs of control, physical limitations, geographical location, or similar factors make subcategorization appropriate. (6) Such other available information as the Administrator determines may contribute to the formulation of State plans.

(c) Except as provided in paragraph (d)(1) of this section, the emission guidelines and compliance times referred to in paragraph (b)(5) of this section will be proposed for comment upon publication of the draft guideline document, and after consideration of comments will be promulgated in subpart C of this part with such modifications as may be appropriate.

(d)(1) If the Administrator determines that a designated pollutant may cause or contribute to endangerment of public welfare, but that adverse effects on public health have not been demonstrated, he will include the determination in the draft guideline document and in the Federal Register notice of its availability. Except as provided in paragraph (d)(2) of this section, paragraph (c) of this section shall be inapplicable in such cases.

(2) If the Administrator determines at any time on the basis of new information that a prior determination under paragraph (d)(1) of this section is incorrect or no longer correct, he will publish notice of the determination in the Federal Register, revise the guideline document as necessary under paragraph (a) of this section, and propose and promulgate emission guidelines and compliance times under paragraph (c) of this section.

§ 60.22aPublication of emission guidelines.

(a) Concurrently upon or after proposal of standards of performance for the control of a designated pollutant from affected facilities, the Administrator will publish a draft emission guideline containing information pertinent to control of the designated pollutant from designated facilities. Notice of the availability of the draft emission guideline will be published in the Federal Register and public comments on its contents will be invited. After consideration of public comments and upon or after promulgation of standards of performance for control of a designated pollutant from affected facilities, a final emission guideline will be published and notice of its availability will be published in the Federal Register .

(b) Emission guidelines published under this section will provide information for the development of State plans, such as:

(1) Information concerning known or suspected endangerment of public health or welfare caused, or contributed to, by the designated pollutant.

(2) A description of systems of emission reduction which, in the judgment of the Administrator, have been adequately demonstrated.

(3) Information on the degree of emission limitation which is achievable with each system, together with information on the costs, nonair quality health and environmental effects, and energy requirements of applying each system to designated facilities.

(4) Incremental periods of time normally expected to be necessary for the design, installation, and startup of identified control systems.

(5) The degree of emission limitation achievable through the application of the best system of emission reduction (considering the cost of such achieving reduction and any nonair quality health and environmental impact and energy requirements) that has been adequately demonstrated for designated facilities, and the time within which compliance with standards of performance can be achieved. The Administrator may specify different degrees of emission limitation or compliance times or both for different sizes, types, and classes of designated facilities when costs of control, physical limitations, geographical location, or similar factors make subcategorization appropriate.

(6) Such other available information as the Administrator determines may contribute to the formulation of State plans.

(c) The emission guidelines and compliance times referred to in paragraph (b)(5) of this section will be proposed for comment upon publication of the draft guideline document, and after consideration of comments will be promulgated in this part with such modifications as may be appropriate.

§ 60.23Adoption and submittal of State plans; public hearings.

(a)(1) Unless otherwise specified in the applicable subpart, within 9 months after notice of the availability of a final guideline document is published under § 60.22(a), each State shall adopt and submit to the Administrator, in accordance with § 60.4 of subpart A of this part, a plan for the control of the designated pollutant to which the guideline document applies.

(2) Within nine months after notice of the availability of a final revised guideline document is published as provided in § 60.22(d)(2), each State shall adopt and submit to the Administrator any plan revision necessary to meet the requirements of this subpart.

(b) If no designated facility is located within a State, the State shall submit a letter of certification to that effect to the Administrator within the time specified in paragraph (a) of this section. Such certification shall exempt the State from the requirements of this subpart for that designated pollutant.

(c)(1) Except as provided in paragraphs (c)(2) and (c)(3) of this section, the State shall, prior to the adoption of any plan or revision thereof, conduct one or more public hearings within the State on such plan or plan revision.

(2) No hearing shall be required for any change to an increment of progress in an approved compliance schedule unless the change is likely to cause the facility to be unable to comply with the final compliance date in the schedule.

(3) No hearing shall be required on an emission standard in effect prior to the effective date of this subpart if it was adopted after a public hearing and is at least as stringent as the corresponding emission guideline specified in the applicable guideline document published under § 60.22(a).

(d) Any hearing required by paragraph (c) of this section shall be held only after reasonable notice. Notice shall be given at least 30 days prior to the date of such hearing and shall include:

(1) Notification to the public by prominently advertising the date, time, and place of such hearing in each region affected;

(2) Availability, at the time of public announcement, of each proposed plan or revision thereof for public inspection in at least one location in each region to which it will apply;

(3) Notification to the Administrator;

(4) Notification to each local air pollution control agency in each region to which the plan or revision will apply; and

(5) In the case of an interstate region, notification to any other State included in the region.

(e) The State shall prepare and retain, for a minimum of 2 years, a record of each hearing for inspection by any interested party. The record shall contain, as a minimum, a list of witnesses together with the text of each presentation.

(f) The State shall submit with the plan or revision:

(1) Certification that each hearing required by paragraph (c) of this section was held in accordance with the notice required by paragraph (d) of this section; and

(2) A list of witnesses and their organizational affiliations, if any, appearing at the hearing and a brief written summary of each presentation or written submission.

(g) Upon written application by a State agency (through the appropriate Regional Office), the Administrator may approve State procedures designed to insure public participation in the matters for which hearings are required and public notification of the opportunity to participate if, in the judgment of the Administrator, the procedures, although different from the requirements of this subpart, in fact provide for adequate notice to and participation of the public. The Administrator may impose such conditions on his approval as he deems necessary. Procedures approved under this section shall be deemed to satisfy the requirements of this subpart regarding procedures for public hearings.

§ 60.23aAdoption and submittal of State plans; public hearings.

(a)(1) Unless otherwise specified in the applicable subpart in this part, within eighteen months after publication in the Federal Register of a final emission guideline under § 60.22a(a), each State shall adopt and submit to the Administrator a plan for the control of the designated pollutant to which the emission guideline applies. The submission of such plan shall be made in electronic format according to paragraph (a)(3) of this section or as specified in an applicable emission guideline.

(2) At any time, each State may adopt and submit to the Administrator any plan revision necessary to meet the requirements of this subpart or an applicable subpart of this part.

(3) States must submit to the Administrator any plan or plan revision using the State Planning Electronic Collaboration System (SPeCS), which can be accessed through the EPA's Central Data Exchange (CDX) ( https://cdx.epa.gov/ ) or through an analogous electronic reporting tool provided by the EPA for the submission of any plan required by this subpart. Do not use SPeCS to submit confidential business information (CBI). Anything submitted using SPeCS cannot later be claimed to be CBI. The State must confer with the Regional Office for the procedures to submit CBI information. All CBI must be clearly marked as CBI.

(b) If no designated facility is located within a State, the State shall submit a letter of certification to that effect to the Administrator within the time specified in paragraph (a) of this section. Such certification shall exempt the State from the requirements of this subpart for that designated pollutant. The State must submit the letter using the SPeCS, or through an analogous electronic reporting tool provided by the EPA for the submission of any plan required by this subpart.

(c) The State shall, prior to the adoption of any plan or revision thereof, conduct one or more public hearings within the State on such plan or plan revision in accordance with the provisions under this section.

(d) Any hearing required by paragraph (c) of this section shall be held only after reasonable notice. Notice shall be given at least 30 days prior to the date of such hearing and shall include:

(1) Notification to the public by prominently advertising the date, time, and place of such hearing in each region affected. This requirement may be satisfied by advertisement on the internet;

(2) Availability, at the time of public announcement, of each proposed plan or revision thereof for public inspection in at least one location in each region to which it will apply. This requirement may be satisfied by posting each proposed plan or revision on the internet;

(3) Notification to the Administrator;

(4) Notification to each local air pollution control agency in each region to which the plan or revision will apply; and

(5) In the case of an interstate region, notification to any other State included in the region.

(e) The State may cancel the public hearing through a method it identifies if no request for a public hearing is received during the 30 day notification period under paragraph (d) of this section and the original notice announcing the 30 day notification period states that if no request for a public hearing is received the hearing will be cancelled; identifies the method and time for announcing that the hearing has been cancelled; and provides a contact phone number for the public to call to find out if the hearing has been cancelled.

(f) The State shall prepare and retain, for a minimum of 2 years, a record of each hearing for inspection by any interested party. The record shall contain, as a minimum, a list of witnesses together with the text of each presentation.

(g) The State shall submit with the plan or revision:

(1) Certification that each hearing required by paragraph (c) of this section was held in accordance with the notice required by paragraph (d) of this section; and

(2) A list of witnesses and their organizational affiliations, if any, appearing at the hearing and a brief written summary of each presentation or written submission.

(h) Upon written application by a State agency (through the appropriate Regional Office), the Administrator may approve State procedures designed to insure public participation in the matters for which hearings are required and public notification of the opportunity to participate if, in the judgment of the Administrator, the procedures, although different from the requirements of this subpart, in fact provide for adequate notice to and participation of the public. The Administrator may impose such conditions on his approval as he deems necessary. Procedures approved under this section shall be deemed to satisfy the requirements of this subpart regarding procedures for public hearings.

(i) The State must submit, with the plan or revision, documentation of meaningful engagement including a list of identified pertinent stakeholders and/or their representatives, a summary of the engagement conducted, a summary of stakeholder input received, and a description of how stakeholder input was considered in the development of the plan or plan revisions.

§ 60.24Emission standards and compliance schedules.

(a) Each plan shall include emission standards and compliance schedules.

(b) (1) Emission standards shall either be based on an allowance system or prescribe allowable rates of emissions except when it is clearly impracticable. Such cases will be identified in the guideline documents issued under § 60.22. Where emission standards prescribing equipment specifications are established, the plan shall, to the degree possible, set forth the emission reductions achievable by implementation of such specifications, and may permit compliance by the use of equipment determined by the State to be equivalent to that prescribed.

(2) Test methods and procedures for determining compliance with the emission standards shall be specified in the plan. Methods other than those specified in appendix A to this part may be specified in the plan if shown to be equivalent or alternative methods as defined in § 60.2 (t) and (u).

(3) Emission standards shall apply to all designated facilities within the State. A plan may contain emission standards adopted by local jurisdictions provided that the standards are enforceable by the State.

(c) Except as provided in paragraph (f) of this section, where the Administrator has determined that a designated pollutant may cause or contribute to endangerment of public health, emission standards shall be no less stringent than the corresponding emission guideline(s) specified in subpart C of this part, and final compliance shall be required as expeditiously as practicable but no later than the compliance times specified in subpart C of this part.

(d) Where the Administrator has determined that a designated pollutant may cause or contribute to endangerment of public welfare but that adverse effects on public health have not been demonstrated, States may balance the emission guidelines, compliance times, and other information provided in the applicable guideline document against other factors of public concern in establishing emission standards, compliance schedules, and variances. Appropriate consideration shall be given to the factors specified in § 60.22(b) and to information presented at the public hearing(s) conducted under § 60.23(c).

(e)(1) Any compliance schedule extending more than 12 months from the date required for submittal of the plan must include legally enforceable increments of progress to achieve compliance for each designated facility or category of facilities. Unless otherwise specified in the applicable subpart, increments of progress must include, where practicable, each increment of progress specified in § 60.21(h) and must include such additional increments of progress as may be necessary to permit close and effective supervision of progress toward final compliance.

(2) A plan may provide that compliance schedules for individual sources or categories of sources will be formulated after plan submittal. Any such schedule shall be the subject of a public hearing held according to § 60.23 and shall be submitted to the Administrator within 60 days after the date of adoption of the schedule but in no case later than the date prescribed for submittal of the first semiannual report required by § 60.25(e).

(f) Unless otherwise specified in the applicable subpart on a case-by-case basis for particular designated facilities or classes of facilities, States may provide for the application of less stringent emissions standards or longer compliance schedules than those otherwise required by paragraph (c) of this section, provided that the State demonstrates with respect to each such facility (or class of facilities):

(1) Unreasonable cost of control resulting from plant age, location, or basic process design;

(2) Physical impossibility of installing necessary control equipment; or

(3) Other factors specific to the facility (or class of facilities) that make application of a less stringent standard or final compliance time significantly more reasonable.

(g) Nothing in this subpart shall be construed to preclude any State or political subdivision thereof from adopting or enforcing (1) emission standards more stringent than emission guidelines specified in subpart C of this part or in applicable guideline documents or (2) compliance schedules requiring final compliance at earlier times than those specified in subpart C or in applicable guideline documents.

§ 60.24aStandards of performance and compliance schedules.

(a) Each plan shall include standards of performance and compliance schedules.

(b) Standards of performance shall be in the form of an allowable rate, quantity, or concentration of emissions, except when it is not feasible to prescribe or enforce such a standard of performance. The EPA shall identify such cases in the emission guidelines issued under § 60.22a. Where standards of performance prescribing design, equipment, work practice, or operational standards, or combination thereof are established, the plan shall, to the degree possible, set forth the emission reductions achievable by implementation of such standards, and may permit compliance by the use of equipment determined by the State to be equivalent to that prescribed.

(1) Test methods and procedures for determining compliance with the standards of performance shall be specified in the plan. Methods other than those specified in appendix A to this part or an applicable subpart of this part may be specified in the plan if shown to be equivalent or alternative methods as defined in § 60.2.

(2) Standards of performance shall apply to all designated facilities within the State. A plan may contain standards of performance adopted by local jurisdictions provided that the standards are enforceable by the State.

(c) Except as provided in paragraph (e) of this section, standards of performance shall be no less stringent than the corresponding emission guideline(s) specified in this part, and final compliance shall be required as expeditiously as practicable, but no later than the compliance times specified in an applicable subpart of this part.

(d) Any compliance schedule extending more than twenty months from the date required for submittal of the plan must include legally enforceable increments of progress to achieve compliance for each designated facility or category of facilities. Unless otherwise specified in the applicable emission guideline, increments of progress must include, where practicable, each increment of progress specified in § 60.21a(h) and must include such additional increments of progress as may be necessary to permit close and effective supervision of progress toward final compliance.

(e)(1) The State may apply a standard of performance to a particular designated facility that is less stringent than or has a compliance schedule longer than otherwise required by an applicable emission guideline taking into consideration that facility's remaining useful life and other factors, provided that the State demonstrates with respect to each such facility (or class of such facilities) that the facility cannot reasonably achieve the degree of emission limitation determined by the EPA based on:

(i) Unreasonable cost of control resulting from plant age, location, or basic process design;

(ii) Physical impossibility or technical infeasibility of installing necessary control equipment; or

(iii) Other circumstances specific to the facility.

(2) For the purpose of this paragraph (e), the State must demonstrate that there are fundamental differences between the information specific to a facility (or class of such facilities) and the information EPA considered in determining the degree of emission limitation achievable through application of the best system of emission reduction or the compliance schedule that make achieving such degree of emission limitation or meeting such compliance schedule unreasonable for that facility.

(f) If the State makes the required demonstration in paragraph (e) of this section, the plan may apply a standard of performance that is less stringent than required by an applicable emission guideline.

(1) The standard of performance applied under this paragraph (f) must be no less stringent (or have a compliance schedule no longer) than is necessary to address the fundamental differences identified under paragraph (e) of this section. To the extent necessary to determine a standard of performance satisfying that criteria, the State must evaluate the systems of emission reduction identified in the applicable emission guideline using the factors and evaluation metrics EPA considered in assessing those systems, including technical feasibility, the amount of emission reductions, the cost of achieving such reductions, any nonair quality health and environmental impacts, and energy requirements. The States may also consider, as justified, other factors specific to the facility that were the basis of the demonstration under paragraph (e) as well as other systems of emission reduction in addition to those EPA considered in the applicable emission guideline.

(2) A standard of performance under this paragraph (f) must be in the form as required by the applicable emission guideline.

(g) Where a State applies a standard of performance pursuant to paragraph (f) of this section on the basis of an operating condition(s) within the designated facility's control, such as remaining useful life or restricted capacity, the plan must also include such operating condition(s) as an enforceable requirement. The plan must also include requirements to provide for the implementation and enforcement of the operating condition(s), such as requirements for monitoring, reporting, and recordkeeping.

(h) A less stringent standard of performance must meet all other applicable requirements, including in this subpart and in any applicable emission guideline.

(i) Nothing in this subpart shall be construed to preclude any State or political subdivision thereof from adopting or enforcing, as part of the plan:

(1) Standards of performance more stringent than emission guidelines specified in this part; or

(2) Compliance schedules requiring final compliance at earlier times than those specified in applicable emission guidelines.

(ii) [Reserved]

§ 60.25Emission inventories, source surveillance, reports.

(a) Each plan shall include an inventory of all designated facilities, including emission data for the designated pollutants and information related to emissions as specified in appendix D to this part. Such data shall be summarized in the plan, and emission rates of designated pollutants from designated facilities shall be correlated with applicable emission standards. As used in this subpart, “correlated” means presented in such a manner as to show the relationship between measured or estimated amounts of emissions and the amounts of such emissions allowable under applicable emission standards.

(b) Each plan shall provide for monitoring the status of compliance with applicable emission standards. Each plan shall, as a minimum, provide for:

(1) Legally enforceable procedures for requiring owners or operators of designated facilities to maintain records and periodically report to the State information on the nature and amount of emissions from such facilities, and/or such other information as may be necessary to enable the State to determine whether such facilities are in compliance with applicable portions of the plan. Submission of electronic documents shall comply with the requirements of 40 CFR part 3—(Electronic reporting).

(2) Periodic inspection and, when applicable, testing of designated facilities.

(c) Each plan shall provide that information obtained by the State under paragraph (b) of this section shall be correlated with applicable emission standards (see § 60.25(a)) and made available to the general public.

(d) The provisions referred to in paragraphs (b) and (c) of this section shall be specifically identified. Copies of such provisions shall be submitted with the plan unless:

(1) They have been approved as portions of a preceding plan submitted under this subpart or as portions of an implementation plan submitted under section 110 of the Act, and

(2) The State demonstrates:

(i) That the provisions are applicable to the designated pollutant(s) for which the plan is submitted, and

(ii) That the requirements of § 60.26 are met.

(e) The State shall submit reports on progress in plan enforcement to the Administrator on an annual (calendar year) basis, commencing with the first full report period after approval of a plan or after promulgation of a plan by the Administrator. Information required under this paragraph must be included in the annual report required by § 51.321 of this chapter.

(f) Each progress report shall include:

(1) Enforcement actions initiated against designated facilities during the reporting period, under any emission standard or compliance schedule of the plan.

(2) Identification of the achievement of any increment of progress required by the applicable plan during the reporting period.

(3) Identification of designated facilities that have ceased operation during the reporting period.

(4) Submission of emission inventory data as described in paragraph (a) of this section for designated facilities that were not in operation at the time of plan development but began operation during the reporting period.

(5) Submission of additional data as necessary to update the information submitted under paragraph (a) of this section or in previous progress reports.

(6) Submission of copies of technical reports on all performance testing on designated facilities conducted under paragraph (b)(2) of this section, complete with concurrently recorded process data.

§ 60.25aEmission inventories, source surveillance, reports.

(a) Each plan shall include an inventory of all designated facilities, including emission data for the designated pollutants and any additional information related to emissions as specified in the applicable emission guideline. Such data shall be summarized in the plan, and emission rates of designated pollutants from designated facilities shall be correlated with applicable standards of performance. As used in this subpart, correlated means presented in such a manner as to show the relationship between measured or estimated amounts of emissions and the amounts of such emissions allowable under applicable standards of performance.

(b) Each plan shall provide for monitoring the status of compliance with applicable standards of performance. Each plan shall, as a minimum, provide for:

(1) Legally enforceable procedures for requiring owners or operators of designated facilities to maintain records and periodically report to the State information on the nature and amount of emissions from such facilities, and/or such other information as may be necessary to enable the State to determine whether such facilities are in compliance with applicable portions of the plan. Submission of electronic documents shall comply with the requirements of 40 CFR part 3 (Electronic reporting).

(2) Periodic inspection and, when applicable, testing of designated facilities.

(c) Each plan shall provide that information obtained by the State under paragraph (b) of this section shall be correlated with applicable standards of performance (see § 60.25a(a)) and made available to the general public.

(d) The provisions referred to in paragraphs (b) and (c) of this section shall be specifically identified. Copies of such provisions shall be submitted with the plan unless:

(1) They have been approved as portions of a preceding plan submitted under this subpart or as portions of an implementation plan submitted under section 110 of the Act; and

(2) The State demonstrates:

(i) That the provisions are applicable to the designated pollutant(s) for which the plan is submitted, and

(ii) That the requirements of § 60.26a are met.

(e) The State shall submit reports on progress in plan enforcement to the Administrator on an annual (calendar year) basis, commencing with the first full report period after approval of a plan or after promulgation of a plan by the Administrator. Information required under this paragraph must be included in the annual report required by § 51.321 of this chapter.

(f) Each progress report shall include:

(1) Enforcement actions initiated against designated facilities during the reporting period, under any standard of performance or compliance schedule of the plan.

(2) Identification of the achievement of any increment of progress required by the applicable plan during the reporting period.

(3) Identification of designated facilities that have ceased operation during the reporting period.

(4) Submission of emission inventory data as described in paragraph (a) of this section for designated facilities that were not in operation at the time of plan development but began operation during the reporting period.

(5) Submission of additional data as necessary to update the information submitted under paragraph (a) of this section or in previous progress reports.

(6) Submission of copies of technical reports on all performance testing on designated facilities conducted under paragraph (b)(2) of this section, complete with concurrently recorded process data.

§ 60.26Legal authority.

(a) Each plan shall show that the State has legal authority to carry out the plan, including authority to:

(1) Adopt emission standards and compliance schedules applicable to designated facilities.

(2) Enforce applicable laws, regulations, standards, and compliance schedules, and seek injunctive relief.

(3) Obtain information necessary to determine whether designated facilities are in compliance with applicable laws, regulations, standards, and compliance schedules, including authority to require recordkeeping and to make inspections and conduct tests of designated facilities.

(4) Require owners or operators of designated facilities to install, maintain, and use emission monitoring devices and to make periodic reports to the State on the nature and amounts of emissions from such facilities; also authority for the State to make such data available to the public as reported and as correlated with applicable emission standards.

(b) The provisions of law or regulations which the State determines provide the authorities required by this section shall be specifically identified. Copies of such laws or regulations shall be submitted with the plan unless:

(1) They have been approved as portions of a preceding plan submitted under this subpart or as portions of an implementation plan submitted under section 110 of the Act, and

(2) The State demonstrates that the laws or regulations are applicable to the designated pollutant(s) for which the plan is submitted.

(c) The plan shall show that the legal authorities specified in this section are available to the State at the time of submission of the plan. Legal authority adequate to meet the requirements of paragraphs (a)(3) and (4) of this section may be delegated to the State under section 114 of the Act.

(d) A State governmental agency other than the State air pollution control agency may be assigned responsibility for carrying out a portion of a plan if the plan demonstrates to the Administrator's satisfaction that the State governmental agency has the legal authority necessary to carry out that portion of the plan.

(e) The State may authorize a local agency to carry out a plan, or portion thereof, within the local agency's jurisdiction if the plan demonstrates to the Administrator's satisfaction that the local agency has the legal authority necessary to implement the plan or portion thereof, and that the authorization does not relieve the State of responsibility under the Act for carrying out the plan or portion thereof.

§ 60.26aLegal authority.

(a) Each plan or plan revision shall show that the State has legal authority to carry out the plan or plan revision, including authority to:

(1) Adopt standards of performance and compliance schedules applicable to designated facilities.

(2) Enforce applicable laws, regulations, standards, and compliance schedules, and seek injunctive relief.

(3) Obtain information necessary to determine whether designated facilities are in compliance with applicable laws, regulations, standards, and compliance schedules, including authority to require recordkeeping and to make inspections and conduct tests of designated facilities.

(4) Require owners or operators of designated facilities to install, maintain, and use emission monitoring devices and to make periodic reports to the State on the nature and amounts of emissions from such facilities; also authority for the State to make such data available to the public as reported and as correlated with applicable standards of performance.

(b) The provisions of law or regulations which the State determines provide the authorities required by this section shall be specifically identified. Copies of such laws or regulations shall be submitted with the plan unless:

(1) They have been approved as portions of a preceding plan submitted under this subpart or as portions of an implementation plan submitted under section 110 of the Act; and

(2) The State demonstrates that the laws or regulations are applicable to the designated pollutant(s) for which the plan is submitted.

(c) The plan shall show that the legal authorities specified in this section are available to the State at the time of submission of the plan. Legal authority adequate to meet the requirements of paragraphs (a)(3) and (4) of this section may be delegated to the State under section 114 of the Act.

(d) A State governmental agency other than the State air pollution control agency may be assigned responsibility for carrying out a portion of a plan if the plan demonstrates to the Administrator's satisfaction that the State governmental agency has the legal authority necessary to carry out that portion of the plan.

(e) The State may authorize a local agency to carry out a plan, or portion thereof, within the local agency's jurisdiction if the plan demonstrates to the Administrator's satisfaction that the local agency has the legal authority necessary to implement the plan or portion thereof, and that the authorization does not relieve the State of responsibility under the Act for carrying out the plan or portion thereof.

§ 60.27Actions by the Administrator.

(a) The Administrator may, whenever he determines necessary, extend the period for submission of any plan or plan revision or portion thereof.

(b) After receipt of a plan or plan revision, the Administrator will propose the plan or revision for approval or disapproval. The Administrator will, within four months after the date required for submission of a plan or plan revision, approve or disapprove such plan or revision or each portion thereof.

(c) The Administrator will, after consideration of any State hearing record, promptly prepare and publish proposed regulations setting forth a plan, or portion thereof, for a State if:

(1) The State fails to submit a plan within the time prescribed;

(2) The State fails to submit a plan revision required by § 60.23(a)(2) within the time prescribed; or

(3) The Administrator disapproves the State plan or plan revision or any portion thereof, as unsatisfactory because the requirements of this subpart have not been met.

(d) The Administrator will, within six months after the date required for submission of a plan or plan revision, promulgate the regulations proposed under paragraph (c) of this section with such modifications as may be appropriate unless, prior to such promulgation, the State has adopted and submitted a plan or plan revision which the Administrator determines to be approvable.

(e)(1) Except as provided in paragraph (e)(2) of this section, regulations proposed and promulgated by the Administrator under this section will prescribe emission standards of the same stringency as the corresponding emission guideline(s) specified in the final guideline document published under § 60.22(a) and will require final compliance with such standards as expeditiously as practicable but no later than the times specified in the guideline document.

(2) Upon application by the owner or operator of a designated facility to which regulations proposed and promulgated under this section will apply, the Administrator may provide for the application of less stringent emission standards or longer compliance schedules than those otherwise required by this section in accordance with the criteria specified in § 60.24(f).

(f) Prior to promulgation of a plan under paragraph (d) of this section, the Administrator will provide the opportunity for at least one public hearing in either:

(1) Each State that failed to hold a public hearing as required by § 60.23(c); or

(2) Washington, DC or an alternate location specified in the Federal Register.

§ 60.27aActions by the Administrator.

(a) The Administrator may, whenever he determines necessary, amend the period for submission of any plan or plan revision or portion thereof.

(b) After determination that a plan or plan revision is complete per the requirements of § 60.27a(g), the Administrator will take action on the plan or revision. The Administrator will, within twelve months of finding that a plan or plan revision is complete, approve or disapprove such plan or revision or each portion thereof.

(1) Full and partial approval and disapproval. In the case of any plan or plan revision on which the Administrator is required to act under this paragraph (b), the Administrator shall approve such plan or plan revision as a whole if it meets all of the applicable requirements of this subpart. If a portion of the plan or plan revision meets all the applicable requirements of this subpart, the Administrator may approve the plan or plan revision in part and disapprove in part. The plan or plan revision shall not be treated as meeting the requirements of this chapter until the Administrator approves the entire plan or revision as complying with the applicable requirements of this subpart.

(2) Conditional approval. The Administrator may approve a plan or plan revision based on a commitment of the State to adopt and submit to the Administrator specific enforceable measures by a date certain, but not later than twelve months after the date of conditional approval of the plan or plan revision. Any such conditional approval shall be treated as a disapproval if the State fails to comply with such commitment.

(c) The Administrator will promulgate, through notice-and-comment rulemaking, a Federal plan, or portion thereof, at any time within twelve months after:

(1) The State fails to submit a plan or plan revision within the time prescribed or the State has failed to satisfy the minimum criteria under paragraph (g) of this section as of the time prescribed in paragraph (g)(1) of this section; or

(2) The Administrator disapproves the required State plan or plan revision or any portion thereof, as unsatisfactory because the applicable requirements of this subpart or an applicable emission guideline under this part have not been met.

(d) The Administrator will promulgate a final Federal plan, or portion thereof, as described in paragraph (c) of this section unless the State corrects the deficiency, and the Administrator approves the plan or plan revision, before the Administrator promulgates such Federal plan.

(e)(1) Except as provided in paragraph (e)(2) of this section, a federal plan promulgated by the Administrator under this section will prescribe standards of performance of the same stringency as the corresponding emission guideline(s) specified in the final emission guideline published under § 60.22a(a) and will require compliance with such standards as expeditiously as practicable but no later than the times specified in the emission guideline.

(2) Upon application by the owner or operator of a designated facility to which regulations proposed and promulgated under this section will apply, the Administrator may provide for the application of less stringent standards of performance or longer compliance schedules than those otherwise required by this section in accordance with the criteria specified in § 60.24a(e).

(f) Prior to promulgation of a Federal plan under paragraph (d) of this section, the Administrator will conduct meaningful engagement with pertinent stakeholders and/or their representatives and provide the opportunity for at least one public hearing in either:

(1) Each State that failed to submit a required complete plan or plan revision, or whose required plan or plan revision is disapproved by the Administrator; or

(2) Washington, DC or an alternate location specified in the Federal Register .

(g) Each plan or plan revision that is submitted to the Administrator shall be reviewed for completeness as described in paragraphs (g)(1) through (3) of this section.

(1) General. Within 60 days of the Administrator's receipt of a State submission, the Administrator shall determine whether the minimum criteria for completeness have been met for a plan submission or revision. Any plan or plan revision that a State submits to the EPA, and that has not been determined by the EPA within 60 days after the Administrator's receipt of a State submission to have failed to meet the minimum criteria, shall on that date be deemed by operation of law to meet such minimum criteria. Where the Administrator determines that a plan submission does not meet the minimum criteria of this paragraph (g), the State will be treated as not having made the submission and the requirements of this section regarding promulgation of a Federal plan shall apply.

(2) Administrative criteria. In order to be deemed complete, a State plan must contain each of the following administrative criteria:

(i) A formal letter of submittal from the Governor or her designee requesting EPA approval of the plan or revision thereof;

(ii) Evidence that the State has adopted the plan in the state code or body of regulations; or issued the permit, order, consent agreement (hereafter “document”) in final form. That evidence must include the date of adoption or final issuance as well as the effective date of the plan, if different from the adoption/issuance date;

(iii) Evidence that the State has the necessary legal authority under state law to adopt and implement the plan;

(iv) A copy of the actual regulation, or document submitted for approval and incorporation by reference into the plan, including indication of the changes made (such as redline/strikethrough) to the existing approved plan, where applicable. The submittal must be a copy of the official state regulation or document signed, stamped and dated by the appropriate state official indicating that it is fully enforceable by the State. The effective date of the regulation or document must, whenever possible, be indicated in the document itself. The State's electronic copy must be an exact duplicate of the hard copy. If the regulation/document provided by the State for approval and incorporation by reference into the plan is a copy of an existing publication, the State submission should, whenever possible, include a copy of the publication cover page and table of contents;

(v) Evidence that the State followed all of the procedural requirements of the state's laws and constitution in conducting and completing the adoption and issuance of the plan;

(vi) Evidence that public notice was given of the proposed change with procedures consistent with the requirements of § 60.23a, including the date of publication of such notice;

(vii) Certification that public hearing(s) were held in accordance with the information provided in the public notice and the State's laws and constitution, if applicable and consistent with the public hearing requirements in § 60.23a;

(viii) Compilation of public comments and the State's response thereto;

(ix) Documentation of meaningful engagement, including a list of pertinent stakeholders or their representatives, a summary of the engagement conducted, and a summary of stakeholder input received, and a description of how stakeholder input was considered in the development of the plan or plan revisions; and

(x) Such other criteria for completeness as may be specified by the Administrator under the applicable emission guidelines.

(3) Technical criteria. In order to be deemed complete, a State plan must contain each of the following technical criteria:

(i) Description of the plan approach and geographic scope;

(ii) Identification of each designated facility, identification of standards of performance for the designated facilities, and monitoring, recordkeeping and reporting requirements that will determine compliance by each designated facility;

(iii) Identification of compliance schedules and/or increments of progress;

(iv) Demonstration that the State plan submittal is projected to achieve emissions performance under the applicable emission guidelines;

(v) Documentation of state recordkeeping and reporting requirements to determine the performance of the plan as a whole; and

(vi) Demonstration that each emission standard is quantifiable, non-duplicative, permanent, verifiable, and enforceable.

(h) The requirements of this paragraph (h) apply to parallel processing. A State may submit a plan requesting parallel processing prior to adoption and to completion of public outreach and engagement by the State in order to expedite review and to provide an opportunity for the State to consider EPA comments prior to submission of a final plan for final review and action. Under these circumstances and at the discretion of the EPA, the following exceptions to the completeness criteria under paragraph (g)(2) of this section apply to plans submitted explicitly for parallel processing:

(1) The letter required by paragraph (g)(2)(i) of this section must request that EPA propose approval of the proposed plan by parallel processing;

(2) In lieu of paragraph (g)(2)(ii) of this section, the State must submit a schedule for final adoption or issuance of the plan;

(3) In lieu of paragraph (g)(2)(iv) of this section, the plan must include a copy of the proposed/draft regulation or document, including indication of the proposed changes to be made to the existing approved plan, where applicable;

(4) In lieu of paragraph (g)(2)(ix) of this section, the plan must include documentation of the engagement conducted prior to the parallel processing submittal and of any planned additional meaningful engagement to be conducted prior to adoption of the final plan; and

(5) The requirements of paragraphs (g)(2)(v) through (viii) of this section do not apply to plans submitted for parallel processing. The exceptions granted in the preceding sentence apply only to EPA's determination of proposed action and all requirements of paragraph (g)(2) of this section must be met prior to publication of EPA's final determination of plan approvability.

(i) The requirements of this paragraph (i) apply to calls for plan revisions. Whenever the Administrator finds that the applicable plan is substantially inadequate to meet the requirements of the applicable emission guidelines in this part, to provide for the implementation of the applicable requirements, or to otherwise comply with any applicable requirement of this subpart or the Clean Air Act, the Administrator shall require the State to revise the plan as necessary to correct such inadequacies. The Administrator must notify the State of the inadequacies and such plan revisions shall be submitted to the Administrator within twelve months or as determined by the Administrator. Such findings and notice must be public.

(1) Any finding under this paragraph (i) shall, to the extent the Administrator deems appropriate, subject the State to the requirements of this part to which the State was subject when it developed and submitted the plan for which such finding was made, except that the Administrator may adjust any dates applicable under such requirements as appropriate.

(2) If the Administrator makes this finding on the basis that a State is failing to implement an approved plan, or part of an approved plan, the State may submit a demonstration to the Administrator it is adequately implementing the requirements of the approved State plan in lieu of submitting a plan revision. Such demonstration must be submitted by the deadline established under this paragraph (i).

(j) The requirements of this paragraph (j) apply to error corrections. Whenever the Administrator determines that the Administrator's action approving, disapproving, or promulgating any plan or plan revision (or portion thereof) was in error, the Administrator may in the same manner as the approval, disapproval, or promulgation revise such action as appropriate without requiring any further submission from the State. Such determination and the basis thereof shall be provided to the State and public.

§ 60.28Plan revisions by the State.

(a) Plan revisions which have the effect of delaying compliance with applicable emission standards or increments of progress or of establishing less stringent emission standards shall be submitted to the Administrator within 60 days after adoption in accordance with the procedures and requirements applicable to development and submission of the original plan.

(b) More stringent emission standards, or orders which have the effect of accelerating compliance, may be submitted to the Administrator as plan revisions in accordance with the procedures and requirements applicable to development and submission of the original plan.

(c) A revision of a plan, or any portion thereof, shall not be considered part of an applicable plan until approved by the Administrator in accordance with this subpart.

§ 60.28aPlan revisions by the State.

(a) Any significant revision to a State plan shall be adopted by such State after reasonable notice, public hearing, and meaningful engagement. For plan revisions required in response to a revised emission guideline, such plan revisions shall be submitted to the Administrator within fifteen months, or as determined by the Administrator, after publication in the Federal Register of a final revised emission guideline under § 60.22a. All plan revisions must be submitted in accordance with the procedures and requirements applicable to development and submission of the original plan.

(b) A revision of a plan, or any portion thereof, shall not be considered part of an applicable plan until approved by the Administrator in accordance with this subpart.

§ 60.29Plan revisions by the Administrator.

After notice and opportunity for public hearing in each affected State, the Administrator may revise any provision of an applicable plan if:

(a) The provision was promulgated by the Administrator, and

(b) The plan, as revised, will be consistent with the Act and with the requirements of this subpart.

§ 60.29aPlan revisions by the Administrator.

After notice and opportunity for public hearing in each affected State, and meaningful engagement for any significant revision, the Administrator may revise any provision of an applicable Federal plan if:

(a) The provision was promulgated by the Administrator; and

(b) The plan, as revised, will be consistent with the Act and with the requirements of this subpart.

§ 60.30Scope.

The following subparts contain emission guidelines and compliance times for the control of certain designated pollutants in accordance with section 111(d) and section 129 of the Clean Air Act and subpart B of this part.

(a) Subpart Ca [Reserved]

(b) Subpart Cb—Municipal Waste Combustors.

(c) Subpart Cc—Municipal Solid Waste Landfills.

(d) Subpart Cd—Sulfuric Acid Production Plants.

(e) Subpart Ce—Hospital/Medical/Infectious Waste Incinerators.

§ 60.30bScope and delegation of authority.

(a) This subpart contains emission guidelines and compliance schedules for the control of certain designated pollutants from certain municipal waste combustors in accordance with section 111(d) and section 129 of the Clean Air Act and subpart B of this part. The provisions in these emission guidelines apply instead of the provisions of § 60.24(f) of subpart B of this part.

(b) The following authorities are retained by EPA:

(1) Approval of exemption claims in § 60.32b(b)(1), (d), (e), (f)(1), (i)(1);

(2) Approval of a nitrogen oxides trading program under § 60.33b(d)(2);

(3) Approval of major alternatives to test methods;

(4) Approval of major alternatives to monitoring;

(5) Waiver of recordkeeping; and

(6) Performance test and data reduction waivers under § 608(b).

§ 60.30cScope.

This subpart contains emission guidelines and compliance times for the control of certain designated pollutants from certain designated municipal solid waste landfills in accordance with section 111(d) of the Act and subpart B.

§ 60.30dDesignated facilities.

Sulfuric acid production units. The designated facility to which §§ 60.31d and 60.32d apply is each existing “sulfuric acid production unit” as defined in § 60.81(a) of subpart H of this part.

§ 60.30eScope.

This subpart contains emission guidelines and compliance times for the control of certain designated pollutants from hospital/medical/infectious waste incinerator(s) (HMIWI) in accordance with sections 111 and 129 of the Clean Air Act and subpart B of this part. The provisions in these emission guidelines supersede the provisions of § 60.24(f) of subpart B of this part.

§ 60.30fScope and delegated authorities.

This subpart establishes Emission Guidelines and compliance times for the control of designated pollutants from certain designated municipal solid waste (MSW) landfills in accordance with section 111(d) of the Clean Air Act and subpart B of this part.

(a) If you are the Administrator of an air quality program in a state or United States protectorate with one or more existing MSW landfills that commenced construction, modification, or reconstruction on or before July 17, 2014, you must submit a state plan to the U.S. Environmental Protection Agency (EPA) that implements the Emission Guidelines contained in this subpart. The requirements for state and federal plans are specified in subpart B of this part with the exception that §§ 60.23 and 60.27 will not apply. Notwithstanding the provisions of § 60.20a(a) in subpart Ba of this part, the requirements of §§ 60.23a and 60.27a will apply for state plans submitted after September 6, 2019, and federal plans, except that the requirements of § 60.23a(a)(1) will apply to a notice of availability of a final guideline document that was published under § 60.22(a). Likewise, the requirements of § 60.27a(e)(1) will refer to a final guideline document that was published under § 60.22(a).

(b) You must submit a state plan to the EPA by August 29, 2019.

(c) The following authorities will not be delegated to state, local, or tribal agencies:

(1) Approval of alternative methods to determine the NMOC concentration or a site-specific methane generation rate constant (k).

(2) [Reserved]

§ 60.31Definitions.

Terms used but not defined in this subpart have the meaning given them in the Act and in subparts A and B of this part.

§ 60.31bDefinitions.

Terms used but not defined in this subpart have the meaning given them in the Clean Air Act and subparts A, B, and Eb of this part.

EPA means the Administrator of the U.S. EPA or employee of the U.S. EPA who is delegated to perform the specified task.

Municipal waste combustor plant means one or more designated facilities (as defined in § 60.32b) at the same location.

Semi-suspension refuse-derived fuel-fired combustor/wet refuse-derived fuel process conversion means a combustion unit that was converted from a wet refuse-derived fuel process to a dry refuse-derived fuel process, and because of constraints in the design of the system, includes a low furnace height (less than 60 feet between the grate and the roof) and a high waste capacity-to-undergrate air zone ratio (greater than 300 tons of waste per day (tpd) fuel per each undergrate air zone).

Spreader stoker fixed floor refuse-derived fuel-fired combustor/100 percent coal capable means a spreader stoker type combustor with a fixed floor grate design that typically fires 100 percent refuse-derived fuel but is equipped to burn 100 percent coal instead of refuse-derived fuel to fulfill 100 percent steam or energy demand.

§ 60.31cDefinitions.

Terms used but not defined in this subpart have the meaning given them in the Act and in subparts A, B, and WWW of this part.

Municipal solid waste landfill or MSW landfill means an entire disposal facility in a contiguous geographical space where household waste is placed in or on land. An MSW landfill may also receive other types of RCRA Subtitle D wastes such as commercial solid waste, nonhazardous sludge, conditionally exempt small quantity generator waste, and industrial solid waste. Portions of an MSW landfill may be separated by access roads. An MSW landfill may be publicly or privately owned. An MSW landfill may be a new MSW landfill, an existing MSW landfill or a lateral expansion.

§ 60.31dEmissions guidelines.

Sulfuric acid production units. The emission guideline for designated facilities is 0.25 grams sulfuric acid mist (as measured by EPA Reference Method 8 of appendix A of this part) per kilogram (0.5 pounds per ton) of sulfuric acid produced, the production being expressed as 100 percent sulfuric acid.

§ 60.31eDefinitions.

Terms used but not defined in this subpart have the meaning given them in the Clean Air Act and in subparts A, B, and Ec of this part.

Standard Metropolitan Statistical Area or SMSA means any areas listed in OMB Bulletin No. 93-17 entitled “Revised Statistical Definitions for Metropolitan Areas” dated June 30, 1993 (incorporated by reference, see § 60.17).

1,765 sections

Cite this law

STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES (U.S.C.). Retrieved via LawPlayer, https://lawplayer.com/us/act/cfr-title-40-part-60

United States government works (U.S. Code, Code of Federal Regulations) are in the public domain under 17 U.S.C. § 105.

US-Gov-PublicDomain

本頁資料來源:GPO govinfo / eCFR·整理提供:法律人 LawPlayer· lawplayer.com